• Title/Summary/Keyword: TOC removal

Search Result 220, Processing Time 0.021 seconds

Characteristics of Non-biodegradable Substances in Landfill Leachate (매립장 침출수의 생물학적 난분해성물질 특성 규명)

  • Lim, Bong-Su;Park, Hye-Sook;Kim, Heung Rag
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.484-489
    • /
    • 2005
  • In order to determine the removal rate of non-biodegradable substances and the change of their structural properties, this study was carried out by an ozone-treatment experiment on leachate collected from the landfill area of D City in Chung chung nam-do and examined the change of the chemical properties of non-biodegradable substances. The main elements of non-biodegradable substances in landfill leachate were benzene, toluene, trichloroethane, trichloroethylene, xylene, etc. and the concentration of toluene was 15.7 mg/L on the average, benzene 7.2 mg/L, trichloroethane 1.1 mg/L, trichloroethylene 0.75 mg/L and xylene 0.5 mg/L. When leachate was treated with ozone for 10 min, 30 min and 60 min, UV absorbance was reduced with the increase of reaction time, and the reduction rate was 38.6% at 60 min. TOC was removed by 13.2% at 60 min. The low reduction rate of TOC may be because TOC reacts indirectly with OH radical produced from reaction with ozone while UV absorbance usually relies on direct reaction between organic matters and ozone molecules. Color was removed by up to 97%, which suggests that ozonation is highly effective in removing coloring elements in leachate. Sixteen kinds of non-biodegradable compounds were found in the leachate and most of them had the characteristic of aromatic hydrocarbon. Among them dibutyl phthalate was identical with a substance included in the list of US EPA, which is classified as a mutagen that may cause the mutation of genes and disorders in chromosomes. In addition, 2,5-Cyclohexadiene-1,4-dione, 1,2-Benzenedicarboxylic acid and butyl octyl ester were found to be similar to substances listed by USEPA. According to the result of analyzing structural changes before and after ozonation using GC-MS, cyclic compounds and aromatic compounds were observed in the original water and aliphatic compounds were newly observed after ozonation. In addition, through ozonation, humic substances of high molecular weight were oxidized and decomposed and produced low-molecular compounds such as aldehyde, ketone and carboxyl acid and highly biodegradable aliphatic carbon, which suggests the bio-degradability of non-biodegradable substances.

Design Parameters of Sequencing Batch Reactor treating ship sewage (연속 회분식 공정(SBR)을 이용한 선박 오 ${\cdot}$ 폐수처리 설계인자 도출)

  • Park, Sang-Ho;Kim, In-Soo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.29 no.1
    • /
    • pp.293-298
    • /
    • 2005
  • Lab scale experimental study was carried out for SBR process, to investigate the effects of influent ship sewage organic compound removal and Bacillus sp. state on design parameters. This process was able to remove nitrogen and phosphorus as well as organic matter efficiently. More than 95% of chemical oxygen demand(COD) were removed. In addition, about 97% of total nitrogen (T-N) was reduced. The total phosphorus(T-P) reduction averaged 93%. The performance load of SBR process was shown to be 0.095kg ${\cdot}$ TOC/$m^{3}$ ${\cdot}$ day. The pH was decreased from 8.1 to 7.0 within 30 min and increased to 7.3 at the end of anoxic stage, and these phenomena were explained. The sluge produced in the SBR process is characterized by low generation rate (about 0.36kg ${\cdot}$ MLSS/kg ${\cdot}$ TOC) and excellent settleability. The number of Bacillus sp. in the SBR was 24.2%, indicating that Bacillus sp. was a predominant species in the reactor.

