• Title/Summary/Keyword: Tape measurement

Search Result 158, Processing Time 0.03 seconds

Analysis of Intrarater and Interrater Reliability of Trunk Repositioning Error Test using a Portable Digital Inclinometer (디지털경사계를 사용한 체간재위치오류 검사의 신뢰도 분석)

  • Chang, Woo-Nam;Lee, Kyoung-Bo;Yeom, Jun-Woo;Hwang, Byong-Yong
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.4
    • /
    • pp.210-216
    • /
    • 2013
  • Purpose: A cost effective tool for the clinical measurement of trunk reposition sense is clearly needed. This study was to analyze intrarater and interrater Reliability of trunk repositioning error (TRE) test which assesses trunk position sense using a portable digital inclinometer. Methods: Twenty four normal healthy subjects were recruited. TRE was measured using a portable digital inclinometer. A digital inclinometer (Acumar-ACU360; Lafayetter Instrument) with precision to $1^{\circ}$ was placed on skin over the spinous process from first to second thoracic vertebra (T1-T2) and secured with double-sided tape. TRE test during sitting forward and lateral flexion movement was assessed. When they reached a point approximately 50% of full trunk flexion range, the examiner instructed the subjects to stop and told them. This was the target position that they should try to reproduce exactly. Each subject performed six trials. Results: ICC (2,1) for intrarater reliability (with-day and between-day) of TRE test in sagittal and frontal plane of movement was 0.75 and 0.78 (excellent reliability). Interrater reliability was 0.66 in sagittal and 0.64, frontal plane (fair to good reliability). However, there were poor correlations between an average of TRE test in sagittal and frontal plane. Conclusion: TRE test using a portable digital inclinometer demonstrated good to excellent reliability. The device may be a cost effective clinical measurement for trunk reposition sense measurement.

A Study of Tight-fit Bodice Pattern for 20's Women (20대 여성의 Tight-fit원형설계에 관한 연구)

  • 정복희;나미향
    • Journal of the Korean Home Economics Association
    • /
    • v.39 no.8
    • /
    • pp.137-154
    • /
    • 2001
  • This study was made to draft the tight fitting bodice pattern which horizontal and perpendicular stands are to be lightly set, with the consideration of characteristics of body shape in design of clothes. Measurement of body was conducted on 53 women in twenties, and observation was made on surface development pattern by adhesive tape addition method and gypsum method on three standard objects. In the study, bodice pattern was completed by using already made Somato- measurer, compared with existing bodice pattern, and the results are as follows. The result of the correlation analysis by body measurement shows that chest circumference has a relation to B$.$P-front neck point, side neck point, shoulder point, front interscye breadth point, and the item in spine scapulae point has relation to the item of back neck line, and front & back horizontal values. The degree of shoulder slant, width of armhole and of its depth, the amount of breast, back space, back length were shown to be directly measured from the body. In surface development pattern, tight-fit bodice pattern necessary to the breast volume and back space were shown to be investigated and these volume have to be given in setting up basic line for clothes design together with body measurement value. The result of sensory evaluation for appearance test on fitness shows higher value of research bodice including line of shoulder line, front and back interscye breadth, chest circumference, waist circumference, armhole circumference and of its depth, compared with the research bodice in most items. The result of this study is seen showing high effectiveness for the basic data to design the ready-made dress of high sensitivity of high value added tat.

  • PDF

Spinal Motor Neuron and Electroencephalogram Changes after Different Kinesio Taping Method Therapy in normal People (키네시오 테이핑 적용 방식이 정상인의 척수운동신경원 흥분성과 뇌파 변화에 미치는 영향)

  • Bae, Sea-Hyun;Kim, Gi-Do;Kim, Kyung-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.11
    • /
    • pp.791-799
    • /
    • 2013
  • This study to evaluate the spinal motor neuron and electroencephalogram effects of applying different kinesio taping method therapy in normal people. The study was performed on 16 healthy adults. We divide two group; group I(n=8); Tape along muscle, group II(n=8); Tape across muscle. Two different method taping were applied to gastrocnemius in two weeks. Spinal motor neuron measurement to evoke H-reflex, the posterior tibial nerve was stimulated. Electroencephalogram measurement for ${\beta}$-SMR, attached to active electrode C3, Cz, C4. The H-reflex, ${\beta}$-SMR results were measured before, immediately, one week later and two week later after the apply taping. The results of this study, spinal motor neuron change of group I were decreased ${\alpha}$-motor neuron and the duration time longer than group II(p<.05). Electroencephalogram change of group I were increased ${\beta}$-SMR and the duration time longer than group II(p<.05). Thus, we knew the taping along muscle was ${\beta}$-SMR brain wave more active and reduces the activity of spinal motor neuron.

