• Title/Summary/Keyword: TORSION

Search Result 1,218, Processing Time 0.048 seconds

STRESS DISTRIBUTION IN ESTHETIC ORTHODONTIC BRACKETS : AN ANALYSIS USING THE FINITE ELEMENT METHOD (유한요소 분석을 통한 심미적 교정 브라켓의 응력 및 구조분석에 관한 연구)

  • Lee, Won-You;An, Ju-Sam;Park, Young-Cheol;Park, Myeong-Kyun;Sohn, Hong-Bum;Jeong, Si-Dong
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.43-49
    • /
    • 1998
  • The aim of this study were to measure and compare the stress level on three type brackets and each other material (stainless steel, ceramic) with tipping and torquing forces by using the finite element analysis and to design biomechanically favorable brackets. For this study, three kinds of brackets were selected(A:Transcend-RMO, B:Signature-Unitek, C:PAW: plain archwire appliance-applied for a patent in Yonsei Udiversity). The slot size of bracket was 0.022inch and the size of archwire was 0.0175x0.025inch and taper shaped archwire was used in PAW. Loading force in tipping was 4.27N and torquing force was 32.858N applied by archwire torsion with 19.7degree and 11.3 degree in C type bracket. The conclusions were that (1) The finite element method proved to be a useful tool in the stress analysis of orthodontic bracket subjected to various forces. (2) With tipping, the stresses were concentrated at the gingival wall of the wire slot where it meets the mesial bracket surface and the incisal wall of the wire slot where it meets the distal bracket surface and with torquing, the stresses were concentrated at the junction of the gingival or incisal wall and base of the slot. (3) The maximum stress value was higher in torquing force than tipping force and therefore it is desirable to design on the basis of torquing force. (4) It was considered that the change in material might be affect on the diminish of stress value in the place of stess concentration. (5) The maximum stress value was highest on PAW bracket when the tipping and torquing force was applied and therefore it would be desirable to use mechanically favorable material on PAW bracket.

  • PDF

A study on accuracy and application of the implant torque controller used in dental clinic (임상에서 사용하고 있는 임플란트 토크조절기의 정확도와 적용에 관한 사용실태)

  • Joo, Young-Hun;Lee, Jin-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.197-205
    • /
    • 2011
  • Purpose: This study was to evaluate the accuracy of the implant torque controller used in dental clinics and to investigate whether it was applied appropriately. Materials and methods: Fifty dentists who work in dental clinics were enrolled in this study. Dental (implant) practice career, experience frequency of implant screw loosening and fracture, education of implant torque controller application and infection control methods were included in the survey. 25 Ncm and 30 Ncm of the tightening torque applied to the implant screw were measured by 50 clinicians. After measuring the torque value by using the torque controller, the torque mean according to where education about the implant torque controller was received was analyzed with independent t-test at the significance level of 0.05. Results: The torque controller used in private dental clinics showed 4.78% error ratio. When 50 dentists applied 25 Ncm to the implant screw was $29.0{\pm}8.4$ Ncm, and that in 30 Ncm was $34.3{\pm}9.1$ Ncm. Statistical significance was found between the group that was educated about implant torque application and the group that was not educated. Conclusion: During the prosthodontic treatment with implant, there was difference between actual applied torsion force and the amount torque controller indicated. Clinicians have to not only be well-informed about the accurate usage method of the torque controller, but also keep and manage the torque controller so as to maintain continuous and accurate torque values. Through this, it is considered to achieve clinical results to minimize problems of screw loosening or fracture.

