• Title/Summary/Keyword: TSP concentration

Search Result 174, Processing Time 0.028 seconds

A Study on the Characteristics of Concentrations of Atmospheric Aerosols in Pusan (부산지역의 입자상 대기오염물질의 농도특성에 관한 연구)

  • 최금찬;유수영;전보경
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.2
    • /
    • pp.41-48
    • /
    • 2000
  • This study has been carried out to determine the seasonal characteristics of concentration of various ionic (CI-, NO3-, SO42-, Na+, NH+, K+, Ca2+) and heavy metallic (Pb, Mn, Cu, Ni) species in Pusan from August 1997 to April 1998. The concentrations of CI-, Na+, K+ were higher during summer with 2.98 ${\mu}{\textrm}{m}$/㎥. Seasonal variation of total concentration of but the concentration of NH4+ was higher during winter with 2.46${\mu}{\textrm}{m}$/㎥. Seasonal variation of total concentration of heavy metals(Pb, Cu, Mn, Ni) were 186.0 ng/㎥ in summer, 222.6 ng/㎥ in autumn, and 135.83 ng/㎥ in winter. Over the seasons inspected, the concentration of Mn was higher in coarse particles than fine particles and concentration of Ni was higher in fine particles than coarse particles. during yellow sand period, the concentration of TSP was increased about two times than that of other period. SO42-, Ca2+ concentrations were higher than other ionic components because of soil particles. The concentration of Ni showed 94.62ng/㎥ was increased about 4~5 times than other period. Principal component of the yellow sand, SO42-, Ca2+ could be discreased by rainfall and washout effect of atmospheric aerosol was higher in coarse particles than fine particles. Results from PCA(principal component analysis) showed that major pollutant was NaCl by seasalt particulate and (NH4)2SO4.

  • PDF

Exposure Assessments of Environmental Contaminants in Ansim Briquette Fuel Complex, Daegu(II) - Concentration distribution and exposure characteristics of TSP, PM10, PM2.5, and heavy metals - (대구 안심연료단지 환경오염물질 노출 평가(II) - TSP, PM10, PM2.5 및 중금속 농도분포 및 노출특성 -)

  • Jung, Jong-Hyeon;Phee, Young-Gyu;Lee, Jun-Jung;Oh, In-Bo;Shon, Byung-Hyun;Lee, Hyung-Don;Yoon, Mi-Ra;Kim, Geun-Bae;Yu, Seung-do;Min, Young-Sun;Lee, Kwan;Lim, Hyun-Sul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.380-391
    • /
    • 2015
  • Objectives: The objective of this study is to assess airborne particulate matter pollution and its effect on health of residents living near Ansim Briquette Fuel Complex and its vicinities. Also, this study measured and analyzed the concentration of TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals which influences on the environmental and respiratory disease in Ansim Briquette Fuel Complex, Daegu, Korea. Methods: In this study, we analyzed various environmental pollutants such as particulate matter and heavy metals from Ansim Briquette Fuel Complex that adversely affected local residents's health. In particular, we verified the concentration distribution and characteristics of exposure for TSP, $PM_{10}$, and $PM_{2.5}$ among particulate matters, and heavy metals(Cd, Cr, Cu, Mn, Ni, Pb, Fe, Zn, and Mg). In that regard, the official test method on air pollution in Korea for analysis of particulate matter and heavy metal in atmosphere were conducted. The large capacity air sampling method by the official test method on air pollution in Korea were applied for sampling of heavy metals in atmosphere. In addition, we evaluated the concentration of seasonal environmental pollutants for each point of residence in Ansim Briquette Fuel Complex and surrounding area. The sampling measured periods for air pollutants were from August 11, 2013 to February 21, 2014. Furthermore, we measured and analyzed the seasonal concentrations(summer, autumn and winter). Results: The average concentration for TSP, $PM_{10}$, and $PM_{2.5}$ by direct influence area at Ansim Briquette Fuel Complex were 1.7, 1.4 and 1.9 times higher than reference region. In analysis results of seasonal concentrations for particulate matter in four direct influence and reference area, concentration levels for winter were generally somewhat higher than concentrations for summer and autumn. The average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were $0.0008{\pm}0.0004{\mu}g/Sm^3$, $0.0141{\pm}0.0163{\mu}g/Sm^3$, $0.0248{\pm}0.0059{\mu}g/Sm^3$, $0.0026{\pm}0.0011{\mu}g/Sm^3$, $0.0272{\pm}0.0084{\mu}g/Sm^3$, $0.4855{\pm}0.1862{\mu}g/Sm^3$, and $0.3068{\pm}0.0631{\mu}g/Sm^3$, respectively. In particularly, the average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were 1.9, 3.6, 2.1, 1.9, 1.4, 2.6, and 1.2 times higher than reference area, respectively. The continuous monitoring and management were required for some heavy metals such as Cr and Ni. Moreover, the average concentration in winter for particulate matter in direct influence area at Ansim Briquette Fuel Complex were generally higher than concentrations in summer and autumn. Also, average concentrations for TSP, $PM_{10}$, and $PM_{2.5}$ were from 1.5 to 2.0 times, 1.2 to 1.8 times, and 1.1 to 2.3 times higher than reference area, respectively. In results for seasonal atmospheric environment, TSP, $PM_{10}$, $PM_{2.5}$, and heavy metal concentrations in direct influence area were higher than reference area. Especially, the concentrations in C station were a high level in comparison with other area. Conclusions: In the results, some particulate matters and heavy metals were relatively high concentration, in order to understand the environmental pollution level and health effect in surrounding area at Ansim Briquette Fuel Complex. The concentration of some heavy metals emitted from direct influence area at Ansim Briquette Fuel Complex were relatively higher than reference area. In particular, average concentration for heavy metals in this study were higher than average concentrations in air quality monitoring station for heavy metal for 7 years in Deagu metropolitan region. Especially, the residents near Ansim Briquette Fuel Complex may be exposed to the pollutants(TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals, etc) emitted from the factories in Ansim Briquette Fuel Complex.

