• Title/Summary/Keyword: Target Coverage

Search Result 303, Processing Time 0.03 seconds

Main Indicators of National Health Insurance during 40 Years (건강보험 40년의 주요 지표)

  • Lee, Sang Ah;Park, Eun-Cheol
    • Health Policy and Management
    • /
    • v.27 no.3
    • /
    • pp.267-271
    • /
    • 2017
  • This year marks the 40th anniversary of the introduction of National Health Insurance (NHI) which has contributed to improving public health and accessibility. This article aims to show the trends of main indicators during the last 40 years. NHI has achieved rapid expansion of target population (1977-1989). The percentage of population covered increased from 8.8% in 1977 to 94% in 1990. The average number of visit days per person was 0.75 in 1977 but significantly increased to 31.11 in 2015. In 2015, NHI revenues were 52.4 trillion won and expenditures were 48.2 trillion won which is 9.5 times and 9.6 times higher than in 1995. NHI achieved universal coverage in short period of time and has contributed to improving the healthcare status. However, there still remain problems including low-benefit coverage and high out of pocket money. Therefore, the effort to reform these problems is needed.

Analysis of Women's Jacket Sizing Systems of RTW Brands and Development of Sizing Systems by Age Groups (여성복 브랜드의 연령집단별 상의치수체계 비교분석 및 성인 여성의 연령집단별 치수체계 설정)

  • Baek, Hye Yoon;Song, Hwa Kyung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.42 no.6
    • /
    • pp.1056-1068
    • /
    • 2018
  • This study investigates whether women's wear brands' sizing systems reflect the body size and shape of their target age customers. This study classified 17 women's wear brands into three target age groups (20-30s, 30-40s, and 40-50s) and surveyed their body sizing systems for jacket items. The distribution of bust circumference and hip circumference of brands' sizing systems were compared with the size distribution of women in the 7th SizeKorea data. The brands targeting 20-30s fully produced five sizes which are the highest coverage rate, but the brands targeting 30-40s produced three sizes, and the brands targeting 40-50s produced one size. Regarding the body types, 60.0% of 20-30s target brands and 42.9% of 30-40s target brands reflected N type which is the average body type of each age group. However, the rest of the brands, including all 40-50s target brands, reflected A type which covered small portions of women. For each age group, 6 sizes with 24.0-29.0% coverage rates were proposed. With regard to the 88-94 size, three age groups overlapped: the 82-91 size was overlapped between the 20-30s and the 30-40s groups along with the 85-91 and 88-91 sizes that overlapped between the 30-40s and 40-50s groups.

Evaluation of Treatment Plan Quality between Magnetic Resonance-Guided Radiotherapy and Volumetric Modulated Arc Therapy for Prostate Cancer

  • Chang Heon Choi;Jin Ho Kim;Jaeman Son;Jong Min Park;Jung-in Kim
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.121-128
    • /
    • 2022
  • Purpose: This study evaluated the quality of plans based on magnetic resonance-guided radiotherapy (MRgRT) tri-Co-60, linac, and conventional linac-based volumetric modulated arc therapy (linac-VMAT) for prostate cancer. Methods: Twenty patients suffering from prostate cancer with intermediate risk who were treated by MAT were selected. Additional treatment plans (primary and boost plans) were generated based on MRgRT-tri-Co-60 and MRgRT-linac. The planning target volume (PTV) of MRgRT-based plans was created by adding a 3 mm margin from the clinical target volume (CTV) due to high soft-tissue contrast and real-time motion imaging. On the other hand, the PTV of conventional linac was generated based on a 1 cm margin from CTV. The targets of primary and boost plans were prostate plus seminal vesicle and prostate only, respectively. All plans were normalized to cover 95% of the target volume by 100% of the prescribed dose. Dosimetric characteristics were evaluated for each of the primary, boost, and sum plans. Results: For target coverage and conformity, the three plans showed similar results. In the sum plans, the average value of V65Gy of the rectum of MRgRT-linac (2.62%±2.21%) was smaller than those of MRgRT tri-Co-60 (9.04%±3.01%) and linac-VMAT (9.73%±7.14%) (P<0.001). In the case of bladder, the average value of V65Gy of MRgRT-linac was also smaller. Conclusions: In terms of organs at risk sparing, MRgRT-linac shows the best value while maintaining comparable target coverage among the three plans.

