• Title/Summary/Keyword: Tapping test

Search Result 77, Processing Time 0.026 seconds

Measurement and Comparison of Finger Tapping Movement in Patients with Idiopathic Parkinson's Disease and Normal Subjects using Gyrosensor (자이로센서를 이용한 특발성 파킨슨병 환자와 정상인의 손가락 벌렸다 오므리기 동작의 측정과 비교)

  • Kim, Ji-Won;Kwon, Yu-Ri;Lee, Jae-Ho;Eom, Gwang-Moon;Kwon, Do-Young;Koh, Seong-Beom;Park, Byung-Kyu;Hong, Jung-Hwa
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.240-244
    • /
    • 2010
  • The purpose of this study is to compare finger tapping (FT) movement of patients with Parkinson's disease (PD) with normal subjects. A gyrosensor system was used for the measurement of FT movement, because it provides angular velocity free from the gravitational artifact and it can be used during clinical FT test listed in unified PD rating scale (UPDRS). Forty PD patients (age: 65.7 ${\pm}$ 11.1 yrs, H&Y stage:2.3 ${\pm}$ 0.5), 14 age-matched elderly subjects (65${\pm}$3.9 yrs) and 17 healthy young subjects (24${\pm}$2.1yrs) participated in this study. Angular velocity of finger tapping movement was measured in both right and left index finger. As quantitative measures, root-mean-squared (RMS) angular velocity, RMS angle, peak power and total power were used. ANOVA showed that all measures were significantly different among three groups (p<0.001) in all quantitative measures. Post-hoc test revealed that all quantitative measures except peak power in patients with PD were significantly smaller than in both healthy elderly and young subjects (p<0.01). This suggests that the measures developed in this study can distinguish patients with PD from normal subjects.

Correlation Between Rhythm Reproduction Task Performance and Cognitive Function in School-Aged Children (초등학생의 리듬 재산출 능력과 인지기능 수준 간 상관관계)

  • Oh, So-young;Chong, Hyun Ju
    • Journal of Music and Human Behavior
    • /
    • v.13 no.1
    • /
    • pp.1-18
    • /
    • 2016
  • This study examined the correlation between the rhythm reproduction performance and cognitive function of school-aged children. A total of 59 third grade elementary students participated in this study. An iPad-based rhythm reproduction task, the Digit Span Test (DST), the Children's Color Trails Test (CCTT), and a self-paced tapping task via a MIDI keyboard were conducted for each participant. The results demonstrated that scores at each stage of the iPad-based rhythm reproduction test showed different patterns of correlation with cognitive function test scores. This result suggests that accuracy of a simple rhythm task is correlated to speed of self-paced tapping (second). Also cognitive function may affect rhythm grouping ability. Results of this analysis for each of 20 rhythm items showed that there was a common rhythm characteristics that correlated with executive function, working memory or self-paced tapping speed. These results indicate that rhythm ability is related to, and predictive of, the level of cognitive functioning in elementary school students and can be used as an useful parameter when examining cognitive function of school-aged children in multifaceted dimensions.

Analysis of Angular Velocity during Toe Tapping for the Quantification of the Lower Limb Bradykinesia in Patients with Idiopathic Parkinson's Disease (특발성 파킨슨병 환자의 하지 완서증 정량화를 위한 발 두드리기 동작의 각속도 분석)

  • Kim, Ji-Won;Kwon, Yu-Ri;Eom, Gwang-Moon;Kim, Hyung-Sik;Yi, Jeong-Han;Kwon, Do-Young;Koh, Seong-Beom;Park, Byung Kyu;Kwon, Tae-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.2114-2118
    • /
    • 2010
  • The purpose of this study was to analyze bradykinesia of toe tapping movement in patients with Parkinson's disease (PD) as compared to those of normal subjects. 39 PD patients (age: $65.5{\pm}11.2$ yrs, H&Y stage:$2.3{\pm}0.5$), 14 eldelry subjects with comparable mean age ($65.0{\pm}3.9$ yrs) and 17 healthy young subjects ($24.1{\pm}2.1$ yrs) participated in this study. Angular velocity during repetitive toe tapping movement was measured in both feet using a gyro sensor system. Suggested quantitative measures of bradykinesia were root-mean-squared (RMS) angular velocity, RMS angle, peak power and total power which were derived from the angular velocity signal. ANOVA showed that all measures were significantly different among three groups (p<0.001). Subsequent post-hoc test revealed that all measures in PD patients were significantly smaller than in healthy elderly and healthy young subjects (p<0.02). All measures were significantly correlated with UPDRS scores(r=-0.689~-0.825). These results suggest that the developed system can be used as quantitative measures of the lower limb bradykinesia in PD patients.

