• Title/Summary/Keyword: TLC Technique

Search Result 32, Processing Time 0.051 seconds

Temperature field measurement of convective flow in a Hele-Shaw Cell with TLC and color image processing (TLC와 컬러화상처리를 이용한 Hele-Shaw Cell 내부 대류 온도장 측정)

  • Yun, Jeong-Hwan;Do, Deok-Hui;Lee, Sang-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.3
    • /
    • pp.1114-1122
    • /
    • 1996
  • Variation of temperature field in a Hele-Shaw convection cell was measured by using a HSI true color image processing system and TLC(Thermochromic Liquid Crystal) solution. The relationship between the hue value of TLC color image and real temperature was obtained and this calibration result was used to measure the true temperature. The temperature field in the Hele-Shaw convection cell shows periodic characteristics of 45 sec at Ra = 9.3 * 10$\^$6/. The temperature field measurement technique developed in this study was proved to be a useful and powerful tool for analyzing the unsteady thermal fluid flows.

Simultaneous velocity and temperature measurement of thermo-fluid flows by using particle imaging technique (화상처리기법을 이용한 온도장 및 속도장 동시 측정기법 개발)

  • Lee, Sang-Joon;Baek, Seung-Jo;Yoon, Jong-Hwan;Doh, Deog-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.10
    • /
    • pp.3334-3343
    • /
    • 1996
  • A quantitative flow visualization technique was developed to measure velocity and temperature fields simultaneously in a two-dimensional cross section of thermo-fluid flows. Thermochromic liquid crystal(TLC) particles are used as temperature sensor and velocity tracers. Illuminating a thermo-fluid flow with a thin sheet of white light, the reflected colors from the TLC particles in the flow were captured simultaneously by two CCD cameras; a 3-chip CCD color camera for temperature field measurement and a black and white CCD camera for velocity field measurement. Variations of temperature field were measured by using a HSI true color image processing system and TLC solution. The relationship between the hue values of TLC color image and real temperature was obtained and this calibration curve was used to measure the true temperature under the same camera and illumination condition. The velocity field was obtained by using a 2-frame PTV technique using the concept of match-probability to track true velocity vectors from two consecutive image frames. These two techniques were applied at the same time to the unsteady thermal-fluid flow in a Hele-Shaw cell to measure the temperature and velocity field simultaneously and some results are discussed.

Application of the $^{32}$P-Postlabelling Technique : A Study on Detection of DNA Adduct Induced by Azo Dyes rind Flavonoid Compounds ($^{32}$P-Postlabelling 방법의 응용 : Azo색소 및 Flavonoid화합물에 의해 유도되는 DNA Adduct의 겸출에 관한 연구)

  • 김재현;박창원;박정식;홍연탁;김효정;이주한;이헌수;이동권
    • Biomolecules & Therapeutics
    • /
    • v.1 no.1
    • /
    • pp.58-64
    • /
    • 1993
  • DNA addicts induced by putative chemical related to carcinogenesis were detected and determined by $^{32}$P-Postlabelling assay after exposure of 4 compounds comprising two auto dyes (amaranth, new coccine) and two flavonoid compounds (rutin, quercetin) to ICR mouse. DNA was isolated from mouse liver and digested enzymatically to deoxyribonucleoside 3'-monophosphate. The postincubation of DNA digests with nuclease Pl before $^{32}$P-labelling enhanced the technique's sensitivity. Nuclease Pl cleaves deoxyribonucleoside 3'-mono-phosphates of normal nucleotides to deoxyrihonucleosides which do not serve as substrates for polynucleotide kinase, while most of addicts were found to be totally or partially resistant to the 3'-dephosphorylating action of nuclease Pl. The adducted deoxyribonucleoside 3'-monophosphate was converted to 5'-$^{32}$P-labelled deoxynucleoside 3',5'-bisphosphate by T4 polynucleotide kinase. The nucleotides were separated by anion-exchange thin layer chromatography(TLC) on polyethyleneimine cellulose by 4-dimensional or 2-dimensional TLC then detected by autoradiography. The results show that DNA addicts were detected in liver DNA of ICR mouse after administration of amaranth and quercetin by 2-dimensional and/or 4-dimensional TLC.

  • PDF

Improvements of Temperature Field Measurement Technique using Neural Network (신경망을 이용한 온도장 측정법 개선 방안)

  • Hwang Tae Gyu;Moon Ji Seob;Chang Tae Hyun;Doh Deog Hee
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.52-55
    • /
    • 2004
  • Thermo-chromic Liquid Crystal(TLC) particles were used as temperature sensor for thermal fluid flow. $1K\times1K$ CCD color camera and Xenon Lamp(500W) were used for the visualization of a Hele-Shaw cell. The characteristic between the reflected colors from the TLC and their corresponding temperature shows strong non-linearity. A neural network known as having strong mapping capability for non-linearity is adopted to quantify the temperature field using the image of the flow. Improvements of color-to-temperature mapping was attained by using the local color luminance (Y) and hue (H) information as the inputs for the constructed neural network.

  • PDF

Cosmical Analysis and Interfacial Characterization of Biosurfactants formed by Rhodococcus. Sp. strain IGTS8 during the Biodesulfurization Process (미생물 탈황 공정 중 Rhodococcus sp. strain IGTS8에 의하여 생성되는 Biosurfactants의 성분 분석 및 계면특성)

  • 박홍우;박기돈;오성근
    • KSBB Journal
    • /
    • v.17 no.3
    • /
    • pp.302-306
    • /
    • 2002
  • The chemical analysis and surface chemical properties of biosurfactant formed by Rhodococcus sp. strain IGTS8, which is widely used in biodesulfurization process, in hexadecane/water mixture have been studied. For the chemical analysis, TLC technique was employed. The surface tension, CMC, and emulsion stability of biosurfactant solution were also investigated. The major components of biosurfactant formed by Rhodococcus sp. strain IGTS8 were glucose mycolate and trehalose monomycolate. The CMC of aqueous biosurfactant solution was 0.1 ~0.15 g/100 mL of Water at pH 6.0-6.5 and pH 10~10.5. But the demulsification was faster at pH 10 than at pH 6.3.

