• 제목/요약/키워드: TN-C

검색결과 387건 처리시간 0.022초

Biofilm으로 충전된 단일 Column을 이용한 폐수의 질산화/탈질산화 공정 연구 (Nitrification/Denitrification of Wastewater in one Column containing Biofilm)

  • 배해룡
    • 환경위생공학
    • /
    • 제17권2호
    • /
    • pp.79-84
    • /
    • 2002
  • This study investigated possibility of the nitrification and denitrification in one counter-current column with the growth of biofilm attached to its media. This experiment was performed through use of the lab scale reactor composed of the column and settler. The column used was packed with the small size of plastic rings called PALL($1.5{\times}1.5{\;}cm$) with a cylindrical shape. Synthetic wastewater was used in the experiment. The loading rates of carbon (C) and total nitrogen (TN) furnished to the reactor were 0.23 to 1.0 kg COD/m3.d and 0.023 to 1.0 kg N/m3.d, respectively. Major factors controlling the removal efficiencies of COD and TN were the different air flux and volumetric loading rates of COD and TN. The experimental results obtained from this study demonstrated that the removal efficiencies of COD ranged from 90 to 95% and those of TN were from 80 to 83% under the N loading rate of 0.035 and $0.058{\;}kg{\;}N/m^3{\cdot}d$, respectively. The patterns of TN removed were distinctively different on the limit of 50cm of column in depth. This indicated that the nitrification and denitrification occurred near the surface zone of and inside the biofilm respectively, upto the 50cm of the column in depth.

UV 조사법을 이용한 새로운 무기박막 표면에 액정 배향 효과 (Alignment Effect of Liquid Crystal on new organics thin film using Ultraviolet Exposure method)

  • 황정연;강형구;최성호;오병윤;함문호;명재민;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집 디스플레이 광소자 분야
    • /
    • pp.62-65
    • /
    • 2005
  • We studied the nematic liquid crystal (NLC) alignment capability by the Ultraviolet (UV) alignment method on a-C:H thin-films, and investigated electro-optical performances of the UV aligned twisted nematic (TN)-liquid crystal display (LCD) with the UV exposure on a-C:H thin film surface. A good LC alignment by UV irradiation on a-C:H thin-film surfaces was achieved. Monodomain alignment of the UV aligned TN-LCD can be observed. The good electro-optical (EO) characteristics of the UV aligned TN-LCD was observed with oblique UV exposure on the a-C:H thin film surface for 1min.

  • PDF

Physicochemical tolerance ranges and ecological characteristics in two different populations of Carassius auratus and Cyprinus carpio

  • Kang, Seung Gu;Choi, Ji-Woong;An, Kwang-Guk
    • Journal of Ecology and Environment
    • /
    • 제38권2호
    • /
    • pp.195-211
    • /
    • 2015
  • The objectives of this research were to determine mean and maximum tolerance ranges of Carassius auratus ($C_a$) and Cyprinus carpio ($C_c$) populations on various physico-chemical parameters and ecological indicator metrics. Little is known about chemical tolerance ranges of the two species, even though these species are widely distributed species in aquatic ecosystems. Maximum tolerance ranges of $C_a$-population to total nitrogen (TN) and total phosphorus (TP) were $20.3mgL^{-1}$ and $2.0mgL^{-1}$, respectively. Optimal ranges of TN and TP in the $C_a$-population were $1.7-5.0mgL^{-1}$ and $0.06-0.30mgL^{-1}$, respectively. Such nutrient regimes of the $C_a$-population were evaluated as hypereutrophy, indicating high tolerance limits. The $C_c$-population had similar ecological characteristics to $C_a$-population, but the mean tolerance ranges of TN, TP, BOD, and COD were significantly (p < 0.05) greater than the $C_a$-population. Ecological patterns of trophic composition and tolerance guilds in the $C_a$-population were similar to those of the $C_c$-population. The model value of Index of Biological Integrity (IBI) of the habitat where C. auratus and C. carpio co-occurred averaged $15.0{\pm}4.3$ and $12.9{\pm}3.6$, respectively. Based on the modified criteria of the United States Environmental Protection Agency (Klemm et al. 1993), it indicated poor ecological health of both species. These results suggest that both species are highly tolerant to chemical and physical habitat conditions of waterbodies, and that the chemical tolerance range of $C_c$-population was higher than $C_a$-population.

