• Title/Summary/Keyword: Tape measurement

Search Result 158, Processing Time 0.035 seconds

CPW-fed UWB Monopole Paper Antenna (CPW 급전 UWB 모노폴 종이 안테나)

  • Park, Dong-Kook
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.607-612
    • /
    • 2021
  • This paper presents a novel CPW-fed UWB monopole paper antenna made by paper and copper tape. Through the simulation, the optimized antenna design parameters were obtained, and an antenna having an omni-directional radiation pattern and a gain of 2.2 dBi or more in the UWB frequency band of 3.1-10.6 GHz was designed. The antenna was manufactured using general A4 paper and copper tape, and the measurement result satisfies the return loss of -10dB or less in the UWB frequency band and confirm that the return loss characteristic was maintained even when the antenna plane was bent by 3 mm in the longitudinal direction. The proposed antenna is a wearable device that can provide services in the UWB band, and can be manufactured inexpensively by printing it with a conductive print on paper. So it can be used as a wearable antenna for UWB communication in various application fields such as logistics and disposable terminals.

A Study on Changes to the Upper Body Shape of Elderly Japanese Women -Analysis of the Transverse Plane by Age Group-

  • Oh, Hee-Kyoung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.42 no.4
    • /
    • pp.726-736
    • /
    • 2018
  • This study determined how the upper body shape of elderly women changes with age in order to improve the fit of clothing worn by elderly women. Thirty-nine healthy elderly Japanese women had their body measurements taken by measuring tape and a 3D body line scanner (Hamamatsu Model #C9036-02) from December 2011 to March 2012 at a university in Tokyo. It was found that the shoulder line shortens in women between the ages of 70 and 74, but that the upper arm lengthens in women between the ages of 75 and 79. It was also found that the upper part of the scapular area rolls forward in women between the ages of 70 and 74, and that the point of the back which protrudes the most-the lower scapular area-rolls forward in women between the ages of 75 and 79. The results will be helpful for designing clothes for elderly women as their body shape changes with age.

A Novel Viscosity Measurement Technique Using a Falling Ball Viscometer with a High-speed Camera

  • Jo, Won-Jin;Pak, Bock-Choon;Lee, Dong-Hwan
    • KSTLE International Journal
    • /
    • v.8 no.1
    • /
    • pp.16-20
    • /
    • 2007
  • This study introduces a new approach to a falling ball viscometer by using a high speed motion camera to measure the viscosity of both Newtonian and non-Newtonian fluids from the velocity-time data. This method involves capturing continuous photographs of the entire falling motion of the ball as the ball accelerates from the rest to the terminal velocity state. The velocity of a falling ball was determined from the distance traversed by the ball by examining video tape frame by frame using the marked graduations on the surface of the cylinder. Each frame was pre-set at 0.01. Glycerin 74% was used for Newtonian solution, while aqueous solutions of Polyacrylamide and Carboxymethyl Cellulose were for non-Newtonian solutions. The experimental viscosity data were in good agreements with the results obtained from a rotating Brookfield viscometer.

Fabrication of Porous Ceramics and Multilayered Ceramics Containing Porous Layers; II. Heterogeneous Laminates (다공성 세라믹스와 다공질층을 포함하는 적층세라믹스의 제조에 관한 연구;II. 불균일 적층소결체)

  • 이해원;윤복규;송휴섭
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.11
    • /
    • pp.1323-1329
    • /
    • 1994
  • Tape casting and lamination were used to produce heterogeneous laminates with alternating layers of different porosity and homogeneous laminates with component layers of the same porosity. The pore structure was investigated for heterogeneous laminates, and bend strength was measured for comparison with that of homogeneous laminates. For a reference, strength measurement was made for the porous body fabricated by sintering samples dry-pressed at low pressure with spray-dried granules. Strength increase, in the range 50~120 MPa, was achieved in the presence of the surface dense layer, while extensive delamination, presumably responsible for enhanced fracture toughness, took place through the internal porous layer.

  • PDF

Developemet of noncontact velocity tracking algorithm for 3-dimensional high speed flows using digital image processing technique (디지털 화상처리를 이용한 유동장의 비접촉 3차원 고속류 계측법의 개발)

  • 도덕희
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.259-269
    • /
    • 1999
  • A new algorithm for measuring 3-D velocity components of high speed flows were developed using a digital image processing technique. The measuring system consists of three CCD cameras an optical instrument called AOM a digital image grabber and a host computer. The images of mov-ing particles arranged spatially on a rotation plate are taken by two or three CCD cameras and are recorderd onto the image grabber or a video tape recoder. The three-dimensionl velocity com-ponents of the particles are automatically obtained by the developed algorithm In order to verify the validity of this technique three-dimensional velocity data sets obtained from a computer simu-lation of a backward facing step flow were used as test data for the algorithm. an uncertainty analysis associated with the present algorithm is systematically evaluated, The present technique is proved to be used as a tookl for the measurement of unsteady three-dimensional fluid flows.

