• Title/Summary/Keyword: TSS

Search Result 481, Processing Time 0.03 seconds

The efficiency evaluation for TQM activities

  • Yoo Hanjoo;Lee Jeong-Dong
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 1998.11a
    • /
    • pp.419-428
    • /
    • 1998
  • In this paper, we analyzed two methodologies to evaluate the total quality management activities comparatively. One of them is the traditional scoring system (TSS) by analytic hierarchy process (AHP) and the other is the efficiency measuring system (EMS) by data envelop analysis (DEA), It is demonstrated that the index by TSS and the efficiency index by EMS are not correlated. Also, the efficiency index by EMS in terms of company characteristics such as the size of company and ISO certifications is different from the index by TSS. The result implies that to evaluate the quality activities by EMS is needed as a supplementory methodology.

  • PDF

Performance of a Foam Fractionator in a Lab-scale Seawater Recirculating Aquaculture System

  • Peng Lei;Jo Jae-Yoon
    • Fisheries and Aquatic Sciences
    • /
    • v.6 no.4
    • /
    • pp.187-193
    • /
    • 2003
  • The performance of a foam fractionator to remove TAN, $NO_2,\;NO_3$, TSS, protein, and $PO_4-P$ at different superficial air velocities and foam overflow heights was evaluated in a lab-scale seawater recirculating system for culture of Korean rockfish (Sebastes schlegeli). The foam overflow rates increased with the increase of superficial air velocities, but decreased with the increase of foam overflow heights. Concentrations of all the water quality variables in the foam condensates increased with the increase of foam overflow height, but decreased with the increase of superficial air velocities. TSS, protein, and phosphate enrichment factors were within the range of 6.4-39.4, 1.6-7.3 and 1.2-3.9, respectively. Low values of TAN, $NO_2,\;and\;NO_3$ enrichment factors were obtained and they indicate that foam fractionation is rot an effective way to remove dissolved inorganic nitrogen. The calculated maximum daily removal values for TSS and protein were 10.9 and 1.4g, respectively.

Clinical Study of 8 Diabetic Patients with Paresthesia (감각이상을 주소로 내원한 당뇨병 환자 8례에 대한 임상보고)

  • Kim, Jin-Mi;Cho, Chung-Sik;Kim, Chul-Jung
    • The Journal of Internal Korean Medicine
    • /
    • v.31 no.2
    • /
    • pp.372-379
    • /
    • 2010
  • Objective : The purpose of this study was to report the effect of Bogijetong-tang on diabetic peripheral neuropathy. Methods : Nine patients who were diagnosed or suspected with diabetic peripheral neuropathy enrolled in this study. They took Bogijetong-tang 2 or 3 times a day and were given acupuncture therapy. To evaluate the therapeutic effect, Visual Analog Scale (VAS) or Total Symptom Score (TSS) were examined at intervals of about 7 days. Result : TSS score decreased an average of 2.74 points and VAS scores decreased an average of 3.67 points. As the pain decreased, accompanied gait disturbance also improved in some patients. Conclusion : Bogijetong-tang is effective in treating diabetic peripheral neuropathy, but study of the concrete mechanism and efficacy is needed.

A comparison of the traditional scoring system with the efficiency measuring system for evaluating the TQM activities

  • Yoo, Han-Joo;Lee, Jeong-Dong
    • Journal of Korean Society for Quality Management
    • /
    • v.27 no.2
    • /
    • pp.47-56
    • /
    • 1999
  • In this paper, we analyzed two methodologies to evaluate the total quality management activities comparatively. One of them is the traditional scoring system (TSS) by analytic hierarchy process (AHP) and the other is the efficiency measuring system (EMS) by data envelop analysis (DEA). It is demonstrated that the index by TSS and the efficiency index by EMS are not correlated. Also, the efficiency index by EMS in terms of company characteristics such as the size of company and ISO certifications is different from the index by TSS. The result implies that to evaluate the quality activities by EMS is needed as a supplementary methodology.