Prediction of Withdrawal Resistance of Single Screw on Korean Wood Products

  • AHN, Kyung-Sun;PANG, Sung-Jun;OH, Jung-Kwon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.49 no.1
    • /
    • pp.93-102
    • /
    • 2021
  • In this article, withdrawal resistances of axially loaded self-tapping screws on wood products made by Korean Larch were predicted with existing estimation equation, and compared with experimental test data. The research was required because no design methodology for the withdrawal resistance of self-tapping screw is present in Korean building code (KBC). First, the withdrawal resistance of wood screw was predicted to use the withdrawal design value estimation equation in National Design Specification for Wood Construction (NDS). Second, three types of wood products, solid wood, cross-laminated timber (CLT) and plywood, were utilized for withdrawal test. For decades, various engineered wood products have been developed, especially cross-laminated timber (CLT) and hybrid timber composites such as timber composites of solid wood and plywood. Therefore, CLT and plywood were also investigated in this study as well as solid wood. Finally, the predicted values were compared with experimentally tested values. As the results, the tested values of solid wood and CLT were higher than the predicted values. In contrast, it is inaccurate to predict withdrawal resistance of plywood since prediction was higher than tested values.

Immediate Effects of Ankle Eversion Taping on Balance and Gait Function in Patients with Chronic Stroke: A Randomized Controlled Trial

  • Hye-In Bae;Myeong-Ho Lee;Myoung-Kwon Kim
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.18 no.2
    • /
    • pp.1-11
    • /
    • 2023
  • PURPOSE: This study examined the immediate effects of applying ankle eversion taping using kinesiology tape in chronic stroke patients-design: a randomized cross-over trial. METHODS: Seventeen stroke patients underwent three interventions in random order. The subjects were initially assigned randomly to an ankle eversion taping, placebo taping, or no taping for each intervention. Ankle eversion taping was used for mechanical correction and was involved in ankle dorsiflexion and eversion. The tape was stretched by 30-40%. Placebo tapping was applied in the same form as eversion tapping but was not stretched. The balance ability was assessed using the Y-balance test. The gait ability was assessed by maximum foot pressure and time of stance phase, and gait speed was assessed using a 10 m walk test (10MWT). All measurements were performed immediately after the intervention. RESULTS: The results showed that the dynamic balance and stance phase time in chronic stroke patients was improved after ankle eversion taping. The ankle eversion taping conditions increased significantly (p < .05) compared to the placebo and no taping conditions. CONCLUSION: The application of ankle eversion taping that uses kinesiology tape instantly increased the gait ability of chronic stroke patients. On the other hand, more research will be needed to identify the long-term effects of ankle eversion taping.

A Study on the Safety Evaluation Technique of Sluice Culvert (하천제방 배수통문 정밀 안전진단기법 연구)

  • Yoon, Jong-Ryeol;Kim, Jin-Man;Choi, Bong-Hyuck
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.41-46
    • /
    • 2008
  • After choosing twenty sluice culverts located at national rivers by detailed appearance evaluation, hydraulic response test and acoustic televiewer in addition to surface geophysical explorations were carried out to investigate the cavities which exist at the boundary of sluice culvert and ground. Tapping, GPR, 3-D resistivity surveys and acoustic televiewer imagery obtained successful results in limited conditions according to characteristics of the sites. On the other hand, hydraulic response test successfully detected cavity existing at the lower part of sluice culvert and its continuity. However, hydraulic response test can not supply the quantitative informations on the scale and the shape of cavity. Thus it is very important for accurate investigation to make comprehensive interpretation after supplying various surveys proper to site characteristics.

  • PDF

Survey of Risk Evaluation in the Clinical Research for IRB Members and Researchers (임상시험심사위원회 위원과 연구자를 대상으로 연구의 위험평가 설문조사)

