• Title/Summary/Keyword: TN System

Search Result 430, Processing Time 0.022 seconds

Amplified synthesis and stability of Tn5 polypeptides in escherichia coli (대장균에서의 Tn5 단백질 증폭생합성 및 안정성)

  • 정재성;정재훈
    • Korean Journal of Microbiology
    • /
    • v.27 no.4
    • /
    • pp.323-333
    • /
    • 1989
  • Plasmid DNA molecules containing strong promoter upstream from IS50L or IS50R, the two insertion sequences that flank Tn5, were constructed to amplify the synthesis of Tn5-encoded polypeptides. When proteins made by cells that contain these plasmids were analyzed on polyacrylamide gels, enhanced synthesis of IS50R polypeptides could be detected. Synthesis of this polypeptide apparently is initiated within the large open reading frame of this element. In addition, the stability of IS50L-and IS50R-encoded polypeptides was analyzed. It was found that IS50L polypeptides are relatively unstable in vivo. This instability could account for the observed inability of this element to promote transposition.

  • PDF

EO performance of TN cell on the inorganic films surface using DuoPIGatron ion source on NDLC thin film (무기박막표면에 DuoPIGatron 이온소스를 이용한 TN-LCD 셀의 전기광학 특성)

  • Kim, Byoung-Yong;Hwang, Jeoung-Yeon;Kim, Sang-Hun;Han, Jung-Min;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.432-433
    • /
    • 2006
  • Electro-optical (EO) characteristics of twisted nematic (TN) - liquid crystal display (LCD) on the NDLC thin film using obliquely ion beam (IB) exposure as new ion beam (IB) type system (DuoPIGatrion ion source). A good uniform alignment of the nematic liquid crystal (NLC) alignment with the ion beam exposure on the NDLC thin film was observed. In addition, it can be achieved the good EO properties of the ion-beam-aligned TN-cell on polyimide surface ; the stable VT curve in the ion-beam-aligned TN cell on the NDLC thin film with ion beam exposure using new type IB equipment was obtained. and the fast response time in the ion-beam-aligned TN cell on the NDLC thin film with ion beam exposure using new type IB equipment was obtained.

  • PDF

Study on Introduction to Predicting Indicator of Cyanobacteria Dominance in Algae Bloom Warning System of Hangang Basin (한강유역 조류경보제에 남조류 우점 예측인자 도입에 관한 연구)

  • Kim, Tae Kyun;Choi, Jae Ho;Lee, Kyung Ju;Kim, Young Bae;Yu, Sung Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.5
    • /
    • pp.378-385
    • /
    • 2014
  • The chlorophyll-a concentration in algae bloom warning system of Hangang basin did not predict the cyanobacteria dominance. In this study, suggest the predicting indicator of cyanobacteria dominance through analyzing the environmental factors affecting on the cell count of cyanobacteria. Firstly, the dominance of algae was analyzed with seasonal variation during Jan. 2012~Sep. 2013. The diatom dominated phytoplankton communities during the period of January~April. In the May~June, the green algae dominated. And, the dominance of algae was changed to cyanobacteria in the July~August. Also, the environmental factors affecting to cyanobacteria blooms ; nutrients (TN, TP), temperature, precipitation, dam-discharge were evaluated during the study period. Rather than temperature factor, relatively low dam discharge causes cyanobacteria to grow rapidly and create a blooms. The low dam-discharge may increase the water retention time. Finally, it is proved that a low ratio of TN to TP (<29:1) can favour the development of cyanobacteria blooms. Thus, the predicting indicator (TN:TP) have need to apply to the alarm bloom warning system of Hangang basin.

