• Title/Summary/Keyword: Tank and tap water

Search Result 30, Processing Time 0.029 seconds

Electrical resistivity monitoring of a scale model experiment for geological $CO_2$ sequestration (전기비저항에 의한 지중저장 이산화탄소 거동관측 모의실험)

  • Park, Mi-Kyung;Jang, Han-Nu-Ree;Kim, Hee-Joon;Wang, Soog-Yun;Lee, Min-Hee
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.173-178
    • /
    • 2007
  • Time-lapse electrical resistivity measurements have been made in a scale model experiment for geological $CO_2$ sequestration in aquifer. Three types of $CO_2$ injection are tested in a water tank filled with glass beads. These are $CO_2$ dissolved into filtered tap water, $CO_2$ gas, and mineral oil. The mineral oil is a substitute for liquid phase of supercritical $CO_2$. For reconstructing three-dimensional resistivity images, we measure potential differences at 32 potential dipoles on the top surface of the tank due to two current dipoles on the front and back sides. The resultant resistivity images clearly show the movement of injected $CO_2$ in aquifer.

  • PDF

Characteristics of Bioaerosol Generation of Household Humidifiers by User Practices (가정용 가습기의 사용자 습관에 따른 실내공기 중 바이오에어로졸의 발생특성)

  • Kim, Ik-Hyeon;Kim, Ki Youn;Kim, Daekeun
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.6
    • /
    • pp.503-509
    • /
    • 2012
  • Objectives: This study was performed in order to evaluate the generation characteristics of airborne bacteria and fungi while operating a household humidifier, in consideration of user habits. Methods: Microbial samples were collected in a closed chamber with a total volume of 2.76 $m^3$, in which a humidifier was operated according to experimental strategies. A cultivation method based on the viable counts of mesophilic heterotrophic bacteria and fungi was performed. Experimental strategies were divided into three classes: the type of water in the water reservoir (tap water, cooled boiled water); the frequency of filling the reservoir (refill every day, no refill); and the sterilization method (sterilization function mode, humidifier disinfectants). Results: Significant increases in the concentration of airborne bacteria were observed while the humidifier was in operation. The concentration had increased to 2,407 $CFU/m^3$ by 120 hours when tap water filled the reservoir without any application of sterilization, while for cooled boiled water, it was merely 393 $CFU/m^3$ at a similar time point. Usages of disinfectant in the water tank were more effective in decreasing bioaerosol generation compared to sterilization function mode operation. Generation characteristics of airborne fungi were similar to those of bacteria, but the levels were not significant in all experiments. Calculated exposure factor can be used as an indicator to compare biorisk exposure. Conclusion: This study identified the potential for bioaerosol generation in indoor environments while operating a household humidifier. User practices were critical in the generation of bioaerosol, or more specifically, airborne bacteria. Proper usage of a humidifier ensures that any biorisks resulting from generated bioaerosol can be prevented.

Isolation and Identification of Legionella pneumophila from Hot Water Spouts and Hot Water (溫水수도꼭지와 온수에서 Legionella pneumophila의 分離同定)

  • Park, Ju-Hyeong;Zong, Moon-Shik
    • Journal of Environmental Health Sciences
    • /
    • v.14 no.1
    • /
    • pp.23-32
    • /
    • 1988
  • A study was carried out to find distribution of Legionella spp. in hot water supplying systems of buildings in Seoul. Water samples were taken from the hot water taps in three research institute buildings during the period from the 2nd to 27th February, 1987. And all of the three buildings were supplied with hot water from the same central hot water tank. GVPC BCYEa and blood agar were used for the isolation of Legionella pneurnophila and slide agglutination test (SAT) was performed to identify their strain types. Main findings were as follows 1. 44 samples taken from hot tap-water revealed 20% of positive culture and 44 samples taken from hot water spouts revealed 11% of positive culture. 2. The 78% of positive samples taken from hot water was obtained from 25.1$\circ$C~45.0$\circ$C temperature range. 3. Only, Legionella pneumophila serogroup 3 was identified and most of them has been than 2$\mu$m in length. 4. The densities of the Legionella pneurnophila isolated from hot water samples were within the range of $1.0\times 10^2$ to $1.1\times 10^3$ CFU/l and their densities isolated from hot water spouts were either 1 CFU/plate or 2 CFU/plate.

