• Title/Summary/Keyword: TOF(Time of flight)

Search Result 410, Processing Time 0.042 seconds

Time-of-flight(TOF) Sensors for Vehicle Safety (차량 안전용 비행 시간 측정(TOF) 센서)

  • Shin, Seong-Yoon;Cho, Seung-Pyo;Lee, Hyun-Chang;Shin, Kwang-Seong
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2022.07a
    • /
    • pp.631-632
    • /
    • 2022
  • 본 논문에서는 새로운 TOF 센서를 개발하고자한다. 첫째, 카메라의 화소값과 TOF의 센서의 거리값을 융합하도록 한다. 둘째, 객체의 점유 정보와 위치 정보를 제공하는 TOF 센서를 개발한다. 개발된 센서는 스쿨버스, 학원버스, 시내버스, 화물차(승용차 적용가능)에 적용 가능 하다.

  • PDF

Effect of Detector-Misalignment on TOF-PET Detector Performance (검출기 정렬 오차가 TOF-PET 검출기의 성능에 미치는 영향성 평가)

  • Yang, Jingyu;Kang, Jihoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.841-846
    • /
    • 2019
  • Effect of misalignment on the performance was evaluated for the development of time-of-flight(TOF)-PET detector. A pair of TOF-PET detector consists of Lutetium-yttrium oxyorthosilicate(LYSO) scintillation crystal with a volume of 3 mm × 3 mm × 20 mm and Geiger-mode avalanche photodiodes(GAPD) photo-sensor with a active area of 3.07 mm × 3.07 mm. Analog output signals from TOF-PET detector were sent to the pre-amplifier and then fed into the gain adjust circuit for achievement of gain homogeneity for each detector. The amplified signals were recorded and digitized by data acquisition system based on oscilloscope. The effect of the detector misalignment between LYSO and GAPD was examined for four different alignment offsets of 0.0 mm, 0.5 mm, 1.0 mm and 1.5 mm for a pair of TOF-PET detector. The photopeak position decreased from ~400 mV to ~250 mV with increasing detector misalignment. the energy resolution and time resolution were degraded from 11.6% to 16.2%, and from 477 ps to 632 ps, respectively. This study demonstrated that PET detector performance was degraded considerably depending on the detector misalignment, which would be a critical issue for the development of TOF-PET detector.

Estimation of the Axial Stress in High-Tension Bolt by Acoustoelastic Method (음탄성법을 이용한 고장력 볼트의 축응력 평가)

  • Chun, Hae-Hwa;Lee, Tae-Hoon;Jhang, Kyung-Young;Kim, Noh-Yu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.5
    • /
    • pp.285-290
    • /
    • 2006
  • The evaluation of clamping condition has been regarded as the main issue in the safety-maintenance of the clamped high-tension bolts. For this, this paper proposes a method to estimate the axial stress by measuring the TOF (Time-Of-Flight) of ultrasonic wave, which is based on the acoustoelasticity or the dependency of sound speed on the stress. In this method, however, the variation of sound speed within the range of stress induced under the field condition is very small, and thus the accuracy of the TOF measurement is important. We adopted the phase detection method using tone-burst ultrasonic wave to measure the precise TOF. In order to verify the usefulness of the proposed method experiments are carried out and the results were compared with the stress measured by the strain gage. The results show good agreement with each other, and from these we can conclude that the proposed method is highly useful fnr the evaluation of clamping condition in the clamped high-tension bolts.

An Assessment of the Usefulness of Time of Flight in Magnetic Resonance Angiography Covering the Aortic Arch