밀폐된 공간에서 환기에 의한 ETS 성분 제거

  • 황건중;이문수;나도영
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.21 no.1
    • /
    • pp.102-108
    • /
    • 1999
  • This study was conducted to evaluate the ventilation to remove gases, vapor and particles of environmental tobacco smoke(ETS) in a closed room. The ventilation rate choosed were 0.445 ㎥/min, 0.528 ㎥/min, and 0.625 ㎥/min. ETS components measured were total suspended particle(TSP), ultraviolet particulate matter(UVPM), fluorescent particulate matter(FPM), solanesol, carbon dioxide($CO_2$), carbon monoxide(CO), nicotine, and 3-ethenylpyri-dine(3-EP). The concentration of ETS components measured rapidly decreased as increasing ventilation rate, but the removal efficiency by ventilation was different from each ETS compounds. The $CO_2$, and CO, gaseous components of ETS, were dominant components to be removed from the room by ventilation. The ventilation with 0.528 ㎥/min for 1 hr was enough to remove over 99% of those gaseous components. Nicotine and 3-EP needed the ventilation for 2 hrs to reduce over 95 % of those components. As the same ventilation rate, 99 % of TSP and solanesol concentration were removed from the room within 2 hrs, UVPM and FPM concentration decreased 90 %.

  • PDF

The Patterns of the PM Air Quality Guidance Level in Seoul during 1990~2000 (서울시 대기관측망을 중심으로 부유분진 기준농도 초과자료를 이용한 시공간적 경향성 비교 연구)

  • Choi, Ye-Jin;Kim, Min-Young;Kim, Ki-Hyun
    • Journal of the Korean earth science society
    • /
    • v.24 no.3
    • /
    • pp.190-204
    • /
    • 2003
  • The PM (particulate matter) concentration data sets exceeding the Daily Air Quality Guidance Levels (i.e., established by the Korean Ministry of Environment) were selected from 31 air qality monitoring stations in Seoul from 1990 to 2000. (For reference, the 24hr environmental standard values of PM$_{10}$ and TSP are 150 and 300${\mu}$g/m$^{3}$, respectively.) When the data sets were compared between land use types, both PM fractions were exceeded most frequently in residential areas. However, the highest TSP concentration was measured at industrial areas (351.0${\pm}$35.9${\mu}$g m$^{3}$), while the highest PM$_{10}$ concentration was measured in residential areas (182.9${\pm}$42.4${\mu}$g m$^{3}$). When the temporal distribution patterns of the exceedance data sets were compared to those measured routinely (without any discrimination based on exceedance criteria), large differences were present. It was demonstrated that the occurrences of exceedance data sets increased rather significantly in recent years.