Study on Applicability of Stereophotogrammetry to Rock Joint Survey (입체사진측량기법의 암반절리조사에 대한 적용성 연구)

  • Han, Jeong-Hun;Song, Jae-Joon
    • Tunnel and Underground Space
    • /
    • v.17 no.2 s.67
    • /
    • pp.139-151
    • /
    • 2007
  • Stereophotogrammetry is a method to extract information of an interested area by constructing a stereo-image from two or more photos. In this study, the stereophotogrammetry was adopted to obtain the joint orientation and trace length from a sampling window and its measurements were compared with the result by a clinocompass and measuring tape to evaluate the applicability of the stereophotogrammetry to rock joint survey. A commercial stereophotogrammetry program, ShapeMetriX 3D, was used for this purpose. Firstly, the accuracy of the measuring method using ShpaeMetrix 3D was evaluated by a model test. Secondly, joint orientations on a rock slope and tunnel were obtained by using ShapeMetriX 3D and compared with the measurement by a clinocompass. Finally. the effect of base-depth ratio in photographing was evaluated by comparing images with various base-depth ratios, and the usefulness of closed-up photographing on a rock exposure to increase the measurement accuracy was tested. The dip and dip direction of each model plane obtained by ShapeMetriX 3D showed an error ranged between $-5^{\circ}\;and\; 5^{\circ}$ on the basis of the results by the measuring tape. Base-depth ratio proved not to influence the analysis result by ShapeMetriX 3D if all the images were taken without any hidden area. The close-up photographing turned out useful to obtain the detailed images and therefore precise result when ShapeMetriX 3D was adopted.

New UWB 1:2 Power Divider with Flat In-Band Splitting and Bandpass Filtering Functions

  • Duong, Thai Hoa;Kim, Ihn-Seok
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.1
    • /
    • pp.28-34
    • /
    • 2010
  • This paper introduces a new U.S. ultra-wideband(UWB: 3.1~10.6 GHz) 1:2 power divider based on a single section Wilkinson type configuration. The divider provides very flat in-band power splitting, high isolation, low insertion loss, sharp roll-off bandpass filtering, and DC blocking characteristics. The circuit consists of a $\lambda$/4 Y resonator, three capacitively coupled $\lambda$/2 short-circuited lines, and a resistor between the two output ports. The circuit structure was simulated with ADS and HFSS, and realized with low-temperature co-fired ceramic(LTCC) green tape, which has a dielectric constant of 7.8. $|S_{11}|$ better than 10 dB, $|S_{21}|$ and $|S_{31}|$ less than 3.2 dB, with both $|S_{22}|$ and $|S_{32}|$ measured as better than 12 dB for the whole UWB band. Measurement results agree closely with HFSS simulation results. The power divider has a compact size of $4\times9\times0.6mm^3$.

New UWB BPF with Steep Selectivity Based on T-Resonator and Capacitively Coupled λ/4 and λ/2 Line Sections

  • Duong, Thai Hoa;Kim, Ihn-Seok
    • Journal of electromagnetic engineering and science
    • /
    • v.9 no.3
    • /
    • pp.164-173
    • /
    • 2009
  • In this paper, two new circuit structures for European and U.S. ultra-wide band(UWB) bandpass filters(BPFs) with sharp roll-off characteristics are introduced. We show first that the ultra-wide bandpass property is obtained from a $\lambda$/4 open T resonator with a capacitively coupled $\lambda$/4 short-circuited line, which provides two attenuation poles at lower and upper cutoff frequencies. Then, two identical capacitively coupled input/output lines, which can be $\lambda$/4-length open ends or $\lambda$/2-length short ends, with the T-resonator, are adopted to suppress lower and higher frequency components outside of the pass band. There is coupling between the input and output lines providing two additional transmission zeros in the lower and upper transition bands of the filter. Since the coupling between the T-resonator with the $\lambda$/4 short-circuited line and the input/output lines limits the bandwidth of the filter to the European UWB band, both the $\lambda$/4 short-circuited line and the input/output lines are inserted between the two stacked T-resonators for the U.S. UWB band. The filter structures are simulated with ADS and HFSS and realized with low-temperature co-fired ceramic(LTCC) green tape which has the dielectric constant of 7.8. Measurement results agree well with HFSS simulation results.

Wideband Bandstop Filter Based on Capacitively Coupled λ/4 Short-Circuited Lines

  • Duong, Thai Hoa;Kim, Ihn-Seok
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.3
    • /
    • pp.92-98
    • /
    • 2010
  • A new wideband bandstop filter(BSF) with a sharp roll-off characteristic is introduced in a stripline structure in this paper. The BSF consists of two sections: the first is two capacitively coupled $\lambda/4$ short-circuited lines with opposite ground positions, while the second is a capacitively coupled $\lambda/4$ short-circuited line. The BSF provides three transmission zeros within the stopband and better than 22 dB rejection over the whole wireless local area network (WLAN) band from 5.15 to 5.825 GHz. The BSF, cascaded to an U.S. ultra-wideband(UWB: 3.1~10.6 GHz) band-pass filter(BPF), is simulated with HFSS and realized with low-temperature co-fired ceramic(LTCC) green tape with a dielectric constant of 7.8. The measurement results agree well with the HFSS simulation results. The size of the UWB BPF including the BSF is $3{\times}6.3\times0.45\;mm^3$.

