• 제목/요약/키워드: TOC removal

검색결과 217건 처리시간 0.025초

오염물질 배출원과 하천에서의 유기탄소 분포 특성 (The Fractionation Characteristics of Organic Matter in Pollution Sources and River)

  • 김호섭;김상용;박지형;한미덕
    • 한국물환경학회지
    • /
    • 제33권5호
    • /
    • pp.580-586
    • /
    • 2017
  • The fractionation characteristics of organic matter were investigated in inflow and effluent of each other pollution sources and river. While the DOC/TOC ratio in the influent of public sewage treatment plant and livestock disposal facilities was above 0.58, the POC/TOC ratio of human livestock Night soil treatment plant and stormwater runoff was more than 0.7. The TOC removal efficiency of public sewage treatment plant and human livestock Night soil treatment plant were 88.5 % and 99.6 %, respectively. Although the concentration distribution of organic matter pollution most of total organic carbon (TOC) in effluent of pollution sources accounted for dissolved organic carbon (DOC) type (DOC/TOC ratio >0.89) and Refractory-DOC (RDOC)/TOC ratio was higher (>0.65). The fractionation characteristics of organic matter in river were similar with that of sewage treatment plant and TOC concentration showed the positive correlation with DOC ($r^2=0.93$) and RDOC ($r^2=0.89$) concentration. The decay rate of Labile DOC (LDOC) (avg. $0.128day^{-1}$) was higher than labile particulate organic carbon (LPOC) ($0.082day^{-1}$), while that of DOC ($0.008day^{-1}$) was lower than POC ($0.039day^{-1}$) (paired t-test, p < 0.001, n = 5). These study results suggested that it should consider important both TOC and DOC as the target indicator to control refractory organic matter in pollution sources.

생물막공정을 이용한 질산화 및 병원성 미생물의 제거 (Nitrification and Removal of Pathogenic Microorganisms Indicators by an upgraded RBC)

  • 방두연;장인수;김지학;와타나베 요시마사
    • 상하수도학회지
    • /
    • 제12권1호
    • /
    • pp.108-114
    • /
    • 1998
  • Experiments on an upgraded RBC were conducted to investigate its removal efficiencies of $NH_4-N$, coliform group and coliphage in the municipal wastewater treatment. A bench scale RBC, made of stainless mesh media with 5mm high surface protrusions, was fed with settled municipal wastewater containing 13-25mg/l of $NH_4-N$ and 40-75mg/l of TOC at the hydraulic loading of $89l/m^2.d$ and $60l/m^2.d$. It was found that the nitrification effectively occured at bulk liquid TOC concentration of less 10mg/l. The coliform group and coliphage were more than 98% and 90%, respectively.

  • PDF

Ozone을 이용한 염료용액의 탈색 처리 (The decolorization treatment of dye solutions by ozone)

  • Lee, Soo-Kyung;Cho, Hwan;Jeong, Hee-Cheon
    • 한국염색가공학회지
    • /
    • 제8권5호
    • /
    • pp.17-24
    • /
    • 1996
  • Dye solutions were tested in order to find the optimal condition of ozonation and determine the progress of degradation, i.e., change of the parameters characterizing the dye solutions. From the results of our experiment we can conclude that almost all of the color was removed within a 10 minute time period. An ozone oxidation results in the effective removal of COD(60%). but the elimination of the total organic carbon(TOC) was not successful, only about 15~40% of TOC was removed from dyeing wastewater in 30 minutes. The color removal is much effective in using ozonation method.

