Pattern Recognition Improvement of an Ultrasonic Sensor System Using Neuro-Fuzzy Signal Processing (초음파센서 시스템의 패턴인식 개선을 위한 뉴로퍼지 신호처리)

  • Na, Seung-You;Park, Min-Sang
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.12
    • /
    • pp.17-26
    • /
    • 1998
  • Ultrasonic sensors are widely used in various applications due to advantages of low cost, simplicity in construction, mechanical robustness, and little environmental restriction in usage. But for the application of object recognition, ultrasonic sensors exhibit several shortcomings of poor directionality which results in low spatial resolution of objects, and specularity which gives frequent erroneous range readings. The time-of-flight(TOF) method generally used for distance measurement can not distinguish small object patterns of plane, corner or edge. To resolve the problem, an increased number of the sensors in the forms of a linear array or 2-dimensional array of the sensors has been used. Also better resolution has been obtained by shifting the array in several steps using mechanical actuators. Also simple patterns are classified based on analyzing signal reflections. In this paper we propose a method of a sensor array system with improved capability in pattern distinction using electronic circuits accompanying the sensor array, and intelligent algorithm based on neuro-fuzzy processing of data fusion. The circuit changes transmitter output voltages of array elements in several steps. A set of different return signals from neighborhood sensors is manipulated to provide enhanced pattern recognition in the aspects of inclination angle, size and shift as well as distance of objects. The results show improved resolution of the measurements for smaller targets.

  • PDF

Characterization of submicron Particles Using a Single Particle Mass Spectrometer(I) - Non - Linear Correlation Between Particle Size and Mass Spectra Signals - (단일입자 질량분석기를 애용한 서브마이크론 입자의 특성화(I) - 입자의 크기와 질량분광신호의 비선형성 -)

  • Zachariah Michael R.;Lee Donggeun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.4 s.235
    • /
    • pp.453-459
    • /
    • 2005
  • In this paper, we are proposing a robust tool which is capable of measuring the size and elemental composition of submicron particles from twenty to several hundreds nanometers at the same time, i.e., named Single Particle Mass Spectrometer (SPMS). The home-made SPMS employs a laser ablation/multi-photon ionization method to tear a nanoparticle into the constituent elemental ions. One thing different from the conventional Aerosol Time-of-Flight Mass Spectrometer (ATOFMS) is the power of the ionization laser. Much strong laser used in this work makes it possible to generate elemental ions rather than molecular ions from a nanoparticle. Also the use of high power laser may guarantee a complete ionization of a particle, which was confirmed by the existence of multiple charged ions. If a particle is evaporated/ionized completely and detected through electric field-free TOF tube without any loss, we can extract the original particle volume from the measured total ion numbers. Collecting a number of particles mass spectra, we get a database of size and elemental composition of nanoparticles, with which we may take a took into any kinds of chemical reaction occurring at nanoscale. Several issues related to size estimation by SPMS will be discussed.

Ultrasonic Flaw Detection in Composite Materials Using SSP-MPSD Algorithm

  • Benammar, Abdessalem;Drai, Redouane
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1753-1761
    • /
    • 2014
  • Due to the inherent inhomogeneous and anisotropy nature of the composite materials, the detection of internal defects in these materials with non-destructive techniques is an important requirement both for quality checks during the production phase and in service inspection during maintenance operations. The estimation of the time-of-arrival (TOA) and/or time-of-flight (TOF) of the ultrasonic echoes is essential in ultrasonic non-destructive testing (NDT). In this paper, we used split-spectrum processing (SSP) combined with matching pursuit signal decomposition (MPSD) to develop a dedicated ultrasonic detection system. SSP algorithm is used for Signal-to-Noise Ratio (SNR) enhancement, and the MPSD algorithm is used to decompose backscattered signals into a linear expansion of chirplet echoes and estimate the chirplet parameters. Therefore, the combination of SSP and MPSD (SSP-MPSD) presents a powerful technique for ultrasonic NDT. The SSP algorithm is achieved by using Gaussian band pass filters. Then, MPSD algorithm uses the Maximum Likelihood Estimation. The good performance of the proposed method is experimentally verified using ultrasonic traces acquired from three specimens of carbon fibre reinforced polymer multi-layered composite materials (CFRP).

