• 제목/요약/키워드: Table tilting

검색결과 38건 처리시간 0.022초

공작기계 구조물의 전산 모델링 자동화 (FEM Modeling Automation of Machine Tools Structure)

  • 이찬홍;하태호;이재학
    • 한국정밀공학회지
    • /
    • 제29권10호
    • /
    • pp.1043-1049
    • /
    • 2012
  • The FEM analysis of machine tools is the general analysis process to evaluate machine performance in the industry for a long time. Despite advances in FEM software, because of difficult simplicity of CAD drawing, little experience of joints stiffness modeling and troublesome manual contact area divide for bindings, the industry designers think the FEM analysis is still an area of FEM analysis expert. In this paper, the automation of modeling process with simplicity of drawing, modeling of joints and contact area divide is aimed at easy FEM analysis to enlarge utilization of a virtual machine tools. In order to verify the effects of modeling automation, a slant bed type model with tilting table is analyzed. The results show FEM modeling automation method only needed 45 minutes to complete the whole modeling process, while manual modeling method requires almost one month with 8200 calculations for coordinate transformations and stiffness data input.

5축 공작기계의 고강성 구조설계에 관한 연구 (Study on Structure Design of High-Stiffness for 5 - Axis Machining Center)

  • 홍종필;공병채;최성대;최현진;이달식
    • 한국기계가공학회지
    • /
    • 제10권5호
    • /
    • pp.7-12
    • /
    • 2011
  • This study covers the optimum design of the 5-axis machine tool. In addition, the intelligent control secures structural stability through the optimum design of the structure of the 5-axis machine center, main spindle, and the tilting index table. The big requirement, like above, ultimately leads to speed-up operation. And this is inevitable to understand the vibration phenomenon and its related mechanical phenomenon in terms of productivity and its accuracy. In general, the productivity is correlated with the operation speed and it has become bigger by its vibration scale and the operation speed so far. Vibration phenomenon and its heat-transformation of the machine is naturally occurred during the operation. If these entire machinery phenomenons are interpreted through the constructive understanding and the interpretation of the naturally produced vibration and heat-transformation, it would be very useful to improve the rapidity and its stability of the machine operation indeed. In this dissertation, the problems of structure through heating, stability, dynamic aspect and safety about intelligent 5-wheel machine tool are discovered to examine. All these discoveries are applied to the structure in order to enhance the density of it. It aims to improve the stability.

공구 끝의 일정한 절삭속도를 위한 5축 NC 가공 데이터의 이송속도 산출 (Calculating the Feedrate of 5-Axis NC Machining Data for the Constant Cutting Speed at a CL-point)

  • 이철수;이제필
    • 한국CDE학회논문집
    • /
    • 제6권2호
    • /
    • pp.69-77
    • /
    • 2001
  • This paper describes a method of calculating the feedrate for the constant cutting speed at a CL-point in 5-axis machining. Unlike 3-axis machining, 5-axis machining has the flexibility of the tool motions due to two rotation axes. But the feedrate at joint space differs from the feedrate at a tool tip(the CL-point) of the 3D Euclidean space for the tool motions. The proposed algorithm adjusts the feedrate based on 5-axis NC data, the kinematics of a machine, and the tool length. The following calculations is processed for each NC block to generate the new feedrate; 1) calculating the moving distance at the CL-point, 2) calculating the moving time by the given feedrate, 3) calculating the feedrate of each axis, 4) getting the new feedrate. The proposed algorithm was applied to a 5-axis machine which had a tilting spindle and a rotary table. Totally, the result of the algorithm reduced the machining time and smoothed the cutting-load by the constant cutting speed at the CL-point.

  • PDF

두부하위$(-6^{\circ})$로의 체위변동이 말초혈류에 미치는 영향 (Effects of Head-down Tilt $(-6^{\circ})$ on Peripheral Blood Flow in Dogs)

