• Title/Summary/Keyword: Tapping

Search Result 353, Processing Time 0.027 seconds

An investigation of worn DLC coatings using atomic force microscopy (DLC 코팅 마모면에 대한 원자력 현미경을 이용한 고찰)

  • ;;S.A.Chizhik
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.299-304
    • /
    • 2001
  • Tribofilms formed on worn surface protect the DLC coating surface and decrease the friction coefficient. However it is very difficult to evaluate their micromechanical properties due to their small thickness, inhomogeneity and discontinuity. The phase contrast images in tapping mode atomic force microscopy allow an estimation of inhomogeneity in micromechanical properties of the sample surface. The purpose of this investigation is to demonstrate how the phase contrast images contribute to the characterization of thin tribofilms.

  • PDF

fMRI of Visual and Motor Stimuli : Difference of Total Activation Depends on Stimulation Paradigm (시각과 운동의 뇌기능영상 : 자극에 따른 총활성화의 차이)

  • 정순철;송인찬;장기현;유병기;문치웅;조장희
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.1
    • /
    • pp.41-46
    • /
    • 1999
  • Purpose : To investigate the difference of total activation in visual area, motor area, and cerebellum according to the stimulation paradigm. Materials and Methods : Functional MR imaging was performed in 5 healthy volunteers with visual and motor activity using EPI technique. LED and Checker-Board stimulation were performed for visual activity. Thumb motion and Finger Tapping were performed for motor and cerebellum activity. Stimulus timing was 60sec. off, 120sec. on, 60sec. off. Data processing was carried out by using the cross-correlation method for each pixel. Each pixel was then selected and assumed activated if the correlation coefficient was equal or larger than a threshold value. Time course data was obtained by calculating the total activation which was defined as the number of activated pixel x averaged pixel intensity. Results : In the case of visual activity with LED stimulation, we found increased total activity of more than 100% compared with Checker-Board stimulation. In the case of motor area and cerebellum with Finger tapping stimulation, we found increased total activity of more than 10% and 150%, respectively compared with Thumb motion stimulation.

  • PDF

A Study on the NC Embedding of Vision System for Tool Breakage Detection (공구파손감지용 비젼시스템의 NC실장에 관한 연구)

  • 이돈진;김선호;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.369-372
    • /
    • 2002
  • In this research, a vision system for detecting tool breakage which is hardly detected by such indirect in-process measurement method as acoustic emission, cutting torque and motor current was developed and embedded into a PC-NC system. The vision system consists of CMOS image sensors, a slit beam laser generator and an image grabber board. Slit beam laser was emitted on the tool surface to separate the tool geometry well from the various obstacles surrounding the tool. An image of tool is captured through two steps of signal processing, that is, median filtering and thresholding and then the tool is estimated normal or broken by use of change of the centroid of the captured image. An air curtain made by the jetting high-pressure air in front of the lens was devised to prevent the vision system from being contaminated by scattered coolant, cutting chips in cutting process. To embed the vision system to a Siemens PC-NC controller 840D NC, an HMI(Human Machine Interface) program was developed under the Windows 95 operating system of MMC103. The developed HMI is placed in a sub window of the main window of 840D and this program can be activated or deactivated either by a soft key on the operating panel or M codes in the NC part program. As the tool breakage is detected, the HMI program emit a command for automatic tool change or send alarm to the NC kernel. Evaluation test in a high speed tapping center showed the developed system was successful in detection of the small-radius tool breakage.

  • PDF

Characteristics of Sap Exudation from Acer okamotoanum (Nakai) Plantation Forest in Jinju Region (진주지역 우산고로쇠나무 인공림의 수액 출수 특성)

  • Kim, Chang-Hwan;Park, Joon-hyung;Lee, Kwang-Soo;Park, Yong-Bae;Lee, Kyoung-Tae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.3
    • /
    • pp.308-316
    • /
    • 2017
  • This study was carried out to investigate the sap exudation characteristics in Acer okamotoanum (Nakai) plantation forest. As a result, Sap exudation quantity was rapidly reduced when mean temperature was increased by above $3.4^{\circ}C$. Considering this result, sap collection before end of February is more effective. Sap exudation quantity during the day started at approximately 9 o' clock, and reached the peak at approximately 11 o' clock, and ended at approximately 16 o' clock. Sugar content of sap was reduced with increasing period. Except for Na, and mineral components by tapping period were no significant difference.

