• 제목/요약/키워드: Tapping test

검색결과 77건 처리시간 0.026초

태핑시험과 웨이블릿 변환을 이용한 복합적층판의 층간분리 검출 (Delamination detection in composite laminates using tapping test and wavelet transform)

  • 김성준;황인희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.214-215
    • /
    • 2013
  • The tapping test has simplicity of procedure for detection of the damage in aircraft structure. However, the result of tapping test depends on the subjective experience of inspector. In this paper, more objective tapping test has proposed. The impact force histories and tapping sounds are used as reference data to evaluate the delamination. The WT(wavelet transform) is used to decompose the test data. From the results, we could know that high frequency components of force and sound are reduced due to delamination in composite laminate. On these results, the tapping force and sound caused by tapping could be used for the reference data to evaluate the delamination in composite structure.

  • PDF

AE센서를 이용한 고속 탭핑용 공구 모니터링에 관한 연구 (A Study on Tool Monitoring for High Speed Tapping using AE Signal)

  • 김용규;이돈진;김선호;안중환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.315-318
    • /
    • 1997
  • In terms of productivity, the speed of machining process has been increasing in most of engineering part. But the tapping process does not reach at enough level compared with other machining processes because of its complicate cutting mechanism. In the high speed tapping process, the one of important elements is tool monitoring system to prevent tool breakage. This paper describes tool monitoring system by acoustic emission(AE) in the tapping process. We used 2 types of AE sensors in this test. The one is commercial sensor which is used in other machining monitoring system like polishing and the other is a self-fabricated sensor for this test. In this test we purpose to find out the frequency of AE signal in tapping process and verify the possibility of applying AE sensor in in-process tapping monitoring system. Also grasp of characteristic of tapping process by AE signal is handled.

  • PDF

Analyzing the Effect of Management Strategies on Gum Talha Yield from Acacia Seyal, South Kordofan, Sudan

  • Mohammed, M.H.;Roehle, H.
    • Journal of Forest and Environmental Science
    • /
    • 제27권3호
    • /
    • pp.135-141
    • /
    • 2011
  • The present study was carried out from September 2007 to February 2008 in Umfakarin natural forest reserve, South Kordofan, Sudan. The objective was to analyze the effect of different management strategies on yield of gum talha from Acacia seyal. A total of 493 single target trees were selected, based on their diameters, and assigned to tapping treatments in three different stand densities (making a total of nine treatments per stand density). The treatments are as follows: tapping date with three levels (first of October, 15 October and first of November) and two levels of local tapping tools (sonki, and makmak). Untapped trees were used as control. The first picking of gum was started fifteen days after tapping while the subsequent pickings were done in intervals of fifteen days. Yield per tree throughout the season was obtained by summing up the gum yield from all pickings. Yield throughout the season (from first to the last picking) were analyzed. General linear model (GLM) was used to test the effect of different tapping treatments on the yield of gum talha. Post hoc test after analysis of variance (ANOVA) based on Scheffe test was performed to examine the differences in gum yield as a result of different management strategies. The results showed that tapping has a significant influence on gum yield. Analysis of pick-to-pick yield indicated that only three treatments in dense stand density showed a decreasing pattern while the rest of treatments either have constant or unclear patterns. The results of the present study were based on a single season data and that may underscore the real effect of Acacia seyal stands' management strategies on gum talha yield. Conducting gum yield experiments in permanent trial plots are highly recommended in order to analyze gum yield of seasonal time series.

Comparative Biomechanical Study of Self-tapping and Non Self-tapping Tapered Dental Implants in Artificially Simulated Quality 2 Bone

  • Baek, Yeon-Wha;Kim, Duck-Rae;Park, Ju-Hee;Lim, Young-Jun
    • Journal of Korean Dental Science
    • /
    • 제4권2호
    • /
    • pp.52-58
    • /
    • 2011
  • Purpose: Modifications of implant design have been related to improving initial stability. The purpose of this study was to investigate their respective effect on initial stability between two tapered implant systems (self-tapping vs. non-self-tapping) in medium density bone using three different analytic methods. Materials and Methods: Self-tapping implant (GS III$^{(R)}$; Osstem Implant Co., Busan, Korea) and non-self-tapping implant (Replace Select$^{(R)}$; Nobel Biocare, G$\H{o}$teborg, Sweden) were investigated. In Solid rigid polyurethane blocks of artificially simulated Quality 2 bone, each of the 5 implants was inserted according to the manufacturer's instructions for medium-bone drilling protocol. Evaluation of initial stability was carried out by recording the maximum insertion torque (IT) and performing the resonance frequency analysis (RFA), and the pull-out test. Results: The IT and RFA values of self-tapping implant were significantly higher than those of non self-tapping implant (P=.009 and P=.047, respectively). In the pull-out values, no significant differences were found in implants between two groups (P=.117). Within each implant system, no statistically significant correlation was found among three different outcome variables. Conclusions: These findings suggest that design characteristics of implant geometry significantly influence the initial stability in medium bone density.

