• 제목/요약/키워드: Tape measurement

검색결과 158건 처리시간 0.032초

디지털경사계를 사용한 체간재위치오류 검사의 신뢰도 분석 (Analysis of Intrarater and Interrater Reliability of Trunk Repositioning Error Test using a Portable Digital Inclinometer)

  • 장우남;이경보;염준우;황병용
    • The Journal of Korean Physical Therapy
    • /
    • 제25권4호
    • /
    • pp.210-216
    • /
    • 2013
  • Purpose: A cost effective tool for the clinical measurement of trunk reposition sense is clearly needed. This study was to analyze intrarater and interrater Reliability of trunk repositioning error (TRE) test which assesses trunk position sense using a portable digital inclinometer. Methods: Twenty four normal healthy subjects were recruited. TRE was measured using a portable digital inclinometer. A digital inclinometer (Acumar-ACU360; Lafayetter Instrument) with precision to $1^{\circ}$ was placed on skin over the spinous process from first to second thoracic vertebra (T1-T2) and secured with double-sided tape. TRE test during sitting forward and lateral flexion movement was assessed. When they reached a point approximately 50% of full trunk flexion range, the examiner instructed the subjects to stop and told them. This was the target position that they should try to reproduce exactly. Each subject performed six trials. Results: ICC (2,1) for intrarater reliability (with-day and between-day) of TRE test in sagittal and frontal plane of movement was 0.75 and 0.78 (excellent reliability). Interrater reliability was 0.66 in sagittal and 0.64, frontal plane (fair to good reliability). However, there were poor correlations between an average of TRE test in sagittal and frontal plane. Conclusion: TRE test using a portable digital inclinometer demonstrated good to excellent reliability. The device may be a cost effective clinical measurement for trunk reposition sense measurement.

20대 여성의 Tight-fit원형설계에 관한 연구 (A Study of Tight-fit Bodice Pattern for 20's Women)

  • 정복희;나미향
    • 대한가정학회지
    • /
    • 제39권8호
    • /
    • pp.137-154
    • /
    • 2001
  • This study was made to draft the tight fitting bodice pattern which horizontal and perpendicular stands are to be lightly set, with the consideration of characteristics of body shape in design of clothes. Measurement of body was conducted on 53 women in twenties, and observation was made on surface development pattern by adhesive tape addition method and gypsum method on three standard objects. In the study, bodice pattern was completed by using already made Somato- measurer, compared with existing bodice pattern, and the results are as follows. The result of the correlation analysis by body measurement shows that chest circumference has a relation to B$.$P-front neck point, side neck point, shoulder point, front interscye breadth point, and the item in spine scapulae point has relation to the item of back neck line, and front & back horizontal values. The degree of shoulder slant, width of armhole and of its depth, the amount of breast, back space, back length were shown to be directly measured from the body. In surface development pattern, tight-fit bodice pattern necessary to the breast volume and back space were shown to be investigated and these volume have to be given in setting up basic line for clothes design together with body measurement value. The result of sensory evaluation for appearance test on fitness shows higher value of research bodice including line of shoulder line, front and back interscye breadth, chest circumference, waist circumference, armhole circumference and of its depth, compared with the research bodice in most items. The result of this study is seen showing high effectiveness for the basic data to design the ready-made dress of high sensitivity of high value added tat.

  • PDF

키네시오 테이핑 적용 방식이 정상인의 척수운동신경원 흥분성과 뇌파 변화에 미치는 영향 (Spinal Motor Neuron and Electroencephalogram Changes after Different Kinesio Taping Method Therapy in normal People)

  • 배세현;김기도;김경윤
    • 한국콘텐츠학회논문지
    • /
    • 제13권11호
    • /
    • pp.791-799
    • /
    • 2013
  • 본 연구는 키네시오 테이핑을 적용하는 방식에 따라 나타나는 척수운동신경원의 흥분성과 뇌파의 변화를 알아보기 위해 실시하였다. 건강한 성인 16명을 대상으로 비복근의 테이핑 적용 방식에 따라 실험군 I(n=8); 근육 주행방향, 실험군 II(n=8); 근육 횡 방향으로 구분하여 2주간 실시하였다. 척수운동신경원 흥분성 측정을 위해 경골신경에 자극을 주어 H 반사를 획득하였으며, 뇌파는 ${\beta}$-SMR를 측정하기 위해 C3, Cz, C4에 활성전극을 붙여 테이핑 적용 전, 즉시, 1주일 후, 2주일 후에 측정하였다. 연구 결과, 실험군I의 척수 운동신경원의 변화는 실험군 II보다 ${\alpha}$-운동신경원의 활성도가 감소하였고 지속 시간도 길었다(p<.05). 뇌파는 실험군I의 ${\beta}$-SMR 활성도가 실험군 II 보다 증가하고 지속시간도 길었다(p<.05). 근육 주행방향에 따른 적용 방식은 횡 방향 보다 ${\beta}$-SMR 뇌파를 더 활성화 시키며, 척수운동신경원의 활성도 감소를 지속적으로 유발함을 알 수 있었다.