Nondestructive Inspection of Launch Vehicle Structural Components (우주 발사체 구조 요소의 비파피검사)

  • Kong, Cheol-Won;Youn, Jong-Hoon;Park, Jae-Sung;Eun, Se-Won;Jang, Young-Soon;Yi, Yeong-Moo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.331-337
    • /
    • 2009
  • Space launch vehicles require highly reliable, lightweight structures. It is thus important to monitor the structural health of these components with nondestructive inspections. In this paper, we studied an example of a nondestructive inspection that was partially applied to the manufacture and inspection of a launch vehicle. Ultrasonic tests, X-rays, tapping, and acoustic emissions comprised the inspection method. A payload fairing, high pressure tank, fastener part, and bonding part were used as hardware to be inspected. We proposed a quantitative standard for debonding inspection of the payload fairing and acoustic emission data for the proof test of the high pressure tank. We analyzed the fracture mode of the sandwich fastener part according to frequency changes. We also proposed a standard specimen for ultrasonic inspection of bonds of different materials. The present analyses and results provide data for evaluation of the launch operation sequence to ensure launch vehicles afford high reliability.

Compact 40 GHz Hairpin Band-Pass Filter (초소형 40 GHz Hairpin 대역통과 여파기)

  • Lee, Young Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.1
    • /
    • pp.27-30
    • /
    • 2018
  • In this study, a 40 GHz band pass filter(BPF) employing a hair-pin structure has been designed, fabricated, and characterized for millimeter-wave wireless communication applications. Using the 3 dimensional(3-D) electromagnetic(EM) tool and design equations of the hairpin BPF, the BPF was desgned on the 5 mil-thick Duroid substrate(RT5880) with a relative dielectric constant (${\varepsilon}_r$) of 2.2. The tapping point (t) of the U-shape resonator in the input and output port has been determined using extracted an external Q-factor ($Q_e$). The coupling coefficients between the other resonators are calculated by adjusting the physical dimensions for the desired response of the BPF. The fabricated BPF was characterized using probing method on a probe station. Its measured center frequency(fc) and fractional BW are 41.6 GHz and 7.43 %, respectively. The measured return loss is below -10 dB at the pass band and the insertion loss is 3.87 dB. The fabricated BPF is as small as $9.1{\times}2.8mm^2$.

Effect of Body Posture on the Rest Position and the Rotational Torque Movement of the Mandible (신체 자세의 변화가 하악의 안정위와 비틀림 회전운동에 미치는 영향)

  • Jung, Seung-Ah;Han, Kyung-Soo;Park, Mi-Sung;Yang, Keun-Young
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.4
    • /
    • pp.383-394
    • /
    • 2000
  • This study was performed to investigate the effect of change of body posture on the rest position and the rotational torque movement of the mandible. Thirty dental students without any signs and symptoms of temporomandibular disorders and with natural dentition were selected for this study. Cervical inclination and the amount of the mandibular movement on protrusion, on left and right excursion, and on tapping in three body postures such as sitting position, supine position without pillow, and supine position with pillow were measured by goniometer, Cervical-Range-of-$Motion^{(R)}$, and mandibular tracking device, $BioEGN^{(R)}$ with $Rotate!^{(R)}$ program. The data obtained were classified and processed according to body posture and type of lateral guidance with SPSS windows program and the results were as follows: 1. There was significant difference among the three cervical inclinations by body postures. 2. Comparison of mandibular rest positions among body postures showed significant difference only for lateral distance in frontal plane, but comparison between before and after swallowing showed significant difference except for the lateral distance, vice versa. 3. Distance and amount of the rotational torque movement on protrusion and/or lateral excursions didn't show any difference by body posture. But by both body posture and lateral guidance type, there were slightly significant difference for some items. 4. A significant difference was shown for the rotational torque movement in frontal plane on tapping by body postures, for the lateral distance in frontal plane on sitting position by lateral guidance type, and for the rotational torque movement in frontal plane by both body posture and lateral guidance type.