  • PDF

자연정화공법에 의한 하수처리장에서 오염물질의 존재형태별 처리효율 (Treatment Efficiency of Existing Forms of Pollutants in Sewage Treatment Plant by Natural Purification Method)

  • 서동철;이병주;황승하;이홍재;조주식;이상원;김홍출;허종수
    • 한국환경농학회지
    • /
    • 제25권2호
    • /
    • pp.129-137
    • /
    • 2006
  • 농촌 마을단위 하수처리장에서 오염물질의 존재형태별 처리 경향을 파악하여 하수처리장의 설계 및 시공시 부지면적 감소와 오염물질의 처리효율 극대화를 위한 기초자료로 활용하기 위하여 농촌 마을 단위 하수처리장을 호기성조와 혐기성조로 구분하여 시공한 다음 하수처리 경과시기별, 오염물질 부하량별 및 계절별로 각 오염물질의 존재형태별 수처리 효율을 조사하였다. 하수처리 경과시기에 따른 오염물질 처리효율을 조사한 결과 호기성조 처리수에서 하수처리 시간이 경과함에 따라 BOD, COD, TOC 및 SS처리량은 큰 폭으로 증가하였다. 처리된 오염물질의 존재형태를 조사한 결과 호기성조 및 혐기성조에서 BOD는 대부분 IBOD로, COD는 대부분 ICOD로, TOC는 대부분 STOC로, SS는 대부분 VSS로, T-N은 대부분 DTN 및 T-P는 대부분 DTP로 처리되었다. 부하량별 오염물질 처리효율을 조사한 결과 BOD 처리량은 호기성조와 방류수 모두에서 처리된 대부분의 BOD는 IBOD이었다. COD 처리량도 BOD와 유사하게 호기성조에서는 대부분 ICOD형태로 처리되었으나, 혐기성조에서는 ICOD와 SCOD가 비슷한 처리량을 보였다. 그러나 하수처리장에서 처리되는 TOC의 존재형태별 처리량은 BOD 및 COD와는 달리 호기성조 처리수와 방류수 모두에서 STOC의 처리량이 약간 많았다. 부하량별 SS 처리효율은 호기성조 처리수에서 95%정도 처리되어 대부분의 SS는 호기성조에서 처리되었으며, 처리되는 SS의 용존형태는 호기성조 처리수에서는 대부분 VSS로 처리되었고, 방류수에서는 VSS와 FSS가 비슷한 양으로 처리되었다. 부하량별 T-N 처리효율은 호기성조 처리수에서 32%정도이었고, 방류수에서 24%정도이었다. 또한 처리되는 T-N의 용존형태는 호기성조 처리수와 방류수 모두에서 DTN이 STN에 비해 월등히 많은 양이 처리되었다. 부하량별 T-P 처리효율은 호기성조에서 62%정도이었고, 혐기성조에서 14%정도로 대부분 호기성조에서 처리되었으며, 처리되는 T-P의 용존형태는 호기성조와 방류수 모두에서 대부분 DTP형태이었다. 계절별 오염물질 처리량을 조사한 결과 BOD, COD, TOC, SS, T-N 및 T-P 처리량은 여름과 가을이 봄과 겨울에 비해 처리량이 약간 증가되었으며, BOD, COD, TOC, SS, T-N 및 T-P는 4계절 모두 방류수의 처리효율이 각각 92, 89, 73, 95, 46 및 84%이상의 높은 처리효율을 나타내었다.

순환여과식 양식 시스템에 있어서의 고정화 탈진균에 의한 질산염 제거 (Nitrate Removal by Immobilized Denitrifying Bacteria in Recirculating Aquaculture System)

  • 김상희;김필균;김중균
    • 생명과학회지
    • /
    • 제9권6호
    • /
    • pp.698-703
    • /
    • 1999
  • For the nitrate removal in recirculating aquaculture system, a denitrifying bacterium, Pseudomonas fluorescens, was isolated from municipal sewage and the cells were immobilized in modified-polyvinly alchol (PVA) gel beads. The immobilized cells in both the fixed-and fluidized-bed reactors showed 98% of denitrification efficiency with 6hr HRT, and the removal efficiency of total organic carbon (TOC) was above 90%. Form scanning electron microscopy (SEM) observation, it was known that biofilm formed in fixed-bed reactor was thicker than that formed in fluidized-bed reactor as operation time passed.