The analysis of the electron drift velocity of Xenon gas by Boltzmann-equation (볼츠만 방정식을 이용한 Xe 가스의 전자 이동속도 해석)

  • Song, Byoung-Doo;Ha, Sung-Chul;Jeon, Byoung-Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.201-203
    • /
    • 2001
  • This paper describes the information for quantitative simulation of weakly ionized plasma. We must grasp the meaning of the plasma state condition to utilize engineering application and to understand materials of plasma state. In this paper, the drift velocity of electron in Xenon gas calculated for range of E/N values from 0.01~500[Td] at the temperature is $300[^{\circ}K]$ and pressure is 1[Torr], using a set of electron collision cross sections determined by the authors and the values of drift velocity of electrons are obtained for TOF, PT, SST sampling method of Backward Prolongation by two term approximation Boltzmann equation method. it has also been used to predict swarm parameter using the values of cross section as input. The result of Boltzmann equation, the drift velocity of electrons, has been compared with experimental data by L. S. Frost and A. V. Phelps for a range of E/N. The swarm parameter from the study are expected to server as a critical test of current theories of low energy scattering by atoms and molecules.

  • PDF

A Simple and Rapid Method to Isolate Low Molecular Weight Proteinase Inhibitors from Soybean

  • Krishnan Bari B.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.49 no.4
    • /
    • pp.342-348
    • /
    • 2004
  • Sodium dodecyl sulfate-polyacrylamide gel electrophoresis of the $60\%$ isopropanol extract of soybean(Glycine max [L.] Merr.) seed revealed two abundant proteins with molecular masses of 19 and 10 kDa. Amino acid analysis revealed that the isopropanol-extractable protein fraction was rich in cysteine. Two-dimensional gel electro-phoretic analysis indicated that the 19kDa and 10kDa proteins had pI of 4.2 and 4.0 respectively. Peptide mass fingerprints of trypsin digests of the two proteins obtained using matrix-assisted, laser desorption/ionization-time of flight (MALDI-TOF) mass spectroscopy revealed the 19kDa protein was Kunitz trypsin inhibitor and the 10kDa protein was Bowman-Birk proteinase inhibitor. When resolved under non-denaturing conditions, the isopropanol-extracted proteins inhibited trypsin and chymotrypsin activity. Results presented in this study demonstrate that isopropanol extraction of soybean seed could be used as a simple and rapid method to obtain a protein fraction enriched in Kunitz trypsin and Bowman-Birk proteinase inhibitors. Since proteinase inhibitors are rich in sulfur amino acids and are putative anticarcinogens, this rapid and inexpensive isolation procedure could facilitate efforts in nutrition and cancer research.

Diffusion Coefficients in $SF_6-Ar$ Gas used by MCS-BE Algorithm (MCS-BEq 알고리즘에 의한 $SF_6-Ar$ 혼합기체의 확산계수)

  • Kim, Sang-Nam
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.298-301
    • /
    • 2006
  • This paper describes the electron energy distribution function characteristics in $SF_6-Ar$ gas calculated for range of E/N values from $50\sim700[Td]$ by the Monte Carlo simulation(MCS) and Boltzmann equation(BE) method using a set of electron collision cross sections determined by the authors and the values of electron swarm parameters are obtained by time of flight(TOF) method. In this dissertation the results of the combined experimental and theoretical studies designed to understand and predict the spatial growth and transport coefficients for electrons in $SF_6$ and $SF_6-Ar$ mixtures have described. The ionization and attachment coefficients in pure $SF_6$ and $SF_6-Ar$ mixtures have been calculated over the range of 10$SF_6$ molecule and for Ar atom proposed by other authors. The results obtained in this work will provide valuable information on the fundamental behaviors of electrons in weakly ionized gases and the role of electron attachment in the choice of better gases and unitary gas dielectrics or electro negative components in dielectric gas mixtures.

  • PDF

Biomarkers Screening Between Preoperative and Postoperative Patients in Pancreatic Cancer

  • Li, Pei;Yang, Juan;Ma, Qing-Yong;Wu, Zheng;Huang, Chen;Li, Xu-Qi;Wang, Zheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.7
    • /
    • pp.4161-4165
    • /
    • 2013
  • Objective: To investigate discriminating protein patterns and potential biomarkers in serum samples between pre/postoperative pancreatic cancer patients and healthy controls. Methods: 23 serum samples from PC patients (12 preoperative and 11 postoperative) and 76 from healthy controls were analyzed using matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) technique combined with magnetic beads-based weak cation-exchange chromatography (MB-WCX). ClinProTools software selected several markers that made a distinction between pancreatic cancer patients and healthy controls. Results: 49 m/z distinctive peaks were found among the three groups, of which 33 significant peaks with a P < 0.001 were detected. Two proteins could distinguish the preoperative pancreatic cancer patients from the healthy controls. About 15 proteins may be potential biomarkers in assessment of pancreatic cancer resection. Conclusion: MB-MALDI-TOF-MS method could generate serum peptidome profiles of pancreatic cancer and provide a new approach to identify potential biomarkers for diagnosis and prognosis of this malignancy.