  • PDF

A Fast Hierarchical Motion Vector Estimation Using Mean Pyramids (평균 피라미드를 이용한 계층적 고속 이동벡터 추정)

  • 남권문;김준식;박래홍;심영석
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.6
    • /
    • pp.35-48
    • /
    • 1993
  • In this paper, a hierarchical motion vector estimation algorithm using pyramidal structure is proposed. Using a smaller measurement window at each level of a pyramid than that of the conventional scheme, the proposed algorithm, based on the TSS(three step search), reduces the computational complexity greatly with its performance comparable to that of the TSS. By increasing the number of cnadidate motion vectors which are to be used as the initial search points for motion vector estimation at the next level, the performance improves further. Then the computational complexity of the proposed hierarchical algorithm depends on the number of candidate motion vectors, with its PSNR (peak signal to noise ratio) ranging between those of the TSS and the full search method. The simulation results with two different block sizes and various test sequences are given and its hardware implementation is also sketched.

  • PDF

Improvement of Medium and Small Urban Stream Water Quality and Applicability of Design Factor Using Biological and Physicochemical Processing (도심지역 내 중·소하천 수질 개선을 위한 가압부상 및 관로형 미생물 부착 공정 적용에 관한 연구)

  • Kim, Moon-Ki;Choi, Jung-Su;Kim, Sam-Ju;Kim, Hyun-Gu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.7
    • /
    • pp.509-517
    • /
    • 2013
  • The purpose of this study is to assess the applicability of device-type stream coagulation process which combines physiochemical, biological processing for efficient improvement of water quality in small, middle-sized urban streams. The stream purification facility of this study is compose of pressure flotation type Micro Bubble Process(MBP) to remove TSS and TP and conduit line type Attached Microbial Pipe System(AMPS) to remove BOD. Test conditions of each device were set by floating stay time and change of ultra fine bubble injection amount of MBP, and change of AMPS stay time. Also, removal efficiency of pollution sources of each process were assess by change of season. As result of continuous operation of each process, MBP showed a maximum of TSS 83.69%, TP 95.15% process efficiency and AMPS showed a maximum of 52.95% TBOD5 removal efficiency. Also as result of circular operation of each process, MBP showed a maximum of TSS 69.75%, TP 70.17% process efficiency and AMPS showed a maximum of 68.58% TBOD5 removal efficiency. Therefore, it is considered that this stream coagulation process is effective in improving the water quality of streams in urban areas.

Changes in Pollutant Concentrations by Artificial Floating Island Installed in Reservoir for Irrigation (농업용 저수지에 설치한 인공식물섬에 의한 오염물질 농도의 변화)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.2
    • /
    • pp.23-32
    • /
    • 2006
  • Total suspended solids (TSS), five-day biochemical oxygen demand ($BOD_5$), total nitrogen (T-N), and total phosphorous (T-P) concentrations around and under a floating island were examined from October 2002 to September 2003. The island was installed in July 2002 on the surface of an agricultural irrigation reservoir located in the southern part of the Korean Peninsula. It was composed of six polyethylene panels. Each panel was 2 m (length) ${\times}$ 1 m (width) ${\times}$ 0.02 m (thick) and had about thirty-two holes each with a diameter of eight centimeters, through which plant roots grew down into the water. Coconut fibers of nine-centimeters in height were placed on the panel, which sustained plants rhizomes and roots. Both the fibers and the panel were raped with polyethylene wire mashes. About thirty irises (Iris pseudoacorus) were planted into the fibers of each panel. The concentrations of TSS, $BOD_5$, T-N and T-P below the island during the iris-growing season averaged 9.70, 2.59, 3.61 and 0.14 mg/L, respectively and those around it averaged 9.99, 2.83, 4.07 and 0.16 mg/L, respectively. The average concentrations of TSS, $BOD_5$, T-N and T-P below it during the iris non-growing season were 8.68, 2.37, 3.25 and 0.14 mg/L, respectively and those near it were 8.76, 2.43, 3.34 and 0.15 mg/L, respectively. At a significance level of ${\alpha}$=0.05, $BOD_5$, T-N and T-P concentrations under the island during the iris-growing season were significantly low when compared with those around it except TSS. No differences in TSS, $BOD_5$, T-N and T-P concentrations between around and near it were found at a significance level of ${\alpha}$=0.05 during the iris non-growing season. The removal of $BOD_5$, T-N, and T-P during the growing season were significantly high when compared with those during the non-growing season. TSS abatement of the floating island was very low during both the growing and non-growing seasons. The island's reductions of $BOD_5$, T-N and T-P were good during the growing season, especially T-N and T-P, which have been considered as primary pollutant sources causing the water quality degradation of reservoirs. The removal of T-N and T-P was primarily attributed to the absorption of nitrogen and phosphorous by the irises during the growing season.