  • PDF

Advanced Wastewater Treatment using Sequencing Batch Reactor on ship's sewage (연속 회분식 공정(SBR)을 이용한 선박 오·폐수의 고도처리)

  • Park Sang-Ho;Kim In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.29 no.5 s.101
    • /
    • pp.475-480
    • /
    • 2005
  • Lab scale experimental study was carried out for SBR process, to investigate the effects of influent ship sewage organic compound removal and Bacillus sp. state on design parameters. This process was able to remove nitrogen and phosphorus as well as organic matter efficiently. More than $92.0\%$ of chemical oxygen demand(COD) were removed. In addition, about $84.0\%$ of total nitrogen (T-N) was reduced. The total phosphorus(T-P) reduction averaged $93\%$. The performance load of SBR process was shown to be $0.095kg{\cdot}TOC/m3{\cdot}day$. The pH was decreased from 8.1 to 7.0 within 30 min and increased to 7.3 at the end of anoxic stage, and these phenomena were explained. The sludge produced in the SBR process is characterized by low generation rate (about $0.36kg{\cdot}MLSS/kg{\cdot}TOC$) and excellent settleability. The number of Bacillus sp. in the SBR was $24.2\%$, indicating that Bacillus sp. was a predominant species in the reactor.

Comparative Studies Of the $UV/H_2O_2,\;UV/TiO_2/H_2O_2$ and Photo-Fenton Oxidation for Degradation of Citric Acid ($UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton 산화방법에 의한 Citric Acid의 분해효율 비교)

  • Seo, Min-Hye;Cho, Soon-Haing;Ha, Dong-Yun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.4
    • /
    • pp.429-437
    • /
    • 2006
  • To establish the efficient treatment technology of chemical cleaning wastewater from power plant, several AOPs($UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton oxidation) were investigated. Treatment efficiencies and the electrical energy requirements based on the EE/O parameter(the electrical energy, required per order of pollutant removal in $1m^3$ wastewater) were evaluated. TOC removal efficiencies of $UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton oxidation at the optimum conditions were 95.5%, 92.3%, 91.5%, respectively. The electrical energy requirements of $UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton oxidation were $11.26kWh/m^3,\;3.85kWh/m^3,\;0.799kWh/m^3$, respectively. From these results, it could be concluded that all of the three oxidation processes were effective for the degradation of citric acid. Considering the treatment efficiency and economical aspect, photo-Fenton oxidation was the most efficient treatment process among the three processes tested.

Removal Characteristics of Phenol at Advanced Oxidation Process with Ozone/Activated Carbon Impregnated Metals (오존/촉매 산화공정에서 금속담지 활성탄을 이용한 페놀의 분해 특성)

  • Choi, Jae Won;Yoon, Ji Young;Park, Jin Do;Lee, Hak Sung
    • Applied Chemistry for Engineering
    • /
    • v.23 no.3
    • /
    • pp.302-307
    • /
    • 2012
  • Advanced oxidation processes (AOP) such as O3/activated carbon process and O3/catalysts process were used to compare the decomposition of phenol. Catalysts such as Pd/activated carbon (Pd/AC), Mn/activated carbon (Mn/AC), Co/activated carbon (Co/AC) and Fe/activated carbon (Fe/AC) were prepared by impregnation of Pd, Mn, Co and Fe into the activated carbon of pellet form, respectively. Based on an hour of reactions, the following descending order for the decomposition ratios of dissolved O3 to the 1.48 mg/L of saturated dissolved O3 was observed: Mn/AC (45%) > Pd/AC (42%) > Co/AC (33%) > AC (31%) > Fe/AC (27%). The removal efficiencies of phenol were also arranged in the descending order of AOP as follows: Mn/AC (89%) > Pd/AC (85%) > Co/AC (77%) > AC (76%) > Fe/AC (71%). The remaining ratios (C/Co) of TOC (total organic carbon) after an hour of experiments were arranged in the ascending order of AOP as follows : Pd/AC (0.29) < Mn/AC (0.36) < AC (0.40) < Co/AC (0.49) < Fe/AC (0.51). However, the catalytic effects in the Co/AC and the Fe/AC processes were little in comparison with O3/AC process. The maximum concentrations of intermediates such as hydroquinone and catechol formed from the decomposition of phenol were arranged in the ascending order of AOP as follows: Pd/AC < Fe/AC < Co/AC < AC < Mn/AC. In the case of Pd/AC process, these intermediates were almost disappeared after an one hour of reaction.