Virtual View-point Depth Image Synthesis System for CGH (CGH를 위한 가상시점 깊이영상 합성 시스템)

  • Kim, Taek-Beom;Ko, Min-Soo;Yoo, Ji-Sang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.7
    • /
    • pp.1477-1486
    • /
    • 2012
  • In this paper, we propose Multi-view CGH Making System using method of generation of virtual view-point depth image. We acquire reliable depth image using TOF depth camera. We extract parameters of reference-view cameras. Once the position of camera of virtual view-point is defined, select optimal reference-view cameras considering position of it and distance between it and virtual view-point camera. Setting a reference-view camera whose position is reverse of primary reference-view camera as sub reference-view, we generate depth image of virtual view-point. And we compensate occlusion boundaries of virtual view-point depth image using depth image of sub reference-view. In this step, remaining hole boundaries are compensated with minimum values of neighborhood. And then, we generate final depth image of virtual view-point. Finally, using result of depth image from these steps, we generate CGH. The experimental results show that the proposed algorithm performs much better than conventional algorithms.

Characterization of Acetylene Plasma-Polymer Films: Recovery of Surface Hydrophobicity by Aging

  • Kim, Jeong-Ho;Kim, Tae-Hyung;Oh, Jung-Geun;Noh, Seok-Hwan;Lee, Jeong-Soo;Park, Kyu-Ho;Ha, Sam-Chul;Kang, Heon
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.11
    • /
    • pp.2589-2594
    • /
    • 2009
  • Aging phenomena of plasma polymer films were studied by using the surface analysis techniques of contact angle measurement, X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (TOFSIMS), and atomic force microscopy (AFM). The polymer films were grown on an aluminum substrate by using a plasma polymerization method from a gas mixture of acetylene and helium, and the films were subsequently modified to have a hydrophilic surface by oxygen plasma treatment. Aging of the polymer films was examined by exposing the samples to water and air environments. The aging process increased the hydrophobicity of the surface, as revealed by an increase in the advancing contact angle of water. XPS analysis showed that the population of oxygen-containing polar groups increased due to the uptake of oxygen during the aging, whereas TOF-SIMS analysis revealed a decrease in the polar group population in the uppermost surface layer. The results suggest that the change in surface property from hydrophilic to hydrophobic nature results from the restructuring of polymer chains near the surface, rather than compositional change of the surface. Oxidative degradation may enhance the mobility and the restructuring process of polymer chains.

A Development of Ultrasonic Based Distance Meter Through Detachment of Receiving and Transmitting Capacitive Ultrasonic Transducer (송.수신 분리형 초음파 거리 측정기 개발)

  • Kim Jung-Hoon;Chong Jong-Wha
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.3 s.309
    • /
    • pp.41-50
    • /
    • 2006
  • This paper presents a novel ultrasonic sensor system to overcome limited distance detection range that can be measured only more than 30cm by single ultrasonic transducer. This is accomplished by separation of receiving capacitive ultrasonic transducer from transmitting capacitive ultrasonic transducer. And hardwares and software of the system are described in detail. The system makes very close range as well as long range detect by wireless precisely. Frequency of trigger pulse is 10Hz, but it is very low frequency for transmitting data in wireless module. Therefore, for triggering between receiver and transmitter, an algorithm for mixing and distinguishing trigger pulse from carrier pulse by software is proposed. The system is designed by common microprocessor 8051. The performance of the proposed method has been assessed through two types. The first, transmitting and receiving transducer are put on both sides. And then, distance of two point is measured as far as 0mm. Secondly, transmitting transducer send out ultrasonic pulse and measure the time of flight(TOF) until a first echo from an object detected by the detached receiving transducer. The distance between the detached transducers and a reflecting object is measured as far as 7cm. Images of measured ultrasonic waves and TOF for two methods presented to prove effectiveness of results.