• 제목/요약/키워드: Target Exposure Index

검색결과 31건 처리시간 0.026초

신규 고열 위험 업종 선정을 위한 우선순위 및 온열 위험 평가 (Prioritizing for Selection of New High-heat Risk Industries and Thermal Risk Assessment)

  • 신새미;이혜민;기노성;박정민;변상훈;김성호
    • 한국산업보건학회지
    • /
    • 제33권2호
    • /
    • pp.230-246
    • /
    • 2023
  • Objectives: The climate crisis has arrived and heat-related illnesses are increasing. It is necessary to discover new high-heat risk industries and understand the environment . It is also necessary to prioritize risks of industries that have not been included in the management target to date. The study was intended to monitor and evaluate the thermal risk of high-priority workplaces. Methods: A prioritization method was developed based on five factors: occurrence of and death due to heat-related illnesses, work environment monitoring, indoor work rate, small heat source, and limited heat dissipation. it, was applied to industrial accidents caused by heat-related illnesses. Wet bulb temperature index and apparent temperature were measured in July and August at 24 workplaces in seven industries and assessed for thermal risk. Results: The wet bulb temperature index was in the range of 23.8~31.9℃, and exposure limits were exceeded in the growing of crops, food services activities and accommodation, and building construction. The apparent temperature was in the range of 26.8~36.7℃, and exceeded the temperature standard for issuing heatwave warnings in growing of crops, food services activities and accommodation, warehousing, welding, and building construction. Both temperature index in growing of crops and building construction were higher than the outside air temperature. Conclusions: In the workplace, risks in industries that have not be controlled and recognized through existing systems was identified. it is necessary to provide break times according to the work-rest time ratio required during dangerous time period.

Dosimetric comparison between modulated arc therapy and static intensity modulated radiotherapy in thoracic esophageal cancer: a single institutional experience

  • Choi, Kyu Hye;Kim, Jina;Lee, Sea-Won;Kang, Young-nam;Jang, HongSeok
    • Radiation Oncology Journal
    • /
    • 제36권1호
    • /
    • pp.63-70
    • /
    • 2018
  • Purpose: The objective of this study was to compare dosimetric characteristics of three-dimensional conformal radiotherapy (3D-CRT) and two types of intensity-modulated radiotherapy (IMRT) which are step-and-shoot intensity modulated radiotherapy (s-IMRT) and modulated arc therapy (mARC) for thoracic esophageal cancer and analyze whether IMRT could reduce organ-at-risk (OAR) dose. Materials and Methods: We performed 3D-CRT, s-IMRT, and mARC planning for ten patients with thoracic esophageal cancer. The dose-volume histogram for each plan was extracted and the mean dose and clinically significant parameters were analyzed. Results: Analysis of target coverage showed that the conformity index (CI) and conformation number (CN) in mARC were superior to the other two plans (CI, p = 0.050; CN, p = 0.042). For the comparison of OAR, lung V5 was lowest in s-IMRT, followed by 3D-CRT, and mARC (p = 0.033). s-IMRT and mARC had lower values than 3D-CRT for heart $V_{30}$ (p = 0.039), $V_{40}$ (p = 0.040), and $V_{50}$ (p = 0.032). Conclusion: Effective conservation of the lung and heart in thoracic esophageal cancer could be expected when using s-IMRT. The mARC was lower in lung $V_{10}$, $V_{20}$, and $V_{30}$ than in 3D-CRT, but could not be proven superior in lung $V_5$. In conclusion, low-dose exposure to the lung and heart were expected to be lower in s-IMRT, reducing complications such as radiation pneumonitis or heart-related toxicities.