Convolution-Superposition Based IMRT Plan Study for the PTV Containing the Air Region: A Prostate Cancer Case (Convolution-Superposition 알고리즘을 이용한 치료계획시스템에서 공기가 포함된 표적체적에 대한 IMRT 플랜: 전립선 케이스)

  • Kang, Sei-Kwon;Yoon, Jai-Woong;Park, Soah;Hwang, Taejin;Cheong, Kwang-Ho;Han, Taejin;Kim, Haeyoung;Lee, Me-Yeon;Kim, Kyoung Ju;Bae, Hoonsik
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.271-277
    • /
    • 2013
  • In prostate IMRT planning, the planning target volume (PTV), extended from a clinical target volume (CTV), often contains an overlap air volume from the rectum, which poses a problem inoptimization and prescription. This study was aimed to establish a planning method for such a case. There can be three options in which volume should be considered the target during optimization process; PTV including the air volume of air density ('airOpt'), PTV including the air volume of density value one, mimicking the tissue material ('density1Opt'), and PTV excluding the air volume ('noAirOpt'). Using 10 MV photon beams, seven field IMRT plans for each target were created with the same parameter condition. For these three cases, DVHs for the PTV, bladder and the rectum were compared. Also, the dose coverage for the CTV and the shifted CTV were evaluated in which the shifted CTV was a copied and translated virtual CTV toward the rectum inside the PTV, thus occupying the initial position of the overlap air volume, simulating the worst condition for the dose coverage in the target. Among the three options, only density1Opt plan gave clinically acceptable result in terms of target coverage and maximum dose. The airOpt plan gave exceedingly higher dose and excessive dose coverage for the target volume whereas noAirOpt plan gave underdose for the shifted CTV. Therefore, for prostate IMRT plan, having an air region in the PTV, density modification of the included air to the value of one, is suggested, prior to optimization and prescription for the PTV. This idea can be equally applied to any cases including the head and neck cancer with the PTV having the overlapped air region. Further study is being under process.

A Single Mobile Target Tracking in Voronoi-based Clustered Wireless Sensor Network

  • Chen, Jiehui;Salim, Mariam B.;Matsumoto, Mitsuji
    • Journal of Information Processing Systems
    • /
    • v.7 no.1
    • /
    • pp.17-28
    • /
    • 2011
  • Despite the fact that the deployment of sensor networks and target tracking could both be managed by taking full advantage of Voronoi diagrams, very little few have been made in this regard. In this paper, we designed an optimized barrier coverage and an energy-efficient clustering algorithm for forming Vonoroi-based Wireless Sensor Networks(WSN) in which we proposed a mobile target tracking scheme (CTT&MAV) that takes full advantage of Voronoi-diagram boundary to improve detectability. Simulations verified that CTT&MAV outperforms random walk, random waypoint, random direction and Gauss-Markov in terms of both the average hop distance that the mobile target moved before being detected and lower sensor death rate. Moreover, we demonstrate that our results are robust as realistic sensing models and also validate our observations through extensive simulations.

An Analysis of the Fake News Assessment Criteria on Fact-check Coverage (팩트체크 보도의 가짜뉴스 판단 기준 검토)

  • Baek, Kanghui
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.2
    • /
    • pp.172-181
    • /
    • 2020
  • This study examines the fact-check coverage provided by the SNU fact-check center site(factcheck.snu.ac.kr). A total of 50 articles that were cross-checked by multiple news media organizations were analyzed. The study's variables were topics, types, characteristics, consistency of the news media organizations' judgement, and fact-check sources. This study found that fact-checking coverage was generally focused on presidential or general election candidates or politicians, as well as political topics. The types of fact-checking coverage primarily included factual information, as well as some opinions or interpretations. Fact-check coverage was mainly focused on the facts of the statements themselves, causal relationships, or the timing or target of the comparison criteria. On average, the fact-checking coverage most frequently assigned the judgment 'mostly false, and primarily used interviews of individuals or data from organizations involved in the issue, government data, and experts' statements as the bases for its fact-checking judgements.

