• Title/Summary/Keyword: Table quality

Search Result 623, Processing Time 0.026 seconds

Automatic Test case Generation Mechanism from the Decision Table of Requirement Specification Techniques based on Metamodel (메타모델 기반 요구사항 명세 기법인 의사 결정표를 통한 자동 테스트 케이스 생성 메커니즘)

  • Hyun Seung Son
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.2
    • /
    • pp.228-234
    • /
    • 2023
  • As the increasing demand for high-quality software, there is huge requiring for quality certification of international standards, industrial functional safety (IEC 61508), automotive (ISO 26262), embedded software guidelines for weapon systems, etc., in the industry. Software companies are very difficult to systematically acquire the quality certification in terms of cost and manpower of Startup, venture small-sized companies. For their companies one test case automatic generation is considered as a core technique to evaluate or improve software quality. This paper proposes a test case automatic generation method based on the design decision table for system and software design verification. We apply the proposed method with OMG's standard techniques of metamodel and model transformation for automatically generating test cases. To do this, we design the metamodels of design decision table (Model) and test case document (Text) and define model transformation to automatically generate test cases, which will expect to easily work MC/DC coverage.

Evaluation of the Korean National Food Composition Tables

  • Park, Hong-Ju;Chun, Hye-Kyung;Lee, Sung-Hyeon
    • Preventive Nutrition and Food Science
    • /
    • v.9 no.2
    • /
    • pp.190-193
    • /
    • 2004
  • This review was conducted to evaluate the 'Korean Food Composition Table' and establish it as an internationally accepted database by examining its contents and evolution over time. The food composition table has been published by National Rural Living Science Institute, every 5 years, listing the nutrient content for each food, as both the raw agricultural product and processed foods, since the 1$^{st}$ edition in 1979 by RDA (Rural Development Administration). This is the basic data applied to the evaluation of the nutritional value of foods in Korea. The data is used as a useful tool in many fields, not only for the establishment of the National Food Supply Plan but also for nutritional research, the draft of National Food Policy, and in clinical and epidemiological research. The database is also utilized by food service providers and food processors, etc. Consumers and the international society have been interested in the quality and safety of foods and raw agricultural products. As these data expand in volume, the type of foods included in the composition table is expanded to cover new additions for the convenience of users of the 'Nutrient Data Base' as judged by the publishers. The form of these reports varies, according to the current information, from a simple booklet to CD-ROM and to the Web service. We expect to continue to make improvements in the National Standard Table for food composition through expanding both the quantity and quality of data in an orderly manner. This effort can help food composition data to be comprehensively developed systematically and gradually at the national level.l.

Real-Time Color Gamut Mapping Method Based on the Three-Dimensional Difference Look-Up Table (3차원 차분 룩업 테이블을 이용한 실시간 색역 사상 기법)

  • Han, Dong-Il
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.6
    • /
    • pp.111-120
    • /
    • 2005
  • A cost effective three-dimensional color gamut mapping architecture is described. The conventional three-dimensional reduced resolution look-up table is considered and the concept of three-dimensional reduced resolution difference look-up table is introduced for cost effective and real-time color gamut mapping. The overall architecture uses one-dimensional memory decomposition of three-dimensional gamut mapping look-up table, three-dimensional interpolation and simple addition operation for generating the final gamut mapped colors. The required computational cost is greatly reduced by look-up table resolution adjustment and further reduced by the gamut mapping rule modification. The proposed architecture greatly reduces the required memory size and hardware complexity compared to the conventional method and it is suitable for real-time applications. The proposed hardware is suitable for FPGA and ASIC implementation and could be applied to the real-time display quality enhancement purposes.

Analysis of Interrelationship between Software Quality Characteristics and Engineering Attributes (소프트웨어 품질특성과 공학적 품질속성의 상호관계 분석)

  • 이상덕;정창신;유영관;이종무
    • Journal of the Korea Safety Management & Science
    • /
    • v.3 no.3
    • /
    • pp.213-220
    • /
    • 2001
  • This paper presents the interrelationship between software quality character and engineering attributes. The software quality characteristics and subcharacteristics are excerpted from IS0/IEC 9126 standards, and the engineering attributes are from Deutsch and Willis〔4〕. Based on the previous studies a subjective judgement, trisected interrelationship(strong, medium, weak) bet these two groups are derived. The results are summarized in a table, and can be used as a quick reference guide to the software quality engineering application such as quality evaluations for software products, selection of key engineering attributes for high-quality software production, and so forth.

