• Title/Summary/Keyword: TOC 제거

Search Result 162, Processing Time 0.026 seconds

The Air-stripping Process Conjugated with the Ultrasonic Treatment to Remove TOC in Groundwater around the LPG Underground Storage Cavern (탈기법과 초음파 처리법을 연계한 LPG 지하공동저장소 주변 오염지하수 내 TOC 제거)

  • Han, Yikyeong;Jun, Seongchun;Kim, Danu;Jeon, Soyoung;Lee, Minhee
    • Economic and Environmental Geology
    • /
    • v.55 no.5
    • /
    • pp.511-519
    • /
    • 2022
  • In order to develop an air-stripping based remediation process to remove the TOC (Total Organic Carbon) in groundwater around the underground LPG storage cavern, the laboratory scale experiments at various conditions (change of air injection volume and temperature, the application of ultrasonic treatment, etc.) for two types of groundwater (initial TOC concentration of 608 mg/L and 153 mg/L, respectively). From results of experiment, as the air injection rate for stripping into groundwater increased from 2 L/min to 11 L/min and as the air-stripping time increased from 1 hour to 24 hour, the TOC removal efficiency of air-stripping increased. However, the TOC concentration of treated groundwater was higher than the discharge tolerance limit (100 mg/L) even after 24 hour stripping at the maximum air injection rate of 11 L/min. The main compounds of the TOC in groundwater were identified as methanol and propane and the long stripping time (more than 24 hour) was needed to separate the methanol from groundwater because of the affinity between water and methanol. At 20℃ and 4 L/min of air injection, the TOC removal efficiency increased to 59.1% after 24 hour air-stripping. When the temperature of groundwater increased to 30℃ and 40℃, the TOC removal efficiency increased up to 80.0% and 82.8%, suggesting that more than 24 hour air-stripping at 40℃ is needed to lower the TOC concentration to below 100 mg/L and the additional TOC removal process as well as the air-stripping is necessary. When the temperature increased to 60℃ and the ultrasonic treatment was conjugated with the air-stripping, the TOC removal efficiency increased to 87.8% within 5 hour stripping and the final TOC concentration (72.4 mg/L) was satisfied with the TOC discharge tolerance limit. The TOC removal efficiency for groundwater having low TOC concentration (153 mg/L) also showed similar removal efficiency of 89.7% (the final TOC concentration: 18.9 mg/L). Results in this study supported that the air-stripping conjugated with the ultrasonic treatment could remove successfully the TOC in groundwater around the underground LPG strorage cavern.

Optimal coagulant and its dosage for turbidity and total organic dissolved carbon removal (탁도와 총유기탄소 제거를 위한 최적응집제 및 투여량 선정 연구)

  • Park, Hanbai;Woo, Dal-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2321-2327
    • /
    • 2015
  • Three coagulants, alum sulfate(alum), poly aluminum chloride(PAC) and poly aluminum silicate chloride (PASC), were used to remove low to high turbidity and TOC in surface and ground blended water. Laboratory experiments and pilot plant experiments were carried out to evaluate the optimal coagulant and its dosage. To determine the optimized coagulant and its dosage, the turbidity, TOC and pH were measured. The experimental results showed the best removal performance using PASC. The optimal dosage of PASC between 3-20 NTU was found to be 15 mg/L in the jar test. In the pilot test, a 15 mg/L PASC dosage was applied and resulted in the efficient removal of turbidity and TOC between 3.6-27 NTU. The removal efficiency of PASC increased with increasing turbidity and TOC.

Quantitative Analysis for the Behaviour of Phosphorus and TOC in Biological Wastewater Treatment (생물학적 폐수처리에서 인과 TOC 거동의 정량적인 해석)

  • Choi, Suk-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.44-50
    • /
    • 1999
  • 기존의 생물학적 인 제거 공정은 주로 경험적 인자를 고려하여 운전되었기 때문에 아직까지 폐수처리 시스템 전체를 파악할 수 있는 정량적인 연구가 미흡한 실정이다. 본 연구에서는 생물학적 인과 Total Organic Carbon(TOC)의 제거 공정을 모사하기 위하여 단일 균주인 Staphylococcus auricularis를 이용하였으며, 여기서 혐기와 호기 조건을 동시에 고려하는 모델 시스템을 제안하였다. 이 모델 시스템에서는 미생물 안의 인 농도를 고려한 인의 방출과 제거 특성을 나타내었으며, 인과 TOC가 제거되는 과정을 잘 모사하였다. 그리고 폐수 중 인의 농도 변화에 의한 인을 효과적으로 처리하기 위하여 각 농도별로 요구되는 싸이클 수를 예측할 수 있었다.