Optimum Field Size for the Whole Body Stereotactic Radiosurgery (전신 정위 방사선 치료시의 적정 조사면 크기)

  • 이병용;민철기;정원규;최은경
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.15-20
    • /
    • 2002
  • Optimum field size for the whole body stereotactic radiosurgery was studied. Dose distributions from the various sizes of targets (diameter 1cm to 7cm, icm interval) were used for this study. Planing scores, expressed as the Target Coverage Index (TCI), were calculated for various target Margin ranged 0cm to 0.5cm. Highest scores were obtained for no Margin to the target size. The target Margin -0.5cm to 0cm to the target showed best TCI the cases of the target size larger than 6cm diameter. No Margin or 0.5cm Margin generated best TCI for less than 2cm cases. Prescription to 80~90% gives best results.

  • PDF

Optimal Allocation Model of Anti-Artillery Radar by Using ArcGIS and its Specifications (지형공간정보와 제원 특성을 적용한 대포병레이더 최적배치모형)

  • Lee, Moon Gul
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.2
    • /
    • pp.74-83
    • /
    • 2018
  • It is very crucial activities that Korean army have to detect and recognize enemy's locations and types of weapon of their artillery firstly for effective operation of friendly force's artillery weapons during wartime. For these activities, one of the most critical artillery weapon systems is the anti-artillery radar (hereafter; radars) for immediate counter-fire operations against the target. So, in early wartime these radar's roles are very important for minimizing friendly force's damage because arbiters have to recognize a several enemy's artillery positions quickly and then to take an action right away. Up to date, Republic of Korea Army for tactical artillery operations only depends on individual commander's intuition and capability. Therefore, we propose these radars allocation model based on integer programming that combines ArcGIS (Geographic Information System) analysis data and each radar's performances which include allowable specific ranges of altitude, azimuth (FOV; field of view) and distances for target detection, and weapons types i.e., rocket, mortars and cannon ammo etc. And we demonstrate the effectiveness of their allocation's solution of available various types of radar asset through several experimental scenarios. The proposed model can be ensured the optimal detection coverage, the enhancement of artillery radar's operations and assisting a quick decision for commander finally.

New Lung Cancer Panel for High-Throughput Targeted Resequencing

  • Kim, Eun-Hye;Lee, Sunghoon;Park, Jongsun;Lee, Kyusang;Bhak, Jong;Kim, Byung Chul
    • Genomics & Informatics
    • /
    • v.12 no.2
    • /
    • pp.50-57
    • /
    • 2014
  • We present a new next-generation sequencing-based method to identify somatic mutations of lung cancer. It is a comprehensive mutation profiling protocol to detect somatic mutations in 30 genes found frequently in lung adenocarcinoma. The total length of the target regions is 107 kb, and a capture assay was designed to cover 99% of it. This method exhibited about 97% mean coverage at $30{\times}$ sequencing depth and 42% average specificity when sequencing of more than 3.25 Gb was carried out for the normal sample. We discovered 513 variations from targeted exome sequencing of lung cancer cells, which is 3.9-fold higher than in the normal sample. The variations in cancer cells included previously reported somatic mutations in the COSMIC database, such as variations in TP53, KRAS, and STK11 of sample H-23 and in EGFR of sample H-1650, especially with more than $1,000{\times}$ coverage. Among the somatic mutations, up to 91% of single nucleotide polymorphisms from the two cancer samples were validated by DNA microarray-based genotyping. Our results demonstrated the feasibility of high-throughput mutation profiling with lung adenocarcinoma samples, and the profiling method can be used as a robust and effective protocol for somatic variant screening.

A study on design of instantaneous field of view of rosette scanning infrared seeker (로젯 주사 적외선 탐색기의 순시 시계 설계에 관한 연구)

  • 장성갑;홍현기;한성현;최종수
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.7
    • /
    • pp.86-94
    • /
    • 1998
  • The rosette-scan seeker is a device mounted on the infrared guided missile. It offers the positions and iamges of target to missiles servo system by scanning a space about target in rosette pattern with a single detector. An instantaneous field of view (IFOV), which is a diameter of a detector moving along the path of the rosette pattern, has the property that its smaller size provide the less interference of background signals and detector noise. If its size is too small to voer the total field of view (TFOV), however, it produces the invisible regions in the TFOV. In this case, the invisible regions cause the performance of the seeker to deteriorate. For full scan-coverage, it is necessary to design the small IFOV without the invisible regions in the TFOV, as possible. In this paper, we propose the new method of designing the smaller IFOV than the conventional method and verify full coverage of the scanned region. By comparing the nose equivalent flux density (NEFD) of the proposed method with the that of the conventional one, we confirm that the former is better than the latter in terms of performance.

  • PDF