  • PDF

A Study on the Development and Improvement of Simple Piped Water Supply System in Rural Area of Korea (농촌지역 간이상수도시설 개발 및 개선에 관한 연구)

  • Chung, Yong;Koo, Ja-Kon;Kim, Myung-Ho;Yun, Suk-Woo;Kim, In-Sook
    • Journal of agricultural medicine and community health
    • /
    • v.13 no.1
    • /
    • pp.19-25
    • /
    • 1988
  • It is very important to supply safe drinking water for rural area not only a prevention of entric diseases but also a promotion of health life. It is estimated that 6,981,000 rural inhabitants were covered by the simple piped water supply system at the end of 1987 in Korea. The programme for improvement of water supply system in rural villages was initiated by the government since 1967. But most of these systems have been operated carelessly by the hands of villagers who have no proper knowledge and experience. Since most of water sources were located nearby farmland, there might be a possibility that the sources could be contaminated by pesticides and fertilizers. For this reason, it is recommended to take underground water as a water source rather than surface water such as a pond or streamwater in rural areas. However, the system is supplied from the surface water, its water quality can be improved by using of simple sand filter and simple chlorinator inexpensively. On the basis of an on-site study, conducted during 1986-87, in San-Buk Village, Keum-Sa-Myon, Yeju-Gun, Kyong-Gi-Do, the new simple piped water supply system was designed by the Institute for Environmental Research, Yonsei University, and constructed by the villagers themselves in September 1987. This simple system which is protected by metal fences consists of three main parts, pump house, vertical sand filter and water tank. The pumped water from underground flows into the upper part of the sand filter, through the sand, and out the water tank which is connected to the bottom of vertical filter. And the simple plastic-bottle chlorinator was installed in the water tank for chlorination. The water quality was remarkably improved after completion of construction. The total bacterial count was not detected from the tap water in households distributed by this simple piped water supply system. The construction cost of this system which was connected 34 households in San-Buk Village, was 4,851,000 won (approximately 6,020 U.S. dollars : 1$=805.8 won) in 1987,77% of expenses was supported by the Community Development Foundation in Korea. This case study for simple piped water supply projects will be applicable to other programme for improvement of water supply system in rural areas of Korea, and other developing countries.

  • PDF

Characteristics of Radon Reduction of Small-scale Water Supply System (소규모수도시설 지하수의 라돈저감 특성)

  • Cho, Byong-Wook
    • The Journal of Engineering Geology
    • /
    • v.29 no.1
    • /
    • pp.37-50
    • /
    • 2019
  • It is possible that radon removal in groundwater of small-scale water supply system (SWSS) is caused by atmospheric storage and aeration facilities installed in the water tank. Radon removal rates at water tank and tap of the 32 SWSS during summer season ranged from -69.3% to 62.7% (average 25.7%) and from -64.3% to 83.1% (average 30.3%) while those of 16 SWSS during autumn season ranged from 21.3% to 78.0% (average 42.8%) and from 17.7% to 66.9% (average 44.8%). The reason of higher radon removal rate in the autumn season compared with the summer season is due to higher atmospheric storage effect by lower groundwater use rate. The radon removal rates at the water tank from 12 SWSS were 47.4~94.0% (average 78.9%), in which the removal rates at the atmospheric storage are also included. Atmospheric storage and aeration can be used to reduce radon concentration in SWSS groundwater. For more efficient use of radon reduction, further studies are necessary to assess the radon removal rate considering variation conditions of radon concentration in groundwater, size and forms of water tank, change in groundwater usage rate, aeration capacity and ventilation facilities.

Zeolite Filtration for Ammonium Nitrogen Removal in Drinking Water Treatment (정수처리에서 암모니아성질소 제거를 위한 제올라이트 여과)

