• 제목/요약/키워드: Taguchi

검색결과 1,104건 처리시간 0.024초

Micro-Spot Atmospheric Pressure Plasma Production for the Biomedical Applications

  • Hirata, T.;Tsutsui, C.;Yokoi, Y.;Sakatani, Y.;Mori, A.;Horii, A.;Yamamoto, T.;Taguchi, A.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.44-45
    • /
    • 2010
  • We are currently conducting studies on culturing and biocompatibility assessment of various cells such as neural stem cells and induced pluripotent stem cells(IPS cells) on carbon nanotube (CNT), on nerve regeneration electrodes, and on silicon wafers with a focus on developing nerve integrated CNT based bio devices for interfacing with living organisms, in order to develop brain-machine interfaces (BMI). In addition, we are carried out the chemical modification of carbon nanotube (mainly SWCNTs)-based bio-nanosensors by the plasma ion irradiation (plasma activation) method, and provide a characteristic evaluation of a bio-nanosensor using bovine serum albumin (BSA)/anti-BSA binding and oligonucleotide hybridization. On the other hand, the researches in the case of "novel plasma" have been widely conducted in the fields of chemistry, solid physics, and nanomaterial science. From the above-mentioned background, we are conducting basic experiments on direct irradiation of body tissues and cells using a micro-spot atmospheric pressure plasma source. The device is a coaxial structure having a tungsten wire installed inside a glass capillary, and a grounded ring electrode wrapped on the outside. The conditions of plasma generation are as follows: applied voltage: 5-9 kV, frequency: 1-3 kHz, helium (He) gas flow: 1-1.5 L/min, and plasma irradiation time: 1-300 sec. The experiment was conducted by preparing a culture medium containing mouse fibroblasts (NIH3T3) on a culture dish. A culture dish irradiated with plasma was introduced into a $CO_2$-incubator. The small animals used in the experiment involving plasma irradiation into living tissue were rat, rabbit, and pick and are deeply anesthetized with the gas anesthesia. According to the dependency of cell numbers against the plasma irradiation time, when only He gas was flowed, the growth of cells was inhibited as the floatation of cells caused by gas agitation inside the culture was promoted. On the other hand, there was no floatation of cells and healthy growth was observed when plasma was irradiated. Furthermore, in an experiment testing the effects of plasma irradiation on rats that were artificially given burn wounds, no evidence of electric shock injuries was found in the irradiated areas. In fact, the observed evidence of healing and improvements of the burn wounds suggested the presence of healing effects due to the growth factors in the tissues. Therefore, it appears that the interaction due to ion/radicalcollisions causes a substantial effect on the proliferation of growth factors such as epidermal growth factor (EGF), nerve growth factor (NGF), and transforming growth factor (TGF) that are present in the cells.

  • PDF

R.F. Sputtering 방법에 의한 상변화형 광디스크의 $(ZnS)_{1-x}(SiO_2)_x$ 보호막 형성에 미치는 전극거리의 영향 (The Effects of Electrode Distance on the Formation of $(ZnS)_{1-x}(SiO_2)_x$ Protective Films in Phase Change Optical Disk by R.F. Sputtering Method)

  • 이준호;김도훈
    • 한국재료학회지
    • /
    • 제9권12호
    • /
    • pp.1245-1251
    • /
    • 1999
  • 상변화형 광디스크는 직접 반복기록에 의한 고속기록, 고밀도화가 가능하고 높은 전송속도, 재생신호의 C/N (carrier to noise) 비가 좋은 장점을 가지고 있으나 반복되는 열에너지에 의한 디스크의 변형과 소거도의 저하, 기록 반복성의 저하가 문제가 된다. 이러한 반복성의 저하를 개선하기 위해 적절한 디스크의 구조와 기록막의 상하부에 유전체 보호막인 ZnS-$SiO_2$ 박막층을 삽입하였다. 박막 제조시 많은 실험변수의 제어를 위해 다꾸찌 방법을 통하여 타겟 R.F. Power 200W, 기판 R.F. Power 20W, 아르곤 압력 4mTorr, 전극거리 6cm의 최적조건을 얻을수 있었다. TEM과 XRD분석 결과, 전극거리가 가까워질수록 높은 증착속도로 인하여 미세한 조직구조를 가지고 있으며, 일정거리 이상 가까워지면 막의 morphology에 나쁜 영향을 끼침을 알 수 있었다. 이러한 막의 morphology의 영향으로 투과율이 감소하는 것을 확인할 수 있었다. AFM과 SEM분석에서는 전극거리가 가까워질수록 높은 증착속도로 인하여 morphology에 나쁜 영향을 끼치고 있음을 확인할 수 있었다. 최적조건에서 증착한 박막은 우수한 morphology를 가진 초미세구조의 치밀하고 결함이 없는 박막이었다. 이 박막은 상변화형 광디스크에서 열적 변형을 억제하고, 열전도를 감소시켜 우수한 유전체 보호피막의 역할을 할 수 있다. 그리고, 전극거리가 ZnS결정립의 크기와 증착속도, morphology에 미치는 영향에 대해 고찰하였다.

