• Title/Summary/Keyword: TSP and PM10 concentration

Search Result 64, Processing Time 0.209 seconds

Measurement of Dust Concentration in a Naturally Ventilated Broiler House according to Season and Worker's Access (윈치커튼식 계사의 시기 및 작업자 출입에 따른 분진 발생 농도 측정 연구)

  • Jo, Ye-seul;Kwon, Kyeong-seok;Lee, In-bok;Ha, Tae-hwan;Park, Se-jun;Kim, Rack-woo;Yeo, Uk-hyeon;Lee, Sang-yeon;Lee, Seung-no
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.6
    • /
    • pp.35-46
    • /
    • 2015
  • Improvement in domestic poultry production has a positive effect on the export competitiveness of the poultry industry. However, overproduction and enlargement of facilities to assure a supply increase a stocking density which make a poor environment in the broiler house. In particular, an intensive rearing environment is vulnerable to dust control that causes respiratory diseases, such as asthma, bronchitis, etc., to farmers and broilers. However, monitoring data and research for environment control are not adequate, and there are no air quality regulations in broiler houses in Korea. In this study, TSP, PM10, inhalable dust and respirable dust concentration were monitored according to season, age of broiler and broiler's activities. Air quality assessment was also performed in accordance with the threshold limit value by Donham et al. (2000). The TSP concentrations were 77.5 %, 219.7 % higher and PM10 concentrations were 121.2 %, 303.8 % higher when change of season and winter respectively than summer. There were significantly different concentrations according to season and age of broiler. Inhalable and respirable dust concentration were also clearly different according to the season and age of broiler. A high dust concentration was observed, specifically exceeding the threshold limit by 119 % in the winter. In the case of the broiler's motion was activity according to worker's access into the broiler house, concentration level was 769.6 % higher than broiler's motion was stable and exceeded the threshold limit. These results suggest that the worker should put on protective equipment to protect there's respiratory health in the broiler house.

Analysis of Dust Concentration in Dairy Farm according to Sampling Location and Working Activities (유우사 내부 위치 및 작업 형태에 따른 분진 모니터링 및 분석)

  • Park, Gwanyong;Kwon, Kyeong-Seok;Lee, In-bok;Ha, Taehwan;Kim, Rack-Woo;Lee, Minhyung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.3
    • /
    • pp.71-81
    • /
    • 2017
  • Organic dust generated inside livestock facilities includes toxic organic matters such as bacteria and endotoxin. Dust can cause respiratory disease for worker and livestock, and consequently, degradation of welfare and productivity. Influence of dust on livestock workers has been studied since the 1970s. However, exposure limit for cattle farmer has not been established, unlike exposure limit for pig and poultry farmer. Furthermore, study on air quality inside livestock facility, especially inside dairy farm has been rarely conducted in Korea. In this study, dust concentration of TSP, PM10, inhalable and respirable dust has been monitored in the commercial dairy house according to location and working activities. Bedding material inside the stall was one of the major sources of dust. The amount of dust was related to water content level of the bedding material. Dust concentration was relatively high in leeward location, and the highest concentration was measured during TMR mixing process. The maximum value of inhalable dust concentration was 29.1 times higher than the reference value as fine particles drop to the TMR mixer. Dust generated by TMR mixing was presumed to decrease by adjusting moisture and drop height of feed.

Characteristics of Size Distribution and Fugitive Emissions of Particulate Matter in Foundries (주물사업장의 입자상물질 입경분포 및 비산배출 특성)

  • Park, Jeong-Ho;Jang, Min-Jae;Kim, Hyoung-Kab
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.1
    • /
    • pp.30-37
    • /
    • 2016
  • Objectives: This study was performed to measure and evaluate the concentration, size distribution and fugitive emission of particulate matter from process operations at foundries. Methods: Particle matter was collected from three foundries, and samples were also collected from a background site for calculating the fugitive emission concentration of the foundries. For the collection of the samples, a Nanosampler cascade impactor was used. Results: The concentration of TSP in the samples collected from the three foundries was $0.675{\sim}1.222mg/m^3$, $PM_{10}$ was $0.525{\sim}1.018mg/m^3$ and $PM_{2.5}$ was $0.192{\sim}0.615mg/m^3$. The mass size distribution was bimodal or monomodal with maximum peak at two stage(size $2.5{\sim}10{\mu}m$). The mass median aerodynamic diameter(MMAD) was $1.80{\sim}3.98{\mu}m$. The fugitive emission concentration of TSP varies in the range of 0.65 to $1.21mg/m^3$, which exceeds the emission standard of fugitive dust($0.5mg/m^3$). Conclusions: Particle concentration and size is an important industrial hygiene factor to protect foundry workers. Furthermore, the presence of high emission of particulate pollutants has a significant negative impact on the ambient air of the study area. Therefore, it is important to improve both the process and prevention facility in oder to reduce particulate pollutants in foundries.