  • 김우항;김충환
    • Journal of Environmental Science International
    • /
    • v.12 no.3
    • /
    • pp.281-286
    • /
    • 2003
  • This study was conducted to evaluate the feasibility of ammonia removal by zeolite adsorption in drinking water treatment. In generally, drinking water treatment process is conducted coagulation/flocculation, sedimentation, sand filtration and disinfection. We tested feasibility with two method, one is powdered zeolite dosing to coagulation tank and the other is to substitute granular zeolite for sand of sand filter. In powdered zeolite test, raw water is used tap water with putting of 2 mg/l of NH$_4$$\^$+/-N. Filtration of granular zeolite was conducted with 80 cm of effective column high and 120 m/d of flow rate. At above 100 mg/1 of zeolite dosage, ammonia concentration was decreased below 0.5 mg/l of NH$_4$$\^$+/-N in powdered zeolite test. But, turbidity was increased to 30 NTU by powdered zeolite dosage. That turbidity was scarcely decreased in generally coagulant using condition in drinking water treatment. In granular zeolite test, ammonia was not detected in treated water until 8 days. This result suggest that using of granular zeolite in sand filter could be removal ammonia in winter. But we need regeneration at zeolite filtration for ammonia removal. So, it is to make clear that zeolite regeneration ability was compared KCl with NaCl. The result reveal that KCl was more excellent than NaCl. Optimum regeneration concentration of KCl was revealed 100 mM. Regeneration efficient was not increased at pH range 10∼12.5.

Groundwater Contamination by Cation, Anion and Pesticides (지하수중 음이온, 양이온, 및 금속의 함량)

  • 김형석;정세영;최중명
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.2
    • /
    • pp.111-128
    • /
    • 1992
  • According to the increase of population and industrialization, the quality of our drinking water are becoming worse by the contamination of resources, production of THM and other halogenated hydrocarbons during the purifying process, the problem of corroded water supplying pipeline, and the water reservoir tanks, Many people choose groundwater to drink instead of city tap water, but sometimes we get report about groundwater contamination by wastes, swage, septic tank, etc. It is reported that in U. S. over 20% of population are drinking groundwater, but U. S EPA reported the groundwater contamination by pesticides, herbicides, fungicides, fertilizer, and various chemical substances. Craun, et at announced the groundwater contamination by bacteria which are related with poor installation of septic tank. Johnson and Kross mentioned aboutmethemoglobinemia by NO3-N originated from human and animal feces, organic chemicals, and fertilizer, and as the results the infant mortality could be risen. Some scientist also reported the high concentration of metals in groundwaters and some cation and anions, and volatile organic compou nds. Authors investigated 80 groundwaters in urban, agricultural, and industrial area during last 3 month(June - August) to check any drinking water quality parameters are exceeding the standards. The results were as follow. 1, The average value of ammonia nitrate were within the standard, but 11.76% of urban area were exceeded the 10 rpm standard, in agricultural area 42.3175 were exceeded, and in industrial area 20.2% were exceeded the drinking water standard of 10 ppm. the highest concentration was 29.37 ppd in industrial area. 2. The mean value of metals is not exceeded the standard, but there were some groundwater whose Mn value was 0.424 ppm(standard is 0,3 ppm) in urban area, 0.737 rpm in agricultural area, and 5.188 ppm in industrial area. The highest Zn value was 1.221 ppm (standard is 1.0 ppm)was found in industrial area. 3. The percentage of contamination by general bacteria was 8.82% in urban area, 15.38% in agricultural area, and 15.00% in industrial area. Escherichia coil group was also contaminated by 35.29% in urban area, 30.76% in agricultural area, and 30.00% in industrial area. 4, The pH value was within the standard which means there was no influence by acid or alkali chemicals, nor acid rain Through the above results, all the groundwater should be tested to check the safety for drinking water and should make some alternative methods suitable for drink.

  • PDF

Life cycle greenhouse-gas emissions from urban area with low impact development (LID)

  • Kim, Dongwook;Park, Taehyung;Hyun, Kyounghak;Lee, Woojin
    • Advances in environmental research
    • /
    • v.2 no.4
    • /
    • pp.279-290
    • /
    • 2013
  • In this study, a comprehensive model developed to estimate greenhouse gas (GHG) emissions from urban area with low impact development (LID) and its integrated management practices (IMPs). The model was applied to the actual urban area in Asan Tangjeong district (ATD) as a case study. A rainwater tank (1200 ton) among various LID IMPs generated the highest amount of GHG emissions ($3.77{\times}10^5kgCO_2eq$) and led to the utmost reducing effect ($1.49{\times}10^3kgCO_2eq/year$). In the urban area with LID IMPs, annually $1.95{\times}104kgCO_2eq$ of avoided GHG emissions were generated by a reducing effect (e.g., tap water substitution and vegetation $CO_2$ absorption) for a payback period of 162 years. A sensitivity analysis was carried out to quantitatively evaluate the significance of the factors on the overall GHG emissions in ATD, and suggested to plant alternative vegetation on LID IMPs.