Measurement and Analysis of Dust Concentration in a Fattening Pig House Considering Respiratory Welfare of Pig Farmers (비육돈사 작업 종사자의 호흡기 관련 공기 중 분진 농도 측정 및 분석)

  • Kwon, Kyeong-Seok;Lee, In-Bok;Hwang, Hyun-Seob;Ha, Tae-Hwan;Ha, Jung-Soo;Park, Se-Jun;Jo, Ye-Seul
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.5
    • /
    • pp.25-35
    • /
    • 2013
  • In swine house, dust generation comes from various sources and is known to be harmful both for the animals and the farmers because the dust contains biological and gaseous matters. When farmers are constantly exposed to the dusts, they can suffer chronic or acute respiratory symptoms and have high probability of manifesting various diseases. To address this problem, understanding of the mechanism of dust generation is very important. In this paper, the dust concentration of inhalable, respirable, TSP and $PM_{10}$ were monitored and analyzed according to the pig-activity level, ventilation quantity and feeding method in fattening pig house. From the measured results, in case of the concentration of TSP, an inverse-linear relation with ventilation rate ($R^2=0.88$) and linear relation with the installation height of feed supply pipe ($R^2=0.73$) were determined. However in case of the concentration of $PM_{10}$, no particular relationship with the variables was observed. Using the concentration of inhalable and respirable dust based on the pig-activity level, multi-variate regression analysis was conducted and results have shown that the movement of pigs can contribute to the dust generation (p<0.05, $R^2=0.71$, 0.61). The relationship determined between dust generation and environmental variables investigated in this study is very significant and useful in conducting dust-reduction researches.

Dust Spatial Distribution and Emission of Tunnel Ventilated Windowless Broiler Building (터널환기 무창육계사의 분진크기별 분포와 배출농도에 관한 연구)

  • Choi, H.C.;Yeon, G.Y.;Spmg, J.I.;Kang, H.S.;Kwon, D.J.;Yoo, Y.H.;Yang, C.B.;Chun, S.S.;Kim, Y.K.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.3
    • /
    • pp.115-122
    • /
    • 2006
  • This study investigated the spatial distribution of dust originating from tunnel-ventilated windowless broiler building measuring 12 m wide, 61 m long, with a side wall height of 3 m and a capacity of 16,982 birds. Dust concentrations in terms of total suspended particles (TSP), and particulate matter of sizes $10\;{\mu}m$(PM10), $2.5\;{\mu}m$(PM2.5), and $1\;{\mu}m(PM1)$ were measured at 30 minutes interval by using GRIMM Aerosol Monitor (GRIMM AEROSOL). The spatial distribution of dust showed the lower dust concentration in the inlet than in the outlet of the tunnel ventilation, and dust concentration decreasing as the dust size decreased, as follows: $317.9\;{\mu}g/m^3$ TSP; $74.7{\mu}m/m^3$ PM10; $9.7\;{\mu}g/m^3$ PM2.5; and $6.2\;{\mu}g/m^3$ PM1 in the inlet; and $2,678.5\;{\mu}g/m^3$ TSP; $555.5\;{\mu}g/m^3$ PM10; $33.3\;{\mu}g/m^3$ PM2.5; and $10.2\;{\mu}g/m^3$ PM1 in the outlet. The dust concentration emitted from the tunnel ventilated fan was $446.6\;{\mu}g/m^3$ TSP; $129.1\;{\mu}g/m^3$ PM10; $15.8\;{\mu}g/m^3$ PM2.5; and $6.1\;{\mu}g/m^3$ PM1 in the 3 meters from the fan and $25.1\;{\mu}g/m^3$ TSP; $8.8\;{\mu}g/m^3$ PM10; $5.6\;{\mu}g/m^3$ PM2.5; and $4.9\;{\mu}g/m^3$ PM1 in the 50 meters from the fan.

  • PDF

Measurement of Airborne Particles and Volatile Organic Compounds Produced During the Heat Treatment Process in Manufacturing Welding Materials