  • Yoo, Yeong-Jun;Choi, Sung-Hyun;Dong, Kyung-Rae;Ji, Yun-Sang;Choi, Ji-Won;Ryu, Jae-Kwang
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.325-332
    • /
    • 2018
  • Carotid angiography covering the aortic arch includes contrast-enhanced magnetic resonance angiography (CEA), which is applied to a large region and usually employs contrast media. However, the use of contrast media can be dangerous in infants, pregnant women, and patients with chronic renal failure (CRF). Follow-up patients informed of a lesion may also want to avoid constant exposure to contrast media. We aimed to apply time-of-flight (TOF) angiography to a large region and compare its usefulness with that of CEA. Ten patients (mean age, 58 years; range, 45~75 years) who visited our hospital for magnetic resonance angiography (MRA) participated in this study. A 3.0 Tesla Achieva magnetic resonance imaging (MRI) system (Philips, Netherland) and the SENSE NeuroVascular 16-channel coil were employed for both methods. Both methods were applied simultaneously to the same patient. Three TOF stacks were connected to cover the aortic arch through the circle of Willis, and CEA was applied in the same manner. For the quantitative assessment, the acquired images were used to set the regions of interest (ROIs) in the common carotid artery (CCA) bifurcation, internal carotid artery, external carotid artery, middle cerebral artery, and vertebral artery, and to obtain the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) for the soft tissues. Three radiologists and one radiological resident performed the qualitative assessment on a 5-point scale - 1 point, "very bad"; 2 points, "bad"; 3 points, "average"; 4 points, "good"; and 5 points, "very good" - with regard to 4 items: (1) sharpness, (2) distortion, (3) vein contamination, and (4) expression of peripheral vessels. For the quantitative assessment, we estimated the mean SNR and CNR in each of the 5 ROIs. In general, the mean SNR was higher in TOF angiography (166.1, 205.2, 154.39, 172.23, and 161.95) than in CEA(92.05, 95.43, 84.76, 73.69, and 88.3). Both methods had a similar mean CNR: 67.62, 106.71, 55.9, 73.74, and 63.46 for TOF angiography, and 67.82, 71.19, 60.52, 49.45, and 64.07 for CEA. In all ROIs, the mean SNR was statistically significant (p<0.05), whereas the mean CNR was insignificant (p>0.05). The mean values of TOF angiography and CEA for each item in the qualitative assessment were 4.2 and 4.28, respectively for item 1; 2.93 and 4.55, respectively, for item 2; 4.6 and 3.13, respectively, for item 3; and 2.88 and 4.65, respectively, for item 4. Therefore, TOF angiography had a higher mean for item 3, and CEA had a higher mean for items 2 and 4; there was no significant difference between the two methods for item 1. The results for item 1 were statistically insignificant (p>0.05), whereas the results for items 2~4 were statistically significant (p<0.05). Both methods have advantages and disadvantages and they complement each other. However, CEA is usually applied to a large region covering the aortic arch. Time-of-flight angiography may be useful for people such as infants, pregnant women, CRF patients, and followup patients for whom the use of contrast media can be dangerous or unnecessary, depending on the circumstance.

Nano Bio Imaging for NT and BT

  • Moon, DaeWon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.51.2-51.2
    • /
    • 2015
  • Understanding interfacial phenomena has been one of the main research issues not only in semiconductors but only in life sciences. I have been trying to meet the atomic scale surface and interface analysis challenges from semiconductor industries and furthermore to extend the application scope to biomedical areas. Optical imaing has been most widely and successfully used for biomedical imaging but complementary ion beam imaging techniques based on mass spectrometry and ion scattering can provide more detailed molecular specific and nanoscale information In this presentation, I will review the 27 years history of medium energy ion scattering (MEIS) development at KRISS and DGIST for nanoanalysis. A electrostatic MEIS system constructed at KRISS after the FOM, Netherland design had been successfully applied for the gate oxide analysis and quantitative surface analysis. Recenlty, we developed time-of-flight (TOF) MEIS system, for the first time in the world. With TOF-MEIS, we reported quantitative compositional profiling with single atomic layer resolution for 0.5~3 nm CdSe/ZnS conjugated QDs and ultra shallow junctions and FINFET's of As implanted Si. With this new TOF-MEIS nano analysis technique, details of nano-structured materials could be measured quantitatively. Progresses in TOF-MEIS analysis in various nano & bio technology will be discussed. For last 10 years, I have been trying to develop multimodal nanobio imaging techniques for cardiovascular and brain tissues. Firstly, in atherosclerotic plaque imaging, using, coherent anti-stokes raman scattering (CARS) and time-of-flight secondary ion mass spectrometry (TOF-SIMS) multimodal analysis showed that increased cholesterol palmitate may contribute to the formation of a necrotic core by increasing cell death. Secondly, surface plasmon resonance imaging ellipsometry (SPRIE) was developed for cell biointerface imaging of cell adhesion, migration, and infiltration dynamics for HUVEC, CASMC, and T cells. Thirdly, we developed an ambient mass spectrometric imaging system for live cells and tissues. Preliminary results on mouse brain hippocampus and hypotahlamus will be presented. In conclusions, multimodal optical and mass spectrometric imaging privides overall structural and morphological information with complementary molecular specific information, which can be a useful methodology for biomedical studies. Future challenges in optical and mass spectrometric imaging for new biomedical applications will be discussed.