  • 채의업;양선영;배재훈;송대규
    • The Korean Journal of Physiology
    • /
    • 제24권1호
    • /
    • pp.51-65
    • /
    • 1990
  • The purpose of the present study was to examine the hemodynamic responses, especially in arterial and skin blood flows, in conjunction with the changes of plasma catecholamine levels as an indirect marker of adrenergic tone during the early stage of head-down tilt (HDT), and to evaluate the early physiological regulatory mechanism in simulated weightlessness. Ten mongrel dogs, weighing8\;{\sim}\;14\;kg, were intravenously anesthetized with nembutal, and postural changes were performed by using the tilting table. The postural changes were performed in the following order: supine, prone, HDT $(-6^{\circ}C)$ and lastly recovery prone position. The duration of each position was 30 minutes. The measurements were made before, during and after each postural change. The arterial blood flow $({\.{Q}})$ at the left common carotid and right brachial arteries was measured by the electromagnetic flowmeter. Blood pressure (BP) was directly measured by pressure transducer in the left brachial artery. To evaluate the peripheral blood flow, skin blood flow $({\.{Q}})$ was calculated by the percent changes of photoelectric pulse amplitude on the forepaw, and skin temperature was recorded. The peripheral vascular resistance (PR) was calculated by dividing respective mean BP values by ${\.{Q}}$ of both sides of common carotid and brachial arteries. Heart rate (HR), respiratory rate (f) and PH, $Po_{2},\;Pco_{2}$ and hematocrit of arterial and venous blood were also measured. The concentration of plasma epinephrine and norepinephrine was measured by radioenzymatic method. The results are summarized as follows: Tilting to head-down position from prone position, HR was initially increased (p<0.05) and BP was not significantly changed. While ${\.{Q}}$ of the common carotid artery was decreased (p<0.05) and PR through the head was increased, ${\.{Q}}$ of the brachial artery was increased (p<0.05) and PR through forelimbs was decreased. ${\.{Q}}$ of the forepaw was initially increased (p<0.05) and then slightly decreased, on the whole revealing an increasing trend. Plasma norepinephrine was slightly decreased and the epinephrine was slightly increased. f was increased and arterial pH was increased (p<0.05). In conclusion, the central blood pooling during HDT shows an increased HR via Bainbridge reflex and an increased ${\.{Q}}$ of the forepaw and brachial ${\.{Q}}$, due to decreased PR which may be originated from the depressor reflex of cardiopulmonary baroreceptors. It is suggested that the blood flow to the brain was adequately regulated throughout HDT $(-6^{\circ}C)$ in spite of central blood pooling. And it is apparent that the changes of plasma norepinephrine level are inversely proportional to those of ${\.{Q}}$ of the forepaw, and the changes of epinephrine level are paralleled with those of the brachial ${\.{Q}}$.

  • PDF

냉증과 기립성 저혈압의 연관성에 관한 연구 (A study of association between Cold Hypersensitivity and Orthostatic Hypotension(OH))

  • 장경호;송화숙;이동규;김세현;김상우
    • 대한한방체열의학회지
    • /
    • 제2권1호
    • /
    • pp.29-34
    • /
    • 2003
  • Purpose The purpose of this study was to verify the association between Cold Hypersensitivity and Orthostatic Hypotension(OH). Method This study was carried out on 39 women who visited outpatient department of Dept. of Gynecology. Bundang CHA oriental Hospital. College of Medicine. Pochun CHA univ. from December 2001 to November 2002. We divided them into two groups (Orthostatic Hypotension Group 24, Normal BP Group 15) and investigated general characteristics, weight, height, past history. family history through out the patient's note. OH was assessed 1 minute after the patients rose from a supine position by using tilting table. For the diagnosis of cold hypersensitivity, thermographic measurements were performed on two pairs of areas(palm-upper arm and back of hand-upper arm. And for that of the feet, other two pairs of areas(anterior thigh-top of the feet and posterior thigh-heel). And then by which verify the association between Cold Hypersensitivity and Orthostatic Hypotension(OH) Results As a results, 16 out of 24 patients, the OH group had cold hypersensitivity and 4 out of 15 Patients the normal BP group had cold hypersensitivity. It means that there was association between Cold Hypersensitivity and Orthostatic Hypotension(OH). Conclusion Above these results, we can reach the conclusion that OH is considered one of the causes of cold hypersensitivity.

  • PDF

전력전자 기술을 응용한 의료장비 개발 사례 (Example Development of Medical Equipment Applying Power Electronics Technique)

