• Title/Summary/Keyword: Table speed

Search Result 541, Processing Time 0.032 seconds

Influence of Operating Condition on Grinding Temperature in High Effect Grinding (고능률 가공에서 연삭 온도에 미치는 연삭 조건의 영향)

  • 김남경;강대민;송지복
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.1
    • /
    • pp.31-39
    • /
    • 1990
  • In this paper, the influence of the table speed, metal removal rate and grinding fluid on long wheel workpiece contact zone at high effect grinding was investigated by theoretical analyses and measuring the temperature, and discussed by the temperature distribution in grinding surface layer. Main results obtained are as follows, 1) Rega.dless of the table speed, the temperature gap of the workpiece(heat influx) is about 6-8 times as high in dry condition as in wet condition. 2) Good grinding condition can be obtained owing to the effect of grinding fluid without any burning defect under the condition of the metal removal rate(1.0mm$^3$/mm.s) in case of wet grinding. 3) When the depth from the surface layer is about 1.25-1.5mm under the condition of the slow table speed, surface temperature goes up higher as the table speed slows down, because long contact time is laked at the surface layer. 4) In case of the same metal removal rate, the lower the table speed becomes, the higher the surface temperature is, because grinding depth has a far more influence on wheel workpiece contact zone than the table speed.

  • PDF

A Study on Characteristics of Dimensional Accuracy using Planning Number of Machining in Machining Center (머시닝센터 평면가공 시 가공횟수에 따른 치수정밀도 특성에 관한 연구)

  • Yang, Yong-Mo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.61-67
    • /
    • 2018
  • The face milling cutter, which is mainly used for the face milling, is used to cut the Carbon steel(SM20C) in the machining center for 5 times and 10 times respectively. This study clarify the dimensional accuracy characteristics according to the number of fine machining varied the condition of cutting depth, table feed speed and spindle speed. Cutting depth is varied 0.05~0.2mm, table feed speed is varied 0.05~0.2mm/min and spindle speed is varied 1500~2500rpm. As a result, the dimensional accuracy was stable 6 times machining with table feed speed 150mm/min and 10 times machining with table speed 100mm/min and cutting depth 0.05mm regardless times of machining.

Approaches for Improving Bloom Filter-Based Set Membership Query

  • Lee, HyunYong;Lee, Byung-Tak
    • Journal of Information Processing Systems
    • /
    • v.15 no.3
    • /
    • pp.550-569
    • /
    • 2019
  • We propose approaches for improving Bloom filter in terms of false positive probability and membership query speed. To reduce the false positive probability, we propose special type of additional Bloom filters that are used to handle false positives caused by the original Bloom filter. Implementing the proposed approach for a routing table lookup, we show that our approach reduces the routing table lookup time by up to 28% compared to the original Bloom filter by handling most false positives within the fast memory. We also introduce an approach for improving the membership query speed. Taking the hash table-like approach while storing only values, the proposed approach shows much faster membership query speed than the original Bloom filter (e.g., 34 times faster with 10 subsets). Even compared to a hash table, our approach reduces the routing table lookup time by up to 58%.

Ranging Algorithm of Underwater Acoustic Wave with Look-up Table (Look-up table을 이용한 수중 음향파 거리 추정 알고리즘)

  • Cheon, Ju-Hyun;Moon, Seung-Hyun;Lee, Ho-Kyoung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.23-29
    • /
    • 2015
  • In this paper, we introduce a underwater ranging algorithm with Look-up Table (LUT) by modifying the existing method which is using the changes of angles of accoustic rays with SSP (Sound Speed Profile). We compare the horizontal distance errors and the calculation times. Our new algorithm exploits Time of Arriva l(ToA) - horizontal distance table based on SSP. This algorithm offers faster calculation speed than the previous one with the slight increase of the distance estimation error.

A Study on the Auto-MTPT Algorithm to Make the Speed-based Current-map of IPMSM for Traction of Inwheel (인휠 구동용 IPMSM의 속도 기반 전류맵 작성을 위한 Auto-MTPT 알고리즘)

  • Park, Gui-Yeol;Park, Jung-Woo;Hwang, Yo-Han;Shin, Duck-Woong;Moon, Chae-Joo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.5
    • /
    • pp.411-417
    • /
    • 2016
  • Theoretical IPMSM control technique is complicated, and reliability is low because of the changing parameters. Further, in case of general look-up table designing method which obtains torque characteristics (according to current and speed) or torque characteristics (according to magnetic flux through the entire control region), obtaining a precise result can be difficult and has the disadvantage taking too much time to establish a current look-up table. In this paper, the new auto maximum torque point tracking (MTPT) algorithm that automatically finds the optimum stator d - q axis electric current reference through the entire speed region is devised; consequently, it could establish a 3D look-up table with torque characteristics according to current and speed. In case of using the devised auto MTPT algorithm, the result value detailed was obtained in comparison with the generalized look-up design technique, and checked to reduce the current look-up table establishment time.

A Performance Improvement Method of PMSM Torque Control Considering DC-link Voltage Variation (DC-link 전압변동을 고려한 PMSM 토크제어의 성능 향상 방법)

  • Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.112-122
    • /
    • 2014
  • This paper proposes a PMSM torque control method considering DC-link voltage variation and friction torque. In general EV/HEV application, two dimensions look-up table(2D-LUT) is used for reference current generation due to its stable and robust torque control performance. Conventionally, this 2D-LUT is established by flux-torque table to overcome the DC-link voltage variation. However, the flux table establishment is more complex than the speed table establishment. Moreover, one flux data reflects several speed conditions in variable DC-link voltage, friction torque cannot be considered by using the flux table. In this paper, speed-torque 2D-LUT is used for current reference generation. With this table, PMSM torque control is well achieved regardless of DC-link voltage variation by the proposed control method. Simulation and experimental results validate improvement of torque control error through friction torque compensation.