  • Myoungho Lee;Sungyo Jung;Geonho Do;Yeram Yang;Jongsu Kim;Chungsik Yoon
    • Safety and Health at Work
    • /
    • v.14 no.2
    • /
    • pp.215-221
    • /
    • 2023
  • Background: There is little information about the airborne hazardous agents released during the heat treatment when manufacturing a welding material. This study aimed to evaluate the airborne hazardous agents generated at welding material manufacturing sites through area sampling. Methods: concentration of airborne particles was measured using a scanning mobility particle sizer and optical particle sizer. Total suspended particles (TSP) and respirable dust samples were collected on polyvinyl chloride filters and weighed to measure the mass concentrations. Volatile organic compounds and heavy metals were analyzed using a gas chromatography mass spectrometer and inductively coupled plasma mass spectrometer, respectively. Results: The average mass concentration of TSP was 683.1±677.4 ㎍/m3, with respirable dust accounting for 38.6% of the TSP. The average concentration of the airborne particles less than 10 ㎛ in diameter was 11.2-22.8×104 particles/cm3, and the average number of the particles with a diameter of 10-100 nm was approximately 78-86% of the total measured particles (<10 ㎛). In the case of volatile organic compounds, the heat treatment process concentration was significantly higher (p < 0.05) during combustion than during cooling. The airborne heavy metal concentrations differed depending on the materials used for heat treatment. The content of heavy metals in the airborne particles was approximately 32.6%. Conclusions: Nanoparticle exposure increased as the number of particles in the air around the heat treatment process increases, and the ratio of heavy metals in dust generated after the heat treatment process is high, which may adversely affect workers' health.

A Study on the Contribution of Fugitive Dust to the Residential Area near the Port of Incheon

  • Jeon, Ki-Joon;Bang, Jin-Chul;Jung, Yong-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E4
    • /
    • pp.145-155
    • /
    • 2001
  • Simple mass balance method was developed to estimate the contribution of two major fugitive dust sources in the Port of Incheon to a nearby residential area in this study. Using the relatively small number of TSP data as well as the data on mass fraction of Fe and organic materials in the sampled dust, our simplified method demonstrated its ability to estimate the contribution of each fugitive source to a specific location including the residential area with relatively reasonable accuracy. It is clear from this simple method can be applied to the situation where two major fugitive dust sources are responsible for the high TSP concentration around the source area and there are clear marker chemicals representing the characteristics of the fugitive dust sources.

  • PDF

Characterization of Size distribution of Anion Species in Atmospheric Aerosols (대기에어로졸중 음이온성분에 대한 입경분포의 변화특성)

  • 최금찬;박정호;임경택
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.2
    • /
    • pp.124-129
    • /
    • 1994
  • Aerosol size distribution was determined using Anderson sampler for the anions( sulfate nitrate and chloride ) and TSP. Ionic species concentration and size distribution have been investigated in the daytime and nightime individually. Size classified samples were extracted with distilled water and analyzed for C $l^{[-10]}$ , N $O_3$$^{[-10]}$ and S $O_4$$^{2-}$, by ion chromatography. The size distribution of these ions and TSP was analyzed to investigate the seasonal and diurnal variation of concentrations as follows: (1)Size distribution of TSP showed bi- modal type in the daytime, but indicated tri-mode distribution in the nightime without any seasonal variation. (2)Sulfate concentrations were higher in fine- mode both in the daytime and nightime but fraction of sulfate was higher in coarse-mode during the Yellow Sand Period. (3)Nitrate and Chloride ions are dominant in fine-mode in winter while dominant in coarse-mode in the summer.

  • PDF

Genotoxicity of Total Suspended Particulate in Chuncheon Area (춘천지역 대기부유분진의 DNA 손상효과)

  • Kim, Nam-Yee;Lim, Beng-Chan;Weon, Wun-Jae;Hyun, Geun-Woo;Choi, Geum-Jong;Song, Eun-Jeong;Heo, Moon-Young
    • YAKHAK HOEJI
    • /
    • v.51 no.6
    • /
    • pp.415-423
    • /
    • 2007
  • This study was to evaluate the genotoxic effects of airborne particulate matters using single cell gell elec trophoresis (comet assay) in A549 human lung carcinoma cells. The total suspended particulate (TSP) was collected on back-up filter in Chuncheon, Kangwon Do, South Korea from April, 2003 to February, 2005. The concentrations of TSP, B(a)p and most of heavy metals seemed to be higher in spring and winter, and lower in summer. And they showed higher concentration in the commercial areas and the residential area having more traffics than in the rural area. It was found that A549 cells interacting with the organic extract of TSP showed more DNA single-strand breaks compare to untreated cells. The genotoxicity of the organic extract of TSP was increased with the pre-treatment of S-9 mixture during the culture or with the treatment of endonuclease after cell lysis. The DNA damage by the organic extract of TSP was higher in winter and the commercial area than in summer and the rural area. This study suggests that TSP, heavy metals and B(a)P analyzed showed significant variation depend on the seasons and the areas which are correlated with the DNA damage evaluated by Comet assay, indicating that genotoxic biomarker is useful for toxicological evaluation of air quality.