• 제목/요약/키워드: Tap water

검색결과 888건 처리시간 0.029초

음용수의 섭취량 및 다경로 노출평가를 위한 노출변수 조사연구 (Daily Water Intake and Exposure Parameters Related to the Multi-route Exposure in Drinking Water)

  • 정용;신동천;박성은;최시내;박선미
    • Environmental Analysis Health and Toxicology
    • /
    • 제11권1_2호
    • /
    • pp.19-29
    • /
    • 1996
  • Human exposure to volatile compounds in tap water can occur from inhalation and dermal absorption as well as direct ingestion. The relative contribution to total human exposure from these pathways has been considered to be important especially for VOC's (volatile organic compounds). In an attempt to reduce the uncertainty of the risk assessment, it has been suggested that the exposure assessment process could be significantly improved by adopting Monte-Carlo simulation. However, there is no actual data in Korea for each exposure parameter to determine the level of exposure, and the distributional pattern. Therefore, we surveyed water use patterns and behavior related to multi-route exposure to VOC's in household tap water in Korea, and compared these values to the those in western countries. In the first survey, we calculated daily water intake using data from a sample of 1322 persons of several cities in Korea. In the second survey, we obtained questionnaire data on exposure time for showering, bathing and household activities, and tap water intake from 851households in Korea. In the last survey, we measured the exposure parameters (exposure time, water use rate etc.) related to showers, baths, toilets, dish washing, washing and cooking, and tap water intake was surveyed. Also, the subjects were measured their body weight, height and tidal volume, etc. A diary, a flow meter and a measuring cup were used to measure these values as precisely as possible. Average daily water intake was ranged 0.79-1.71 L/day for adults in three surveys. Tap water intake measured by log-sheet during one week in third survey was 1.26 (average), 1.98 L/day (90 percentlie), respectively. These results were comparable with results from EPA (1.4, 2L/day). The average amount of water used by housewives in the third survey was 515.0 $\pm$ 564.6L/day. In usual activity, the amount of water used in the bathroom, the laundry and the kitchen was 140.0 $\pm$ 538.9, 148.0 $\pm$ 174.5, 229.3 $\pm$ 205.4 L/day, respectively. Exposure parameters such as water intake rate, exposure duration, body weight, inhalation rates in surveyed data of Korean people differed from those published from western countries. This could be attributed to variations in lifestyle, dietary habits and physiological characteristics.

  • PDF

청량음료의 미생물 오염에 대하여 (On the Microbial Contamination in Softdrink Manufacturing Process)

  • 김용배;이병국;유건희;조남선
    • 미생물학회지
    • /
    • 제11권3호
    • /
    • pp.129-133
    • /
    • 1973
  • The authors have investigated about the microbial contamination of goods which is a criterion of hygienic control. Conducting on investigation, a special attention has been paid on the rate of microbial contamination in the goods, especially in manufacturing process of the softdrink. The authors also made an experiment on total microbes which is the criterion of contamination in each step of the process and in raw materials together with materials to be used for subdividing. Results obtained were as follows : 1) The orgin of microbial contamination was found in bottle cap and in tap water, that is, there appeared 9 colony per ml in bottle cap and 31-74 colony per ml in tap water, respectively. 2) It was found that microbial contamination are 4 colony per ml in average through year. However, it appeared 1 colony per ml in winter and 8 colony per ml in summer. 3) Coliform groups are not detected in goods through a year. 4) There was no variation in number of total microbes after ion exchange resin passage in purification process of tap water. 5) The number of microbes in goods are decreased when the raw materials are treated in high temperature short time (HTST) sterilization.

