• Title/Summary/Keyword: Tapered type miniscrew

Search Result 2, Processing Time 0.018 seconds

REMOVAL TORQUE AND BONE FORMATION OF ORTHODONTIC MINISCREW IMPLANT (교정용 미니스크류 임플랜트의 제거회전력 및 골형성에 관한 연굴)

  • Yun, Young-Kuk;Ryu, Jae-Jun;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.492-505
    • /
    • 2007
  • Statement of problem: An orthodontic miniscrew implant has been used as a skeletal anchorage for orthodontic treatment. However, any relation among the influence of the cortical bone, morphologic differences of orthodontic miniscrew implants and new bone formation hasn't been made clear yet. Purpose: The purpose of this study was to evaluate whether the orthodontic miniscrew implant could work as an intraoral skeletal anchorage immediately and stably for orthodontic treatment after insertion of it. Material and methods: Two types of orthodontic miniscrew implants were used in this experiment; tapered type and straight type. One hundred and sixty eight orthodontic miniscrew implants were inserted into the tibiae of 21 rabbits and sacrificed on 3, 7, 11, 14, 21 and 28days later after insertion of them to study removal torque values and histologic and histomorphometric analyses. Results: The results were as follows. 1. The removal torque values of the tapered type were higher than those of the straight type in all groups(p<0.05). 2. There wasn't any distinguishing differences between the tapered type and the straight type about the new bone formation percentage. 3. The removal torque values for both the tapered type and the straight type were gradually decreased at early stages of the test but started to increase at the 7 days group of the straight type and the 11 days group of the tapered type. 4. New bone formation percentage was increased gradually for both the tapered and the straight types as time passed(p<0.05). 5. It was found that the tapered type showed lower values in the cortical bone about both the maximum equilibratory stress distribution and the maximum principal stress distribution than the straight type in linear finite elements analysis. Conclusion: According to the research, the removal torque values were decreased at 7 days group of the tapered type and 11 days group of the straight type after the insertion of the orthodontic miniscrew implants in tibiae of rabbits. Considering the human bone activity, it is better to apply the orthodontic force $3{\sim}4$ weeks later than to apply it immediately after the insertion of orthodontic miniscrew implants. Considering that general orthodontic force is about $250{\sim}500$ grams, the tapered type can be worked as a stable skeletal anchor age in an orthodontic treatment even if the orthodontic force is applied on it immediately after the insertion of it.

Comparison of insertion torque regarding changes in shape, diameter, and length of orthodontic miniscrews (교정용 미니스크류의 형상에 따른 식립 토오크의 비교)

  • Lim, Seon-A;Cha, Jung-Yul;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.37 no.2 s.121
    • /
    • pp.89-97
    • /
    • 2007
  • Objective: The purpose of this study was to measure the insertion torque of orthodontic miniscrews regarding changes in their shape, diameter, and length. Methods: Torque values were measured during continuous insertion of the miniscrews into solid rigid polyurethane foam, using a torque tester of driving motor type with a regular speed of 3 rpm. Orthodontic miniscrews (Biomaterials Korea, Seoul, Korea) of cylindrical type and taper type were used. Results: Increasing the length and diameter of the miniscrews increased the maximum insertion torque value in both cylindrical and taper type screws. Insertion torque was increased at the incomplete head of the cylindrical type screw, and at the tapered part of the taper type screw. The insertion torque value of miniscrews was influenced most by diameter, then shape and length. As a result, it was shown that the diameter of the screw had the most influence on insertion torque, and the taper type screw had a higher torque value than the cylindrical type screw. Conclusion: Therefore, a large diameter or taper type screw are adequate for areas of thin cortical bone with a large interdental space, and a small diameter or cylindrical type screw are adequate in the mandibular molar area or the midpalatal area having thick cortical bone.