Problems and Inprovement Method of Grounding System in Electrical Facilities (건축전기설비에 적용되는 접지시스템 문제점과 개선방안)

  • Chung, Young-Ki;Kwak, Hee-Ro;Shin, Hyo-Sub;Chung, Chun-Byoung;Nam, Taik-Joo
    • Electric Engineers Magazine
    • /
    • v.228 no.8
    • /
    • pp.52-57
    • /
    • 2001
  • Presently the Korean grounding system uses TN system, multi-grounding method with IT independent grounding method. Nevertheless TN system can't exist with TT system in the technological terms. If they coexist, it causes ground-fault circuit not to operate, and brings about different electrical potential rise by customer system. It brings about serious problems for safety. This paper aims for improving method of grounding system based on the technical analysis on instances in foreign countries and Korea. Almost standards and construction manner were apt to be internationalized after WTO/TBT agreement was concluded. The internal grounding systems should meet the international criteria and reliability for safety, and be provided with technologically impeccable standards.

  • PDF

Protection ability for lightning surge according to the grounding system of low voltage power systems (저압 전원계통 접지방식별 뇌서지보호성능)

  • Lee, Bok-Hee;Lee, Gyu-Sun;Choi, Jong-Hyuk;Yoo, Yang-Woo;Kim, Dong-Sung;Kang, Sung-Man;Ann, Chang-Hwan
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.343-346
    • /
    • 2009
  • The grounding system of low voltage power systems is TT grounding system in Korea. In order to follow the international standard, TN grounding system is adopted. However, the performance of grounding systems has not been evaluated. This paper deals with the experimental results of protection ability of grounding system when lightning surge invades to the neutral line of low voltage power system. As a result, the TT grounding system is most frail for the lightning surge and it does not protect the electrical devices. On the other hand, the TN grounding system perfectly protects the electrical equipment and prevents the electric shock for human through the equipotential bonding. In case of TN system with supplement grounding, it is very important to lower the supplement grounding resistance to protect the electrical equipment and electric shock for human.

  • PDF

Estimate of Nitrous Oxide Emission Factors from Municipal Wastewater Treatment Plants (하수처리 공정별 아산화질소(N$_2$O) 배출계수 산정)

  • Yang, Hyung-Jae;Park, Jung-Min;Kim, Min-Jung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.12
    • /
    • pp.1281-1286
    • /
    • 2008
  • Nitrous oxide(N$_2$O) is well known as a greenhouse gas that contributes to the global warming (310 times more per molecule than carbon dioxide) and to the destruction of the ozone layer. The objective of this study is to estimate N$_2$O emission factor using an emission isolation flux chamber from municipal wastewater treatment plants. N$_2$O gas was analysed by GC/ECD with 6 port gas sampling valve. The results of this study were as follows. N$_2$O emission factor of 5-Stage process from Y wastewater treatment plants was lowest as 0.94 g-N$_2$O/kg-TN. And that of other processes were 2.65 g-N$_2$O/kg-TN for Activated sludge process, 9.30 g-N$_2$O/kg-TN for Denipho process, and 26.73 g-N$_2$O/kg-TN for Sequencing Batch Reactor process. We have known that 5-Stage process is most appropriate process to reduce greenhouse for municipal wastewater treatment plants.

The hydrologic flux of SS, TN and TP in Nakdong River Basin (낙동강 유역 SS, TN, TP 수문학적 플럭스)

  • Lee, Ayeon;Choi, Daegyu;Kim, Tae-Woong;Kim, Sangdan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.6B
    • /
    • pp.551-560
    • /
    • 2010
  • This study presents the export of constituent transport loads through a river system. The proposed constituent transport load estimating procedure can be operated with the on-going Korean TMDL monitoring system. This study firstly discusses the use of a hydrologic simulation model (TANK) to estimate stream-flow for the 40 sub-catchments. Model parameters are estimated from 8-days intervals flow data which has been monitored by NIER since 2004. Constituent transport loads are estimated with the 7-parameter log linear model whose parameters are estimated by the minimum variance unbiased estimator. Results from Nakdong river basin reveals that the proposed procedure provides satisfactory TN, TP and SS transport load estimates. As an application, a representative load duration curve is derived to represent the overall hydrologic flux of TN, TP and SS at Nakdong river basin.

