• Title/Summary/Keyword: Tall Buildings

Search Result 888, Processing Time 0.023 seconds

Along and across-wind vibration control of shear wall-frame buildings with flexible base by using passive dynamic absorbers

  • Ivan F. Huergo;Hugo Hernandez-Barrios;Roberto Gomez-Martinez
    • Wind and Structures
    • /
    • v.38 no.1
    • /
    • pp.15-42
    • /
    • 2024
  • A flexible-base coupled-two-beam (CTB) discrete model with equivalent tuned mass dampers is used to assess the effect of soil-structure interaction (SSI) and different types of lateral resisting systems on the design of passive dynamic absorbers (PDAs) under the action of along-wind and across-wind loads due to vortex shedding. A total of five different PDAs are considered in this study: (1) tuned mass damper (TMD), (2) circular tuned sloshing damper (C-TSD), (3) rectangular tuned sloshing damper (R-TSD), (4) two-way liquid damper (TWLD) and (5) pendulum tuned mass damper (PTMD). By modifying the non-dimensional lateral stiffness ratio, the CTB model can consider lateral deformations varying from those of a flexural cantilever beam to those of a shear cantilever beam. The Monte Carlo simulation method was used to generate along-wind and across-wind loads correlated along the height of a real shear wall-frame building, which has similar fundamental periods of vibration and different modes of lateral deformation in the xz and yz planes, respectively. Ambient vibration tests were conducted on the building to identify its real lateral behavior and thus choose the most suitable parameters for the CTB model. Both alongwind and across-wind responses of the 144-meter-tall building were computed considering four soil types (hard rock, dense soil, stiff soil and soft soil) and a single PDA on its top, that is, 96 time-history analyses were carried out to assess the effect of SSI and lateral resisting system on the PDAs design. Based on the parametric analyses, the response significantly increases as the soil flexibility increases for both type of lateral wind loads, particularly for flexural-type deformations. The results show a great effectiveness of PDAs in controlling across-wind peak displacements and both along-wind and across-wind RMS accelerations, on the contrary, PDAs were ineffective in controlling along-wind peak displacements on all soil types and different kind of lateral deformation. Generally speaking, the maximum possible value of the PDA mass efficiency index increases as the soil flexibility increases, on the contrary, it decreases as the non-dimensional lateral stiffness ratio of the building increases; therefore, there is a significant increase of the vibration control effectiveness of PDAs for lateral flexural-type deformations on soft soils.

An Experimental Study of Fire Risk Characteristic by Extended Balcony of High-Rise Apartments in Fire (고층아파트 화재시 발코니 확장에 따른 화재 위험성에 관한 실험 연구)

  • Kim, Woo-Suk;Kim, Wha-Jung;Lee, Gwang-Won;Lee, Ji-Hee
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.2
    • /
    • pp.65-71
    • /
    • 2012
  • Changes in the styles of communities are leading of increases in the number of high-rise apartments and commercial-apartment structures. Tall high-rise structures, while presenting unique economies of scale and cost effectiveness, tend to be highly engineered and complex structures. In the event of a fire, this complexity in design also results in a complexity in the behavior of fire propagation and control. High-rise structures are among the most potentially dangerous due to the high population density in the building, and the inherent limitations on evacuation and on fire control services. One of the most critical points of fire propagation is the movement of fire through the outer wall structures. Controlling such propagation is essential in controlling the spread of the fire throughout the building itself, as well as controlling the potential for its spread to adjacent buildings. In this study, we will be examining the potential for fire control design and effects mitigation using a 1/4.5 scale model. The primary focus of the study will be the effects of extended balconies into the structure of high-rise apartments. The authors will also consider the effectiveness of reduced-scale model tests.

Practical Design Method for Coupling Beams of Tall Buildings with Dual Frame System (이중골조형식 고층건물 커플링보의 실용설계)

  • Yoon, Tae-Ho;Kim, Jin-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.525-532
    • /
    • 2014
  • In this study, practical design method of coupling beams is proposed. The member forces varies according to the location of the members and the members at 25%~40% of building height shows large member forces. The 100mm increase of wall thickness causes 3~4% variation of member forces and the 100MPa increase of concrete strength decrease approximately 3% of member forces. The required strength of coupling beams is twice the resistant strength and 80% reduction of coupling beam stiffness is necessary to fulfill the design criteria. The stiffness reduction of coupling beams is not necessary over the entire stories and the strength reduction range can be estimated considering design requirements.