TeOx(22 1차원 광자결정의 광학 특성평가 (Optical Properties of TeOx(2x One-dimensional Photonic Crystals)

  • 공헌;여종빈;이현용
    • 한국전기전자재료학회논문지
    • /
    • 제27권12호
    • /
    • pp.831-836
    • /
    • 2014
  • One-dimensional (1D) photonic crystals (PCs) were prepared by $TeO_x(2<x<3)/SiO_2$ with the difference refractive index, and fabricated by sputtering technique from a $TeO_2$ and $SiO_2$ target. The $TeO_x$(2$Ar:O_2=40:10$). A 10-pair $TeO_x(2<x<3)/SiO_2$ 1D PCs were fabricated with the structure parameters of filling factor=0.5185, and period=410 nm. The properties of 1D PCs with and without a defect layer were evaluated by UV-VIS-NIR. A normal mode 1D PC have a photonic band gap (PBG) in the near infrared (NIR) region from 1,203 to 1,421 nm. In the case of 1D PC containing a defect layer, a defect level appears at 1,291 nm. The measured transmittance (T) spectra are nearly corresponding to calculated results. After He-Cd laser exposure, the defect level is shifted from 1,291 nm to 1,304 nm.

유방암 환자의 3D-CRT, TOMO 방법에 따른 선량 분포 평가 (Dosimetric Comparison of Three Dimensional Conformal Radiation Radiotherapy and Helical Tomotherapy Partial Breast Cancer)

  • 김대웅;김종원;최윤경;김정수;황재웅;정경식;최계숙
    • 대한방사선치료학회지
    • /
    • 제20권1호
    • /
    • pp.11-15
    • /
    • 2008
  • 목 적: 방사선치료계획에 있어서 정상조직과 치료부위의 선량 분포는 매우 중요하다. 이에 본원에서는 유방암 환자를 대상으로 Three-dimensional conformal radiation therapy (3D-CRT), Helical tomotherapy (TOMO)의 방법으로 방사선치료계획을 세웠으며 이에 선량분포를 분석하여 실제 임상에서의 적용여부를 알아보고자 한다. 대상 및 방법: 20명의(좌측: 10명, 우측: 10명) 유방보존절제술 환자를 대상으로 시행하였으며 방법으로는 같은 조건에서 3D-CRT는 Philips사의 Pinnacle을, TOMO는 TomoTherapy사의 TOMO Planning System을 이용해 치료계획을 세웠다. Dose-Volume Histogram (DVH)의 prescribed dose (PD)에 대한 PTV의 Homogeneity index (HI)와 Conformity index (CI)를 구하였고, 정상조직의 dose- volume 관계를 비교하였다. 결 과: Homogeneity index (HI)와 Conformity, index (CI)는 TOMO에서 우수한 결과를 나타났다. $V_{-50-IB-NPTV}$ (the percentage ipsilateral non-PTV breast volume that was delivered 50% of the prescribed dose)는 3D-CRT: 40.4%, TOMO: 18.3%, $V_{20-IL}$ (the average ipsilateral lung volume percentage receiving 20% of the prescribed dose)는 3D-CRT: 4.8%, TOMO: 14.2%, $V_{20-10H}$ (the average heart volume percentage delivered 20% and 10% of the prescribed dose in left breast cancer)는 3D-CRT: 1.6%, 3% TOMO: 9.7%, 26.3%의 결과를 보여준다. 결 론: 유방암 환자의 방사선치료계획 방법들은 PTV에서 원하는 선량분포를 보여줬다. 그러나 TOMO는 좋은 Homogeneity index (HI), Conformity index (CI)와 Breast를 보호하는 장점이 있는 반면에 Lung과 Heart에서는 많은 피폭선량이 있음을 알 수 있기에 TOMO의 방사선치료계획시 주의해야 할 점으로 사료된다.

