• Title/Summary/Keyword: Target

Search Result 24,960, Processing Time 0.064 seconds

Development and Evaluation of Consumer Educational Contents on Hazard Chemicals in Food for Female College Students in Seoul (식품 중 유해물질에 대한 소비자 교육 콘텐츠 개발 및 교육효과 조사 -서울에 거주하는 여대생을 중심으로-)

  • Cho, Sun-Duk;Kang, Eun-Jin;Kim, Meehye;Park, Sung-Kug;Paek, Ock-Jin;Kim, Gun-Hee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.10
    • /
    • pp.1701-1706
    • /
    • 2013
  • Domestic and overseas information with regard to harmful substances are analyzed. From the results, environmental-derived hazard chemicals, which show relatively low recognition, and hazard chemicals that occur unavoidably in food manufacturing process are selected as target harmful substances. Thus, educational leaflet contents were developed based on these substances. To find the effects of education with the above contents, this study surveyed 120 female college students living in Seoul. The purpose of the survey is to analyze the change in recognition, attitude and behavior on hazard chemicals in foods. The survey found that the recognition on harmful substance in foods increased; from 31.5~78.0% before education to 98.8% after education. It also indicates that vague anxiety in which the harmful substances may damage their health decreased by approx. 25.0%; from 77.8% before education to 52.8% after education. For the question of what they would do when government promotes to reduce harmful substances in foods, 12.3% of respondents said that they would actively follow the suggestions and 73.5% of them said that they would do their best before an education. However, 56.1% of them said that they would actively follow the suggestions after the education. It indicates that the ability to recognize harmful substances changed after the education. With regard to consumer behavior, when they knew about the harmful substances in foods, 49.6% of them said that they would select foods after investigating relevant information before the education, while 77.4% of them said that after the education; which is an increase of 27.8%. Further, 45.4% of them said that they would not purchase relevant foods before the education, while 20.9% of them said that after the education; which is a decrease of 24.5%. Therefore, it is considered that vague anxiety of consumers can be eliminated by providing persuasive information on harmful substances. To expand on the communication channel with consumers for food safety, contents development and educational promotion should be enhanced for providing food safety related information.

A Study on the Interpretation of Cultural Heritage Sites for Public Education (대중교육을 위한 문화유적의 해석(Interpretation)에 관한 기본연구)

  • Han, Sang-U
    • KOMUNHWA
    • /
    • no.68
    • /
    • pp.41-57
    • /
    • 2006
  • The purpose of this study is to review educational value of cultural heritage sites first and then, to examine the importance of interpretation and interpretation methods and process briefly to utilize cultural heritage sites as important resources for public education and cultural tourism. The educational value of cultural heritage sites is not limited to provide visitors with various information on historical facts and events related to the cultural heritage site, but to provide the public with a new recognition of the importance of the preservation of cultural heritage sites by understanding the site well. In order to utilize the educational value of the cultural heritage site, interpretation must be emphasized as an important element of cultural heritage sites management and much attention should be given on the development and practice of interpretation programs in each cultural heritage site. In order to develop an interpretation program of the site, a specific target audience must be defined first to find most resonable scope and direction of an interpretation program and then, site specific interpretation themes (or a theme) should be developed from the interpretive topic. According to these defined elements, an interpretation program(s) is established by using various interpretation methods and techniques in order to provide visitors with useful information and knowledge on the site efficiently. Interpretation methods and techniques are various as defined by various ways and most effective methods or techniques are employed as a specific interpretation program is presented most effectively. The evaluation processes in planing stage, during developing stage, and after completion of interpretation program development are important processes to find out any problems of planed interpretation program and to revise or update the interpretation program. Conclusively, the direction of cultural heritage sites management in Korea has focused on the conservation and restoration of cultural heritage sites to preserve the original conditions of cultural heritage sites so far. This direction on current practice on cultural heritage sites management should he changed to more active utilization of the sites and interpretation of the sites is a way to accomplish the this goal.