  • PDF

초음파와 자외선(UV) 동시 적용이 가정용 가습기 내 살균에 미치는 시너지 효과에 대한 반응속도론적 연구 (Kinetic examination on synergistic effect of co-use of ultrasonic wave and ultraviolet radiation on bacterial disinfection in a household humidifier)

  • 김성아;김지현;이민주;김자연;정우식;박준홍
    • 상하수도학회지
    • /
    • 제35권3호
    • /
    • pp.227-235
    • /
    • 2021
  • This study examined the effect of ultraviolet (UV) application on bacterial disinfection in a commercialized humidifier using ultrasonic wave (UW). To accurately examine disinfection kinetics in tap-water condition, tap-water was sterilized using a filter, and then inoculated with pure cultures of E. coli and P. putida with known viable counts. The disinfection kinetic characteristics were experimentally compared when UV alone, UW alone, and UW+UV together were applied in disinfecting the added bacteria in the commercialized humidifier. When UV alone was applied, bacterial disinfection kinetics followed a first-order decay reaction, and showed an approximately 10-time weaker disinfection compared to the typical UV disinfection in water treatment or wastewater treatment. When UW alone was applied, bacterial disinfection kinetics followed a second-order decay reaction with a low disinfection rate constant of 0.0002 min-1(CFU/mL)-1. When UV and UW were applied together, however and interestingly, the disinfection rate constant (0.0211 min-1(CFU/mL)-1) was approximately 100 times increased than that for the UW alone case. These results revealed that the co-use of UV and UW can provide synergistic effect on bacterial disinfection in a tap-water condition in household humidifiers.

수도 서비스의 진화! 소비자 중심의 스마트 물 관리 - Smart Water City 시범사업 - (Evolution of Water supply system! Smart Water Management for customer - Smart Water City Pilot Project -)

  • 김재복
    • 상하수도학회지
    • /
    • 제29권4호
    • /
    • pp.511-517
    • /
    • 2015
  • Korea's modern waterworks began with construction of DDukdo water treatment plant in 1908 and has been growing rapidly along with the country's economic development. As a result, water supply rates have reached 98.5% based on 2013. Despite multilateral efforts for high-quality water supply, such as introduction of advanced water treatment process, expansion of waterworks infrastructure and so on, distrust for drinking tap water has been continuing and domestic consumption rate of tap water is in around 5% level and extremely poor comparing to advanced countries such as the United States(56%), Japan(52%), etc. Recently, the water management has been facing the new phase due to water environmental degradation caused by climate change, aging facilities, etc. Therefore, K-water has converted water management paradigm from the "clean and safe water" to the "healthy water" and been pushing the Smart Water City(SWC) Pilot Project in order to develop and spread new water supply models for consumers to believe and drink tap water through systematic water quality and quantity management combining ICT in the whole water supply process. The SWC pilot projects in Pa-ju city and Go-ryeong county were an opportunity to check the likelihood of the "smart water management" as the answer to future water management. It is needed to examine the necessity of smart water management introduction and nationwide SWC expansion in order to improve water welfare for people and resolve domestic & foreign water problems.

물 수요관리를 위한 물 사용실태 및 물 절약 설문조사 (Survey on water utilization status and saving mind for water demand management)

  • 임봉수;권정인;저소웅;이범희
    • 상하수도학회지
    • /
    • 제32권6호
    • /
    • pp.507-515
    • /
    • 2018
  • The results of the survey on water utilization status, the wasted water factor, the awareness, and the education and promotional activities of water saving in Daejeon City are as follows: The percentage of using tap valve with a closure was 66% when showering. 74% of water was used with closing the tap valve when washing faces with no water needed, it was still considered that there existed a wasting water. The most wasting reasons of water were found to be shower, bath, and laundry in order. In the awareness of practicing tap water saving, 9.1% of respondents acted actively, 53.4% of them were trying to practice it, and more than 63% had a positive awareness. In the contents of practicing saving water, locking water when soaping while showering, non-laundry of small quantity, and using cups when brushing teeth were top priorities. About 50% of the reasons for saving water was to practice purely saving water, when saving for economic help was excluded. The level of water saving awareness was not high when considering that the ratio of usage without water saving equipment and installation, and using method was relatively high when moving in. In order to make usage of water saving equipment more common, it was deemed necessary to provide information on the purchase of water saving equipment and to promote and educate the efficiency of saving of related products. More than about 90% of the respondents responded that water saving education or promotional activities had an effect of improving water saving awareness. The most effective method of education and promotional activities was found to be 40.4% by mass media activities, and 21.7% by promotions through mobile devices.

