• Title/Summary/Keyword: TL

Search Result 1,453, Processing Time 0.025 seconds

The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan (전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Ryu, Jae-Kwang;Yoo, Jae-Sook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • Purpose: In Asan Medical Center we perform myocardial perfusion SPECT to evaluate cardiac event risk level for non-cardiac surgery patients. In case of patients with cancer, we check tumor metastasis using whole body bone scan and whole body PET scan and then perform myocardial perfusion SPECT to reduce unnecessary exam. In case of short term in patients, we perform $^{201}Tl$ myocardial perfusion SPECT after whole body bone scan a minimum 16 hours in order to reduce hospitalization period but it is still the actual condition in which the evaluation about the affect of the crosstalk contamination due to the each other dissimilar isotope administration doesn't properly realize. So in our experiments, we try to evaluate crosstalk contamination influence on $^{201}Tl$ myocardial perfusion SPECT using anthropomorphic torso phantom and patient's data. Materials and Methods: From 2009 August to September, we analyzed 87 patients with $^{201}Tl$ myocardial perfusion SPECT. According to $^{201}Tl$ myocardial perfusion SPECT yesterday whole body bone scan possibility of carrying out, a patient was classified. The image data are obtained by using the dual energy window in $^{201}Tl$ myocardial perfusion SPECT. We analyzed $^{201}Tl$ and $^{99m}Tc$ counts ratio in each patients groups obtained image data. We utilized anthropomorphic torso phantom in our experiment and administrated $^{201}Tl$ 14.8 MBq (0.4 mCi) at myocardium and $^{99m}Tc$ 44.4 MBq (1.2 mCi) at extracardiac region. We obtained image by $^{201}Tl$ myocardial perfusion SPECT without gate method application and analyzed spatial resolution using Xeleris ver 2.0551. Results: In case of $^{201}Tl$ window and the counts rate comparison result yesterday whole body bone scan of being counted in $^{99m}Tc$ window, the difference in which a rate to 24 hours exponential-functionally notes in 1:0.114 with Ventri (GE Healthcare, Wisconsin, USA), 1:0.249 after the bone tracer injection in 12 hours in 1:0.411 with 1:0.79 with Infinia (GE healthcare, Wisconsin, USA) according to a reduction a time-out was shown (Ventri p=0.001, Infinia p=0.001). Moreover, the rate of the case in which it doesn't perform the whole body bone scan showed up as the average 1:$0.067{\pm}0.6$ of Ventri, and 1:$0.063{\pm}0.7$ of Infinia. According to the phantom after experiment spatial resolution measurement result, and an addition or no and time-out of $^{99m}Tc$ administrated, it doesn't note any change of FWHM (p=0.134). Conclusion: Through the experiments using anthropomorphic torso phantom and patients data, we found that $^{201}Tl$ myocardium perfusion SPECT image later carried out after the bone tracer injection with 16 hours this confirmed that it doesn't receive notable influence in spatial resolution by $^{99m}Tc$. But this investigation is only aimed to image quality, so it needs more investigation in patient's radiation dose and exam accuracy and precision. The exact guideline presentation about the exam interval should be made of the validation test which is exact and in which it is standardized about the affect of the crosstalk contamination according to the isotope use in which it is different later on.

  • PDF

Image Quality Evaluation of CsI:Tl and Gd2O2S Detectors in the Indirect-Conversion DR System (간접변환방식 DR장비에서 CsI:Tl과 Gd2O2S의 검출기 화질 평가)