Transmission Dose Estimation Algorithm for Tissue Deficit (조직 결손에 대한 투과선량 계산 알고리즘 보정)

  • Yun Hyong Geun;Chie Eui Kyu;Huh Soon Nyung;Lee Hyoung Koo;Woo Hong Gyun;Shin Kyo Chul;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.186-192
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry. In this study, previous algorithm for estimation of transmission dose was modified for use in cases with tissue deficit. Materials and Methods : The beam data was measured with flat solid phantom in various conditions of tissue deficit. New algorithm for correction of transmission dose for tissue deficit was developed by physical reasoning. The algorithm was tested in experimental settings with irregular contours mimicking breast cancer patients using multiple sheets of solid phantoms. Results : The correction algorithm for tissue deficit could accurately reflect the effect of tissue deficit with errors within ${\pm}1.0\%$ in most situations and within ${\pm}3.0\%$ in experimental settings with irregular contours mimicking breast cancer treatment set-up. Conclusion : Developed algorithm could accurately reflect the effect of tissue deficit and irregularly shaped body contour on transmission dosimetry.

Minimal Invasive Surgery: A National Survey of Its Members by the Korean Association of Pediatric Surgeons (최소 침습 수술: 대한소아외과학회 회원을 대상으로 한 전국조사)

  • Kim, Dae Yeon;Kim, I.S.;Kim, H.Y.;Nam, S.H.;Park, K.W.;Park, W.H.;Park, Y.J.;Park, J.H.;Park, J.Y.;Park, J.S.;Park, J.Y.;Boo, Y.J.;Seo, J.M.;Seol, J.Y.;Oh, J.T.;Lee, N.H.;Lee, M.D.;Jang, J.H.;Jung, K.H.;Jung, S.Y.;Jung, S.E.;Jung, S.M.;Jung, E.Y.;Jung, J.H.;Cho, M.J.;Choi, K.J.;Choi, S.J.N.;Choi, S.O.;Choi, S.H.;Choi, Y.M.;Hong, J.
    • Advances in pediatric surgery
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Minimal invasive surgery (MIS) has rapidly gained acceptance for the management of a wide variety of pediatric diseases. A questionnaire was sent to all members of the Korean Association of Pediatric Surgeons. Thirty one members (25.4%) took part in the survey that included data for the year 2012: demographic details, opinion regarding minimal invasive surgery and robotic surgery, spectrum of minimally invasive operations, and quantity of procedures. 48.4% of the respondents had more than 10 years experience, 35.5% less than 10 years experience, and 16.1 % had no experience. The respondents of the recommend MIS and perform MIS for surgical procedures are as follow; inguinal hernia (61.3%), simple appendicitis (87.1%), complicated appendicitis (80.6%), reduction of intussusceptions (83.9%), pyloromyotomy (90.3%), fundoplication (96.8%), biopsy and corrective surgery of Hirschsprung's disease (93.5%/90.3%), imperforate anus (77.4%), congenital diaphragmatic hernia (80.6%), and esophageal atresia (74.2%). The MIS procedures with more than 70% were lung resection (100%), cholecystectomy (100%), appendectomy (96.2%), ovarian torsion (86.7%), fundoplication (86.8%), hiatal hernia repair (82.6%), and splenectomy (71.4%). The MIS procedures with less than 30% were congenial diaphragmatic hernia reapir (29.6%), esophageal atresia (26.2%), correction of malroatation (24.4%), inguinal hernia repair (11.4%), anorectal malformation (6.8%), Kasai operation (3.6%).

Arterial Switch Operation in Patients with Intramural Coronary Artery: Early and Mid-term Results