  • PDF

Clinical Significance of Nasal Peak Inspiratory Flow Rate in Patients with Chronic Cough (만성기침환자에서 비강최대흡기유속 측정의 의의)

  • An, Chang-Hyeok;Lee, Byung-Hun;Park, Yong-Bum;Choi, Jae-Chul;Jee, Hyun-Suk;Park, Sung-Jin;Kang, Sun-Bok;Kim, Jae-Yeol;Park, In-Won;Choi, Byung-Whi;Hue, Sung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.654-661
    • /
    • 1999
  • Background : The upper respiratory tract is the primary target organ of various airborne pollutants and is easily accessible part of the respiratory tract, and also is the predominant structure where chronic cough originates. The nasal peak inspiratory flow(PIFn), which is the peak inspiratory flow via nose with nasal mask and spirometry, could be a reliable parameter of nasal obstruction. The validity of PIFn has been evaluated in several studies by assessing the correlation between PIFn measurements and other parameters of nasal air flow. This study was designed to show the reproducibility of PIFn, the difference of PIFn between patients with chronic cough and normal subjects, and the usefulness of PIFn in the evaluation of nasal obstruction in patients with chronic cough. Methods : PIFn was measured by spirometry with nasal mask, twice a day for 3 consecutive days in 7 young normal subjects to evaluate validity of the test. In 32 patients with chronic cough and 25 age-matched normal subjects, PIFn and pulmonary function test($FEV_1$, $FEV_1%$ pred, FVC, and FVC% pred) were measured at first visiting. Results : Values of PIFn, $FEV_1$, and FVC were nearly constant in 7 young normal adults. Patients with chronic cough were 32 (14 males and 18 females) and the mean age was $41.4{\pm}15.9$ years. Normal subjects were 32(22 males and 10 females) and the mean age was $39.8{\pm}18.6$ years. There was no significant difference of age and pulmonary function test between patients with chronic cough and normal subjects(p<0.05). The PIFn values in patients with chronic cough was significantly lower than those of normal subjects($2.25{\pm}0.68\;L/sec$ vs. $2.75{\pm}1.00\;L/sec$ ; p=0.02). The postnasal drip syndrome(PNDS) comprised the majority of patients with chronic cough(27). The PIFn in patients with PNDS was significantly lower than that of normal subjects (mean$\pm$SD ; $2.18{\pm}0.66$ vs. $2.75{\pm}1.00\;L/sec$, p=0.006). Conclusion : There was a significant difference of PIFn between patients with chronic cough and normal subjects. Among the patients with chronic cough, patients with PNDS showed the most significant difference with normal subjects in PIFn. The PIFn could be a useful parameter of nasal obstruction in patients with chronic cough, especially in patients with PNDS.

  • PDF

Effect of Market Basket Size on the Accuracy of Association Rule Measures (장바구니 크기가 연관규칙 척도의 정확성에 미치는 영향)