  • PDF

오존산화에 의한 수처리공정에서 VOCs의 제거 특성 (VOCs Removal in Drinking Water Treatment Process by Ozonation)

  • 한명호;최준호;임학상
    • 상하수도학회지
    • /
    • 제11권2호
    • /
    • pp.65-75
    • /
    • 1997
  • Removal characteristics of volatile organic carbons(VOCs) by ozone oxidation and other processes in the raw water of the 1st Nakdong water treatment plant were investigated. Dichrolomethane, toluene and other 7 compounds were detected in the raw water. With regard to detected 4 compounds in finally treated water, it was found that VOCs could not be removed effectively by traditional water treatment process. Benzene, 1,2-dichlorobenzne were not detected in the raw water but they were detected in the process of treatment. The compound of highest detection frequency was dichloromethane. When the raw water was controlled at pH 7, temperature $20^{\circ}C$, 5 minutes as contact time, 10 minutes as reaction time, the removal rate of THMFP, $KMnO_4$ demand, TOC, $UV_{254nm}$ and $NH_3-N$ were 46.4%, 22%, 19.6%, 31% and 8%, respectively. From estimating the finally treated water qualities in 7 kinds of treatment processes, P-6 process(raw water-chlorination-coagulation-ozonation) was most effective for organics removal and THMs control. Removal efficiencies for $KMnO_4$ demand and TOC by the process which combined preozonation with coagulation was twice better than only preozonation. $NH_3-N$ removal rate was shown as 10% by P-3 process(raw water-coagulation-ozonation), but 83% of $NH_3-N$ was removed by P-4 process(raw water-coagulation-chlorination). It was found that the chlorination is more effective than the ozonation for the NH3-N removal as commonly known.

  • PDF

갈수기 정수장운영관리 사례 - 갈수기 pH저감제(황산)투입에 의한 정수처리효율 향상 (Improvement of Water Treatment Efficiency by pH Decreasing Agent (H2SO4) for Droughty Seasons)

  • 가길현;김윤용;이준호;안치화;한인섭;민병대
    • 한국물환경학회지
    • /
    • 제24권4호
    • /
    • pp.415-422
    • /
    • 2008
  • Drinking water treatment is enhanced by coagulant dosages and chlorine injection because of pH increase in raw water in droughty seasons such as spring and fall. But water quality deterioration is occurred by increase in residual aluminium and disinfection by-products. Coagulation process can be used to control natural organic matter (NOM) during water treatment. The effect of coagulation process appeared to depend on the pH of water rather than coagulant dosages. In this study, for water treatment in high pH season $H_2SO_4$ was applied for pH adjustment at full scale. Before and after pH adjustment by $H_2SO_4$ injection, water quality of drinking water was evaluate. In the result of investigation of total organic carbon (TOC) removal in high pH season, TOC was removed approximately 30~40%, which showed decrease in water treatment efficiency. Also, it is increased both particle numbers and residual Al concentration in the water. After $H_2SO_4$ injection for adjustment to pH<7.5 in settled water, treated water turbidity decreased in 0.047 NTU from 0.059 NTU, and particle numbers of filtered water decreased in 20/mL from 90/mL. On the other side, TOC removal efficiency increased in approximately 10% after adjustment of pH. In the result of decrease in pH in raw water through more coagulants and prechlorine without $H_2SO_4$ injection, trihalomethanes (THMs) concentration increased in $16{\mu}g/L$ from $8{\mu}g/L$.

MF-UF 분리막 복합공정에 의한 염색가공 폐수처리 (Textile Wastewater Treatment by MF-UF Combined Membrane Filtration)

  • 양정목;박철환;이병환;김상용
    • 청정기술
    • /
    • 제12권3호
    • /
    • pp.151-156
    • /
    • 2006
  • 염색폐수 처리를 위해 세라믹 정밀여과막 (MF)과 고분자 한외여과막 (UF)의 복합공정을 적용, 색도 및 유기물 (TOC) 제거율을 통해 공정을 최적화하고, 염색폐수의 분리효율을 조사하였다. 막 회복을 통한 운전 효율향상을 위해 역세척과 화학세정을 수행한 결과, 역세척에 의한 정밀여과막은 2분 주기로 1초 동안 역세척하였을때 투과수량이 10.3% 증가하였고, 한외여과막은 0.1% 수산화나트륨 용액으로 화학세정하였을 때 97%의 회복률을 나타내었다. 이때, 유기물, 색도, 부유물질(SS)의 제거율은 각각 84.6%, 97.4% 및 100%를 나타내었다. 분 복합공정의 적용은 염색폐수의 색도와 유기물 제거에 효과적임을 확인할 수 있었다.