A Study on the POE (Post Occupancy Evaluation) according to the Residential Environment of Mixed-use Apartment Complexes In Seoul

  • Ha, Man Joon
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.2
    • /
    • pp.197-212
    • /
    • 2020
  • In this study, POE(Post Occupancy Evaluation) evaluation indexes were selected into six categories through the consideration of theories and prior research. Therefore, qualitative supply can be achieved through POE according to the aspect of residential environment after the quantitative supply of mixed-use apartment complex by the population concentration in Seoul due to industrialization and urbanization. As the evaluation elements, detailed survey contents were selected for livability, convenience, comfort, safety, economy, and sociality. Based on the survey contents, six elements were evaluated and analyzed using Data coding and Likert scale after surveying 12 complexes (Urban areas and non-urban areas) in Seoul. As a result of the study, six categories selected as the POE showed that importance of quality of life and safety was developed in high recognition according to high satisfaction with convenience and safety. Sociality showed the lowest satisfaction in the following order : livability, comfort, economy and sociality. Residents' sense of community, interaction with neighborhood, etc., showed low satisfaction, and it seems that it is necessary to improve and supplement the system for the development of mixed-use apartment complex in the future. The detailed characteristics of livability showed high satisfaction of the living room, the front door and the main room which are main uses of housing, and low satisfaction in storage size. The analysis of convenience is that convenient public transportation was the highest, and educational environment and additional facilities were the lowest, showing the advantages and disadvantages of location characteristics. As a result of the analysis of comfort, satisfaction with the landscape area was low and it seems that green space is needed for the development of mixed-use apartment complex in the future. Lastly, regarding the safety, the satisfaction of the access control, the location of security office, etc. were high, however separation of circulation was low. Therefore, it is necessary to clearly separate the circulation between the residence and other facilities in the mixed-use apartment complex.

Experimental Test on the Effect of Onsite Welding of Steel Plates for a Joint Between Concrete Columns and a Steel Belt Truss

  • Shim, Hak Bo;Yun, Da Yo;Park, Hyo Seon
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.2
    • /
    • pp.155-166
    • /
    • 2020
  • To connect exterior reinforced concrete (RC) columns with the steel belt truss, the gusset plates are welded to the steel plates embedded in the RC column. Then, the concrete around an embedded plate is very likely to be damaged by the heat input from a long-time (6 to 48 hours) welding of the embedded and gusset plates at a joint between RC columns and steel belt truss. However, very few studies have assessed the concrete damage caused by the welding heat between embedded and gusset plates, and no clear onsite solution has been found. In this paper, experimental tests have been carried out on 4 full-scale specimen to analyze the effect of long-time (about 6 hours) onsite welding (1-side welding and 3-side welding) between a gusset plate and an embedded plate in high strength concrete with compressive strength of 55 MPa and 80 MPa on RC columns. The effect of the long-time welding heat of embedded and gusset plates, which are used in real high-rise building construction sites, on concrete is analyzed in terms of the following three items: 1) temperature distribution, 2) pattern and characteristics of cracks, and 3) effect of the cracks on the compressive strength of RC column. Based on the experimental results, even though the heat input up to about 150? from the long-time onsite welding on the high-strength concrete column for the joint could result in concrete cracks in a radial form, it is found that the welding cracks have no effect on the axial stiffness and strength of the concrete column.

Structural Performance of 800 MPa High-Strength Steel Members and Application to Highrise and Mega Building Structures

  • Lee, Cheol-Ho
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.3
    • /
    • pp.249-259
    • /
    • 2017
  • The use of high-strength steels in construction of highrise and mega building structures can bring about many technological advantages from fabrication to erection. However, key design criteria such as local and lateral stability in current steel design specifications were developed based on tests of ordinary steels which have stress-strain characteristics very different from that of high strength steels. A series of tests on 800 MPa tensile strength steel (HSA800) members are summarized in this paper which were conducted to investigate the appropriateness of extrapolating current ordinary-steel based design criteria to high strength steels. 800 MPa I-shape beam specimens designed according to flange local buckling (FLB) criteria of the AISC Specification developed a sufficient strength for elastic design and a marginal rotation capacity for plastic design. It is shown that, without introducing distinct and significant yield plateau to the stress-strain property of high-strength steel, it is inherently difficult to achieve a high rotation capacity even if all the current stability limits are met. 800 MPa I-shape beam specimens with both low and high warping rigidity exhibited sufficient lateral torsional buckling (LTB) strength. HSA800 short-column specimens with various edge restraint exhibited sufficient local buckling strength under uniform compression and generally outperformed ordinary steel specimens. The experimental P-M strength was much higher than the AISC nominal P-M strength. The measured residual stresses indicated that the impact of residual stress on inelastic buckling of high-strength steel is less. Cyclic seismic test results showed that HSA800 members have the potential to be used as non-ductile members or members with limited ductility demand in seismic load resisting systems. Finally, recent applications of 800 MPa high strength steel to highrise and mega building structures in Korea are briefly presented.

The multi-axial strength performance of composited structural B-C-W members subjected to shear forces