Effect of $B_{2}O_{3}$ addition on mechanical strength and microstructure of a porous $LiAlO_{2}$ electrolyte support for molten carbonate fuel cells (용융 탄산염 연료전지용 gamma $LiAlO_{2}$ 전해질 지지체의 미세구조 및 기계적 강도 변화에 대한 $B_{2}O_{3}$ 첨가의 영향)

  • Ham, Hyung-Chul;Yoon, Sung-Pil;Hong, Seong-Ah
    • New & Renewable Energy
    • /
    • v.3 no.1 s.9
    • /
    • pp.54-59
    • /
    • 2007
  • A sintering aid, $B_{2}O_{3}$ have been included into a $LiAlO_{2}$ electrolyte support by a tape casting method in order to reinforce mechanical strength of the support for molten carbonate fuel cells [MCFCs). Starting idea originates from the low melting point of $B_{2}O_{3}$ ($450^{\circ}C$), which can provide the low temperature consolidation of ceramic materials. The mechanical properties and the microstructure changes of the $B_{2}O_{3}$-included electrolyte support were examined by scanning electron microscope, mercury porosimetry, X-ray powder diffraction [XRD], high temperature differential scanning calorimeter and three-point bending strength measurement. The mechanical strength was clearly improved by addition of $B_{2}O_{3}$. The increase of mechanical strength results from the neck growth of a new $LiAlO_{2}$ phase between $LiAlO_{2}$ particles by the liquid phase sintering. Average pore size and porosity of the electrolyte support reinforced by addition of the sintering aid, $B_{2}O_{3}$, was $0.24{\mu}m$ and 59%, respectively which were suitable microstructure of a matrix for an application of MCFCs.

  • PDF

Quench Development in Coated Conductors (Coated Conductor에서의 퀜치 거동)

  • Kim, H.R.;Park, C.R.;Yim, S.W.;Yoo, S.D.;Oh, S.Y.;Hyun, O.B.
    • Progress in Superconductivity
    • /
    • v.10 no.2
    • /
    • pp.149-154
    • /
    • 2009
  • We measured and analyzed the quench development in coated conductor(CC) tapes. The CC was grown on hastelloy substrates and has an Ag protection layer. The tapes were subjected to simulated AC fault currents for quench development measurement. They were immersed in liquid nitrogen during the experiment. The quench resistance increased rapidly first, and the increase slowed down afterwards. It increased linearly with applied voltage at lower voltages, and depended less strongly on applied voltage at higher voltages. The resistance was compared with that of Au/YBCO films grown on sapphire substrates, and found to increase more monotonously than the latter. Data were analyzed quantitatively with the concept of heat transfer within the tape and the surrounding liquid nitrogen. A heat balance equation was derived and solved, taking into consideration temperature dependence of thermal parameters of the tapes. Solutions, together with values of thermal parameters taken from the literature, explained the data well. Cooling by liquid nitrogen affected the quench development considerably at lower applied voltages. Dependence on applied voltages could be also understood quantitatively.

  • PDF

Effectiveness of Home Health Care Service for Elders after Spinal Surgery

  • Jun, Myunghee;Jung, Ji Young
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.7
    • /
    • pp.1009-1018
    • /
    • 2012
  • Purpose: This study was done to evaluate effectiveness of home healthcare services (HHCS) specialized for elders who received spinal surgeries. Methods: A non-equivalent control group pre-post test quasi-experimental study was performed. HHCS was developed based on the Rice model of dynamic self-determination for self-care. For data collection, a control group (n=23) and an experimental group (n=23) were selected by matching age, BMI, pain, general characteristics and type of spine surgery. Measurement tools to evaluate uncertainty and knowledge were developed by the authors. The Numeric Rating Scale (NRS) and Japanese Orthopedic Association Back Pain Evaluation Questionnaire (JOABPEQ) were used to evaluate pain levels. Muscular strength in the legs was measured using a digital muscle tester and tape ruler. Questionnaires were used to evaluate disability in performing ADL and psychological distress levels. Results: The experimental group showed significant decrease in uncertainty (p=.028), increased knowledge (p=.038), and partially decreased pain (p=.003-.331). Partial muscle strength increased significantly (p=.021-.644). Disability in performing ADL and psychological distress in the experimental group decreased significantly compared to control group (p=.002, p=.004). Conclusion: Results indicate HHCS is an efficient home care nursing program for these elders. Further experimental studies with larger samples are required to confirm effects of HHCS.