  • PDF

유기물 농도가 낮은 고품질 정수 생산을 위한 고압막여과 공정 설계 시 고려사항 (Considerations to design high-pressure membrane system to produce high quality potable water with lower organic matter concentration)

  • 전종민;김성수;서인석;김수한
    • 상하수도학회지
    • /
    • 제34권6호
    • /
    • pp.473-480
    • /
    • 2020
  • High-pressure membrane system like nanofiltration(NF) and reverse osmosis(RO) was investigated as a part of water treatment processes to produce high quality potable water with low organic matter concentration through membrane module tests and design simulation. River water and sand filtration permeate in Busan D water treatment plant were selected as feed water, and NE4040-90 and RE4040-Fen(Toray Chemical Korea) were used as NF and RO membranes, respectively. Total organic carbon(TOC) concentrations of NF and RO permeates were mostly below 0.5 mg/l and the average TOC removal rates of NF and RO membranes were 93.99% and 94.28%, respectively, which means NF used in this study is competitive with RO in terms of organic matter removal ability. Different from ions rejection tendency, the TOC removal rate increases at higher recovery rates, which is because the portion of higher molecular weight materials in the concentrated raw water with increasing recovery rate increases. Discharge of NF/RO concentrates to rivers may not be acceptable because the increased TDS concentration of the concentrates can harm the river eco-system. Thus, the idea of using NF/RO concentrate as the raw water for industrial water production was introduced. The design simulation results with feed water and membranes used in this work reveal that the raw water guideline can be satisfied if the recovery rate of NF/RO system is designed below 80%.

복합 막분리 공정에 의한 섬유가공 공정에서의 가성소다 회수 (Recovery of Caustic Soda in Textile Mercerization by Combined Membrane Filtration)

  • 양정목;박철환;조진구;김상용
    • 대한환경공학회지
    • /
    • 제30권12호
    • /
    • pp.1273-1280
    • /
    • 2008
  • 본 연구에서는 섬유가공공정 중 머서화공정으로부터 가성소다액를 회수하기 위한 최적의 운전조건을 확립하고자 하였다. 주요 인자들로는 NF/RO막의 적용을 위해 세라믹 막을 이용하여 파울링 지수를 평가, 고분자 막의 적용을 위해 가성소다액의 회수율을 측정, 막의 재생율 향상, 화학세정 조건, 유기물부하, 탁도 및 색도의 최적 제거조건, 그리고 세라믹 막과 고분자막의 복합공정에서의 투과플럭스를 조사하였다. 결과에 따르면, 1단계 공정의 세라믹 한외여과막과 2단계 공정의 나노여과막은 총부유고형물, 잔류유기물, 색도를 포함한 탁도의 제거 그리고 가성소다 용액의 회수에 적합한 공정구성임을 확인하였다. 한외여과막만을 단독으로 사용했을 경우, 총 부유물질과 탁도를 99.0%이상 제거하였고, 색도와 TOC는 각각 74.7%와 49.2%의 제거효율을 얻을 수 있었다. 반면에 세라믹 UF+NF 복합막 공정에서는 총 부유물질과 탁도를 99.9%이상 제거할 수 있었고, 색도는 87.7%, TOC는 78.2%의 제거효율을 얻을 수 있었다. 특히, 복합막 공정에서는 83.7%의 부피회수율일 때 91.3% 가성소다를 성공적으로 회수 할 수 있었다. 이러한 측면에서 복합공정을 통해 가성소다 폐수로부터 순도 높은 가성소다액을 회수할 수 있었으며, 회수된 가성소다액은 공정 내에 재사용이 가능하여 경제적인 이득을 기대할 수 있다.