  • PDF

The Accuracy of the Table Movement During a Whole Body Scan (전신 영상 검사 시행 시 테이블 이동속도의 정확성에 관한 연구)

  • Lee, Ju-Young;Jung, Woo-Young;Jung, Eun-Mi;Dong, Kyung-Rae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.86-91
    • /
    • 2009
  • Purpose: The whole body scan in Nuclear Medicine is a widely accepted examination and procedure. Especially, it is mainly used in bone, I-131, MIBI, and HMPAO WBC scans. The diverse uses of the whole body scan range from the HMPAO WBC scan with a speed of 13cm/min, to a whole body bone scan using the Onco. Flash technique with a speed of 30cm/min. The accuracy of table movement has a strong correlation with the image quality, and inaccuracy of speed could negatively affect the image quality. The purpose of this study is to evaluate the accuracy of the table movement while considering the influence of the age of the equipment and the variability in the weight of the patients. Material and Methods: The study was conducted using two of Seoul Asan Medical Center's SIEMENS gamma cameras which are commonly used in our whole body study. The first one is the oldest gamma camera, an ECAM plus (installed in 2000), and the last is brand new one, a SYMBIA T2 (installed in 2008). Three trials were conducted with the tables moving at a different speed each time; 10, 15 and 30 cm/min. The tables' speeds were measured by checking how long it took for the table to move 10cm, and this was repeated every 10cm until the table reached 100 cm. With an average body weight of the patients of about 60~70 kg, the table speed was measured with weights of 0 kg, 66 kg and 110 kg placed on the table, then compared among conditions. Results: The coefficient of variance (CV) of the ECAM plus showed 1.23, 1.42, 2.02 respectively when the table movement speeds were set at 10, 15, and 30 centimeters per minute. Under the same conditions, the SYMBIA T2 showed 1.23, 1.83 and 2.28 respectively. As table movement speed more, the variance of CV as the speed increases. When the patient body weight was set to 0, 66 and 110kg, the CV values of both cameras showed 0.96, 1.45, 2.08 (0 Kg), 1.32, 1.72, 2.27 (66 Kg) and 1.37, 1.73, 2.14 (110 Kg). There was no significant difference (p>0.05) in 95 percent of confidence intervals and measured CV values were acceptable. However, the CV value of the SYMBIA T2 was relatively larger than the ECAM plus. Conclusion: The scan speed of the whole body scan is predetermined based on which examination is being performed. It is possible for the accuracy of the speed to be affected, such as the age of the equipment, the state of the bearings or the weight of a patient. These factors can have a negative impact on the diagnostic consistency and the image quality. Therefore, periodic quality control should be needed on the gamma cameras currently being used, focusing on the table movement speed in order to maintain accuracy and reproducibility.

  • PDF

Quantitative Evaluation Index Derivation of the Software Based on ISO/IEC 9126-2 Metrics (ISO/IEC 9126-2 메트릭을 활용한 소프트웨어 정량적 평가 지표 도출)

  • Cho, Sungho;Jang, Joongsoon
    • Journal of Applied Reliability
    • /
    • v.16 no.2
    • /
    • pp.134-146
    • /
    • 2016
  • Purpose: Many domestic companies have to make out quantitative evaluation table in their proposal when they conduct the software R&D project. However, most of companies have a difficulty to select the evaluation items and criteria, also to derive a quantitative results. Therefore, we propose a method to derive the quantitative evaluation index by utilizing the ISO/IEC 9126-2. Methods: Analyzing ISO/IEC 9126-2, and we classify the quality metrics as high-classification and sub-classification for Web/App software, Embedded software and Installation software. Next, Conduct the metrics selection survey depending on importance and necessity. Then, carry out the case study. Verify the correspondence between evaluation items and criteria from original suggestion of company and from outcome by utilizing the ISO/IEC 9126-2 quality metrics. Results: It is possible to classify into two metrics, one for common software or one another for only special software. Furthermore, there is quality metrics that is more important and more necessary depending upon characteristics of the software. Conclusion: ISO/IEC 9126-2 quality metrics can be used to make an evaluation items and criteria for quantitative evaluation table of software product.

Comprehension and Appropriate Use of a Flood Table on a Gamma Camera (감마 카메라의 Flood Table에 대한 이해와 적절한 이용)

  • Kim, Jae-Il;Im, Jeong-Jin;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.29-33
    • /
    • 2011
  • Background and Purpose: Uniformity is the one of the important quality control features with respect to gamma cameras. To maintain adequate uniformity, we must acquire suitable flood table (=flood map) data because the flood table effects energy, and the type or dose of input radiation. Therefore, in this study we evaluated the difference in uniformity when uniformity does not match between the type of input radiation and the flood table data or collimator type. Subjects and Methods: For input radiation, we prepared 370 MBq of $^{57}Co$, $^{99m}Tc$, and $^{201}Tl$. Using SKYLight (Philips) and Infinia gamma cameras (GE), we acquired nine uniformity data that were corrected by technetium, cobalt flood table and did not corrected image for the three sources. Additionally, we acquired two uniformity images with a collimator that were corrected by intrinsic and extrinsic flood tables. Using this data, we evaluated and compared the uniformity values. Results: In the case of the SKYLight gamma camera, the uniformities of the images that matched between the input radiation and flood table with respect to $^{99m}Tc$ and $^{57}Co$ were better than the unmatched uniformity (3.96% vs. 5.69% ; 4.9% vs. 5.91%). However, because there was no thallium flood table, the uniformities of images at Tl were significantly incorrect (7.49%, 7.03%). The uniformities of the Infinia gamma camera had the same pattern as the SKYLight gamma camera (3.7% vs. 4.5%). Moreover, the uniformity of the $^{99m}Tc$ image acquired with a collimator and corrected by an extrinsic flood table was better than the intrinsic flood table (3.96% vs. 6.28%). Conclusion: Correcting an image by a suitable flood table can help achieve better uniformity for a gamma camera. Therefore, we have to acquire images with suitable uniformity correction, and update the flood table periodically. Whenever we acquire a nuclear medicine image, we always have to check the appropriate flood table according to the acquired condition.