  • Kong, Changgi;Choi, Namgil;Jung, Myoyoung;Song, Jongnam;Kim, Wook;Han, Jaebok
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.27-35
    • /
    • 2017
  • The purpose of this study was to investigate the features of CsI:Tl and $Gd_2O_2S$ detectors with an indirect conversion method using phantom in the DR (digital radiography) system by obtaining images of thick chest phantom, medium thickness thigh phantom, and thin hand phantom and by analyzing the SNR and CNR. As a result of measuring the SNR and CNR according to the thickness change of the subject, the SNR and CNR were higher in CsI:Tl detector than in $Gd_2O_2S$ detector when the medium thickness thigh phantom and thin hand phantom were scanned. However, when the thick chest phantom was used, for the SNR at 80~125 kVp and the CNR at 80~110 kVp in the $Gd_2O_2S$ detector, the values were higher than those of CsI:Tl detector. The SNR and CNR both increased as the tube voltage increased. The SNR and CNR of CsI:Tl detector in the medium thickness thigh phantom increased at 40~50 kVp and decreased as the tube voltage increased. The SNR and CNR of $Gd_2O_2S$ detector increased at 40~60 kVp and decreased as the tube voltage increased. The SNR and CNR of CsI:Tl detctor in the thin hand phantom decreased at the low tube voltage and increased as the tube voltage increased, but they decreased again at 100~110 kVp, while the SNR and CNR of $Gd_2O_2S$ detector were found to decrease as the tube voltage increased. The MTF of CsI:Tl detector was 6.02~90.90% higher than that of $Gd_2O_2S$ detector at 0.5~3 lp/mm. The DQE of CsI:Tl detector was 66.67~233.33% higher than that of $Gd_2O_2S$ detector. In conclusion, although the values of CsI:Tl detector were higher than those of $Gd_2O_2S$ detector in the comparison of MTF and DQE, the cheaper $Gd_2O_2S$ detector had higher SNR and CNR than the expensive CsI:Tl detector at a certain tube voltage range in the thick check phantom. At chest X-ray, if the $Gd_2O_2S$ detector is used rather than the CsI:Tl detector, chest images with excellent quality can be obtained, which will be useful for examination. Moreover, price/performance should be considered when determining the detector type from the viewpoint of the user.

Evaluation of Glioma with Thallium-201 Brain SPECT: The Correlation with $^1H$ MR Spectroscopy and Pathology ($^{201}Tl$ 뇌 SPECT을 이용한 신경교종의 평가)

  • Sohn, Hyung-Sun;Kim, Euy-Neyng;Kim, Sung-Hoon;Yoo, Ie-Ryung;Chung, Yong-An;Chung, Soo-Kyo;Hong, Yong-Gil;Lee, Youn-Soo;Choe, Bo-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.465-477
    • /
    • 2000
  • Purpose: Thallim-201 ($^{201}Tl$) brain SPECT and proton ($^1H$) magnetic resonance spectroscopy (MRS) have been used to evaluate tumor grade and viability of glioma. We assessed the correlations between $^{201}Tl$ brain index or spectrum of metabolites of $^1H$ MRS and grade of glioma or histopathologic findings. Materials and Methods: We studied 17 patients (4 astrocytoma, 7 anaplastic astrocytoma and 6 glioblastoma). On $^{201}Tl$ Brain SPECT, $^{201}Tl$ index was measured as the ratio of average counts for region of interest to those for the contralateral normal brain. On $^1H$ MRS, we calculated choline (Cho) /creatine (Cr) ratio and N-acetylaspartate (NAA)/Cr ratio in ROI defined as tumor center. Histopathologic findings were graded by Ki-67 index, cellularity, mitosis, pleomorphism, necrosis and endothelial proliferation. An unpaired t test and statistical correlations were performed to evaluate these data. Results: Tl-index showed the best correlation with Ki-67 index (p<0.01), less correlations with cellularity, mitosis, and endothelial proliferation, but no correlation with results of MRS, pleomorphism, or necrosis. The findings of MRS did not correlate with all of the above. The cases of glioblastoma demonstrated a higher Tl-index, Cho/cr ratio, Ki-67 index and lower NAA/Cr ratio, albeit without statistical significance. Conclusion: Even though $^{201}Tl$ brain SPECT did not correlate directly with grade of malignancy, it may still be useful in determining biological aggressiveness of tumor and prognosis of patients because it correlated well with Ki-67 index, a growth fraction of glioma, cellularity, mitosis and endothelial proliferation.