Effect of Transcranial Direct Current Stimulation on Movement Variability in Repetitive - Simple Tapping Task

  • Kwon, Yong Hyun;Cho, Jeong Sun
    • The Journal of Korean Physical Therapy
    • /
    • 제27권1호
    • /
    • pp.38-42
    • /
    • 2015
  • Purpose: Accuracy and variability of movement in daily life require synchronization of muscular activities through a specific chronological order of motor performance, which is controlled by higher neural substrates and/or lower motor centers. We attempted to investigate whether transcranial direct current stimulation (tDCS) over primary sensorimotor areas (SM1) could influence movement variability in healthy subjects, using a tapping task. Methods: Twenty six right-handed healthy subjects with no neurological or psychiatric disorders participated in this study. They were randomly and equally assigned to the real tDCS group or sham control group. Direct current with intensity of 1 mA was delivered over their right SM1 for 15 minutes. For estimation of movement variability before and after tDCS, tapping task was measured, and variability was calculated as standard deviation of the inter-tap interval (SD-ITI). Results: At the baseline test, there was no significant difference in SD-ITI between the two groups. In two-way ANOVA with repeated measurement no significant differences were found in a large main effect of group and interaction effect between two main factors (i.e., group factor and time factor (pre-post test)). However, significant findings were observed in a large main effect of the pre-post test. Conclusion: Our findings showed that the anodal tDCS over SM1 for 15 minutes with intensity of 1 mA could enhance consistency of motor execution in a repetitive-simple tapping task. We suggest that tDCS has potential as an adjuvant brain facilitator for improving rhythm and consistency of movement in healthy individuals.

손상이 있는 복합적층판의 충격거동 해석 (Impact Behavior Analysis on Composite Laminate with Damages)

  • 김성준;홍창호
    • 한국항공우주학회지
    • /
    • 제38권1호
    • /
    • pp.22-28
    • /
    • 2010
  • 복합재 구조물의 손상을 탐지하기위해 비파괴 검사법이 폭넓게 사용되고 있다. 태핑시험은 복합적층판의 손상을 탐지하는데 가장 일반적으로 사용하는 방법이다. 이 방법은 가벼운 해머 같은 장치를 이용하여 검사부위를 두드리고, 국부적인 강성변화를 이용하여 구조물의 손상을 평가한다. 진동신호의 변화는 동적인 접촉하중을 측정하여 탐지할 수 있다. 본 연구에서는 구조물에 층간분리나 표면균열 등의 손상이 존재하는 경우 태핑 시 충격하중이력의 특성이 변하는 것을 보였다. 그리고 손상의 영향을 검토하기위해 균열이 있는 복합재 로터블레이드에 대한 충격해석을 수행하였다.

태핑음을 이용한 복합적층판의 손상검출 (Damage Detection in Composite Laminates using Tapping Sound)

  • 김성준;홍창호
    • 한국항공우주학회지
    • /
    • 제37권11호
    • /
    • pp.1089-1095
    • /
    • 2009
  • 태핑 테스트 시 방사되는 음압을 Rayleigh 적분식을 이용하여 해석하였다. 구조물에 의해 방사되는 음은 구조물의 거동과 직접적으로 연관되므로 충격응답해석이 수행되어야 한다. 본 논문에서는 층간분리가 존재하는 적층판의 해석을 위하여 층간분리 모델을 사용하였으며, 해머 형상의 충격체를 모사할 수 있는 효과적인 스프링-질량모델을 제시하였다. 예측된 음압이력과 시험결과와 비교하였으며, 음압이력과 충격하중이력에 손상이 주는 영향을 검토하였다. 방사되는 음압과 충격하중이력은 적층판에 존재하는 손상에 영향을 주는 것을 보였다. 결과적으로 제안된 음을 이용한 태핑실험은 복합재에 존재하는 손상을 검출하는데 신뢰성 있는 방법임을 알 수 있었다.

Cerebrospinal Fluid Lumbar Tapping Utilization for Suspected Ventriculoperitoneal Shunt Under-Drainage Malfunctions