Pile Contact Depth Effects in Rubbed Polyimide(PI) Films

  • 김기정;권혁민;이상문;이철구;곽무선;김봉수
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.398-398
    • /
    • 2010
  • To determine the molecular directionality of PI chains depending on rubbing condition, we measured the angle resolved near edge X-ray absorption fine structure (NEXAFS) spectra at C K-edge of the rubbed PI films. Twisted nematic mode PI (PI-TN) and in plane switching mode PI (PI-IPS) were introduced to examine the effect of rubbing conditions on the chain directionality. The average tilt angle a of the PI molecules was estimated through the measured intensity change of $C=C\;{\pi}^*$ in NEXAFS C K-edge spectrum by controlling the stage speed and the pile contact depth. After rubbing, the irregular molecular direction changed to a regular direction with a molecular tilt angle of $51.2^{\circ}$ for PI-TN and $49.6^{\circ}$ for PI-IPS at the rubbing condition of the roll speed of 1000 rpm, stage speed of 50 mm/sec, and file contact depth of 0.3 mm. The molecular tilt angle $\alpha$ was linearly decreased in the PI-TN and PI-IPS samples with increasing depth of the pile contact.

  • PDF

IEC 60364 적용 및 TN-S 시스템에서 보호 도체 산정 및 적정성에 관한 연구 (Assessment Method and Calculations for Protective Conductor of TN-S System and IEC 60364 Application)

  • 김기현;이주철;최영규;김한수;이영철
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.86-91
    • /
    • 2012
  • A conductor has been produced according to IEC standard and low voltage electrical facility has been installed according to IEC 60364. So we must comply with international standard for design, construction and inspection. But because of many related and varied standards, it is difficult to apply to design and inspect for electrical equipment. We researched the necessity of design guide which is detailed and systematization from survey. For detailed design guide, we suggest calculation method of protective conductor cross-sectional area at TN-S system according to BS 7671 regulation and KS C IEC 60364 standard.

Evaluation of plasma N-terminal pro-brain natriuretic peptide and troponin I concentrations in dogs with congenital ventricular outflow tract stenosis

  • Kim, Gye-Dong;Suh, Sang-IL;Park, In-Chul;Hyun, Changbaig
    • 대한수의학회지
    • /
    • 제56권4호
    • /
    • pp.223-227
    • /
    • 2016
  • This study evaluated the levels of cardiac biomarkers in dogs with either pulmonic stenosis or aortic stenosis and the correlation between biomarkers and the severity of stenosis assessed by the echocardiography. To achieve this study goal, 38 dogs (10 healthy control dogs, 15 dogs with pulmonic stenosis and 13 dogs with aortic stenosis) were examined. The jet velocity and pressure gradient in this study population were measured by echocardiographic estimation, after which the study group was subdivided by the severity of stenosis. The plasma cardiac troponin I (cTnI) and N-terminal pro-brain natriuretic peptide (NT-proBNP) were measured in this study group. The median concentrations of cTnI and NT-proBNP of the disease group were significantly higher than those of the control group, and these increased gradually as stenosis worsened. The severity of stenosis and the concentrations of cTnI and NT-porBNP were also found to be significantly correlated. Finally, the plasma cTnI and NT-proBNP tests were found to beneficial for differentiating clinical patients, predicting the progression of disease, and monitoring the outcome of interventional therapy for stenosis.

시뮬레이션 기법을 이용한 기존 BNR공정의 C/N비 변화에 따른 운전조건 최적화 (Optimization of Operational Conditions of Existing BNR Process with Various C/N Ratio using Simulation Method)

  • 노해연;길경익
    • 한국물환경학회지
    • /
    • 제23권3호
    • /
    • pp.367-370
    • /
    • 2007
  • Numerous sets of simulation were conducted in order to find out the optimum operational conditions of the existing BNR process using GPS-X program. The model of ASM3 and modified Bio-P module were applied for simulations. From the result of this study, effluent quality was closely related with the step feeding rate and influent C/N ratio. The effluent TN concentration seemed to be significantly affected by step feeding rate at the low C/N condition. But at the high C/N condition, the effluent concentration of TP rather than that of TN was affected by the control of step feeding rate.