  • Kim, Hyung-Tae;Sung, Si-Chan;Kim, Si-Ho;Chang, Yun-Hee;Ahn, Hyo-Yeong;Lee, Hyoung-Doo
    • Journal of Chest Surgery
    • /
    • v.44 no.2
    • /
    • pp.115-122
    • /
    • 2011
  • Background: The intramural coronary artery has been known as a risk factor for early death after an arterial switch operation (ASO). We reviewed the morphological characteristics and evaluated the early and mid-term results of ASO for patients with an intramural coronary artery. Materials and Methods: From March 1994 to September 15th 2010, 158 patients underwent ASO at Dong-A and Pusan National University Hospitals for repair of transposition of the great arteries and double outlet right ventricle. Among these patients, 14 patients (8.9%) had an intramural coronary artery. Mean age at operation was $13.4{\pm}10.2$ days (4 to 39 days) and mean body weight was $3.48{\pm}0.33$ kg (2.88 to 3.88 kg). All patients except one were male. Eight patients had TGA/IVS and 4 patients had an aortic arch anomaly. Two patients (14.3%) had side-by-side great artery relation, of whom one had an intramural right coronary artery and the other had an intramural left anterior descending coronary artery. Twelve patients had anterior-posterior relation, all of whom had an intramural left coronary artery (LCA). The aortocoronary flap technique was used in coronary transfer in 8 patients, of whom one patient required a switch to the individual coronary button technique 2 days after operation because of myocardial ischemia. An individual coronary button implantation technique was adopted in 6, of whom 2 patients required left subclavian artery free graft to LCA during the same operation due to LCA injury during coronary button mobilization and LCA torsion. Results: There was 1 operative death (7.1%), which occurred in the first patient in our series. This patient underwent an aortocoronary flap procedure for coronary transfer combining aortic arch repair. Overall operative mortality for 144 patients without an intramural coronary artery was 13.2% (19/144). There was no statistical difference in operative mortality between the patients with and without an intramural coronary artery (p>0.1). There was no late death. The mean follow-up duration was $52.1{\pm}43.0$ months (0.5 to 132 months). One patient who had a subclavian artery free graft required LCA stenting 6.5 years after surgery for LCA anastomotic site stenosis. No other surviving patient needed any intervention for coronary problems. All patients had normal ventricular function at latest echocardiography and were in NYHA class 1. Conclusion: The arterial switch operation in Transposition of Great Arteries or Double Outlet Right Ventricle patients with intramural coronary can be performed with low mortality; however, there is a high incidence of intraoperative or postoperative coronary problems, which can be managed with conversion to the individual coronary button technique and a bypass procedure using a left subclavian free graft. Both aortocoronary flap and individual coronary button implantation techniques for coronary transfer have excellent mid-term results.

Transmission Dose Estimation Algorithm for in vivo Dosimertry (투과선량을 이용한 생체내 (in vivo) 선량측정을 위한 알고리즘)

  • Yun, Hyong-Geun;Chie, Eui-Kyu;Huh, Soon-Nyung;Lee, Hyoung-Koo;Woo, Hong-Gyun;Shin, Kyo-Chul;Kim, Si-Yong;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.3
    • /
    • pp.147-154
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry of QA purpose. The objective of this study is to develope an algorithm for estimation of tumor dose using measured transmission dose for open radiation field. Materials and Methods : Transmission dose was measured with various field size (FS), phantom thickness (Tp), and phantom chamber distance (PCD) with a acrylic phantom for 6 MV and 10 MV X-ray. Source to chamber distance (SCD) was set to 150 cm. Measurement was conducted with a 0.6 co Farmer type ion chamber. Using measured data and regression analysis, an algorithm was developed lot estimation of expected reading of transmission dose. Accuracy of the algorithm was tested with flat solid phantom with various settings. Results : The algorithm consisted of quadratic function of log(A/P) (where A/P is area-perimeter ratio) and tertiary function of PCD. The algorithm could estimate dose with very high accuracy for open square field, with errors within ${\pm}0.5%$. For elongated radiation field, the errors were limited to ${\pm}1.0%$. Conclusion : The developed algorithm can accurately estimate the transmission dose in open radiation fields with various treatment settings.

