• Title/Summary/Keyword: Tank mixture

Search Result 86, Processing Time 0.026 seconds

CFD Simulation for Mixture Characteristic of DME-Propane Liquified Fuels (DME-Propane 액화연료의 혼합특성에 대한 CFD 시뮬레이션)

  • Kim, Cha-Hwan;Chun, Seuk-Hoon;Shin, Dong-Woo;Kim, Lae-Hyun;Lee, Hyun-Chan;Baek, Young-Soon
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.328-333
    • /
    • 2012
  • In this study, CFD simulation was performed with commercial CFD code FLUENT for the 3D mixing tank model (1 m in a diameter and 2.5 m in a height) of DME-Propane liquified fuels. Initial condition set-up with existence of DME 146 l at the upper side of mixing tank and Propane 770 l at the lower side of mixing tank. Characteristics of mixture and fluid flow were observed for 34 hours simulation. Two liquid fuel were uniformly mixed within range of 3 mol% after 24 hours, and range of 1 mol% after 34 hours. The simulation result following 4 hours was verified with KOGAS experimental data.

Material Development of Eco Water Tank with High Density Polyethylene and Low-temperature Concrete (친환경 저수조를 위한 고밀도 폴리에틸렌과 저열성 콘크리트 합성재료 개발)

  • Chang, Chun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.133-140
    • /
    • 2010
  • The purpose of this study is to evaluate the new eco water tank which is made of high density polyethylene and concrete with low temperature cement. The strength and failure mode of eco water tank was examined through tensile test with mixture of concrete and HDPE, temperature monitoring for various kind of concrete, admixture contains etc. The strength and failure mode were examined through tensile test with mixture of concrete and HDPE, temperature monitering for different kinds of concrete, strength test with different admixtures etc. It was found that shear connector between concrete and HDPE effects significantly contributed to the combined structures. ㄱ type shear connector results in tensile strength of up to 40% compared to that of V type shear connector. Based on test result, the new eco composite tank improved the stability and safety the old one and demonstrated the applicability and capability.

Comparison of EG/AD/S and EG/AD model ice properties

  • Kim, Jung-Hyun;Choi, Kyung-Sik
    • International Journal of Ocean System Engineering
    • /
    • v.1 no.1
    • /
    • pp.32-36
    • /
    • 2011
  • EG/AD/S type model ice was originally selected as the primary model ice material for the MOERI ice tank in Korea. The existence of a sugar component in the EG/AD/S mixture may cause a serious maintenance problem. In order to understand the influence of sugar in the original model ice, a series of tests with EG/AD/S and EG/AD model ices were performed, and their material properties compared. Because the target strength of model ice in the full-scale MOERI ice tank is expensive and difficult to control, tests were performed under cold room conditions using a miniature ice tank. This paper describes the material properties of EG/AD/S and EG/AD model ices, such as flexural strength, compressive strength and elastic modulus. In order to obtain the desired strength and stiffness levels for the model ice, a warm-up process was introduced.

Investigation of condensation with non-condensable gas in natural circulation loop for passive safety system

  • Jin-Hwa Yang;Tae-Hwan Ahn;Hwang Bae;Hyun-Sik Park
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1125-1139
    • /
    • 2023
  • The system-integrated modular advanced reactor 100 (SMART100), an integral-type pressurized water small modular reactor, is based on a novel design concept for containment cooling and radioactive material reduction; it is known as the containment pressure and radioactivity suppression system (CPRSS). There is a passive cooling system using a condensation with non-condensable gas in the SMART CPRSS. When a design basis accident such as a small break loss of coolant accident (SBLOCA) occurs, the pressurized low containment area (LCA) of the SMART CPRSS leads to steam condensation in an incontainment refuelling water storage tank (IRWST). Additionally, the steam and non-condensable gas mixture passes through the CPRSS heat exchanger (CHX) submerged in the emergency cooldown tank (ECT) that can partially remove the residual heat. When the steam and non-condensable gas mixture passes through the CHX, the non-condensable gas can interrupt the condensation heat transfer in the CHX and it degrades CHX performance. In this study, condensation heat transfer experiments of steam and non-condensable gas mixture in the natural circulation loop were conducted. The pressure, temperature, and effects of the non-condensable gas were investigated according to the constant inlet steam flow rate with non-condensable gas injections in the loop.

Weed control efficacy of the tank-mixture between quizalofop-P-ethyl and KSC-35089, a newly synthesized N-arylphthalimide compound (신규합성된 N-arylphthalimide 화합물 KSC-35089와 Quizalofop-ethyl의 혼합처리효과)

  • Kim, Tae-Joon;Song, Jae-Eun;Choi, Jung-Sup;Kim, Hyoung-Rae;Pyon, Jong-Young;Cho, Kwang-Yun
    • The Korean Journal of Pesticide Science
    • /
    • v.6 no.3
    • /
    • pp.183-192
    • /
    • 2002
  • Herbicidal effect of KSC-35089, a newly synthesized N-arylphthalimide compound, was examined, and its interaction with quizalofop-P-ethyl when foliar applied as a tank-mixture was evaluated under a greenhouse condition. KSC-35089 showed stronger herbicidal activity on broadleaves than grasses, suggesting that it would be an appropriate partner for non-selective weed control with quizalofop-P-ethyl, a strong grasskilling ageant. In general, the interaction between KSC-35089 and quizalofop-P-ethyl appeared to be additive, which indicates each compound acts on whole plant level independently. This additive interaction was confirmed in a spectrum test using 19 grasses and 26 broadleaves. Under the greenhouse condition, all tested plants were controlled around 90% level through a foliar application with a tank-mixture of KSC-35089 at 64 g ai/ha and quizalofop-P-ethyl at 32 g ai/ha. Further study would be required on the action mechanism of this additive interaction.