Comparison of Seasonal Nitrogen Removal by Free-Water Surface Wetlands Planted with Iris pseudacorus L. (노랑꽃창포 자유수면습지의 계절에 따른 질소제거 비교)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.14 no.1
    • /
    • pp.121-132
    • /
    • 2011
  • Removal rates of $NO_3$-N and TN in the free-water surface wetland system during winter; December, January, February and March, spring and fall; April, May, October and November, and summer; Jun, July, August and September were investigated. The system was established on floodplain in the downstream reach of the Gwangju Stream in 2008. It measures 50 meters in length and 5.5 meters in width. Iris pseudacorus L. grown in pots for about two years were planted in the system. The water stream was funneled in by gravity and its effluent was discharged back in. Volumes and water quality of inflow and outflow were analyzed from December 2008 to November 2010. The inflow was averaged approximately 350 $m^3/day$ and hydraulic residence time was about 3 hours. Average influent and effluent $NO_3$-N concentration was 3.75 and 3.35 mg/L, respectively and $NO_3$-N retention was amounted to 10.6%. Influent and effluent TN concentration were averaged 4.93 and 4.30 mg/L, respectively and TN abatement reached to 12.9%. One-way ANOVA statistics claimed that the average removal rates of $NO_3$-N and TN during winter, spring and fall, and summer were not always the same (p<0.001). The t-Tests of three pairs among $NO_3$-N removal rates of winter, spring and fall, and summer illustrated that the removal rates of winter ($5.04{\pm}1.94$), spring and fall ($10.53{\pm}2.24$), and summer ($18.61{\pm}2.26$) were significantly different each others (p<0.001). Among TN removal rates, the three pairs of t-Tests of three seasons showed that the removal rates of winter ($5.21{\pm}2.51$), spring and fall ($11.71{\pm}3.12$), and summer ($21.53{\pm}4.86$) were significantly different from each others (p<0.001).

Estimation of Nonpoint Pollutant Removal Capacity in the Buffer Strip with AnnAGNPS Model (AnnAGNPS 모형을 이용한 수변구역의 비점오염물질 제거능 산정)

  • Park, Yun Hee;Kim, Tae Geun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.5
    • /
    • pp.22-31
    • /
    • 2006
  • AnnAGNPS model would be applied to simulate the pollutant removal capacity with the buffer strip in the Deachung reservoir watershed. In 2002, 2,270 tons of TN and 221 tons of TP were discharged from the nonpoint source pollutants in this watershed. During the rainy season, from June to September, 66.4% of TN and 71.9% of TP resulted from nonpoint source loads. AnnAGNPS model was also used to simulate the nutrients removal capacity from the buffer strip under the condition that the present landuse would be changed to forest. As the result of simulation, the removal rates of nutrients from the buffer strip of Daecheong reservoir watershed are 406 tons of TN, 39 tons of TP, which means reduction rates are TN 17.9%, TP 17.8%, respectively.

Estimation of Nonpoint Pollutant Loads in the Hwanggujichoen Basin using SWMM (SWMM을 이용한 황구지천유역의 비점원오염부하량 평가)

  • Cho, Jae-Heon;Cho, Nam-Heung
    • Journal of Environmental Impact Assessment
    • /
    • v.12 no.5
    • /
    • pp.349-358
    • /
    • 2003
  • Water pollution of Hwanggujicheon stream is severe because urban area of Suwon City is included in the basin. A countermeasure for water quality prevention of the stream is necessary. In this study, nonpoint pollutant load of BOD, SS, TN and TP are estimated using SWMM. The result indicates that BOD, SS, TN and TP loads during 3 months from July to September are 67.0%, 60.8%, 54.7% and 74.5% of the annual total load, respectively. We can see that most of nonpoint pollutant loads are generated in the rainy season. Annual nonpoint pollutant loads of BOD, SS, TN and TP in the Hwanggujicheon stream are 342 ton, 1,500 ton, 480 ton and 12.6 ton, respectively.