  • PDF

Effects of Hypobaric Conditions on Apoptosis Signalling Pathways in HeLa Cells

  • Arican, Gul Ozcan;Khalilia, Walid;Serbes, Ugur;Akman, Gizem;Cetin, Idil;Arican, Ercan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권12호
    • /
    • pp.5043-5047
    • /
    • 2014
  • Nowadays increasing effectiveness in cancer therapy and investigation of formation of new strategies that enhance antiproliferative activity against target organs has become a subject of interest. Although the molecular mechanisms of apoptosis can not be fully explained, it is known that cell suicide program existing in their memory genetically is activated by pathophysiological conditions and events such as oxidative stress. Low pressure (hypobaric) conditions that create hypoxia promote apoptosis by inhibiting cell cycling. In this study, determination of the effects of fractional hypobaric applications at different times on HeLa cells at cellular and molecular levels were targeted. Experiments were carried out under hypobaric conditions (35.2 kPa) in a specially designed hypobaric cabin including 2% $O_2$ and 98% N. Application of fractional hypobaric conditions was repeated two times for 3 hours with an interval of 24 hours. At the end of the implementation period cells were allowed to incubate for 24 hours for activation of repair mechanisms. Cell kinetic parameters such as growth rate (MTT) and apoptotic index were used in determination of the effect of hypobaric conditions on HeLa cells. Also in our study expression levels of the Bcl-2 gene family that have regulatory roles in apoptosis were determined by the RT-PCR technique to evaluate molecular mechanisms. The results showed that antiproliferative effect of hypobaric conditions on HeLa cells started three hours from the time of application and increased depending on the period of exposure. While there was a significant decrease in growth rate values, there was a significant increase in apoptotic index values (p<0.01). Also molecular studies showed that hypobaric conditions caused a significant increase in expression level of proapoptotic gene Bax and significant decrease in antiapoptotic Bfl-1. Consequently fractional application of hypobaric conditions on HeLa cell cultures increased both antiproliferative and apoptotic effects and these effects were triggered by the Bax gene.

위험평가모형($TrophicTrace^{(R)}$)을 이용한 가상 해양오염퇴적물의 쥐노래미와 인체 영향 예비평가 (Potential Human Health and Fish Risks Associated with Hypothetical Contaminated Sediments Using a Risk Assessment Model ($TrophicTrace^{(R)}$))

  • 양동범;홍기훈;김경련
    • 대한환경공학회지
    • /
    • 제33권1호
    • /
    • pp.60-70
    • /
    • 2011
  • 본고에서는 현재 시행중인 해양오염퇴적물질 관리용 유해화학물질 정화지수($CI_{HC}$)를 대상으로, $CI_{HC}$은 동일하나 유해 물질별 함량이 다른 해저퇴적물들이 같은 생물위험을 보이는가를 판단하려 하였다. 이를 위해 5개의 가상 오염퇴적물을 설정하고, 퇴적물 위험평가를 위한 트로픽트레이스 모형($TrophicTrace^{(R)}$ model)을 이용하여, 이 가상 퇴적물이 쥐노래미(Hexagrammos otakii)에 대해 미치는 생물위험을 최대무작용량에 기반한 독성지수(NOAEL TQ)와 최소작용량에 기반한 독성지수(LOAEL TQ)로 평가하였다. 쥐노래미에 대한 NOAEL TQ의 합계는 5개 가상 오염퇴적물에서 0.69~1.54의 범위였고, LOAEL TQ의 합계는 0.111~0.261로 약 2배 이상의 차이가 났다. 이는 퇴적물 유해물질 환경기준이 해양저서무척추동물군집에 대한 영향만을 고려하고 사람으로 연결되는 식용의 쥐노래미에 대한 영향을 반영하지 않기 때문으로 사료된다. 인체에 대한 비발암위험지수(HI) 값은 PCB의 경우 9.8~47.1로 매우 위험한 것으로 나타났다. PCB의 발암위험도는 5개 퇴적물에서 $39{\sim}190{\times}10^{-5}$으로 높게 나타났으며 As의 경우에도 $8.1{\sim}18.0{\times}10^{-5}$으로 높게 나타났다. 유해화학물질정화지수가 8로 동일한 5개 가상 오염퇴적물에서 비발암위험지수(HI) 및 발암위험도가 서로 매우 다르게 나타난 것은 각 오염물질별로 인체에 악영향을 미치는 정도가 다르기 때문이다.