  • Kim, Nam-Gyu
    • Asia pacific journal of information systems
    • /
    • v.18 no.2
    • /
    • pp.95-114
    • /
    • 2008
  • Recent interests in data mining result from the expansion of the amount of business data and the growing business needs for extracting valuable knowledge from the data and then utilizing it for decision making process. In particular, recent advances in association rule mining techniques enable us to acquire knowledge concerning sales patterns among individual items from the voluminous transactional data. Certainly, one of the major purposes of association rule mining is to utilize acquired knowledge in providing marketing strategies such as cross-selling, sales promotion, and shelf-space allocation. In spite of the potential applicability of association rule mining, unfortunately, it is not often the case that the marketing mix acquired from data mining leads to the realized profit. The main difficulty of mining-based profit realization can be found in the fact that tremendous numbers of patterns are discovered by the association rule mining. Due to the many patterns, data mining experts should perform additional mining of the results of initial mining in order to extract only actionable and profitable knowledge, which exhausts much time and costs. In the literature, a number of interestingness measures have been devised for estimating discovered patterns. Most of the measures can be directly calculated from what is known as a contingency table, which summarizes the sales frequencies of exclusive items or itemsets. A contingency table can provide brief insights into the relationship between two or more itemsets of concern. However, it is important to note that some useful information concerning sales transactions may be lost when a contingency table is constructed. For instance, information regarding the size of each market basket(i.e., the number of items in each transaction) cannot be described in a contingency table. It is natural that a larger basket has a tendency to consist of more sales patterns. Therefore, if two itemsets are sold together in a very large basket, it can be expected that the basket contains two or more patterns and that the two itemsets belong to mutually different patterns. Therefore, we should classify frequent itemset into two categories, inter-pattern co-occurrence and intra-pattern co-occurrence, and investigate the effect of the market basket size on the two categories. This notion implies that any interestingness measures for association rules should consider not only the total frequency of target itemsets but also the size of each basket. There have been many attempts on analyzing various interestingness measures in the literature. Most of them have conducted qualitative comparison among various measures. The studies proposed desirable properties of interestingness measures and then surveyed how many properties are obeyed by each measure. However, relatively few attentions have been made on evaluating how well the patterns discovered by each measure are regarded to be valuable in the real world. In this paper, attempts are made to propose two notions regarding association rule measures. First, a quantitative criterion for estimating accuracy of association rule measures is presented. According to this criterion, a measure can be considered to be accurate if it assigns high scores to meaningful patterns that actually exist and low scores to arbitrary patterns that co-occur by coincidence. Next, complementary measures are presented to improve the accuracy of traditional association rule measures. By adopting the factor of market basket size, the devised measures attempt to discriminate the co-occurrence of itemsets in a small basket from another co-occurrence in a large basket. Intensive computer simulations under various workloads were performed in order to analyze the accuracy of various interestingness measures including traditional measures and the proposed measures.

The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams (6MV 광자선에서 측정 조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교)

  • 김회남;박성용;서태석;권수일;윤세철
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.87-102
    • /
    • 1997
  • The absolute absorbed dose can be determined according to the measurement conditions; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of 10cm $\times$ 10cm field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations of phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG21 and IAEA protocol. The differences between two protocols are within 1% while the average value of IAEA protocol was 0.5% smaller than TG21 protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within 1%, but individual discrepancies are in the range of - 2.5% to 1.2% depending upon the choice of measurement combination. The largest discrepancy of - 2.5% was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coeficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, it shows that absorbed dose could be affected by phantom material other than water.

  • PDF

Feasibility of Automated Detection of Inter-fractional Deviation in Patient Positioning Using Structural Similarity Index: Preliminary Results (Structural Similarity Index 인자를 이용한 방사선 분할 조사간 환자 체위 변화의 자동화 검출능 평가: 초기 보고)

  • Youn, Hanbean;Jeon, Hosang;Lee, Jayeong;Lee, Juhye;Nam, Jiho;Park, Dahl;Kim, Wontaek;Ki, Yongkan;Kim, Donghyun
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.258-266
    • /
    • 2015
  • The modern radiotherapy technique which delivers a large amount of dose to patients asks to confirm the positions of patients or tumors more accurately by using X-ray projection images of high-definition. However, a rapid increase in patient's exposure and image information for CT image acquisition may be additional burden on the patient. In this study, by introducing structural similarity (SSIM) index that can effectively extract the structural information of the image, we analyze the differences between daily acquired x-ray images of a patient to verify the accuracy of patient positioning. First, for simulating a moving target, the spherical computational phantoms changing the sizes and positions were created to acquire projected images. Differences between the images were automatically detected and analyzed by extracting their SSIM values. In addition, as a clinical test, differences between daily acquired x-ray images of a patient for 12 days were detected in the same way. As a result, we confirmed that the SSIM index was changed in the range of 0.85~1 (0.006~1 when a region of interest (ROI) was applied) as the sizes or positions of the phantom changed. The SSIM was more sensitive to the change of the phantom when the ROI was limited to the phantom itself. In the clinical test, the daily change of patient positions was 0.799~0.853 in SSIM values, those well described differences among images. Therefore, we expect that SSIM index can provide an objective and quantitative technique to verify the patient position using simple x-ray images, instead of time and cost intensive three-dimensional x-ray images.