  • PDF

The Critical Current Measurement of HTS tapes According to Bending Diameter (굽힘 반경에 따른 HTS tape 임계전류 측정)

  • Joo, Jin-Hong;Kim, Hae-Joon;Kim, Seog-Whan;Song, Kyu-Jeong;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.903-905
    • /
    • 2003
  • High temperature superconductor (HTS) tapes are now commercially available for practical applications to apply various purposes. However HTS tapes show different electrical and mechanical characteristics, according to the manufacturers who are trying to apply various fabrication processes and treatments. From the viewpoint of an application it is very important to investigate the properties of HTS tapes under mechanical stress because the tapes will be wound with twisting and tension in applications such as magnets and cables. Thus, we studied characteristics of HTS tapes and measure critical current under bending, considering of a mechanical conditions. A description of some typical results will be presented with discussions.

  • PDF

Capturing Distance Parameters Using a Laser Sensor in a Stereoscopic 3D Camera Rig System

  • Chung, Wan-Young;Ilham, Julian;Kim, Jong-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.387-392
    • /
    • 2013
  • Camera rigs for shooting 3D video are classified as manual, motorized, or fully automatic. Even in an automatic camera rig, the process of Stereoscopic 3D (S3D) video capture is very complex and time-consuming. One of the key time-consuming operations is capturing the distance parameters, which are near distance, far distance, and convergence distance. Traditionally these distances are measured by tape measure or triangular indirect measurement methods. These two methods consume a long time for every scene in shot. In our study, a compact laser distance sensing system with long range distance sensitivity is developed. The system is small enough to be installed on top of a camera and the measuring accuracy is within 2% even at a range of 50 m. The shooting time of an automatic camera rig equipped with the laser distance sensing system can be reduced significantly to less than a minute.

The evaluation of thermal parameter for quench characteristics in Bi-2223/Ag superconducting system (Bi-2223/Ag 초전도시스템의 퀜치특성을 위한 열적 파라미터 평가)

  • Choi, S.;Nah, W.;Jang, S.H.;Joo, J.;Ha, H.S.;Sohn, M.H.;Kwon, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1237-1239
    • /
    • 2005
  • In this study, we estimate the thermal conductivity of stainless steel reinforced Bi-2223/Ag tape which was made from American Superconductor. The equipments for thermal conductivity measurement was set up using conduction cooled cryocooler. Two direction of thermal conductivity was measured. The one is the direction of cut length, and the other is direction of transverse of wounded coil with insulation material. It was observed that the thermal conductivity of transverse direction of coil was extremely lower than that of cut length direction. It was mainly seems that superconducting filaments and insulation material were effected on thermal conductivity in thermal conductivity of transverse direction.

  • PDF

The Application of Machine Vision to IC Surface Inspection

  • Chung, Yi-Chan;Tsai, Chih-Hung;Lin, Yu-Tang
    • International Journal of Quality Innovation
    • /
    • v.4 no.2
    • /
    • pp.50-64
    • /
    • 2003
  • During IC inspection, which includes the two parts of Mark and Lead, the deviation of IC on the tape occurring in high speed movements usually generates light reflection effect, which in turn causes errors in IC recognition as measured by machine vision system. This research filters the light reflection effect by developing standard components, identifies the correct position of IC Lead, hence fixes the measurement errors or non-measurability caused by light reflection, avoids the resulting discontinued operation of measuring system, and improves the productivity.

Current sharing measurement using non-contact method for parallel HTS tapes conductor according to tape array geometry (병렬도체에서 선재의 배열형상에 따른 비접촉식 전류분류 측정)

  • Byun, S.;Park, M.;Choi, S.;Park, S.;Lee, S.;Kim, W.;Lee, J.;Choi, K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.1
    • /
    • pp.32-36
    • /
    • 2008
  • An HTS conductor with parallel HTS tapes is essential for a large power HTS device to flow a large current. One of the most important factor for this conductor is a current distribution. Non-uniform current distribution in parallel tapes makes the critical current of the conductor low and the AC losses high. In this paper we proposed a non-contact method which measured each current in parallel tapes by using an array of Hall sensors. A matrix can be derived from this array for calibration. The current distributions of 4 and 6 parallel tapes were measured.