이상적인 음료수 공급을 위한 수질관리에 관한 연구 (Study on the Water Management to get High Quality of Drinking Water)

  • 김형석;신현덕;박경석
    • 환경위생공학
    • /
    • 제6권1호
    • /
    • pp.7-25
    • /
    • 1991
  • Until now, pure drinking water grnerally menas the water without taste, odor, general bacteria, coliform, and other exotic substance. Such a definition has been changing recently due to the finding of numerous other inorganic and organic substances unknown to us. 10 years ago, major causes of death were infectious agents and parasites contained in water, but recently, it has become apparent that some substances contained in drinking water cause cancer and heart diseases. We must drink about 2L of water everyday in order to maintain healthy condition. Waters used for drinking include tap water, well water, spring water, filtered water, etc., but the quality of drinking water has more polluted due to the industrial development and population increase. For example, industrial waste waters from industrial plants pollute the water supply sources ; toxic substances contained in the waste waters pollute the ground water sources by penetrating the geological strata, and municipal, livestock, public building waste waters also pollute the water supply sources. Sometimes, the polluted surface waters were announced to be polluted by various kinds of orgainc substance, and it is reported that the pollution of ground water by orga nic substances has few in number but high in its concectration comparing with those of surface water. As the water quality pollution level increases, so the amount of disinfectant also increase. For example, chlorine solution, one of widely used disinfectants, creates trihalomethane(THM), a carcinogen, and halogen compounds. According to Oliver, through chlorine disinfection process, humine substance and chlorine create bolatile organic halide and nonvolatile organic halide by chemical reaction. There are tens or hundreds filtering devices, but filtering principles and maintenance metjhods are different, so their efficiency tests are needed. According to Smith, the effeciency tests aginst over 30 Ameican filtering devices show that 10 devices can remove 85% of volatile organics and further studies on filtered waters are underway. In consideration of important impacts of polluted drinking water on national health, authors studied the state of water quality pollution against tap water used as drinking water, filtration device passed water, ground water, and conserved drinking water ; tested the efficiency of filtration devices for tap water ; tried to sep up the detection method by using ion chromatography based on negative ion and positive ion by using single column, and attemped the simple filtration method for general households.

  • PDF

도시 수자원으로서의 상수.우수, 하수에 대한 열적 포텐셜의 평가 (Evaluation on Thermal Potential of Tap Water, Rain Water, Waste Water as City Water System)

  • 정용현;;이헌모;윤종호;오은주
    • 환경위생공학
    • /
    • 제13권2호
    • /
    • pp.26-33
    • /
    • 1998
  • It has been referred as a problem that heat source/sink is distance from heat demand area in using unused energy. To solve the distance problem in using unused energy, the water from city water system like tap water, rain water, waste water used as unused energy. To survey the potential of the water of city water system, it is developed that the calculation method of the potential using unit method. The amount of theoretical unused energy and energy saving in the Osaka City, Japan were estimated by using that method.