Liver CT 검사에서 프로토콜 변화에 따른 선량 감소와 영상의 질 개선에 관한 연구 (Improved Image Quality and Radiation Dose Reduction in Liver Dynamic CT Scan with the Protocol Change)

  • 조유진;조평곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권2호
    • /
    • pp.107-114
    • /
    • 2015
  • 간 역동적 CT(Liver Dynamic Computed Tomography; LDCT) 검사에서 일반적으로 사용하는 프로토콜과 관전압을 낮게 설정한 후 프로토콜을 변화시켰을 때 방사선량과 영상의 질을 비교하여 영상의 질을 유지하면서 방사선량을 감소시킬 수 있는 방안을 알아보고자 하였다. LDCT를 시행한 환자 중 신체질량지수(body mass index; BMI)가 18.5~24인 환자 40명을 대상으로 일반적인 복부 CT 검사 프로토콜을 적용한 A그룹 20명(관전압: 120 kVp, SAFIRE strength1)과 관전압을 낮게 설정한 B그룹 20명(관전압: 100 kVp, SAFIRE strength 0~5 적용)이었다. 영상의 질 평가는 동맥기의 간 실질 조직, 대동맥, 상장간막동맥, 복강동맥, 내장지방 그리고 백그라운드에 관심영역(region of interest; ROI)을 설정해 잡음(noise), 신호대 잡음비(signal to noise ratio; SNR), 대조도 대 잡음비(contrast to noise ratio; CNR), CT number를 측정 비교하였다. 또한 정성적 평가는 경험이 풍부한 영상의학과 전문의 2명이 0~3점까지로 평가하였다. 방사선량은 총 DLP(dose length product)와 유효선량, CTDIvol(volume computed tomography dose index)을 비교하였다. 관전압 100 kVp에서 SAFIRE가 높을수록 잡음은 감소하고, CT number는 증가하였다. 따라서 SNR과 CNR은 SAFIRE 단계가 높을수록 증가하였다. 관전압 120 kVp와 비교하여 잡음, SNR, CNR이 SAFIRE strength 2, 3에서 가장 유사하였다. 정성적 평가는 SAFIRE strength 2가 가장 많았고 관전압이 100 kVp일 때 영상의 질이 더 좋다고 평가한 경우는 SAFIRE 1이었다. 방사선량은 120 kVp에 비해 100 kVp에서 21.69% 감소하였다. BMI가 비교적 높지 않은 LDCT 검사의 경우 공장에서 출고될 당시에 관전압이 높게 설정되어 있어 불필요한 방사선피폭이 우려되고 있는 현실을 고려하면, 본 연구 결과에 따라 관전압을 낮게 설정하고 SAFIRE strength를 2로 조정하면 영상의 질 저하 없이 방사선량도 감소시킬 수 있을 것으로 사료된다.

Structural Similarity Index 인자를 이용한 방사선 분할 조사간 환자 체위 변화의 자동화 검출능 평가: 초기 보고 (Feasibility of Automated Detection of Inter-fractional Deviation in Patient Positioning Using Structural Similarity Index: Preliminary Results)