  • PDF

진료의 질관리에 대한 시론 -장애와 접근- (Quality Improvement in Patient Care Services : Obstacles and Approaches)

  • 한달선
    • 보건행정학회지
    • /
    • 제2권2호
    • /
    • pp.112-130
    • /
    • 1992
  • Patient care services are provided to individual patients in response to their health needs produced by illnesses or injuries. The services are often addressed to very serious conditions, and also they constitute the most expensive component of health care services. Therefore, the importance of quality is emphasized, but there are many indications that patient care quality is far from a satisfactory state in most of the countries. Based upon this observation, it is attempted to examine obstacles and approaches to quality improvement in patient care services. In doing so, following Taguchi's(1986) definition of product quality, quality of patient care services is conceived of as better when the less is the sociental loss attributalbe to variability of intended function and harmful side effects they emhibit after being delivered. Some distinguishing features of medical care sector pose difficulties in implementing effective quality improvement programs in patient care services. Nevertheless, newly proposed method of quality management, based on industrial quality management approach, seems to have a great deal of potential to effectively cope with such difficulties. This method, unlike the traditional approach to quality assurance, focuses on total organisational processes, not individuals, as the obproach to quality assurance, focuses on total organizational processes, not individuals, as the objects of quality improvement; variation, not comparison with standards, in quality measurement; and continuous improvement, not removing only bad quality care, as an ideal. Prerequisite to a successful use of any quality mangement method is motivating providers to improve quality. Conceivable approaches for such motivation are self-regulation, external controls and promotion of competition. Since these approaches are not mutually exclusive, they may be employed in an appropriate combination. In Korea, medical care providers are now functioning under the circumstances where they have little reason for making efforts to improve quality of their services. Once these circumstantial conditions are changed to exert pressures on providers to improve quality, the use of adequate quality management method becomes an issue. In this connection, much attention shoould be directed to the newly proposed method described above. In all these efforts for improving quality of patient care services, health insurance would be able to play a pivotal role. Poviders of medical care, buth indiciduals and organizations, are usually very responsive to the measures that affect their financing, and thus health insurance can be a strong instrument for motivationg providers to improve quality. Also, the insurance continuously acquires data on patient care, which could be processed to produce information required to effective quality control.

  • PDF

Performance Evaluation of Hypersonic Turbojet Experimental Aircraft Using Integrated Numerical Simulation with Pre-cooled Turbojet Engine

  • Miyamoto, Hidemasa;Matsuo, Akiko;Kojima, Takayuki;Taguchi, Hideyuki
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.671-679
    • /
    • 2008
  • The effect of Pre-cooled Turbojet Engine installation and nozzle exhaust jet on Hypersonic Turbojet EXperimental aircraft(HYTEX aircraft) were investigated by three-dimensional numerical analyses to obtain aerodynamic characteristics of the aircraft during its in-flight condition. First, simulations of wind tunnel experiment using small scale model of the aircraft with and without the rectangular duct reproducing engine was performed at M=5.1 condition in order to validate the calculation code. Here, good agreements with experimental data were obtained regarding centerline wall pressures on the aircraft and aerodynamic coefficients of forces and moments acting on the aircraft. Next, full scale integrated analysis of the aircraft and the engine were conducted for flight Mach numbers of M=5.0, 4.0, 3.5, 3.0, and 2.0. Increasing the angle of attack $\alpha$ of the aircraft in M=5.0 flight increased the mass flow rate of the air captured at the intake due to pre-compression effect of the nose shockwave, also increasing the thrust obtained at the engine plug nozzle. Sufficient thrust for acceleration were obtained at $\alpha=3$ and 5 degrees. Increase of flight Mach number at $\alpha=0$ degrees resulted in decrease of mass flow rate captured at the engine intake, and thus decrease in thrust at the nozzle. The thrust was sufficient for acceleration at M=3.5 and lower cases. Lift force on the aircraft was increased by the integration of engine on the aircraft for all varying angles of attack or flight Mach numbers. However, the slope of lift increase when increasing flight Mach number showed decrease as flight Mach number reach to M=5.0, due to the separation shockwave at the upper surface of the aircraft. Pitch moment of the aircraft was not affected by the installation of the engines for all angles of attack at M=5.0 condition. In low Mach number cases at $\alpha=0$ degrees, installation of the engines increased the pitch moment compared to no engine configuration. Installation of the engines increased the frictional drag on the aircraft, and its percentage to the total drag ranged between 30-50% for varying angle of attack in M=5.0 flight.

  • PDF