Exposure to Fine Particle along Different Commuting Routes in Urban Area of Fukuoka, Japan

  • Ma, Chang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.205-213
    • /
    • 2015
  • The objective of the current study was to assess the comparative risk associated with exposure to particulate matter (PM) while commuting via different public transport modes in Fukuoka, Japan. For the given routes and measuring days, a trip-maker carried a lightweight portable bag loaded the real-time measurement devices which take simultaneous measurement for size-fractioned particle number concentration, $PM_{2.5}$ mass concentration, and total suspended particle (TSP) collection. The results of the present study have shown significant differences between public transports as commuting modes in Fukuoka. The PM exposure levels on subway platform and inside subway train were overwhelmingly higher than those of other points on commuting route. The relative ratio between modes (i.e., the ratio of $PM_{2.5}$ inside subway to that inside bus) provides an idea for choosing a right commuting mode for our health. This study clearly provided evidence of the extremely high levels of iron exposure by subway uses compared to bus uses. The result of theoretically reconstructed mass concentration of $PM_{2.0-0.3}$ collected on subway platform suggests that the PM of underground subway will be associated with PM both generated in subway system and inleakaged from outdoor environment.

Dust Collecting Efficiency Using Cyclone Deduster in Weanned Piglet Building (자돈사에서의 사이크론 먼지제거기의 집진효율 분석)

  • 최희철;이덕수;권두중;강희설;유용희;송준익;성환후;김형호;천상석
    • Journal of Animal Environmental Science
    • /
    • v.9 no.1
    • /
    • pp.19-26
    • /
    • 2003
  • This study was carried out to investigate the collecting efficiency of cyclone deduster installed in weaned piglet building in third weeks of age. There are two peaks of high level of dust concentration in piglet house at the time of 09:00~10:00(5,322$\mu g/m^3$) and 19:00~20:00(6,763$\mu g/m^3$), but the peaks of dust concentration in the building used cyclone deduster was decreased to 3,614.8 and 2,229.5$\mu g/m^3$, respectively. Collecting efficiency of total suspended particulate(TSP), particulate matter less than 10$\mu\textrm{m}$(PM 10) and particulate matter less than 2.5$\mu\textrm{m}$(PM 2.5) in weaned piglet building used in cyclone deduster was 38.3%, 32.5, 21.8, respectively. Aerial dust in weaned piglet building by number basis in the range of 0.745~1.08$\mu\textrm{m}$ was 53.5%. But dust distribution over 10$\mu\textrm{m}$ in volume basis was 82.8% and 86.2%. Crude protein of dust was 25.9~32.7%, and it was higher than feed crude protein(22.0%). Heavy metal concentration of dust was also high level compare to that of feed.

  • PDF

Case Studies of Mass Concentration Variation in the Central-Southern Korean Peninsula Caused by Synoptic Scale Transport of Dust Storms

  • Kim, Hak-Sung;Cho, Jae-Hee
    • Journal of the Korean earth science society
    • /
    • v.40 no.4
    • /
    • pp.414-427
    • /
    • 2019
  • In East Asia, the long-range transport of dust storms originating from Mongolia and northern China affects airborne dust loadings over downwind areas in the southern Korean Peninsula. Since 1997, dust loading cases caused by dust storms have been observed using the thresholds of total suspended particles (TSP, ${\geq}250{\mu}g\;m^{-3}\;hr^{-1}$) and particulate matter less than $10{\mu}g$ ($PM_{10}$, ${\geq}190{\mu}g\;m^{-3}\;hr^{-1}$) in the central-southern Korean Peninsula. There were two dust loading cases that exceeded these thresholds in 2016 and three in 2017, which reflects the downward trend of the last twenty-one years in the central-southern Korean Peninsula. Furthermore, five other dust loading cases with mass concentrations lower than the thresholds were observed from 2016 to 2017. In the moderate dust loading cases exceeding the thresholds, a descending motion of cut-off lows below $45^{\circ}N$ and a southward trough at 500 hPa gpm isopleths intensified at the western ridge, and largely extended the surface high-pressure system over southeast China. Airborne dust loadings following pronounced north-westerlies in the forward side of the high-pressure system were transported to the surface of the central-southern Korean Peninsula. However, in slight dust loading cases lower than the thresholds, the restricted descending motion of cut-off lows over $45^{\circ}N$ and the southwestward trough at 500 hPa gpm isopleths intensified the zonal flow over the Korean Peninsula. Surface high- and low-pressure systems moved eastward from the source compared to moderate dust loading cases. Due to the zonal movement of dust storms traversing eastern China, slight dust loading cases were observed with relatively higher ratios of $PM_{2.5}/TSP$ and carbon monoxide (CO) in the central-southern Korean Peninsula.