  • PDF

제주 용암해수로 제조한 쿠키의 품질특성 (Quality of Cookies Formulated with Jeju Magma Seawater)

  • 정성현;전수정;미카일영;문유진;홍예은;권미라
    • 한국식품조리과학회지
    • /
    • 제33권3호
    • /
    • pp.292-299
    • /
    • 2017
  • Purpose: The present study explored cookie making performance using Jeju magma seawater to elucidate the effects of minerals in water on quality of baked goods. Methods: Seven water samples were analyzed for their mineral content, pH and water hardness. Starch pasting properties of flour in water samples was analyzed using RVA, and cookie making performance using water samples was evaluated with the AACCI wire-cut cookie baking method. Quality of cookies was measured by weight loss during baking, cookie geometry, color, and firmness. Results: Hardness of water samples ranged from 0-4200, and mineral content was in the order of magma seawater > 100% ED mineral water > 50% ED mineral water > 10% ED mineral water > tap water > Samdasoo > distilled water. RVA results showed that water hardness exhibited significant relationships with pasting temperature (p<0.05, R=0.863), peak viscosity (p<0.001, R=0.944), final viscosity (p<0.05, R=0.861), and setback (p<0.05, R=0.782). Cookie baking results showed that cookie diameter increased in the order of magma seawater < 100% ED mineral water < 50% ED mineral water < 10% ED mineral water $\approx$ tap water < Samdasoo < distilled water. Conclusion: As mineral content in water increased, flour pasting temperature and viscosity increased, whereas cookie diameter decreased with color fading. However, cookies formulated with 50% ED mineral water showed similar cookie geometry and texture to those with tap water. Therefore, controlling the mineral content of water can be successfully applied to produce mineral-enriched cookies.

가정에서 수돗물 사용 중에 방출되는 chloroform에 대한 흡입노출 (Inhalation Exposure to Chloroform Released from Household Uses of Chlorinated Tap Water)

  • 신혜숙;김희갑
    • 한국물환경학회지
    • /
    • 제20권2호
    • /
    • pp.120-125
    • /
    • 2004
  • Exposure to volatile disinfection by-products (DBPs) such as chloroform included in chlorinated tap water can occur during household activities via inhalation as well as ingestion and dermal absorption. This study was conducted to examine the significance of inhalation route of exposure since humans are unintentionally exposed to volatile DBPs while staying home. Two sets of experiments were carried out in an apartment to measure: 1) the variation of chloroform concentrations in the living room air following kitchen activities (cooking and dish-washing); and 2) the variation of chloroform concentrations in the bathroom and living room following showering. Cooking, dish-washing, and showering all contributed to the elevation of household chloroform levels. Even a few minutes of natural ventilation resulted in the reduction of the chloroform levels to the background. Estimates of daily chloroform doses and lifetime cancer risks suggested that inhalation of household air during staying home be a major route of exposure to chloroform and that ingestion be a minor one in Korean people. It is also suggested that ventilation be a simple and important measure of mitigating human exposure to volatile DBPs indoors.

PC 카메라를 이용한 수돗물의 과망간산칼륨소비량 적정 자동화 (Automatic Titration for KMnO4 Consumption Test of Tap Water Using Personal Computer Camera)

  • 이형춘
    • 한국환경보건학회지
    • /
    • 제34권1호
    • /
    • pp.95-100
    • /
    • 2008
  • An automatic titration system using a PC-camera with a color filter on its lens was used in the $KMnO_4$ consumption test of tap water and distilled water in relation to blank tests. The very faint pink color of titration end point could be effectively detected by using a yellow cellophane paper as a color filter. The average hue value (Havg) of 192 pixels in the image of the sample solution being titrated was computed and followed up at regular time intervals during titration in order to detect the titration end point. The Havg decrease of 2 degrees from the average of first 10 Havgs was regarded as reaching the end point. The volume of 0.01N $KMnO_4$ consumed by a tap water sample was $0.728{\pm}0.022ml$ in manual titration and $0.735{\pm}0.013ml$ in automatic titration (p=0.580). The volume of 0.01N $KMnO_4$ consumed by a distilled water sample was $0.383{\pm}0.015ml$ in manual titration and $0.367{\pm}0.015ml$ in automatic titration (p=0.252). The high p-values for t-test suggested that there were good agreements between manual and automatic titration data and the automatic method proposed in this article was considered to effectively replace the manual titration.