  • PDF

Characterization of Humic Acid in the Chemical Oxidation Technology(I) - Characteristics by Photocatalytic Oxidation Process - (화학적 산화법에 의한 부식산의 분해 처리기술에 관한 연구(I) - 광산화공정을 통한 부식산의 분해특성 분석 -)

  • Kim, Jong Boo;Rhee, Dong Seok
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.234-240
    • /
    • 2000
  • The efficiency of Photocatalytic Oxidation Process were investigated for the treatment of Aquatic Humic Substances (AHS). In UV-only system, pH 7-9 was the optimum pH range for TOC removal, and alkali range was the optimum pH for absorbance decrease. In UV/$TiO_2$ system, the optimum $TiO_2$ dosage was 50ppm and over 50ppm of $TiO_2$ dosage was not effective for removal of AHS. In UV/$H_2O_2$ system, optimum $H_2O_2$ dosage was 20mM, when over 20mM dosage, removal of TOC (Total Organic Carbon) and absorbance was decreased. Radical scavenger affected on the photo-oxidation of AHS. Removal rate of TOC and absorbance was decreased by addition of carbonate ions and TOC removal was more effected than that of absorbance.

  • PDF

Catalytic Wet Oxidation of Azo Dye Reactive Black 5 (아조염료 Reactive Black 5 폐수의 촉매습식산화)

  • Suh, Il-Soon;Yoo, Shin-Suk;Ko, Mi-So;Jeong, Samuel;Jung, Cheol-Goo;Hong, Jeong-Ah;Yoon, Wang-Lai
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.259-267
    • /
    • 2010
  • The catalytic wet oxidations of the wastewater containing azo dye Reactive Black 5(RB5) with heterogeneous catalyst of CuO have been carried out to investigate the effects of temperature($190{\sim}230^{\circ}C$) and catalyst concentration(0.00~0.20 g/l) on the removals of colour and total organic carbon TOC. The wastewater colour was measured with spectrophotometer, and the oxidation rate was estimated with TOC. About 90% of colour was removed during 120 min in thermal degradation of the RB5 wastewater at $230^{\circ}C$, while TOC was not removed at all. As increasing reaction temperature and catalyst concentration, the removal rates of colour and TOC increased in the catalytic wet oxidations of RB5 wastewater. The effects of catalyst were already considerable even at 0.01 g CuO/l, while the removal rates of colour and TOC increased negligibly with increasing the catalyst concentration above 0.05 g CuO/l. The initial destruction rates of the wastewater colour have shown the first-order kinetics with respect to the wastewater colour. TOC changes during catalytic wet oxidations have been well described with the global model, in which the easily degradable TOC was distinguished from non-degradable TOC of the wastewater. The impacts of reaction temperature on the destruction rate of the wastewater colour and TOC could be described with Arrhenius relationship. Activation energies of the colour removal reaction in thermal degradation, wet oxidation, and catalytic wet oxidation(0.20 g CuO/l) of the RB5 wastewater were 108.4, 78.3 and 74.1 kJ/mol, respectively. The selectivity of wastewater TOC into the non-degradable intermediates relative to the end products in the catalytic wet oxidations of RB5 wastewater was higher compared to that in phenol wet oxidations.

Optimal Condition of TOC Removal Parameter for Sewage Effluent using Electrolysis Process (하수방류수 내 TOC 제거를 위한 전기분해공정의 최적 조건)

  • An, Sang-Woo;Jung, Hyuk-Sang;Lee, Hui-Kyung;Ko, Jun-Geol;Myoung, Dae-Won
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.4
    • /
    • pp.23-29
    • /
    • 2017
  • As the Enforcement Ordinance of Environmental Policy Act was revised in 2013, Total Organic Carbon (TOC) was added as an indicative parameter for organic matter in Water and Aquatic Ecosystem Environmental Criteria. Under these imminent circumstances, a regulatory standard is needed to achieve the proposed TOC limitation control water quality from the STP (Sewage Treatment Plant). In this study, a electrolysis utilizing the electrochemical reaction was investigated in lab-scale experiments for the treatment of TOC in sewage effluent. TOC reduction by a electrolysis was investigated response surface methodology using the Box-Begnken methods were applied to the experimental results. A central composite design was used to investigate the effects of the independent variables of electrode space ($x_1$), current density ($x_2$) and electrolyte concentration ($x_3$) on the dependent variables removal efficiency of TOC (y). The optimal conditions for electrolysis were determined: electrode space, current density and electrolyte concentration were 50 mm, $10.3mA/cm^2$ and 0.1M, respectively. Statistical results showed the order of significance of the independent variables to be electrode space > current density > electrolyte concentration.

Performance Evaluation for the A/O Pure-Oxygen Biofilm (POB) Process on the Removal of Organics and TKN in the Industrial Wastewater (혐기/호기 순산소 생물막공법에 의한 산업폐수의 유기물 및 TKN 제거 성능평가)

  • Jang, Am;Kim, Hong Suck;Kim, In S.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.5
    • /
    • pp.837-847
    • /
    • 2000
  • For the treatment of wastewaters generated from beer industry and petrochemical company with high organic and nitrogen contents, laboratory scale of A/O Pure-Oxygen Biofilm (POB) process was developed and studied by means of the comparative economic analysis with extended aeration process. When the wastewater of beer company was initially treated by the A/O POB process in the ranges of 70 to 150 mg TOC/L diluted with tap water, higher than 92% of TOC removal was accomplished in the all ranges. In case of petrochemical wastewater, the initial TOC removal was as low as 52%, though, it increased to 86% after 32 days of operation and also the TKN removal marked 71% after 27 days. Continuous high removal rates were monitored in both the TOC and TKN parameters during the experimental period. Due to the cost for PSA (Pressure Swing Adsorption) setting and biomass supporting media installation, the initial construction cost of A/O POB process was 2.9 times higher than that of extended aeration process. However, the advantages such as low sludge production, no need for sludge recycling and low energy consumption allow the A/O POB process to have 2.5 times lower operation and maintenance costs. Consequently, in the long term of operation, it is likely that A/O POB process would show higher performance as well as cost effectiveness compared to extended aeration process.