  • PDF

Effect of Water Table Depth in Different Soil Texture on Quality of Barley and Wheat Grain (토성별 지하수위가 밀, 보리의 품질에 미치는 영향)

  • 이홍석;구자환
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.40 no.3
    • /
    • pp.278-284
    • /
    • 1995
  • This experiment was performed to characterize the optimum water table level for the grain quality, seed germination and diastic power of barley(var. Olbori) and wheat(var. Grumil). Olbori and Grumil grew in the 550 liter plastic pot that filled with silt loam or sandy loam. During the whole growth period, the underground water level adjusted to be 20, 30, 40, 50 and 70cm. Filled grain ratio and specific gravity were not affected by soil texture and water table. Low level of water table caused the increase of 1,000 grain weight in wheat and barley, but soil texture didn't. Crude protein content tended to be high as the water table level was high, especially in wheat. Change in crude protein content was affected by underground water level more than soil texture. And the affection was slightly higher in sandy loam than silt loam, but the difference was small. The higher level of water table led to the lower crude lipid content in barley and wheat grain. Crude lipid content of both wheat and barley grain grown in sandy loam was higher than those grown in silt loam. As the water table level down, the ash content of barley and wheat grain tend to increase, especially in sandy loam. Wheat flour yield was not affected by soil texture. It was about 65% at 20cm of water level and above 67% at 40cm water level. The seed germination of wheat and barley was more than 95% when the seeds were placed at 2$0^{\circ}C$ for three days. Regardless of soil texture, the lowest germination was seen at 20cm of water table level. And the seed germination rate increased as the underground water level became low. Above 89% of barley grains were germinated within 48 hours except 20cm level of water table in sandy loam. Diastic power of germinated barley was the lowest at 20cm of water table level, and it was almost unchanged below 30cm of water table level. And also it was not affected by soil texture.

  • PDF

Storage Quality of Ready-to-Eat Campbell Table Grapes as Affected by Active Modified Atmosphere Packaging (기체충진 포장조건에 따른 신선편이 캠벨 포도의 저장 중 품질변화)

  • Lee, Hyun-Hee;Hong, Seok-In;Kim, Dongman
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.559-567
    • /
    • 2012
  • The storage quality of ready-to-eat Campbell table grapes which were packaged under modified atmospheres was investigated in order to examine the effect of high $O_2$ and $CO_2$ on the fruit. Fresh table grapes with 10-15 berries were packed into polypropylene (PP) trays and were top-sealed with polythylene terephthalate/PP film. The initial gas compositions inside the packages were air, 20% $O_2$/10% $CO_2$/70% $N_2$, and 40% $O_2$/60% $N_2$. Sealed packages with low density polyethylene film bags and perforated PP trays were also used as a further treatment and control, respectively. The quality attributes were assessed during storage at $5^{\circ}C$ for 28 days. Fruit packaged in high $CO_2$ concentration showed the lowest viable cell counts of inherent microorganisms among all samples, although they suffered from severe off-flavors. High levels of $O_2$ significantly lowered flesh weight loss and maintained the flavor of grape. In an overall sensory aspect, the high $O_2$ and $CO_2$ packages exhibited greater scores than the air and control at the end of the storage period. Other quality attributes showed no significant differences among treatments. Results suggest that packaging with an appropriate combination of high $O_2$ and $CO_2$ can be used as an effective processing treatment for improvement of the storability of ready-to-eat table grapes.

Effect of Polyphenol Oxidase Activity and Total Phenolic Content on Browning and Quality of Dried-Persimmon According to Maturity Degree of Astringent Persimmon

  • Jung, Kyung-Mi;Song, In-Gyu;Kim, Se-Jong;Lee, Sang-Han
    • Current Research on Agriculture and Life Sciences
    • /
    • v.33 no.2
    • /
    • pp.65-68
    • /
    • 2015
  • Hunter's color value "a" in dried-persimmon of table and full ripe fruit was higher than that in unripe fruit. In case of soluble solid content, full ripe fruit was $50^{\circ}Brix$, the highest degree, while unripe fruit was $40^{\circ}Brix$, the lowest degree. PPO activation of unripe fruit was 4.7, which was higher than table-ripe fruit (0.7) and full ripe (1.0). Polyphenol oxidase activation remained even while drying, but there was no difference in PPO activation degree as drying period increased. Total phenol content of unripe fruit was 101.4, which was higher than table-ripe fruit (57.5) and full ripe fruit (67.4). Total phenol content level increased as drying period increased, which was based on fresh weight. Hardness of unripe and table ripe fruit continued to decrease until three weeks during softening. After that, hardness was high and it started drying. However, in full ripe fruit, hardness increased after two weeks and softening was fast during the drying period, and its weight reduction rate was lower than that of unripe and table ripe fruit.