  • 윤한빈;전호상;이자영;이주혜;남지호;박달;김원택;기용간;김동현
    • 한국의학물리학회지:의학물리
    • /
    • 제26권4호
    • /
    • pp.258-266
    • /
    • 2015
  • 현대 방사선치료는 고선명 X선 투사영상을 이용하여 환자 및 종양의 위치를 확인하는 기술이 요구되지만, 3차원 영상 촬영을 위한 피폭량 및 영상정보의 급격한 증가는 환자에게 추가적인 부담이 될 수 있다. 본 연구에서는 영상의 구조 정보를 효과적으로 추출할 수 있는 Structural similarity (SSIM) 인자를 도입하여 매일 촬영하는 환자의 2차원 X선 영상간 차이를 자동 분석하여 환자의 위치 정확성의 검증 가능성을 제시하였다. 먼저 종양을 모사하기 위하여 구형 전산 팬텀의 크기와 위치를 변화시키면서 각각의 투사 영상을 시뮬레이션하고, SSIM 인자를 통해 영상 간 차이를 검출하여 분석하였다. 또한 12일간 매일 촬영한 방사선 치료 환자의 2차원 X선 영상들 간 차이를 동일한 방법으로 검출하였다. 그 결과 산출된 팬텀 변화에 따른 SSIM 값은 0.85~1 범위로, 관심영역(ROI)을 영상 전체가 아닌 팬텀으로 한정하였을 때는 0.006~1 범위로 나타나서 ROI 적용 시 민감도가 크게 상승하는 것을 확인하였다. 또한 임상 영상의 SSIM은 0.799~0.853 범위의 값을 나타냈으며 영상 간 차이가 SSIM 분포 상에 검출되는 것을 확인하였다. 본 연구결과는 소요 시간 및 피폭 등의 우려로 매일 사용하기 어려운 3차원 영상기법 대신 간단한 2차원 영상만을 이용하여 객관적이고 정량적인 환자 위치 정확성의 자동 평가 기법을 제공할 수 있을 것으로 기대된다.

식품을 통한 유기인계농약류의 동시노출위해성평가 (Cumulative Risk Assessment of Organophosphorus Pesticides in the Diet)

  • 이효민;한지연;윤은경;김효미;황인균;최동미;이강봉;원경풍;송인상
    • 한국식품위생안전성학회지
    • /
    • 제16권1호
    • /
    • pp.21-26
    • /
    • 2001
  • 유기인계 농약은 주로 수확률을 증가시킬 목적으로 과일, 채소, 곡류를 포함한 농산물에 사용하는 살충제로, 최근의 위해성평가기술은 독성기전이 동일한 물직들에 대해서 기준이 되는 물질의 특성을 1로하여 상대독성계수를 고려하므로 동시노출평가(cumulative risk assessment)를 수행하고 있다. 본 연구에서는 식품섭취를 통한 유기인계 농약의 동시다중노출에 기인된 위해정도를 판단하기 위하여 유기인계 농약과 다소비노출가능식품 등을 대상으로 cumulative risk assessment 를 실시코자 하였다. 펑가에 고려된 농약은 우리나라에서 사용빈도가 높은 농약(Acephate, Azinphos-methyl, Chlorpyrifos, Diazinon, Dimethoate, Ethion, Malathion, Methamidophos, Methidathion, Parathion-methyl, Phosmet, Pirimiphos-methyl) 12종이었고, 평가대상식품은 국내에서 유통되는 다소비식품을 위주로 곡류 4종(쌀, 보리, 밀, 옥수수), 과일류 5종(사과, 감, 밀감, 바나나, 배), 및 채소류 13종(배추, 양배추, 상추, 시금치, 오이, 토마토, 호박, 양파, 고추, 마늘, 무, 파, 당근)을 포함하여 총 22종의 식품을 대상으로 하였으며, 시료의 대표성을 부여하기 위하여 샘플링은 전국 4개 대도시(서울, 부산, 광주, 대전)를 대상으로 총2회 실시하였다. 12종의 유기인계 농약의 동시다중 노출에 대한 위해성평가를 위하여 노출평가시 TEF(독성등가치, Toxic Equivalency Factor) 방법을 적용하였고, FAO/WHO 의 만성인체노출평가방법을 기초로 우리나라 일반 성인을 대상으로 다수의 식품섭취를 통한 다수의 농약에 대한, 동시인체노출평가를 실시하였다. 노출의 안전수준을 결정하기 위해 필요한 독성값은 chlorpyrifos를 기준으로 하여 U.S.EPA 에서 제시한 AChE저해작용을 endpoint로 하는 RfD 값을 활용하였으며, 다수의 유기인계 농약으로부터 동시노출 되었을 때 나타날 수 있는 비발암독성에 대한 위해도를 결정하기 위하여 위험지수(Hazard Index, HI) 방법을 사용하였다.