  • PDF

Analysis of Nonlinear Dynamical Behavior for the Daily TOC Time Series in a River (하천의 일TOC 시계열 자료의 비선형 동역학적 거동 분석)

  • Oh, Chang-Ryol;Jin, Young-Hoon;Park, Sung-Chun;Jung, Woo-Chul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1032-1036
    • /
    • 2006
  • 본 연구에서는 영산강 본류를 대표하는 나주지점을 대상으로 하여, 해당 지점에서 자동 측정되고 있는 수질 항목들 중에서 총유기탄소(TOC: Total Organic Carbon)의 시계열 자료에 대한 비선형 동역학적 거동을 파악하고자 하였다. 1994년 낙동강에서의 수질오염 사고 이후 4대강 유역에서 설치.운영되고 있는 수질자동 측정망의 TOC 자료를 일자료로 환산하여 사용하였으며, 시계열 자료에 비선형 동역학적(카오스적) 특성이 존재하는지를 알아보기에 앞서 자료의 전처리 과정으로써 3가지의 잡음제거 방법을 적용하였다. 잡음이 제거된 시계열 자료에 비선형 동역학적 거동의 파악을 위해 보편적으로 사용되고 있는 상관차원분석을 실시하였다. 또한 상관차원분석 결과 비선형 동역학적 거동을 나타내는 것으로 판별된 자료에 대하여 그 양상을 가시적으로 알아보기 위해 지체시간$(\tau)$을 적용하여 3차원 위상공간에 도시하였다. 본 연구의 결과, 나주지점에서 측정되고 있는 총유기탄소에 대해 비선형 잡음제거 방법을 적용한 자료가 비선형 동역학적 거동을 내재하고 있는 것으로 나타났으나, 이를 위상공간에 재건하였을 경우 이상한 끌개(strange attractor)의 뚜렷한 구조가 보이지 않았다. 그러나 상관차원분석 결과 잡음이 제거된 자료가 카오스적 특성을 보이므로, 자료의 단기예측을 위한 방법에 기초적인 정보를 제공할 수 있을 것으로 기대된다.

  • PDF

Outlier Detection and Treatment for the Conversion of Chemical Oxygen Demand to Total Organic Carbon (화학적산소요구량의 총유기탄소 변환을 위한 이상자료의 탐지와 처리)

  • Cho, Beom Jun;Cho, Hong Yeon;Kim, Sung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.4
    • /
    • pp.207-216
    • /
    • 2014
  • Total organic carbon (TOC) is an important indicator used as an direct biological index in the research field of the marine carbon cycle. It is possible to produce the sufficient TOC estimation data by using the Chemical Oxygen Demand(COD) data because the available TOC data is relatively poor than the COD data. The outlier detection and treatment (removal) should be carried out reasonably and objectively because the equation for a COD-TOC conversion is directly affected the TOC estimation. In this study, it aims to suggest the optimal regression model using the available salinity, COD, and TOC data observed in the Korean coastal zone. The optimal regression model is selected by the comparison and analysis on the changes of data numbers before and after removal, variation coefficients and root mean square (RMS) error of the diverse detection methods of the outlier and influential observations. According to research result, it is shown that a diagnostic case combining SIQR (Semi - Inter-Quartile Range) boxplot and Cook's distance method is most suitable for the outlier detection. The optimal regression function is estimated as the TOC(mg/L) = $0.44{\cdot}COD(mg/L)+1.53$, then determination coefficient is showed a value of 0.47 and RMS error is 0.85 mg/L. The RMS error and the variation coefficients of the leverage values are greatly reduced to the 31% and 80% of the value before the outlier removal condition. The method suggested in this study can provide more appropriate regression curve because the excessive impacts of the outlier frequently included in the COD and TOC monitoring data is removed.

Preparation and Characteristics of Immobilized Sludge by the PAA Entrapment Method (PAA 포괄법에 의한 고정화 슬러지의 제조 및 특성에 관한 연구)

  • 최석순
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.3
    • /
    • pp.49-54
    • /
    • 2002
  • This study was conducted to evaluate the feasibility and characteristics of poly acrylamide (PAA) immobilized sludge as a microbial entrapment bead for wastewater treatment. In the PAA method of immobilized sludge, it was found that the optimum acrylamide concentration for actual wastewater treatment was to be 12%. When the sequencing batch reactor (SBR) was operated during 30 days, removal efficiencies of TOC and phosphate was 95% and 70ft, respectively. From this research, repeated cycle of anaerobic and aerobic conditions is required to enhance the removal of TOC and phosphate. During the operation, immobilized cells could be used without being disrupted.