저수지 유입하천 현장적용실험을 통한 수질정화효율 평가 (Evaluation of Pollutant Removal Efficiency through Field Test-Bed Experiment in the Rural Small Stream)

  • 최선화;오종민;김태훈
    • 한국수자원학회논문집
    • /
    • 제47권12호
    • /
    • pp.1135-1143
    • /
    • 2014
  • 본 연구에서는 사상성 조류로 구성된 수질정화시설의 수질정화효율을 평가하고자 충남 서산시 음암면에 소재한 성암저수지 유입하천 홍수부지에 test-bed를 설치하고 유입하천수를 대상으로 현장적용실험을 실시하였다. 수질항목별로 정화효율을 평가한 결과, SS 80.9%, COD 74.6%, T-N 76.8%, T-P 84.4%, DTN 93.8%, DTP 98.3%의 제거효율을 보였다. 수온에 따른 정화효율은 수온이 약 $20^{\circ}C$로 유지되어 수질정화효율에 미치는 영향은 없는 것으로 나타났다. 수리학적 체류시간(HRT)은 SS 및 TP 처리효율과 유의한 상관성이 있는 것으로 나타났고, 체류시간을 5일로 했을 때 SS, TP 처리효율이 좋은 것으로 나타났다. 유입수의 COD/TN에 따른 처리효율은 TN, TP 모두 C/N비가 낮을수록 증가하였고, 유입수의 COD/TP에 따른 처리효율도 C/P비가 낮을수록 TN, TP 모두 처리효율이 증가하는 것으로 나타났다.

Establishment of Mouse Embryonic Stem Cell and Effects of Herbal Medicine on Induction of Cardiomyocyte Differentiation

  • Lee, Ji Hyang;Lee, Eun
    • 한국자원식물학회지
    • /
    • 제25권6호
    • /
    • pp.693-699
    • /
    • 2012
  • This study was conducted to investigate the effects of Woohwangcheungsimweun (ox bezoar), deer antlers, and wild ginseng on induction of cardiomyocyte differentiation using the established mouse embryonic stem (ES) cells. The expression of atrial natriuretic peptide (ANP) was highest in Woohwangcheungsimweun treatment group. The expression of rabbit anti-GATA-4(GATA-4) and troponin (TnI) were highest in wild ginseng and Woohwangcheungsimweun treatment groups, respectively. Fluorescence activated cell sorting (FACS) analysis showed that the expression of ANP was highest in Dimethyl sulfoxide(DMSO) and Woohwangcheungsimweun treatment groups. The expression of GATA-4 was relatively high in wild ginseng treatment group. The expression of TnI was highest in Woohwangcheungsimweun treatment group. In the gene expression analysis, DMSO greatly inhibited GATA-4 expression to 25% of control. Woohwangcheungsimweun treatment caused to increase cTnI and cardiac ANP expression significantly. Wild ginseng extract upregulated GATA-4 gene expression. In conclusion, DMSO widely used as cardiomyocyte differentiation inducer did not show significant effects on the expression of ANP, GATA-4 and TnI in this study. Woohwangcheungsimweun showed upregulation of ANP and TnI expression. Wild ginseng extract showed greater effects than DMSO on GATA-4 expression. These results might suggest that the combination of Woohwangcheungsimweun and wild ginseng extract treatment can be expected to increase expressions of all three genes.

IEC 60364기반 건축전기설비 점검기법 개발을 위한 현장실태 조사 (An Investigation into the Actual Condition of Electrical Equipments Installation for the Inspection Method Development Based on IEC 60364)

  • 정진수;한운기;이한상
    • 조명전기설비학회논문지
    • /
    • 제23권5호
    • /
    • pp.36-41
    • /
    • 2009
  • 본 논문에서는 건축물 전기설비의 IEC 60364를 기반으로 개발된 점검기법을 이용하여 실태 조사를 실시하였다. 점검기법 개발을 위한 분석대상은 기술기준에 준하여 시공된 국내 건축전기설비와 IEC 60364로 시공된 건축전기설비를 대상으로 차이점을 분석하였다. 측정 요소는 Loop impedance, 차단기 동작특성, 보호도체의 연속성을 측정하였다. 조사결과 국내 건축전기설비의 경우 TT시스템과 유사하지만 보호도체의 연속성에 문제가 있었다. TN-C-S로 시공된 건축전기설비의 경우 시공은 정확하게 되어 있었으나 담당자의 IEC 60364와 관련된 이해가 부족한 상태였다.