  • PDF

좌측 유방암의 방사선치료 자세와 선량인자의 상관관계 분석 (Correlation analysis of radiation therapy position and dose factors for left breast cancer)

  • 전재완;박철우;홍종수;진성진;강정훈
    • 대한방사선치료학회지
    • /
    • 제29권1호
    • /
    • pp.37-48
    • /
    • 2017
  • 목 적: 방사선치료의 가장 기본적인 조건은 정상조직의 불필요한 피폭을 방지하는 것이다. 유방암의 경우는 폐와 심장에 조사되는 선량이 중요하게 평가되는 인자이다. 따라서 유방암 방사선치료 자세에 따른 정상조직에 조사되는 선량을 비교하고 그 연관성을 상관관계 분석을 통하여 결과를 확인하여 보다 효과적인 유방암 방사선 치료방법을 모색하고자 한다. 대상 및 방법: 본원을 내원한 좌측 유방암 환자 30명을 대상으로 Supine, Prone Position에서 CT image를 획득하였다. Eclipse Treatment Planning System(Version 11, USA)을 이용하여 전산화치료계획을 수립하였다. DVH(Dose Volume Histogram)을 통해 Position 별로 정상조직에 조사된 선량을 비교하였다. 그 결과를 바탕으로 SPSS(Version 18)을 이용하여 각 정상조직의 선량인자를 통계분석하고 항목 간 상관관계 분석 및 독립표본 t-test를 통하여 그 연관성을 알아보았다. 그리고 MIRADA RTx(Version Advanced 1.6, UK)를 이용하여 HI(Homogeneity Index)와 CI(Conformity Index)를 Supine, Prone Position에서 값을 구하고 비교하였다. 결 과: 유방암의 전산화치료계획의 결과 폐의 경우는 Supine Position에서 V20은 $16.5{\pm}2.6%$, V30은 $13.8{\pm}2.2%$, Mean dose는 $779.1{\pm}135.9cGy$(Absolute value)를 보였다. Prone Position은 위 순서대로 $3.1{\pm}2.2%$, $1.8{\pm}1.7%$, $241.4{\pm}138.3cGy$를 보였다. Prone Position이 전반적으로 낮은 선량을 나타내었고 평균선량 537.7 cGy가 더 적게 폐에 조사되었다. 심장의 경우에는 Supine, Prone 순서대로 V30은 $8.1{\pm}2.6%$, $5.1{\pm}2.5%$, Mean dose는 $594.9{\pm}225.3cGy$, $408{\pm}183.6cGy$를 보였다. Prone Position에서 평균선량 182.6 cGy가 더 적게 조사된다는 것을 확인하였다. 통계분석 결과 신뢰도 분석지표인 Cronbach's Alpha value는 0.563이였고 변수간의 상관관계분석 결과 치료자세와 폐의 선량평가인자는 대략 0.89 이상으로 그 상관관계가 높았다. 반면 심장의 경우는 V30은 0.488, Mean dose는 0.418로 상관관계가 다소 적었다. 마지막으로 독립표본 t-test 결과 치료자세와 폐, 심장의 선량평가인자가 신뢰수준 99 %에서 모두 유의하게 나타났다($p-value{\leq}0.05$). 결 론: 현재 방사선치료는 최첨단 선형가속기와 다양화된 전산화치료계획 기술이 개발되고 있다. 이 발전의 기본전제 조건은 PTV(Planning Target Volume) 주위의 정상조직 보호라고 생각한다. 물론 유방암 환자를 Prone Position에서 치료하면 Set-up의 재현성 문제와 다소 많은 시간이 소요되지만 이 실험결과에서 보듯이 Prone Position에서 폐와 심장에 들어가는 선량을 줄일 수 있으며 그 연관관계도 의미가 있다는 것을 확인하였다. 결론적으로 Prone Position에서 충분한 치료시간을 확보하고 정확한 치료부위 확인이 이루어진다면 환자에게 보다 좋은 방사선치료를 제공할 수 있다고 생각된다.

  • PDF