The Performance of Pollutant Removal Using Nonpoint Treatment Filtration Device and Analysis of the Filter Backwashing Effect (여과형 비점오염 처리장치의 오염물질 제거특성 및 역세척 분석)

  • Lee, Jun-ho;Yang, Seung-ho;Bang, Ki-woong
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.5
    • /
    • pp.523-532
    • /
    • 2015
  • Hydrocyclone is widely used in industry, for its simple design, high capacity, low maintenance and low operational cost. The objective of this study is to develop hydrocyclone coagulation and filtration system. The system is made of hydrocyclone ballasted coagulation with polyaluminium chloride silicate (PACS) and upflow filter to treat micro particles in urban storm runoff. Roadside sediment particles (< $200{\mu}m$) was mixed with tap water to make various turbid suspensions to simulate urban storm runoff. The filter cartridge was filled with polyethylene media system and ran 1hr per everyday and total operation time were 8.19hrs and backwashing everyday after end of operation. The operation condition of flowrate was $8.2{\sim}11.9m^3/day$ (mean $10.1m^3/day$) and surface overflow rate (SOR) based on filter surface area was $45.5{\sim}65.9m^3/m^2/day$ (mean $55.7m^3/m^2/day$). The range of PACS dosage concentration was 14.0~31.5 mg/L. As the results of operation, the range of removal efficiency of turbidity, SS were 81.0~95.8% (mean 89.5%) 81.8~99.0% (mean 91.4%), respectively. An increase of filtration basin retention time brought on increased of removal efficiency of turbidity and SS, and increase of SOR brought on decreased of removal efficiency. During the first flush in urban area, storm runoff have an high concentration of SS (200~600 mg/L) and the filtration bed becomes clogged and decreased of removal efficiency. Backwashing begins when the drainage pipe valve at the filtration tank bottom is completely open (backwashing stage 1). Backwashing stage 2 was using air bubbles and water jet washing the media for 5 mins and open the drainage valve. After backwashing stage 1, 2, 61.83~64.04%, 18.53~27.51% of SS loading was discharged from filtration tank, respectively. Discharged SS loading from effluent was 7.12~14.79% and the range of residual SS loading in fliter was 2.26~5.00%. The backwashing effects for turbidity, SS were 89.5%, 91.4%, respectively. The hydrocyclone coagulation and filtration with backwashing system, which came out to solve the problems of the costly exchange filter media, and low efficiency of removing micro particles of filter type nonpoint treatment devices, is considered as an alternative system.

Analyses of Microbiological Contamination in Cultivation and Distrubution Stage of Tomato and Evaluation of Microbial Growth in Tomato Extract (토마토의 생산·유통단계에서 유해미생물 오염 및 추출물에서 미생물 증식)

  • Yun, Hyejeong;Park, Kyeonghun;Ryu, Kyoung-Yul;Kim, Byung Seok
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.2
    • /
    • pp.174-180
    • /
    • 2013
  • This study investigated the microbiological contamination of tomato in cultivation and distribution stage. Growth of Escherichia coli O157:H7 and Listeria monocytogens examined in tomato extracts (0.1, 1.0, and 10.0%) and incubation temperatures (5, 15, 25, and $35^{\circ}C$). In cultivation stage of tomato, total aerobic bacteria were 7.77 log CFU/g in gloves of APC (Agricultural Products Processing Center) worker and Bacillus cereus were 0.33 log CFU/g at nutrient tank, respectively. And Staphylococcus aureus, Salmonella spp., were not detected. After APC stage, total aerobic bacteria were significantly higher compared with before-APC stage. Among of general, pesticide-free and organic produce in tomato were no significant difference in microbial contamination. Coliforms of tomato in small vinyl package were significantly higher when compared to tomato in whole boxes package. There was no significant difference in bacteria count between unwashed tomato and washed tomato using tap water for one minute. The growth of E. coli O157:H7 and L. monocytogens in tomato extracts were decreased significantly as the concentration increased, and the microbial population was reached the lowest point during storage in 10% tomato extracts concentration for 72h at $5^{\circ}C$. However, the population of E. coli O157:H7 and L. monocytogens were gradually increased at 7.33~8.51 and 7.73~8.60 log CFU/ml during storage at $15{\sim}35^{\circ}C$ for 72h, respectively.