Seasonal Dust Concentration and Characteristics of Windowless Broiler Building (무창 육계사의 계절별 먼지 농도와 특성 연구)

  • Choi H. C.;Yeon G. Y.;Song J. I.;Kang H. S.;Kwon D. J.;Yoo Y. H.;Barroga A. J.;Yang C. B.;Chun S. S.;Kim Y. K.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.3
    • /
    • pp.197-206
    • /
    • 2005
  • This study was carried out to investigate the concentration and characteristics of dust originating from windowless broiler building in each season. 12.0m width and 46m tenth with side wall height of 3.0m was investigated and capacity was 12,800 birds at a stock density of 23.2 birds per square meter. Dust concentrations in terms of total suspended particles (TSP), and particulate matter of sizes $10{\mu}m(PM10),\;2.5{\mu}m (PM2.5),\;and\;1{\mu}m(PM1)$ were measured at 30-minute intervals. On the basis of broiler age, the average dust concentration in summer in TSP as follows: 1,229 904.5 558.8 and $1,053{\mu}g/m^3$ on the broilers' first to fourth week of age, respectively. But during winter, the average dust concentration showed an increasing pattern, as follows: 465.4, 1,401, 4,497, 5,097 and $6,873{\mu}g/m^3$ on the broilers' first to fifth week of age, respectively. The maximum dust concentration of $11,132{\mu}g/m^3$ was observed on the fifth week. On a daily basis, the maximum dust concentration during summer was detected in early morning, and the minimum in the afternoon. The aerial dust particle size of $0.05\~0.35{\mu}m$ was the highest in number. But on volume basis, particle size of 16~99 un had the largest percentage in the broiler house. Crude protein of the dust $(42.8\~65.2\%)$, on dry matter basis, was higher than that $(20.5\~24.5\%)$ fed to the broilers. Heavy metal concentration of the dust also had high levels compared with that of the feed.

  • PDF

The Meteorological, Physical, and Chemical Characteristics of Aerosol during Haze Event in May 2003 (2003년 5월의 연무 관측시 에어로졸의 기상 · 물리 · 화학 특성)

  • Lim, Ju-Yeon;Chun, Young-Sin;Cho, Kyoung-Mi;Lee, Sang-Sam;Shin, Hye-Jung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.5
    • /
    • pp.697-711
    • /
    • 2004
  • Severe haze, mist, and fog phenomena occurred in the central part of Korea during 15~25 May 2003 resulted in poor visibility and air quality. When these phenomena occurred, Korean peninsula was under the effects of anticyclone. The atmosphere was stable, and wind speed was so weak. Under this meteorological conditions, air quality was worse and worse. The characteristics of aerosol in Seoul, Incheon, and Gosan (Jeju) during this period are investigated from the $PM_{10}$. TSP concentrations and aerosol number concentrations. Concentrations of $PM_{10}$ and TSP measured at KMA increased upto 176 and 230 J.${\mu}g/m^3$ on 22 May 2003, respectively. Aerosol number concentrations of size range from 0.82 to 6.06 ${\mu}m$ increased in Seoul on 17, 19, and 21~24 May 2003, and the concentrations of $NO_2$ and $SO_2$had maximum value of 0.165 ppm at Gwanak Mt. and 0.036 ppm at Guro-dong on 23 May 2003, respectively. Result from analysis on heavy metal elements showed high concentrations of Zn, Pb, Cr, Ni, Cu, and Cd during 20~24 May 2003. This event is examined by comprehensive analyses of synoptic weather conditions, satellite images, concentrations of suspended particles and air pollutants, and heavy metal elements.

Mass Concentration and Chemical Composition of $PM_{10} and PM_{2.5}$ in Iksan (익산지역 환경대기 중 $PM_{10} 및 PM_{2.5}$의 농도 및 화학조성)

  • 강공언;이종훈;김신도;양고수;김화옥
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.153-154
    • /
    • 2003
  • 최근 10년간 대기환경 개선대책으로 1차 오염물질인 이산화황과 총부유먼지(TSP)의 농도는 현저히 감소하고 있다. 그러나 자동차의 증가 등으로 미세먼지, 오존 둥 2차 대기오염물질의 오염도는 오히려 증가하고 있는 추세에 있다. 특히 미세먼지(PM$_{2.5}$)는 시정에 영향을 주어 체감오염도를 증가시킬 뿐만 아니라 PM$_{2.5}$ 내에 함유된 각종 유해물질과 중금속 등은 인체에 직접적인 영향을 주는 것으로 알려져 있다. (중략)(중략)

  • PDF