• Title/Summary/Keyword: Tapered Arch

Search Result 23, Processing Time 0.02 seconds

New virtual orthodontic treatment system for indirect bonding using the stereolithographic technique

  • Son, Kyoung-Hoi;Park, Jae-Woo;Lee, Dong-Keun;Kim, Ki-Dal;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.138-146
    • /
    • 2011
  • The purpose of this article is to introduce a new virtual orthodontic treatment (VOT) system, which can be used to construct three-dimensional (3D) virtual models, establish a 3D virtual setup, enable the placement of the virtual brackets at the predetermined position, and fabricate the transfer jig with a customized bracket base for indirect bonding (IDB) using the stereolithographic technique. A 26-year-old woman presented with anterior openbite, crowding in the upper and lower arches, and narrow and tapered upper arch, despite having an acceptable profile and balanced facial proportion. The treatment plan was rapid palatal expansion (RPE) without extraction. After 10 days of RPE, sufficient space was obtained for decrowding. After a 10-week retention period, accurate pretreatment plaster models were obtained using silicone rubber impression. IDB was performed according to the protocol of the VOT system. Crowding of the upper and lower arches was effectively resolved, and anterior openbite was corrected to normal overbite. Superimposition of the 3D virtual setup models (3D-VSM) and post-treatment 3D virtual models showed that the latter deviated only slightly from the former. Thus, the use of the VOT system helped obtain an acceptable outcome in this case of mild crowding treated without extraction. More cases should be treated using this system, and the pre- and post-treatment virtual models should be compared to obtain feedback regarding the procedure; this will support doctors and dental laboratory technicians during the learning curve.

Conceptual Design of the Three Unit Fixed Partial Denture with Glass Fiber Reinforced Hybrid Composites (Glass fiber 강화 복합레진을 사용한 3본 고정성 국소의치의 개념 설계 연구)

  • Na, Kyoung-Hee;Lee, Kyu-Bok;Jo, Kwang-Hun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.145-155
    • /
    • 2002
  • The results of the present feasibility study are summarized as follows, 1. The three unit bridge of knitted material and UD fibre reinforcement has both the rigidity and the strength against a vertical occlusal load of 75N. 2. Stress concentration at the junctional area between the bridge and the abutments, i.e. between the pontic and the knitted caps was observed. In the case of the bridge with reinforcement straps, it was partly shown that the concentration problem could be improved by simply increasing the fillet size at the area. Further refining in the surface of the junctional area will be needed to ensure a further improvement in the stress distribution. This will require some trade off in the level of the stress and the available space. A parametric study will help to decide the appropriate size of the fillet. 3. Design refinement is a must to improve the stress distribution and realize the most favourable shape in terms of fabrication. The current straight bar with a constant cross section area can be redesigned to a tapered shape. The curve from the dental arch should also be placed on the pontic design. In accordance with design refinement, the resistance of the bridge frame to other load cases should be evaluated. 4. Although not included in the present feasibility study, it is estimated that bridges of the anterior teeth can be made strong enough with the knitted material without further reinforcement using unidirectional materials. In this regard, a feasibility study on design concepts and stress analysis for 3, 4, 5 unit bridge is suggested. 5. Two types of bridge were analysed in terms of fatigue. The safe life design concept, i.e. fatigue design concept, looks reasonable for the bridge where if cracks should form and propagate there is virtually nothing a dentist to do. The bridge must be designed so that no crack will be initiated during the life span. In the case of crowns, however, if constructed with composite resin with knitted materials, it might be possible to repair them, which in general is impossible for crowns of PFM or of metal. Therefore for composite resin crowns, a damage tolerance design concept can be applied and reasonably higher operational stresses can be allowed. In this case, of course, a periodic inspection program should be established in parallel. 6. Parts of future works in terms of structural viewpoint which need to be addressed are summarized as the following: 1) To develop processing technology to accommodate design concepts; 2) More realistic modelling of the bridge and analysis-geometry and loading condition. Thickness variation in the knitted material, taper in the pontic, design for anterior tooth bridge, the effect of combined loads, etc, will need to be included; 3) To develop appropriate design concepts and design goals for the fibre composite FPD aiming at taking the best advantage of knitted materials, including the damage tolerance design concept; 4) To develop testing method and perform test such as static ultimate load test, fatigue test, repair test, etc, as necessary.

Nicardipine Hydrochloride Injectable Phase IV Clinical Trial-Study on the antihypertensive effect and safely of nicardipine for acute aortic dissection (급성대동맥해리에 대한 혈압강하요법으로서의 Nicardipine.HCI 주사액(Perdipine$^{circledR}$)의 유효성 및 안전성을 검토하기 위한 다기관 공동, 공개 제4상 임상시험)

  • Kim, Kyung-Hwan;Moon, In-Sung;Park, Jang-Sang;Koh, Yong-Bok;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.35 no.4
    • /
    • pp.267-273
    • /
    • 2002
  • Background: We performed a phase IV clinical trial to examine the usefulness of a continuous infusion of nicardipine hydrochloride to control hypertension in patients with acute aortic dissection. material and Method: Systolic/diastolic blood pressure, and heart rate were monitored before and after the intravenous administration of nicardipine in 31 patients with aortic diseases. The period of nicardipine administration in each patient was from 3 to 14 days. Efficacy was evaluated by determining the average amount of blood pressure reduction on the 3rd day of drug administration. The dosage of another antihypertensive agent was slowly tapered down, and ultimately replaced by the test drug. Result: 28 patients were diagnosed as acute aortic dissection, 2 patients as rupture of the aortic arch aneurysm, and 1 patient as traumatic aortic rupture. Mean age was 53.9 $\pm$ 14.9(29~89) years, and 21 patients(67.7%) were male. 14 patients(32.3%) had complications associated with underlying aortic disease: aortic insufficiency in 7, hemopericardium in 6, acute renal failure in 1, paraplegia in 1, lower extremity ischemia in 1, and hemothorax in 1. The time needed to reach the target blood pressure was within 15 minutes in 16, from 15 to 30 minutes in 10, from 30 to 45 minutes in 3 and from 45 to 60 minutes in 2, and their baseline average systolic, diastolic, and mean arterial blood pressures(mmHg) were 147$\pm$23, 82.3$\pm$ 18.6, and 104 $\pm$ 18, respectively. Average systolic, diastolic, and mean arterial blood pressures(mmHg) on the third day of nicardipine infusion were 119$\pm$ 12, 69$\pm$9, and 86$\pm$8, and they all showed statistically significant decrease(p<0.05). The average systolic, diastolic, and mean arterial blood pressure(mmHg) after the discontinuation of the nicardipine infusion were 119 $\pm$ 15, 71 $\pm$ 14, and 86$\pm$ 13, respectively. No significant difference was observed between the average pressures measured on the third day and those measured after the discontinuation of the nicardipine infusion, and no definite side effects were observed during the study period. Conclusion: Nicardipine hydrochloride was both effective and safe at controlling blood pressure in patients with acute aortic dissection.