  • PDF

Android Smart Phone App for early diagnosis of Parkinson's Disease (파킨슨병 조기 진단을 위한 안드로이드 기반의 앱 개발)

  • Moon, Ho-Sang;Noh, Seung-Jae;Chung, Sung-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.145-152
    • /
    • 2019
  • Parkinson's disease(PD) is one of the three major senile diseases and the incidence rate is increasing worldwide as the population ages. And as the disease progresses, time and economic costs increase, so it is important to understand the progress of the disease and to diagnose it early In this paper, we propose a method for pre-screening Parkinson's disease using a smartphone. The contents of the developed application are composed of tapping, tremor, spiral drawing, and gait based on Part III of the Unified Parkinson's Disease Rating Scale. This can be used to quantitatively diagnose Bradykinesia, Tremor and Postural Instability, which are known as motility symptoms of Parkinson's disease, and to monitor the progress of symptoms. This method is expected to be useful for the diagnosis and treatment of Parkinson's disease.

The Feasibility of Event-Related Functional Magnetic Resonance Imaging of Power Hand Grip Task for Studying the Motor System in Normal Volunteers; Comparison with Finger Tapping Task

  • Song, In-Chan;Chang, Kee-Hyun;Han, Moon-Hee
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.111-111
    • /
    • 2001
  • 목적: To evaluate the feasibility of the event-related functional MR study using power grip studying the hand motor system 대상 및 방법: Event-related functional MRI was performed on a 1.5T MR unit in seven norm volunteers (man=7, right-handedness=2, left-handedness=5, mean age: 25 years). A single-shot GRE-EPI sequence (TR/TE/flip angle: 1000ms/40ms/90, FOV = 240 mm matrix= 64$\times$64, slice thickness/gap = 5mm/0mm, 7 true axial slices) was used for functiona MR images. A flow-sensitive conventional gradient echo sequence (TR/TE/flip angl 50ms/4ms/60) was used for high-resolution anatomical images. To minimize the gross hea motion, neck-holders (MJ-200, USA) were used. A series of MR images were obtained in axial planes covering motor areas. To exclude motion-corrupted images, all MR images wer surveyed in a movie procedure and evaluated using the estimation of center of mass of ima signal intensities. Power grip task consisted of the powerful grip of all right fingers and hand movement ta used very fast right finger tapping at a speed of 3 per 1 second. All tasks were visual-guid by LCD projector (SHARP, Japan). Two tasks consisted of 134 phases including 7 activatio and 8 rest periods. Active stimulations were performed during 2 seconds and rest period were 15 seconds and total scan time per one task was 2 min 14 sec. Statistical maps we obtained using cross-correlation method. Reference vector was time-shifted by 4 seconds an Gaussian convolution with a FWHM of 4 seconds was applied to it. The threshold in p val for the activation sites was set to be 0.001. All mapping procedures were peformed usin homemade program an IDL (Research Systems Inc., USA) platform. We evaluated the activation patterns of the motor system of power grip compared to hand movement in t event-related functional MRI.

  • PDF

A Study on the Electrical Discharge Machining Tap by using Cu Electrodes of the Cold-Work Tool Steel (냉간 금형용 공구강의 Cu 전극을 이용한 방전 탭에 관한 연구)

  • Lee, Eun-Ju;Park, In-Soo;Kim, Hu-Kwon;Wang, Duck-Hyun;Chung, Han-Shik;Lee, Kwang-Sung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.5
    • /
    • pp.131-136
    • /
    • 2016
  • Currently, an EDM tapping procedure has comprised some parts of the engraving discharge process for the press die. Usually, tapping has been used in cases where we are unable to mechanically machine using steelwork processes due to an increase in the hardness of a material after heat treatment in relation to a design change or missing process. Here, we analyze the influence of discharge tap shape on discharge time, discharge current, and the number of repetition conditions when a cold-work tool steel (STD11) has been treated with a discharge tapped by a screw-shaped cu electrode. The most important influence on processing condition has been determined to be the number of discharge repetitions. As this number increases, the angle reduction of a thread closes to an angle of the electrode via a power generation reduction. The optimal combination of conditions has been determined to be three discharge repetitions, $180{\mu}s$ of discharge time (same as existing regulations), and 25.4A of peak current. A 0.2749db advantage has emerged after comparing between this combination of optimal conditions and the SN rate of existing regulations.