입체사진측량기법의 암반절리조사에 대한 적용성 연구 (Study on Applicability of Stereophotogrammetry to Rock Joint Survey)

  • 한정훈;송재준
    • 터널과지하공간
    • /
    • 제17권2호
    • /
    • pp.139-151
    • /
    • 2007
  • 입체사진측량기법이란 대상면에 대하여 두 장 이상의 스테레오 영상을 취득하고 이 영상을 해석함으로써 대상면에 대한 정보론 추출하는 방법이다. 본 연구에서는 기존의 수작업에 의한 암반절리조사 방법에 대한 대안으로서, 입체사진측량기법을 암반절리조사에 적용하여 절리 정보론 추출하였고 그 결과를 비교, 분석함으로써 암반절리조사에의 적용성을 평가하였다. 검증은 실내 모형 시험을 통한 검증과 실제 암반에 대한 검증을 통하여 수행되었다. 현장 적용시 기선거리비가 해석 결과에 미치는 영향을 평가하기 위한 촬영 및 분석을 수행하였고, 해석 자료의 정확도를 향상시키기 위하여 절리 대상면을 분할 확대 촬영하였다. ShapeMetriX 3D프로그램을 이용한 실내 모형 시험 결과, 3차원 공간 좌표의 실측치를 이용한 결과와 비교하여 경사각 및 경사방향에 대하여 모두 ${\pm}5^{\circ}$ 이내의 편차를 보임을 확인하였다. 또한 영상 취득시 폐색 구간이 발생하지 않도록 촬영한다면, 기선거리비가 해석 결과에 미치는 영향이 크지 않음을 알 수 있었다. 따라서 분할 확대 촬영을 통한 취득 자료의 분석은 효율적인 방법으로 판단된다.

New UWB 1:2 Power Divider with Flat In-Band Splitting and Bandpass Filtering Functions

  • Duong, Thai Hoa;Kim, Ihn-Seok
    • Journal of electromagnetic engineering and science
    • /
    • 제10권1호
    • /
    • pp.28-34
    • /
    • 2010
  • This paper introduces a new U.S. ultra-wideband(UWB: 3.1~10.6 GHz) 1:2 power divider based on a single section Wilkinson type configuration. The divider provides very flat in-band power splitting, high isolation, low insertion loss, sharp roll-off bandpass filtering, and DC blocking characteristics. The circuit consists of a $\lambda$/4 Y resonator, three capacitively coupled $\lambda$/2 short-circuited lines, and a resistor between the two output ports. The circuit structure was simulated with ADS and HFSS, and realized with low-temperature co-fired ceramic(LTCC) green tape, which has a dielectric constant of 7.8. $|S_{11}|$ better than 10 dB, $|S_{21}|$ and $|S_{31}|$ less than 3.2 dB, with both $|S_{22}|$ and $|S_{32}|$ measured as better than 12 dB for the whole UWB band. Measurement results agree closely with HFSS simulation results. The power divider has a compact size of $4\times9\times0.6mm^3$.

New UWB BPF with Steep Selectivity Based on T-Resonator and Capacitively Coupled λ/4 and λ/2 Line Sections

  • Duong, Thai Hoa;Kim, Ihn-Seok
    • Journal of electromagnetic engineering and science
    • /
    • 제9권3호
    • /
    • pp.164-173
    • /
    • 2009
  • In this paper, two new circuit structures for European and U.S. ultra-wide band(UWB) bandpass filters(BPFs) with sharp roll-off characteristics are introduced. We show first that the ultra-wide bandpass property is obtained from a $\lambda$/4 open T resonator with a capacitively coupled $\lambda$/4 short-circuited line, which provides two attenuation poles at lower and upper cutoff frequencies. Then, two identical capacitively coupled input/output lines, which can be $\lambda$/4-length open ends or $\lambda$/2-length short ends, with the T-resonator, are adopted to suppress lower and higher frequency components outside of the pass band. There is coupling between the input and output lines providing two additional transmission zeros in the lower and upper transition bands of the filter. Since the coupling between the T-resonator with the $\lambda$/4 short-circuited line and the input/output lines limits the bandwidth of the filter to the European UWB band, both the $\lambda$/4 short-circuited line and the input/output lines are inserted between the two stacked T-resonators for the U.S. UWB band. The filter structures are simulated with ADS and HFSS and realized with low-temperature co-fired ceramic(LTCC) green tape which has the dielectric constant of 7.8. Measurement results agree well with HFSS simulation results.