The wastewater treatment system with high performance based on electrochemical interface reaction using dimensionally stable anode with simple manufacturing (전기화학 계면반응에 기초한 DSA 전극을 사용한 고성능 폐수처리 시스템)

  • Na, Young Soo;Lee, Man Sung;Kim, Kyoungho
    • Journal of Adhesion and Interface
    • /
    • v.19 no.3
    • /
    • pp.101-105
    • /
    • 2018
  • With the rapidly growing of the population and industrization of cities, the clean and affordable water resources have gained immense interest because of remaining about 780 million people still lack access to it. However, present wastewater treatment systems have been faced with various issues, such as low processing efficiency, high operational costs and the requirement of a large area for manufacturing. It is therefore urgently required to develop an inexpensive and efficient wastewater treatment system. As the one of these efforts, we suggested and successfully demonstrated the wastewater treatment system using and electrochemical method via a dimensionally stable anode (DSA) based on rutile type $RuO_2$. Our system achieved biochemical oxygen demand (BOD), chemical oxygen demand (COD), and total organic carbon (TOC) removal efficiently at the respective rates of 52.0%, 77.8%, and 65.6% from household wastewater. In addition, we were able to remove BOD, COD, total nitrogen (TN), and total phosphorus (TP) from animal husbandry wastewater at rates of 92.9%, 75.6%, 35.1%, and 100%, respectively, thereby achieving dramatic reductions. Considering the excellent removal efficiency and the small size of this device, electrochemical wastewater treatment using a DSA coated in rutile $RuO_2$ presents a promising option for the treatment of both household and animal husbandry wastewater.

Performance Evaluation of MF Membrane Filtration Pilot System Associated with Pre Coagulation-Sedimentation with Iron-Based Coagulant and Chlorination Treatment (철염계 응집제를 사용한 전응집침전, 전염소처리와 PVDF 재질의 정밀여과 막을 조합한 막 여과 정수처리시스템 평가에 관한 연구)

  • Lee, Sanghyup;Jang, Nakyong;Yoshimasa, Watanabe;Choi, Yongsu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.588-597
    • /
    • 2004
  • In this research, we investigated the variation of transmembrane pressure and permeate water quality with pre coagulation and sedimentation with iron based coagulant and chlorination of feed water for PVDF (polyvinylidene fluoride) based MF membrane filtration. NaCIO was fed to the membrane module with dosage of 0.5mg/L and maintained during filtration. To observe the effect of raw water, three types of raw and processed waters, including river surface water, coagulated water and coagulated-settled water, were applied. In case of river surface water, the transmembrane pressure increased drastically in 500 hours of operation. On the contrary, no significant increase in transmembrane pressure was observed for 1,200 hours of operation for coagulated water and coagulated-settled waters. The turbidity of permeate was lower than a detection limit of equipment for all raw waters. The removal efficiency of humic substances of coagulated water and coagulated-settled water was approximate ten times of that of surface river water. And, the removal efficiency of TOC and DOC was approximate two times of that of surface river water. From the results of plant operation, stable operation was maintained at $0.9m^3/m^2{\cdot}day$ filtration flux through the combination of pre-coagulation and pre-chlorination. However, the water quality of permeate was the best when pre-coagulation-sedimentation process was combined with pre-chlorination.