The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures II: The Cause for Foul Odors of Sewer Pipes in Residential Areas (대규모 아파트 단지주변 하수관로의 악취 발생과 대책 II: 주거지역 하수관로의 악취원인과 대책)

  • Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.631-639
    • /
    • 2007
  • This study investigated the construction and operation status of sewer pipes and water-purifier tanks near densely populated areas like large apartment complexes, in order to find out cause for offensive orders. The study results revealed that the main cause arose from the water-purifier tank and public sewer pipes near ordinary residential areas. First, in case of independent water-purifier tanks, the air is forced into the rotten part of large tanks nearby which should be operated in an anaerobic state, so that the tank changes into an aerobic state, or dirty water, which is returned during the sludge return process, falls on the top of the rotten tank, preventing scum from forming within the tank. Such problems cause incompletely purified water in the purifier tank to be discharged, which in turn results in filthy water. Second, in case of public sewer pipes, deteriorated or aging pipes, or the mixture of rain water and dirty water by mixing up combined and separated sewers system can cause foul odors in residential areas. Therefore, offensive odors in residential areas can be radically reduced through the appropriate construction and management of facilities including water-purifier tanks. As well, if more separate sewers are installed as part of an improvement project for public sewer pipes, complaints about foul smell can be minimized.

The treatment of sewage using DAF pump system with micro bubble and non-powered flotation tank (응집제 자동혼합형 미세기포 발생장치와 무동력 부상분리조를 이용한 하수의 처리)

  • Kim, Dong-Ha;Lee, Soo-Young;Jung, Eui-Taek
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.659-666
    • /
    • 2011
  • Although DAF(Dissolved Air Flotation) has been successfully accepted for water and wastewater treatment, the fundamental characteristics of the process have not been fully investigated. Water is saturated with compressed air to dissolve the air into the water at high pressure in saturation tank. Then the water containing dissolved air is released into a floatation tank at a lower pressure, generating micro-bubbles that rise gently through the water and carry the suspended matter to the surface. This study investigated the removal of sewage using automatic mixture type DAF pump and non-powered flotation tank. Characteristics of two devices were compared and analyzed with samples. The results showed that the PAC exhibited higher performance than other coagulants. When air dosage was 2.5ml/l/min, treatment was stable in operation. In the DAF pump with a pressure of 4 atm., the average size of bubbles was 36.2${\mu}m$. Removal efficiency of SS was 80%. At this time removal efficiency of COD was about 80%, of T-N was 30% and T-P was 70% in stable operation. It was concluded that DAF pump system with micro bubble performed higher efficiencies compared to general DAF system for treating wastewater.

Construction and Evaluation of Thermal Crack Stability about Bottom Slab of the #219 LNG Underground Tank in Incheon (인천 LNG 지하탱크 #219 Bottom Slab시공 및 온도균열 안정성 평가)

  • Son, Young-Jun;Ha, Jae-Dam;Um, Tai-Sun;Lee, Jong-Ryul;Park, Jong-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.689-692
    • /
    • 2006
  • The crack of concrete induced by the heat of hydration is a serious problem, particularly in massive concrete structures. In order to control the temperature crack of massive concrete, the selection of appropriate materials like low heat cement, mixture materials, etc. is essential. In tills study, mix proportion using low heat portland cement and lime stone powder was designed and the best mix proportion, B-1, was selected. When bottom slab of the #219 LNG tank in Incheon was constructed, concrete temperature was measured. And thermal stress was analyzed about bottom slab of the LNG tank. As results of the thermal analysis, crack index was 1.60 in bottom slab and satisfied with construction specifications(over 1.0).

  • PDF

Suggestion of the Analysis Model and Verification on Rotating Flow in Stirred Tanks Using CFD (전산유체역학을 이용한 교반 탱크 내에서의 회전유동에 대한 해석 모델의 제안 및 검증)

  • Hwang, Seung Sik;Yong, Cho Hwan;Choi, Gyuhong;Shin, Dohghoon;Chung, Tae Yong
    • Journal of Energy Engineering
    • /
    • v.22 no.1
    • /
    • pp.28-37
    • /
    • 2013
  • Stirred tank is widely used in various industries for mixing operations and chemical reactions for single- or multi-phase fluid systems. For designing agitator of high performance, quantity data of internal flow characteristics influenced by mixing performance are definitely confirmed but quantity analysis about the transient flow characteristics of complicate structure is recognized as difficult problem in the present. In this study, two models of commercial CFD code Fluent 6.3 used to propose suitable for the tank analysis. Agitation of Stirred tank is analyzed using a mixed model and the flow in the stirred tank is analyzed using a standard k-${\varepsilon}$ model. Multiple reference frame(MRF) and Sliding mesh(SM), the analysis techniques were used For compare a result of CFD with a visualization experiment result, to grasp internal flow and mixing characteristic in stirred tank and to present fundamental analysis method.