Solution Structure of 21-Residue Peptide (Asp 84-Leu 104), Functional Site derived from $p16^{INK4A}$ ($p16^{INK4A}$ 단백질 활성부위(Asp 84-Leu 104)의 용액상 구조)

  • Lee, Ho-Jin;Ahn, In-Ae;Ro, Seonggu;Choi, Young-Sang;Yoon, Chang No;Lee, Kang-Bong
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.494-503
    • /
    • 2000
  • A 21-residue peptide corresponding to amino acids 84-104 of $p16^{INK4A}$, the tumor suppressor, has been synthesized and its structure was studied by Circular Dichroism, $^1H$ NMR spectroscopy and molecular modeling. A p16-derived peptide (84-104 amino acids) forming stable complex with CDK4 and CDK6 inhibits the ability of CDK4/6 to phosphorylate pRb in vitro, and blocks cell-cycle progression through G1/S phase as shown in the function of the full-length p16. Its NMR spectral data including NOEs, $^3J_{NH-H{\alpha}}$ coupling constants, $C_{\alpha}H$ chemical shift, the average amplitude of amide chemical shift oscillation and temperature coefficients indicate that the secondary structure of a p16-derived peptide is similar to that of the same region of full-length p16, which consists of helix-turn-helix structure. The 3-D distance geometry structure based on NOE-hased distance and torsion angle restraints is characterized by ${\gamma}$-turn conformation between residues $Gly^{89}-Leu^{91}$(${\varphi}_{i+1}=-79.8^{\circ}$, ${\varphi}_{i+1}=60.2^{\circ}$) as evidenced in a single crystal structure for the corresponding region of p18 or p19, but is undefined at both the N and C termini. This compact and rigid ${\gamma}$-turn region is considered to stabilize the structure of p16-derived peptide and serve as a site recognizing cyelin dependent kinase, and this well-defined ${\gamma}$-turn structure could be utilized for the design of anti-cancer drug candidates.

  • PDF

Results of Surgical Treatment of Patella Dislocation (슬개골 탈구의 수술적 치료 결과)

  • Kim, Hui Taek;Cho, Yoon Jae
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.2
    • /
    • pp.134-141
    • /
    • 2021
  • Purpose: Patellar dislocations have a range of causes. This study examined the results of treatment aimed at balancing soft tissues around the patella. Materials and Methods: Thirty-two patellar dislocations in 28 patients (21 females and seven males) were examined. The mean patient age at the time of surgery was 11.5 years, and the mean follow-up period was 4.6 years. Dislocations were 19 chronic, six habitual, six congenital, and one acute. Soft tissue balancing surgery included lateral capsular release, medial capsular plication, and inferolateral transfer of the vastus medialis obliquus. Medial transfer of the patellar tendon, partial strip of the rectus femoris and patella tendon, and distal femoral osteotomy were also performed selectively. The preoperative Q angle, femoral anteversion angle, tibial external rotation angle, tibial tubercle-trochlear groove distance (TT-TG distance), mechanical femoral-tibial angle, and femoral trochlear dysplasia according to Dejour were measured, and the pre- and postoperative Lysholm-Tegner scores were used to analyze the clinical results. Results: The mean preoperative Q angle, TT-TG distance, femoral anteversion angle, tibial external rotation angle, mechanical femoraltibia angle, and Lysholm-Tegner score were 9.3°, 15.5 mm, 25.6°, 30.4°, 3.0°, and 75.8, respectively. Eleven patients had systemic ligament laxity with a Beighton score of five or more. Twenty-two patients had femoral trochlear dysplasia: four type A (3 patients), 16 type B (15 patients), one type C (1 patient), and four type D (3 patients). Of the 32 cases, 28 were corrected successfully by the first operation. Of four cases of postoperative subluxation, three were corrected by the second operation, and one of them was corrected after a third operation. The last patient is currently being followed-up. The mean Lysholm-Tegner score improved to 85.6 after the operation. Conclusion: Correcting all the causes of patella dislocation simultaneously is difficult. Nevertheless, satisfactory outcomes were obtained with soft tissue balancing surgery around the patella and a corrective osteotomy for an abnormal mechanical axis of the femur-tibia and torsion.