  • PDF

Four Dimension(4D) Time Resolved Imaging of Contrast Kinetics(TRICKS) MR Angiography (4차원 영상기법 Time Resolved Imaging of Contrast Kinetics MRA의 유용성)

  • Lim, cheong-hwan;Bae, sung-jin
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1105-1110
    • /
    • 2009
  • To assess the clinical value of time resolved imaging of contrast kinetics(TRICKS) MRA by comparison with conventional time of flight(TOF) MR angiography. Both TOF-MRA and TRICKS-MRA were performed in 17 patients with cerebrovascular disease and in 6 patients with brain tumor. Among 17 cerebraovascular patients, digital subtraction angiography(DSA) data were also obtained in 11 patients. TOF-MRA showed good spatial resolution but short in temporal resolution. Although TRICKS-MRA showed somewhat low spatial resolution, it showed superior temporal resolution by distinguishing vessel and tumor in all patients. Also, from the analysis of vessel-tumor relationship, TRICKS-MRA showed better performance than TOF-MRA. TRICKS-MRA makes it possible to image arterial, capillary and venous phase sequentially with very speedy manner and therefore, the clinical use of this method is highly suggestive for future use.

  • PDF

Autostereoscopic 3D display system with moving parallax barrier and eye-tracking (이동형 패럴랙스배리어와 시점 추적을 이용한 3D 디스플레이 시스템)

  • Chae, Ho-Byung;Ryu, Young-Roc;Lee, Gang-Sung;Lee, Seung-Hyun
    • Journal of Broadcast Engineering
    • /
    • v.14 no.4
    • /
    • pp.419-427
    • /
    • 2009
  • We present a novel head tracking system for stereoscopic displays that ensures the viewer has a high degree of movement. The tracker is capable of segmenting the viewer from background objects using their relative distance. A depth camera using TOF(Time-Of-Flight) is used to generate a key signal for eye tracking application. A method of the moving parallax barrier is also introduced to supplement a disadvantage of the fixed parallax barrier that provides observation at the specific locations.

NanoAnalysis with TOF-MEIS (TOF-MEIS 나노분석법)

  • Yu, Kyu-Sang;Moon, DaeWon
    • Vacuum Magazine
    • /
    • v.2 no.2
    • /
    • pp.17-23
    • /
    • 2015
  • Medium Energy Ion Scattering (MEIS) has been successfully used for ultrathin film analysis such as gate oxides and multilayers due to its single atomic depth resolution in compostional and structural depth profiling. Recently, we developed a time-of-flight (TOF) MEIS for the first time, which can analyze a $10{\mu}m$ small spot. Small spot analysis would be useful for test pattern analysis in semiconductor industry and various thin film technology. The ion beam damage problem is minimized due to its improved collection efficiency by orders of magnitude and the ion beam neutralization problem is removed completely for quantitative analysis. Newly developed TOF-MEIS has been applied for gate oxides, ultra shallow junctions, nanoparticles, FINFET structures to provide compositional and structural profiles. Further development for submicron spot analysis and applications for functional nano thin films and nanostructured materials are expected for various nanotechnology and biotehnology.

Link Performance of an CDMA-Based Time-of-Flight Ranging by Using LED Visible Light

  • Wang, Yang;Liang, Chengchao;Su, Xin;Chang, KyungHi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37A no.10
    • /
    • pp.834-840
    • /
    • 2012
  • The use of ranging sensors on automobiles is becoming common with the desire of traffic safety by providing drivers the information of the relative distance between the vehicles. In this paper, the LED visible light ranging system different from the conventional ranging systems using the RF signal is investigated. For such a system, we propose a novel ranging algorithm which combines the time-of-flight (TOF) with the CDMA technology. Via the CDMA technology, the TOF ranging system can accurately distinguish the desired ranging signal from the visible light interferences of the neighbor vehicles. In addition, the proposed system can also overcome the light noise from other luminaries, i.e. sun-light, traffic-light, and so on. The simulation results show that the CDMA-based LED ranging system has a significant improvement for the ranging accuracy compared with the case without employing the CDMA.

FPGA Implementation of Differential CORDIC-based high-speed phase calculator for 3D Depth Image Extraction (3차원 Depth Image 추출용 Differential CORDIC 기반 고속 위상 연산기의 FPGA 구현)

  • Koo, Jung-youn;Shin, Kyung-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.350-353
    • /
    • 2013
  • In this paper, a hardware implementation of phase calculator for extracting 3D depth image from TOF(Time-Of-Flight) sensor is proposed. The designed phase calculator, which adopts redundant binary number systems and a pipelined architecture to improve throughput and speed, performs arctangent operation using vectoring mode of DCORDIC algorithm. Fixed-point MATLAB simulations are carried out to determine the optimized bit-widths and number of iteration. The designed phase calculator is verified by emulating the restoration of virtual 3D data using MATLAB/Simulink and FPGA-in-the-loop verification, and the estimated performance is about 7.5 Gbps at 469 MHz clock frequency.

  • PDF