  • Zhu, Limeng;Zhang, Chunwei;Guan, Xiaoming;Uy, Brian;Sun, Li;Wang, Baolin
    • Steel and Composite Structures
    • /
    • v.27 no.1
    • /
    • pp.75-87
    • /
    • 2018
  • This paper presents a new method to compute the shear strength of composited structural B-C-W members. These B-C-W members, defined as concrete-filled steel box beams, columns and shear walls, consist of a slender rectangular steel plate box filled with concrete and inserted steel plates connecting the two long-side steel plates. These structural elements are intended to be used in structural members of super-tall buildings and nuclear safety-related structures. The concrete confined by the steel plate acts to be in a multi-axial stressed state: therefore, its shear strength was calculated on the basis of a concrete's failure criterion model. The shear strength of the steel plates on the long sides of the structural element was computed using the von Mises plastic strength theory without taking into account the buckling of the steel plate. The spacing and strength of the inserted plates to induce plate yielding before buckling was determined using elastic plate theory. Therefore, a predictive method to compute the shear strength of composited structural B-C-W members without considering the shear span ratio was obtained. A coefficient considering the influence of the shear span ratio was introduced into the formula to compute the anti-lateral bearing capacity of composited structural B-C-W members. Comparisons were made between the numerical results and the test results along with this method to predict the anti-lateral bearing capacity of concrete-filled steel box walls. Nonlinear static analysis of concrete-filled steel box walls was also conducted by using ABAQUS and the results agreed well with the experimental data.

Field Measurement and Modal Identification of Various Structures for Structural Health Monitoring

  • Yoshida, Akihiko;Tamura, Yukio
    • International Journal of High-Rise Buildings
    • /
    • v.4 no.1
    • /
    • pp.9-25
    • /
    • 2015
  • Field measurements of various structures have been conducted for many purposes. Measurement data obtained by field measurement is very useful to determine vibration characteristics including dynamic characteristics such as the damping ratio, natural frequency, and mode shape of a structure. In addition, results of field measurements and modal identification can be used for modal updating of FEM analysis, for checking the efficiency of damping devices and so on. This paper shows some examples of field measurements and modal identification for structural health monitoring. As the first example, changes of dynamic characteristics of a 15-story office building in four construction stages from the foundation stage to completion are described. The dynamic characteristics of each construction stage were modeled as accurately as possible by FEM, and the stiffness of the main structural frame was evaluated and the FEM results were compared with measurements performed on non-load-bearing elements. Simple FEM modal updating was also applied. As the next example, full-scale measurements were also carried out on a high-rise chimney, and the efficiency of the tuned mass damper was investigated by using two kinds of modal identification techniques. Good correspondence was shown with vibration characteristics obtained by the 2DOF-RD technique and the Frequency Domain Decomposition method. As the last example, the wind-induced response using RTK-GPS and the feasibility of hybrid use of FEM analysis and RTK-GPS for confirming the integrity of structures during strong typhoons were shown. The member stresses obtained by hybrid use of FEM analysis and RTK-GPS were close to the member stresses measured by strain gauges.

A Study on the Beijing hotel's Architectural Characteristics of the Early Reform & Opening times in China - Focusing on the cases of high-rise hotels from 1978 until 1992 - (중국 개혁개방 초기 북경호텔의 건축적 특성에 관한 연구 - 1978년부터 1992년까지의 고층호텔 건축사례를 중심으로 -)

  • Gao, Yong;Kim, Hwan-Sik;Lee, Jeong-Soo
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.2
    • /
    • pp.197-205
    • /
    • 2010
  • This study examines for the processes of making a architectural significant issue of 20 cases form of Beijjng's hotel through analyzing the space composition from early the 1950's to 1992 in China. In the methods of analyzing process, We study the literatures, research reports and architectural drawings including the site survey. We hope to establish the principle in morphological characteristics and space composition of Beijing's high-rise hotels through analyzing the plan of these hotels. Finally, We find out the principles after researching. Firstly, Beijing's hotels in China faced on the being difficulties through the process of national development especially in political and economical conditions of country and peoples. Consequently, size of the Beijing's hotel developed with the fact that is complicated from that is single styles focused on the medium-sized one, modernizing popularity and the high-rise hotel buildings appeared plentifully and the form appeared with tall building putting first. Secondly, there are many immanent and interlocking styles in hotel's architectural block plans, many composition styles in big sized hotels, in opposition immanent styles in small sized ones and there are many trend of concourse style in medium sized hotels. To the layout of hotel's room inside of the linear styles are many in big and medium sized hotels.

A Study on the Prediction of the Strength and Axial Strain of High-Strength Concrete Columns Confined by Tie Reinforcement (띠근 보강 고강도 콘크리트 기둥의 강도 및 축변형 특성 산정에 관한 연구)

  • Park, Hoon-Gyu;Jang, Il-Young
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.197-208
    • /
    • 1999
  • The use of high-strength concrete which permits smaller cross sections, reduced dead loads, and longer spans has been getting more popular in tall buildings. However, there has been little research on behavior of high-strength concrete columns laterally reinforced with square ties and subjected to compressive loading. With the addition of transverse reinforcement which lead to triaxial compressive state, ductility behavior of high-strength column member shall be increased. In this study, rational quality and quantity evaluations were made to investigate the ultimate strength and strain ductility by confinement effect of tie reinforced high-strength concrete columns subject to uniaxial loads. Concrete failure theory at the triaxial compressive state and statistical results based on conventional experimental data were applied for this propose. Up to 185 columns, tested under monotonically increasing concentric loading, were evaluated in terms of strength and strain ductility. Analytical results show that confinement stress, maximum compressive strength, and increase of strain equations were developed with the consideration of concrete strength, yield strength, spacing, volumetric ratio, and configurations of tie reinforcement.