Practical MAC address table lookup scheme for gigabit ethernet switch (기가비트 이더넷 스위치에서 빠른 MAC 주소 테이블의 검색 방법)

  • 이승왕;박인철
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.799-802
    • /
    • 1998
  • As we know, gigabit ethernet is a new technology to be substituted for current fast ethernet used widely in local area network. The switch used in gigabit ethernet should deal with frames in giga-bps. To do such a fast switching, we need that serveral processes meet the budgets, such as MAC address table lookup, several giga speed path setup, fast scheduling, and etc. Especially MAC address table lookup has to be processed in the same speed with speed of incoming packets, thus the bottleneck in the process can cause packet loss by the overflow in the input buffer. We devise new practical hardware hashing method to perform fast table lookup by minimizing the number of external memory access and accelerating with hardware.

  • PDF

A Design Method of 2D Look-up Table of IPMSM for Electric Vehicle (전기자동차 구동용 IPMSM의 2D Look-up Table 작성기법)

  • Won, Il-Kwon;Kim, Do-Yun;Ko, An-Yeol;Lee, Jung-Hyo;Kim, Young-Real;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.104-105
    • /
    • 2013
  • When actual IPMSM is driving, it is difficult to figure out the correct current during the current control period due to the operation speed limit of digital signal processing. Therefore, in order to control IPMSM for electric vehicle efficiently, we should design 2D Look-up Table to find out optimal current reference corresponding to speed and torque of IPMSM. This paper explains the design method of 2D Look-up Table for optimal current control of constant torque area and constant output area of IPMSM for electric vehicle. Finally, experimental results are presented to verify the reliability of 2D Look-up Table.

  • PDF

The Accuracy of the Table Movement During a Whole Body Scan (전신 영상 검사 시행 시 테이블 이동속도의 정확성에 관한 연구)

  • Lee, Ju-Young;Jung, Woo-Young;Jung, Eun-Mi;Dong, Kyung-Rae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.86-91
    • /
    • 2009
  • Purpose: The whole body scan in Nuclear Medicine is a widely accepted examination and procedure. Especially, it is mainly used in bone, I-131, MIBI, and HMPAO WBC scans. The diverse uses of the whole body scan range from the HMPAO WBC scan with a speed of 13cm/min, to a whole body bone scan using the Onco. Flash technique with a speed of 30cm/min. The accuracy of table movement has a strong correlation with the image quality, and inaccuracy of speed could negatively affect the image quality. The purpose of this study is to evaluate the accuracy of the table movement while considering the influence of the age of the equipment and the variability in the weight of the patients. Material and Methods: The study was conducted using two of Seoul Asan Medical Center's SIEMENS gamma cameras which are commonly used in our whole body study. The first one is the oldest gamma camera, an ECAM plus (installed in 2000), and the last is brand new one, a SYMBIA T2 (installed in 2008). Three trials were conducted with the tables moving at a different speed each time; 10, 15 and 30 cm/min. The tables' speeds were measured by checking how long it took for the table to move 10cm, and this was repeated every 10cm until the table reached 100 cm. With an average body weight of the patients of about 60~70 kg, the table speed was measured with weights of 0 kg, 66 kg and 110 kg placed on the table, then compared among conditions. Results: The coefficient of variance (CV) of the ECAM plus showed 1.23, 1.42, 2.02 respectively when the table movement speeds were set at 10, 15, and 30 centimeters per minute. Under the same conditions, the SYMBIA T2 showed 1.23, 1.83 and 2.28 respectively. As table movement speed more, the variance of CV as the speed increases. When the patient body weight was set to 0, 66 and 110kg, the CV values of both cameras showed 0.96, 1.45, 2.08 (0 Kg), 1.32, 1.72, 2.27 (66 Kg) and 1.37, 1.73, 2.14 (110 Kg). There was no significant difference (p>0.05) in 95 percent of confidence intervals and measured CV values were acceptable. However, the CV value of the SYMBIA T2 was relatively larger than the ECAM plus. Conclusion: The scan speed of the whole body scan is predetermined based on which examination is being performed. It is possible for the accuracy of the speed to be affected, such as the age of the equipment, the state of the bearings or the weight of a patient. These factors can have a negative impact on the diagnostic consistency and the image quality. Therefore, periodic quality control should be needed on the gamma cameras currently being used, focusing on the table movement speed in order to maintain accuracy and reproducibility.

  • PDF

Removal of PVC from Granular Plastic Mixture by Using Air Table (Air Table을 이용한 입상플라스틱 혼합물로부터 PVC의 건식분리)

  • ;Hiroki Yotsumoto
    • Resources Recycling
    • /
    • v.10 no.6
    • /
    • pp.35-42
    • /
    • 2001
  • A study was conducted in order to remove Poly vinyl chloride (PVC) from granular plastic mixture by using Air Table. The motion of plastic particle on Air Table was investigated, and separation test on the plastic mixture with the mixing ratio of PVC 10% and PE 90% was conducted. At the optimum condition obtained from this study, that is frequency of 9.2Hz, air velocity of 1.05 m/sec, End-slope of $7.5 ^{\circ}$, Side-slope of $1^{\circ}$, Feeding speed of 450 g/min, etc., we could separate the PE-PVC mixture to PE (99.96% grade and 98.9% yield) and PVC (88.7% grade and 99.6% yield).

  • PDF