The Screening of Polyacetylenic Compounds in Korean Plants. I. (한국산 식물중 Polyacetylene계 화합물의 검색(I))

  • 문창규;윤미훈
    • YAKHAK HOEJI
    • /
    • v.20 no.1
    • /
    • pp.44-46
    • /
    • 1976
  • Fourteen species of umbelliferae-plants grown in Korea were examined for the presence of polyacetylenic compounds. By using the UV and IRspectrometric technique combined with TLC, the presence of polyacetylenic compounds was identified in Phellopterus littoralis $B_{ENTHAM}$ Peucedanum japonicum $T_{HUNBERG}$ and Angelica koreana $M_{AXIMOWITZ}$.

  • PDF

Comparison of methods for Determination of Aflatoxins in food Products (식품중 Aflatoxin 측정방법의 비교)

  • 김면희
    • Journal of Food Hygiene and Safety
    • /
    • v.11 no.2
    • /
    • pp.149-157
    • /
    • 1996
  • A procedure for the determination of Aflatoxins in food and grains which utilizes reversed phased liquid chromatographic (LC) analysis with postcolumn derivatization by an electrochemical cell and determination with a fluorescence detector has been evaluated. The LC mobile phase was water-acetonitrile-methanol (6+2+2) with 1mM KBr and 1 mM HNO3 which gave baseline separation for the four Aflatoxins (AfB1, AfB2, AfG1, AfG2). The electrochemical cell set at 7V, generated bromine and derivatized aflatoxins B1 and G1, The derivatives were detected by the fluorescence detector. The aflatoxins in naturally contaminated corn samples were isolated by three different cleanup procedures: the AOAC method I column(CB method), a rapid filtrate column (Romer's column), and an immunoaffinity column. The final extract were quantitated with fluordensitometric TLC and the LC postcolumn derivatization techniques. The results were quite similar, however the LC technique showed less interferences and could be automated. Samples of corn, raw peanuts, peanut butter and dried dates were also analyzed successfully with this procedure.

  • PDF

Temperature Field Measurement of Ventilation Flow in a Vehicle Interior (TLC와 컬러화상처리를 이용한 자동차 실내 환기유동의 온도장 측정)

  • 윤정환;이상준;김기원
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.1
    • /
    • pp.120-128
    • /
    • 1997
  • The variations of the temperature field in a passenger compartment were measured by using a HSI true color image processing system and TLC(Thermochromic Liquid Crystal) solution. This temperature measurement technique was proved to be useful for analyzing the ventilation flow. The flow field in the passenger compartment was visualized using a particle streak method with pulsed laser light sheet. The temperature field and flow field in the passenger copartment were affected significantly by the ventilation mode. The panel-vent mode heating had shorter elapse time to reach a uniform temperature than the foot-vent mode under the same ventilation condition and nonuniformity inside the passenger compartment could be minimized effectively by using the bilevel heating mode. The temperature increase rate in the rear passenger compartment was iower than the front compartment, especially in the vicinity of the rear seat occupants' knee level.

  • PDF

Effects of dimple/protrusion array on heat transfer coefficients in rectangular wavy duct (주름진 덕트에서 딤플/돌출 형상이 열전달계수에 미치는 영향)

  • Kwon, Hyun-Goo;Hwang, Sang-Dong;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2352-2356
    • /
    • 2008
  • Heat transfer and performance characteristics have been investigated for a rectangular wavy duct with dimple or protrusion arrays. The test duct was 15mm in height and 105mm wide. The print diameter of the dimple/protrusion wall was 12.99mm and the depth/height of the dimple/protrusion was 3.75mm. Local heat transfer coefficients on the dimple/protrusion wall were measured using a transient TLC technique. The Reynolds number was varied from 3,000 to 10,000. For the wavy duct tested in this study, adverse static pressure characteristics occurred at turning region of the wavy duct due to secondary flows. For the wavy duct with protrusion array, higher heat transfer enhancement level of 7.4 times than smooth straight case in maximum was obtained at low Reynolds number due to the high heat transfer enhancement by vortex flows. Also, the protrusion array increased the performance level of 3.0 at low Reynolds number of 3,000.

  • PDF

Improvements of Temperature Field Measurement Technique using Neural Network (신경망 적용의 온도장 측정법 개선 방안)

  • Doh Deog Hee;Kim Dong Hyuk;Bang Kwang Hyun;Moon Ji Seob;Hong Seong Dae;Chang Tae Hyun;Hwang Tae Gyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.2
    • /
    • pp.209-216
    • /
    • 2005
  • Thermo-chromic Liquid Crystal(TLC) particles were used as temperature sensor for thermal fluid flow. 1K $\times$ 1K CCD color camera and Xenon Lamp(500w) were used for the visualization of a Hele-Shaw cell The characteristic between the reflected colors from the TLC and their corresponding temperature shows strong non-linearity A neural network known as having strong mapping capability for non-linearity is adopted to quantify the temperature field using the image of the flow. Improvements of color-to-temperature mapping was attained by using the local color luminance (Y) and hue (H) information as the inputs for the constructed neural network.