Effect of Low Magnetic Field on Dose Distribution in the Partial-Breast Irradiation (부분유방 방사선조사 시 저자기장이 선량분포에 미치는 영향)

  • Kim, Jung-in;Park, So-Yeon;Lee, Yang Hoon;Shin, Kyung Hwan;Wu, Hong-Gyun;Park, Jong Min
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.208-214
    • /
    • 2015
  • The aim of this study is to investigate the effect of low magnetic field on dose distribution in the partial-breast irradiation (PBI). Eleven patients with an invasive early-stage breast carcinoma were treated prospectively with PBI using 38.5 Gy delivered in 10 fractions using the $ViewRay^{(R)}$ system. For each of the treatment plans, dose distribution was calculated with magnetic field and without magnetic field, and the difference between dose and volume for each organ were evaluated. For planning target volume (PTV), the analysis included the point minimum ($D_{min}$), maximum, mean dose ($D_{mean}$) and volume receiving at least 90% ($V_{90%}$), 95% ($V_{95%}$) and 107% ($V_{107%}$) of the prescribed dose, respectively. For organs at risk (OARs), the ipsilateral lung was analyzed with $D_{mean}$ and the volume receiving 20 Gy ($V_{20\;Gy}$), and the contralateral lung was analyzed with only $D_{mean}$. The heart was analyzed with $D_{mean}$, $D_{max}$, and $V_{20\;Gy}$, and both inner and outer shells were analyzed with the point $D_{min}$, $D_{max}$ and $D_{mean}$, respectively. For PTV, the effect of low magnetic field on dose distribution showed a difference of up to 2% for volume change and 4 Gy for dose. In OARs analysis, the significant effect of the magnetic field was not observed. Despite small deviation values, the average difference of mean dose values showed significant difference (p<0.001), but there was no difference of point minimum dose values in both sehll structures. The largest deviation for the average difference of $D_{max}$ in the outer shell structure was $5.0{\pm}10.5Gy$ (p=0.148). The effect of low magnetic field of 0.35 T on dose deposition by a Co-60 beam was not significantly observed within the body for PBI IMRT plans. The dose deposition was only appreciable outside the body, where a dose build-up due to contaminated electrons generated in the treatment head and scattered electrons formed near the body surface.

The Output Factor of Small Field in Multileaf Collimator of 6 MV Photon Beams (다엽제한기 소조사면의 6 MV 광자선 출력선량계수)

  • Lee, Ho Joon;Choi, Tae-Jin;Oh, Young Kee;Jeun, Kyung Soo;Lee, Yong Hee;Kim, Jin Hee;Kim, Ok Bae;Oh, Se An;Kim, Sung Kyu;Ye, Ji Woon
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • The IMRT is proper implement to get high dose deliver to tumor as its shape and selective approach in radiation therapy. Since the IMRT is performed as modulated the radiation fluence by the MLC created the open shapes and its irradiation time, the dose of segment of radiation field effects on the cumulated portal dose. The accurate output factor of small and step shape of segment is important to improve the determination of deliver tumor dose as it is directly proportional to dose. This experiment performed with the 6 MV photon beam of Clinac Ex(Varian) from $3{\times}3cm^2$ to $0.5{\times}0.5cm^2$ small field size for collimator jaw in MLC free and/or for MLC open field in fixed collimator jaw $10{\times}10cm^2$ using the CC01 ion chamber, SFD diode, diamond detector and X-Omat film dosimetry. As results of normalized to the reference field of $10{\times}10cm^2$ of MLC, the output factor of $3{\times}3cm^2$ showed $0.899{\pm}0.0106$, $0.855{\pm}0.0106$ for $2{\times}2cm^2$, $0.764{\pm}0.0082$ for $1{\times}1cm^2$ and $0.602{\pm}0.0399$ for $0.5{\times}0.5cm^2$. The output factor of MLC open field has shown a maximum 3.8% higher than that of the collimator jaw open field.