Wideband Bandstop Filter Based on Capacitively Coupled λ/4 Short-Circuited Lines

  • Duong, Thai Hoa;Kim, Ihn-Seok
    • Journal of electromagnetic engineering and science
    • /
    • 제10권3호
    • /
    • pp.92-98
    • /
    • 2010
  • A new wideband bandstop filter(BSF) with a sharp roll-off characteristic is introduced in a stripline structure in this paper. The BSF consists of two sections: the first is two capacitively coupled $\lambda/4$ short-circuited lines with opposite ground positions, while the second is a capacitively coupled $\lambda/4$ short-circuited line. The BSF provides three transmission zeros within the stopband and better than 22 dB rejection over the whole wireless local area network (WLAN) band from 5.15 to 5.825 GHz. The BSF, cascaded to an U.S. ultra-wideband(UWB: 3.1~10.6 GHz) band-pass filter(BPF), is simulated with HFSS and realized with low-temperature co-fired ceramic(LTCC) green tape with a dielectric constant of 7.8. The measurement results agree well with the HFSS simulation results. The size of the UWB BPF including the BSF is $3{\times}6.3\times0.45\;mm^3$.

용융 탄산염 연료전지용 gamma $LiAlO_{2}$ 전해질 지지체의 미세구조 및 기계적 강도 변화에 대한 $B_{2}O_{3}$ 첨가의 영향 (Effect of $B_{2}O_{3}$ addition on mechanical strength and microstructure of a porous $LiAlO_{2}$ electrolyte support for molten carbonate fuel cells)

  • 함형철;윤성필;홍성안
    • 신재생에너지
    • /
    • 제3권1호
    • /
    • pp.54-59
    • /
    • 2007
  • A sintering aid, $B_{2}O_{3}$ have been included into a $LiAlO_{2}$ electrolyte support by a tape casting method in order to reinforce mechanical strength of the support for molten carbonate fuel cells [MCFCs). Starting idea originates from the low melting point of $B_{2}O_{3}$ ($450^{\circ}C$), which can provide the low temperature consolidation of ceramic materials. The mechanical properties and the microstructure changes of the $B_{2}O_{3}$-included electrolyte support were examined by scanning electron microscope, mercury porosimetry, X-ray powder diffraction [XRD], high temperature differential scanning calorimeter and three-point bending strength measurement. The mechanical strength was clearly improved by addition of $B_{2}O_{3}$. The increase of mechanical strength results from the neck growth of a new $LiAlO_{2}$ phase between $LiAlO_{2}$ particles by the liquid phase sintering. Average pore size and porosity of the electrolyte support reinforced by addition of the sintering aid, $B_{2}O_{3}$, was $0.24{\mu}m$ and 59%, respectively which were suitable microstructure of a matrix for an application of MCFCs.

  • PDF

Coated Conductor에서의 퀜치 거동 (Quench Development in Coated Conductors)

  • 김혜림;박충렬;임성우;유승덕;오성용;현옥배
    • Progress in Superconductivity
    • /
    • 제10권2호
    • /
    • pp.149-154
    • /
    • 2009
  • We measured and analyzed the quench development in coated conductor(CC) tapes. The CC was grown on hastelloy substrates and has an Ag protection layer. The tapes were subjected to simulated AC fault currents for quench development measurement. They were immersed in liquid nitrogen during the experiment. The quench resistance increased rapidly first, and the increase slowed down afterwards. It increased linearly with applied voltage at lower voltages, and depended less strongly on applied voltage at higher voltages. The resistance was compared with that of Au/YBCO films grown on sapphire substrates, and found to increase more monotonously than the latter. Data were analyzed quantitatively with the concept of heat transfer within the tape and the surrounding liquid nitrogen. A heat balance equation was derived and solved, taking into consideration temperature dependence of thermal parameters of the tapes. Solutions, together with values of thermal parameters taken from the literature, explained the data well. Cooling by liquid nitrogen affected the quench development considerably at lower applied voltages. Dependence on applied voltages could be also understood quantitatively.

  • PDF

Effectiveness of Home Health Care Service for Elders after Spinal Surgery

  • Jun, Myunghee;Jung, Ji Young
    • 대한간호학회지
    • /
    • 제42권7호
    • /
    • pp.1009-1018
    • /
    • 2012
  • Purpose: This study was done to evaluate effectiveness of home healthcare services (HHCS) specialized for elders who received spinal surgeries. Methods: A non-equivalent control group pre-post test quasi-experimental study was performed. HHCS was developed based on the Rice model of dynamic self-determination for self-care. For data collection, a control group (n=23) and an experimental group (n=23) were selected by matching age, BMI, pain, general characteristics and type of spine surgery. Measurement tools to evaluate uncertainty and knowledge were developed by the authors. The Numeric Rating Scale (NRS) and Japanese Orthopedic Association Back Pain Evaluation Questionnaire (JOABPEQ) were used to evaluate pain levels. Muscular strength in the legs was measured using a digital muscle tester and tape ruler. Questionnaires were used to evaluate disability in performing ADL and psychological distress levels. Results: The experimental group showed significant decrease in uncertainty (p=.028), increased knowledge (p=.038), and partially decreased pain (p=.003-.331). Partial muscle strength increased significantly (p=.021-.644). Disability in performing ADL and psychological distress in the experimental group decreased significantly compared to control group (p=.002, p=.004). Conclusion: Results indicate HHCS is an efficient home care nursing program for these elders. Further experimental studies with larger samples are required to confirm effects of HHCS.