  • 고종선;이태훈;김영일;김규겸;박병림
    • 전력전자학회논문지
    • /
    • 제7권6호
    • /
    • pp.524-530
    • /
    • 2002
  • 일상 생활에서 반사적인 자세 조절은 정전기관, 시각, 고유수용체 등의 감수체에 의한 구심성 신호가 정전 신경핵에 전달되어 안구운동이나 골격근의 수축을 유발하여 이루어진다. 자세조절기능의 부조화는 오심, 구토, 현기증 등을 초래하여 삶의 의욕을 상실하게 만든다. 본 연구의 목적은 정전기관의 반규관과 이석기관을 선별적으로 자극하기 위한 탈수직축 회전자극 시스템과 수평, 수직, 3D 환경에서 시각자극을 할 수 있는 시운동자극시스템을 개발하여 인간의 자세조절 기능을 평가 하는데 있다. 탈수직축 회전자극 시스템은 편안한 의자와 DC 서보모터로 구동되는 기울임 테이블로 구성되고 PMSM에 의해 제어된다. 그리고 속도 궤환 루프와 위치 궤환 루프를 포함하는 이중 피드백 루프가 서보 제어되는 회전자극시스템에 적용된다. HMD를 이용하여 수평, 수직, 3D 시각자극패턴을 구현 하였고 OKN 자극을 위한 무선시스템과 전기안진 기록계를 이용하여 안구운동을 기록하였다. 이득, 위상, 대칭성은 정전 자극과 시각 자극에 의해 유발되는 안구운동의 분석으로부터 얻어진다.

전력전자 기술을 응용한 의료장비 개발 사례 (Example Development of Medical equipment applying Power Electronics Technique)

  • 고종선;이태훈;김영일;김규겸;박병림;김민선
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.661-664
    • /
    • 2002
  • A control of the body posture and movement is maintained by the vestibular system, vision, and proprioceptors. Afferent signals from those receptors are transmitted to the vestibular nuclear complex, and the efferent signals from the vestibular nuclear complex control the eye movement. The postural disturbance caused by loss of the vestibular function results in nausea, vomiting, vertigo and loss of craving for life. The purpose of this study is to develop a off-vertical rotatory system for evaluating the function of semicircular canals and otolith organs, selectively, and visual stimulation system for stimulation with horizontal, vertical and 3D patterns. The Off-vertical axis rotator which stimulates semicircular canals and otolith organs selectively is composed of a comportable chair, a DC servo-motor with reducer and a tilting table controlled by PMSM. And a double feedback loop system containing a velocity feedback loop and a position feedback loop is applied to the servo controlled rotatory chair system. Horizontal, vertical, and 3D patterns of the visual stimulation for applying head mounted display are developed. And wireless portable systems for optokinetic stimulation and recording system of the eye movement is also constructed. The Gain, phase, and symmetry is obtained from analysis of the eye movement induced by vestibular and visual stimulation. Detailed data were described.

  • PDF

방사선촬영 보조기구를 이용한 어린이 흉부 엑스선 검사에 관한 연구 (A Study on Chest X-ray Using Ancillary Device for Child Radiography)

  • 이도병;이소미;최현우;김종기;이종민
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권1호
    • /
    • pp.48-54
    • /
    • 2018
  • In this study, We developed a Ancillary device for child radiography for X-ray of children under 5 years old and verified its effectiveness. Chest X-rays of children younger than 5 years of age were performed by Supine method at the position of Table detector, Short - Source to Image Receptor Distance(SID). Existing Supine and Short -SID imaging methods cause many problems, such as errors in image reading and excessive radiation exposure dose to patients, but the use of an Ancillary device for child radiography(ADCR) solves these problems. A total of 160 children were divided into the Upright group using ADCR and Supine group without ADCR. The chest X-ray image was visually evaluated by two radiologists with reference to the European Commission's List of Quality Criteria for Diagnostic Radiographic Images in Pediatrics. The total score of the qualitative evaluation was 5.15% higher in the chest upright method using ADCR than in the chest supine method without ADCR, and the chest upright method score was higher than that of the chest supine method in items 1 to 7. whether infants have deep inspiration or not, 4.87% higher for item 1, whether infants rotate or not and the degree of tilting, 0% higher for the item 2, the reproduction of image from just above apices of lungs to T12/L1, 0% for the item 3, reproduction of the vascular pattern in central 2/3 of the lungs, 6.92% higher for the item 4, reproduction of the trachea and the proximal bronchi, 12.9% higher for the item 5, visually sharp reproduction of the diaphragm and costo-phrenic angles, 10% higher for the item 6, reproduction of the spine and paraspinal structures and visualisation of the retrocardiac lung and the mediastinum, and 3.65% higher for the item 7. Items 2 and 3 showed no statistically significant differences(P > 0.05), and items 1, 4, 5, 6, and 7 showed statistically significant differences(P < 0.05). In conclusion, Upright method using ADCR in pediatric chest X-ray is considered as a good alternative to existing Supine method.