  • Lee, Jong-Beom;Ahn, Ho-Young;Lee, Hong-Jae;Yang, Ji-Ho;Yi, Jin-Seok;Lee, Il-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권1호
    • /
    • pp.1-7
    • /
    • 2017
  • Objective : The diagnosis of shunt malfunction can be challenging since neuroimaging results are not always correlated with clinical outcomes. The purpose of this study was to evaluate the efficacy of a simple, minimally invasive cerebrospinal fluid (CSF) lumbar tapping test that predicts shunt under-drainage in hydrocephalus patients. Methods : We retrospectively reviewed the clinical and radiological features of 48 patients who underwent routine CSF lumbar tapping after ventriculoperitoneal shunt (VPS) operation using a programmable shunting device. We compared shunt valve opening pressure and CSF lumbar tapping pressure to check under-drainage. Results : The mean pressure difference between valve opening pressure and CSF lumbar tapping pressure of all patients were $2.21{\pm}24.57mmH_2O$. The frequency of CSF lumbar tapping was $2.06{\pm}1.26times$. Eighty five times lumbar tapping of 41 patients showed that their VPS function was normal which was consistent with clinical improvement and decreased ventricle size on computed tomography scan. The mean pressure difference in these patients was $-3.69{\pm}19.20mmH_2O$. The mean frequency of CSF lumbar tapping was $2.07{\pm}1.25times$. Fourteen cases of 10 patients revealed suspected VPS malfunction which were consistent with radiological results and clinical symptoms, defined as changes in ventricle size and no clinical improvement. The mean pressure difference was $38.07{\pm}23.58mmH_2O$. The mean frequency of CSF lumbar tapping was $1.44{\pm}1.01times$. Pressure difference greater than $35mmH_2O$ was shown in 2.35% of the normal VPS function group (2 of 85) whereas it was shown in 64.29% of the suspected VPS malfunction group (9 of 14). The difference was statistically significant (p=0.000001). Among 10 patients with under-drainage, 5 patients underwent shunt revision. The causes of the shunt malfunction included 3 cases of proximal occlusion and 2 cases of distal obstruction and valve malfunction. Conclusion : Under-drainage of CSF should be suspected if CSF lumbar tapping pressure is $35mmH_2O$ higher than the valve opening pressure and shunt malfunction evaluation or adjustment of the valve opening pressure should be made.

한국형 신경행동검사 배터리의 개발 -면접과 컴퓨터 신경행동검사의 타당성 평가- (Development of Korean Neurobehavioral Test Battery -Assessment of the Validity of Traditional and Computerized Neurobehavioral Tests-)

  • 정종학;김창윤;사공준;전만중;박홍진
    • Journal of Preventive Medicine and Public Health
    • /
    • 제31권4호
    • /
    • pp.692-707
    • /
    • 1998
  • 우리나라 근로자의 특성과 산업보건 현실에 적합한 신경행동검사들을 선택하기 위하여 지금까지 국내의 일부 연구에서 사용되었던 신경행동검사들의 타당도를 비교평가하였다. 대구지역의 중소규모 사업장에서 톨루엔, 크실렌, 메틸에틸케톤, 이소프로필알콜, 메탄올에 폭로되는 유기용제 폭로군 96명과 대조군 100명을 대상으로 인구학적 변수와 직업관련 변수를 조사하고, 컴퓨터 신경행동검사 네 가지 검사항목(숫자 더하기, 부호숫자 짝짓기, 숫자 외우기, 손가락 두드리기)과 면접식 신경행동검사 일곱 가지 검사항목(Benton visual retention 검사, 숫자 외우기, 숫자부호 짝짓기, 숫자 더하기, 목적점찍기, 핀꼽기, 막대 두드리기)을 수행하였다. 11개의 신경행동검사 항목들 중 지각과 반응속도 영역에서 컴퓨터 부호숫자 짝짓기, 운동영역에서 컴퓨터 손가락 두드리기 및 미세운동영역에서 핀꼽기의 유사영역의 다른 검사에 비해 타당도가 상대적으로 높은 것으로 평가되었다. 이러한 결과는 산업장 근로자의 중추신경계장애의 선별을 위한 신경행동검사의 선택에 도움이 될 것으로 생각되나 대상자의 폭로기간이 길지 않고 폭로력과 재현성을 고려하지 못한 제한점을 가진다.

  • PDF

Push out tests on various shear connectors used for cold-formed steel composite beam

  • Rajendran, Senthilkumar;Perumalsamya, Jayabalan;Mohanraj, Divya
    • Steel and Composite Structures
    • /
    • 제42권3호
    • /
    • pp.315-323
    • /
    • 2022
  • Shear connectors are key elements that ensure integrity in a composite system. The primary purpose of a shear connector is to bring a high degree of interaction between composite elements. A wide variety of connectors are available for hot-rolled composite construction, connected to the beam through welding. However, with cold-formed members being very thin, welding of shear connectors is not desirable in cold-formed composite constructions. Shear connectors for cold-formed elements are limited in studies as well as in the market. Hence in this study, three different types of shear connectors, namely, single-channel, double channel, and self-tapping screw, were considered, and their performance assessed by the Push-out test as per Eurocode 4. The connection between channel shear connectors and the beam was made using self-tapping screws to avoid welding. The performance of the connectors was analyzed based on their ultimate capacity, characteristic capacity, ductility, and slippage during loading. Strength to weight ratio was also carried out to understand the proposed connectors' suitability for conventional ones. The results showed relatively higher initial stiffness and ductility for double channel connectors than other connectors. Also, self-tapping screws had a higher strength to weight ratio with low ductility.