  • Choi, Yong-Sung;Lee, Sun Ju;Yim, Hyeon Woo;Choe, Byung-in;Lee, Jae Won;Oh, Sang-cheul;Shin, Im Hee;Huh, Jung-Sik;Kwon, Ivo;Kim, Jin Seok;Yoo, Soyoung;Cho, Hyunin;Lee, Mi-Kyung;Shin, Hee-Young;Kim, Duck-An
    • The Journal of KAIRB
    • /
    • v.1 no.1
    • /
    • pp.5-21
    • /
    • 2019
  • Purpose: Institutional review board (IRB) classifies risks of clinical trials into less than minimal risk, minor increase over minimal risk, and more than minimal risk. Based on classification and evaluation for risk, IRB decides whether permitting consent exemption or asking additional protection for clinical research subject or not. The purpose of this study is to analyze how IRB members evaluate minimal risk by sending questionnaire survey with 12 predetermined scenarios. Methods: IRB members and researchers (pediatrician, gastroenterologist, neurologist, and neurosurgeon) in 11 different hospitals were asked to answer survey questions via email or online. We analyzed the differences of answers among several subgroups in each predetermined scenarios. Result: Responders were 212 personnel(110 researchers and 102 IRB members) from 11 centers. There were significant differences between IRB members and researchers in response such as blood sampling, skin prick test, one time catheterization in a girl, spinal tapping in child, non-enhance MRI in child, non-enhance MRI with chrolal hydrate in a child, spinal tapping without anesthesia in adult, bioequivalence test, gastric endoscopy, and non-enhance CT. significant differences between medical IRB members and non-medical members were also revealed in one time catheterization in a girl, spinal tapping in a child, non-enhance MRI in a child, bioequivalence test. Depending on researchers' department, they responded differently in several questionnaires as well. Conclusions: We have found that IRB members and researchers evaluate the risks differently. Researchers compared to IRB members, medical IRB members compared to non-medical members answered less than minimal risk in many cases. In assessing and evaluating the risks associated with the study, medical IRB members answered predetermined scenarios as less dangerous compared to non-medical IRB members. Difference among researchers where also revealed significantly. Researchers answered predetermined scenarios as less dangerous compare to other department researchers, especially in predetermined scenarios containing procedures they are familiar with.

  • PDF

Evaluation of Bearing Strength of Self-Tapping Screws according to the Grain Direction of Domestic Pinus densiflora

  • LEE, In-Hwan;KIM, Keonho;SHIM, Kug-bo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.50 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • To evaluate the bearing strength of red pine cross-laminated timber (CLT) with self-tapping screw (STS), which is widely used as a fastener for connection in CLT building, the bearing test was conducted. Accoring to the STS's diameters (8, 10, 12 mm), the bearing test specimens with half hole were manufactured. Bearing strength was compared and reviewed in consideration of the configuration in STS and the loading direction to the grain of red pine. As a result of the bearing test on the STS's diameter, the yield bearing load increases as the larger diameter of the STS in all directions of the red pine. The bearing strength of the thread part (thread + tip) was higher than the shank part (shank + shank cutter). In compared with the directions to the grain of red pine, the bearing strength of the cross section parallel to the loading direction was the highest, and the tangent section was the lowest bearing strength. The average bearing strength of the loading direction in parallel to the grain was 23.43 MPa, which was about 45% higher than the average 16.16 MPa in perpendicular to the grain. The predicted bearing strength calculated by Eurocode (EN) and Korean Building Code (KBC)'s equation was lower than the experimental value. It is nessesary to propose the new equations of bearing strength reflected the configuration information of STS.

Stability measurements on the implants of mandibular molar area using OsstellTM (OsstellTM을 이용한 하악구치부 임플랜트의 안정성 측정)

  • Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.3
    • /
    • pp.205-211
    • /
    • 2001
  • The aim of this investigation was to evaluate successfully functioning implants stability in the partially edentulous mandibular molar sites by resonance frequency measurements. Resonance frequency measurement is more objective and clinically non-invasive method than any other methods had been used. In this study, $Osstell^{TM}$ (Integration Diagnostics, Sweden) was used. 15 patients ( 7 males, 8 females ) were received each 2 implants in their mandibular unilaterally partial edentulous molar sites. Total 30 implants were installed, 28 implants were $Br{\aa}nemark^{(R)}$ self-tapping fixtures(MK II, Nobel Biocare, Sweden) and 2 were $3i^{(R)}$(USA) self-tapping fixtures. Minimum of functional loading durations was 12 months and there were no significant marginal bone resorptions and peri-implant problems. From this test, the following results were drawn: 1. Mean ISQ values of implants in the first and second mandibular molar area were $73.66{\pm}4.45$, $71.93{\pm}3.41$, respectively. There was no significant difference between two groups(p>0.05). Also mean ISQ value of total sum was 72.8. 2. Mean ISQ values of implants in males and females group were $71.64{\pm}4.06$, $73.81{\pm}3.76$, respectively. And there was no significant difference between two group(p>0.05). 3. Correlation between implant lengths and ISQ values was weak(r=0.128).

  • PDF

Development of Split Tees for Gas Steel Pipelines (강재 가스배관용 분기티의 개발 연구)

  • Kim Young Gyu;Noh Ou Sun;Kim Ji Yoon
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.4 s.12
    • /
    • pp.6-12
    • /
    • 2000
  • We have developed a new split tee which can be used to effectively branch into a main gas steel pipelines without losing any gas pressure or having to shut down a line. The split tee has been designed considering the locations of branch connection to the pipelines. Therefore, we could keep the depth of buried pipelines which used to be the problem of the conventional split tees. Test results of the developed split tee showed that the performance of the tightness, hydraulic strength, sealing, welding, bending, and compatibility were excellent. The application of the split tee can provide the advantage of eliminating cost and time, and easy field pipeline coatings.

  • PDF