Comparison between Response AC/A and CA/C Ratio according to Additional Spherical Powers and Prism Powers (가입렌즈 도수와 프리즘 굴절력 변화에 따른 반응 AC/A비와 CA/C비 비교)

  • Roh, Byeong-Ho;Yu, Dong-Sik;Son, Jeong-Sik;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.341-347
    • /
    • 2015
  • Purpose : This study was to examine a correlation of response AC/A ratio by additional spherical powers with PD(Pupilary distance) and relative accommodation, and was to investigate correlation of CA/C ratio by prism powers. The mean differences between a reciprocal response AC/A ratio and a CA/C ratio were compared, and were suggested to be used as data in the refractive power and prism prescriptions in the clinical. Methods: The open field autorefractometer (Nvision-K 5001, Shin nippon) and Howell target at 40 cm fixation distance to 62 persons with average $22.62{\pm}2.84$ ages were used to measure the response AC/A ratio according to additional Spherical powers. The CA/C ratios were measured using the DOG card at 40cm according to prism powers. Results: When the response accommodation according to Additional Spherical power changes and the response accommodation according to prism power changes were compared, it was larger than the response accommodation according prism power change. These were significant differences statistically. The correlation of response AC/A ratio and PD is showed as r = -0.158, the CA / C ratio is shown as r = 0.093. The correlation of response AC/A ratio and relative accommodation showed as r = -0.253, the CA/C ratio showed as r = 0.566 that is predictable correlation. The correlation of response AC/A ratio and CA/C ratio showed as r = -0.355 that is low minus correlation (p = 0.000). The difference between a reciprocal response AC/A ratio and a CA/C ratio showed $0.12{\pm}0.06D/{\Delta}$ with a significant difference statistically (p=0.000). Conclusions: The correlation of relative accommodation and CA/C ratio showed that depend on the individual, The more a relative accommodation is, the higher a response accommodation of convergence by convergence stimulus is. The reciprocal response AC/A and CA/C ratio showed significant differences statistically. This can have higher CA/C ratio in patients with low AC/A ratio in clinical as an independent variable. Thus when the abnormal binocular vision was prescribed in the clinical, it is necessary to consider the accommodative response even if the AC/A ratio is a normal range.

Correlation of Near Stereoacuity and Phoria, and Refractive Error (근거리 입체시와 사위 및 굴절이상의 상관관계)

  • Shim, Hyun-Suk;Kim, Sang-Hyun;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.1
    • /
    • pp.67-73
    • /
    • 2015
  • Purpose: This study was investigated the relationship between the male and female of near stereoacuity and phoria, and was examined the correlations between near stereoacuity and phoria and refractive error. Methods: Adult 83 (male 36, female 47, mean age $21.09{\pm}1.74$(19~29) years old) target was examined after full correction of refractive error. Near stereoacuity was measured by using Titmus-fly Stereotest(Stereo Optical Co., Inc., Chicago, IL, USA), and RANDOT Stereotest (Stereo Optical Co., Inc., Chicago, IL, USA), phoria was measured by using modified torrington method, at distance 40 cm. Results: In near stereoacuity, male was better good than female, and there was no difference between male and female (p>0.05). In near phoria, female was more higher than male, and there was a significant difference between male and female (p<0.05). Near stereoacuity by Titmus-fly test and Randot test result respectively was $262.17{\pm}562.43$ sec (second of arc) $243.08{\pm}68.04$ sec in esophoria, $148.42{\pm}269.54$ sec, $107.40{\pm}263.74$ sec in orthophoria, $113.94{\pm}152.46$ sec, $79.70{\pm}136.83$ sec in exophoria, there was a no difference between three phoria groups (p>0.05), and was a high correlation between phoria and near stereoacity(r=0.68). In addition, near stereoacuity in the refractive error respectively was $80.00{\pm}571.43$ sec, $68.75{\pm}36.82$ sec in myopia, $133.57{\pm}224.15$ sec, $93.14{\pm}214.95$ sec in hyperopia, $511.20{\pm}855.00$ sec, $511.4{\pm}855.60$ sec, there was a significant difference between three phoria groups (p<0.05). when was classfiied near stersoacuity into degree of refractive error, near stersoacuity was best in emmetropia, and was reduced when refractive error was highest in high degree myopia, and hyperopia. Conclusions: Titmus-fly Stereotest and RANDOT Stereotest result, near stereoacuity of adults, when esophoria and high degree refractive error, was reduced, there was a relationship between near stereoacuity with phoria, and refractive error. In this both stereotests if was bad when near stereoacuity can expect a phoria and refractive error.