Feasibility Study on Removal of Total Suspended Solid in Wastewater with Compressed Media Filter (압축성 여재 여과를 이용한 하수의 고형물질 제거 타당성 연구)

  • Kim, Yeseul;Jung, Chanil;Oh, Jeill;Yoon, Yeomin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.2
    • /
    • pp.84-95
    • /
    • 2014
  • Recently, as a variety of techniques of CMF (Compressed media filter) that has advantages of high porosity and compressibility have been developed in the U.S. and Japan. Therefore, the interest of intensive wastewater treatment using CMF has grown. This study examined the feasibility of CMF with varying sewage water quality to determine the optimum operating conditions. A preliminary tracer test that investigated the filtering process under various compression and flow rate conditions was performed. In a high compression condition, different porosities were applied to each depth of the column. Therefore, a distinct difference between a theoretical value and results of tracer test was observed. For the TSS (Total suspended solid) removal and particle size distribution of CMF for pre-treatment water under the various compression conditions, the compression ratio of 30 percent as the optimal condition showed greater than 70% removal efficiency. In addition, the compression ratio of >15% was required to remove small-sized particles. Also, an additional process such as coagulation is necessary to increase the removal efficiency for < $10{\mu}m$ particles, since these small particles significantly influence the effluent concentration. Modeling results showed that as the compression rate was increased, TSS removal efficiency in accordance with each particle size in the initial filtration was noticeably observed. The modeling results according to the depth of column targeting $10{\mu}m$ particles having the largest percentage in particle size distribution showed that 150-300 mm in filter media layer was the most active with respect to the filtering.

A Rapid Signal Acquisition Scheme for Noncoherent UWB Systems (비동기식 초광대역 시스템을 위한 고속 신호 동기획득 기법)

  • Kim Jae-Woon;Yang Suck-Chel;Choi Sung-Soo;Shin Yo-An
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.4C
    • /
    • pp.331-340
    • /
    • 2006
  • In this Paper, we propose to extend the TSS-LS(Two-Step Search scheme with Linear search based Second step) scheme which was already proposed by the authors for coherent UWB(Ultra Wide Band) systems, to rapid and reliable acquisition of noncoherent UWB systems in multipath channels. The proposed noncoherent TSS-LS employing simple energy window banks utilizes two different thresholds and search windows to achieve fast acquisition. Furthermore, the linear search is adopted for the second step in the proposed scheme to correctly find the starting point in the range of effective delay spread of the multipath channels, and to obtain reliable BER(Bit Error Rate) performance of the noncoherent UWB systems. Simulation results with multipath channel models by IEEE 802.15.3a show that the proposed two-step search scheme can achieve significant reduction of the required mean acquisition time as compared to general search schemes. ]n addition, the proposed scheme achieves quite good BER performance for large signal-to-noise ratios, which is favorably comparable to the case of ideal perfect timing.

Seasonal Performance of Constructed Wetland for Nonpoint Source Pollution Control (비점오염원 제어를 위한 인공습지의 계절변화에 따른 처리효율 평가)

  • Ham, Jong-Hwa;Han, Jung-Yoon;Kim, Hyung-Chul;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.4 s.118
    • /
    • pp.471-480
    • /
    • 2006
  • The field scale experiment was performed to examine the performance of the constructed wetland for nonpoint source (NPS) pollution loading reduction. Four sets (each set of 0.88 ha) of wetland (0.8 ha) and pond (0.08 ha) systems were used. Water flowing into the Seokmoon estuarine reservoir from the Dangjin stream was pumped into wetland systems. Water depth was maintained at 0.3-0.5 m and hydraulic retention time was managed to about 2-5 days; emergent plants were allowed to grow in the wetland. The wetland effluent concentrations of $BOD_5$, TSS, and T-N were higher in winter than in the growing season excepting the T-P, and effluent $BOD_5$ concentration was higher than influents in winter. Mass retention of T-N and T-P was stable throughout the year, whereas mass retention of $BOD_5$ and TSS was decreased in winter. $BOD_5$, TSS, T-N, and T-P performance of the experi-mental system was compared with the existing database (North American Treatment Wetland Database), and was within the range of general system performance. From the first-order analysis, T-P was virtually not temperature dependent, and $BOD_5$ and TSS were more temperature dependent than T-N. Overall, the wetland system was found to be an adequate alternative for treating polluted stream water with stable removal efficiency and recommended as a NPS control measures.