A Study on Coagulation and MF Membrane Process for the Reuse of Sewage Effluent (하수처리장 방류수의 응집 및 정밀여과 처리공정에 관한 연구)

  • Paik, Ke-Jin
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.3 s.57
    • /
    • pp.36-43
    • /
    • 2005
  • Prior to the study of the sewage treatment methods, water quality for Gwangju sewage of fluent was investigated from January to December, 2004 for sewage water reuse. Monthly mean values of BOD, SS, turbidity, total phosphorus and color were 4.1 mg/L, 2.9 mg/L, 0.8 NTU, 1.3 mg/L, and 27 unit, respectively. Jar-test was performed to investigate the removal efficiency of pollutants under the coagulation conditions of fast mixing for 5 min, slow mixing for 15 min and precipitation for 1hr. Here, alum and polyaluminium chloride (PAC) were used as coagulants to reduce color, turbidity, total phosphorus (TP) and total organic carbon (TOC) in sewage effluents. The results showed that PAC gave better efficiency in removing turbidity and dissolved phosphorus than alum. It was also found from the relative molecular weight (RMW) distribution analysis that organic matter over 1,000 Dalton (Da) was easily removed by coagulation and subsequently MF treatment, while it was not effective for less than 500 Da. Based on tis result, Natural organic matter (NOM) with lower molecular weight (< 500 Da) may cause harmful disinfectant by-product (DBP) after chlorine treatment. Thus, activated carbon adsorption seems to be required for the complete removal of DBP in the hybrid system.

Improvement of Rapid Sand Filtration to Two Stage Dual Media Filtration System in Water Treatment Plant (정수처리장내 급속모래 여과지의 이단복합여과시스템으로의 개량)

  • Woo, Dal-Sik;Hwang, Kyu-Won;Kim, Joon-Eon;Hwang, Byung-Gi;Jo, Kwan-Hyung
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.2
    • /
    • pp.141-149
    • /
    • 2011
  • This study aimed for developing a two stage dual media filtration system. It has a sand and activated carbon layer above the under-drain system, and a sand layer above the middle-drain system for pretreatment. When retrofitting an old sand filter bed or designing a new one, this technology can substitute the existing sand filter bed without requiring a new plant site. The removal rate of total particle is 93, and 3~7 ${\mu}m$ and 5~15 ${\mu}m$ particles are all 97%. These high removal efficiencies of each pollutant due to adsorption and biological oxidation in activated carbon filter layer. The best backwashing method of two stage dual media filtration system is ascertained by air injection, air + water injection and water injection sequence. In this study, a pilot plant of two stage and dual filtration system was operated for 4 months in water treatment plant. The stability of turbidity was maintained below 1 NTU. The TOC, THMFP and HAAFP were removed about 90% by two stage and dual media filtration system, which is almost 2 times higher than existing water treatment plant.

Decomposition of Hexahydro-1,3,5-trinitro-1,3,5-triazine by Gamma Ray Irradiation (감마선 조사에 의한 hexahydro-1,3,5-trinitro-1,3,5-triazine(RDX)의 분해)

  • Lee, Byungjin;Lee, Myunjoo;Kim, Yuri
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.731-741
    • /
    • 2004
  • The purpose of this study was to evaluate the potential of a gamma ray irradiation to decompose hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in an aqueous solution. The decomposition reaction of RDX by gamma ray irradiation was a first-order kinetic over the applied initial concentrations (10-40mg/L). The dose constant was strongly dependent on the initial concentration of the RDX. The removal of RDX was more efficient at pH below 3 and at pH above 11 than at neutral pH (pH 5-9). The required irradiation dose to remove 99% of the RDX (40mg/L) was 4, 8 and 1 kGy, at pH 2, 7 and 13, respectively. The dose constant was increased by two folds and over twelve folds at pH 2 and 13, respectively, when compared with that at pH 7. When an irradiation dose of 20 kGy was applied, the removal efficiencies of TOC were 80, 57 and 91% at pH 2, 7 and 13, respectively. Ammonia and nitrate were detected as the main nitrogen byproducts of RDX and formic acid was detected as an organic byproduct. The results showed that a gamma ray irradiation was an attractive method for the decomposition of RDX in an aqueous solution and it was found that a strong alkaline pH over 12 should be applied to the decomposition reaction of RDX.