  • PDF

Maturity and Spawning of Marbled Sole Pleuronectes yokohamae in the Southern Sea of Korea (한국 남해안 문치가자미, Pleuronectes yokohamae의 성숙과 산란)

  • Seo, Youn-Il;Joo, Hyu;Lee, Sun-Kil;Kim, Hee-yong;Ko, Joon-Chul;Choi, Mun-Sung;Kim, Joo-Il;Oh, Tag-Yun
    • Korean Journal of Ichthyology
    • /
    • v.22 no.2
    • /
    • pp.83-89
    • /
    • 2010
  • We studied the maturity and spawning of Marbled sole Pleuronectes yokohamae from May 2006 to April 2007 in the Southern Sea of Korea. We analyzed monthly changes in maturity stages, gonadosomatic index (GSI), egg diameters, fecundity (F), total length (TL) at 50% group maturity, and sex ratio. The spawning period was November to February, and the main spawning period was December to January. The fecundity ranged from 75,155 eggs at 17.8 cm(TL) to 1,307,195 eggs at 36 cm (TL), and the relationship between TL and F was $F=3.656TL^{3.518}$ ($R^2$=0.872). The TL at first maturity was 17.8 cm and at 100% maturity, 32 cm. Thus, TL at 50% group maturity was estimated to be 19.8 cm. For sex ratio by length class, males were slightly predominant at sizes under 25 cm TL, but females were 100% at greater than 32 cm TL.

Physical Habitat Assessment of Pale Chub (Zacco platypus) to Stream Orders in the Geum River Basin (하천차수에 따른 금강수계 피라미(Zacco platypus)의 물리적 서식지 평가)

  • Hur, Jun-Wook;Park, Sang-Young;Kang, Shin-Uk;Kim, Jeong-Kon
    • Korean Journal of Environmental Biology
    • /
    • v.27 no.4
    • /
    • pp.397-405
    • /
    • 2009
  • We assessed the physical habitat conditions of pale chub (Zacco platypus) considering various stream order in the Geum river basin. Field monitoring was conducted for ecological and habitat conditions for 28 sites from October 2007 to October 2008. The number of Z. platypus sampled during this period was 2,362. In more than 3rd stream, water depth and velocity showing the highest number of samples were 0.8 m and $0.8\;m\;s^{-1}$, respectively. In addition, the highest number of samples was observed under the condition of total length (TL) (8~10 cm), velocity ($0.3\;m\;s^{-1}$), water depth (0.4 m), substrate size (send, 0.1~1.0 mm~coarse gravel, 50.0~100.0 mm) and habitat type (run). Based on the monitoring data (n=1059) the relationship between body weight (BW) and TL in male and female were estimated as $BW=0.0068{\times}TL^{3.0274}$ ($r^2=0.9102$) and $BW=0.0075{\times}TL^{2.9995}$ ($r^2=0.8517$), respectively. Growth equations on days after parturition (DAP) to the TL were estimated as TL=0.0108DAP+1.5795 ($r^2=0.9721$). By equations (TL 6.9 cm), BW were 2.7 g (male) and 2.4 g (female), and DAP was about 490 days.

Study on In Vitro Fertilization of Pig Oocytes Matured in In Vivo and In Vitro (생체(生體) 및 실험실(實驗室)에서 성숙(成熟)된 돼지 난모세포(卵母細胞)의 체외수정(體外受精)에 관(關)한 연구(硏究))

  • Park, Chang Sik;Lee, Kyu Seung;Seo, Kil Woong
    • Korean Journal of Agricultural Science
    • /
    • v.18 no.2
    • /
    • pp.114-118
    • /
    • 1991
  • This study was conducted to find out the suitable in vitro media for fertilization and culture on the pig oocytes matured in vivo and in vitro. The results obtained were as follows; A comparison of fertilization media on the oocytes matured in vivo was made between M199 with 10% FCS versus TL Hepes with 1% BSA Fertilization rate was significantly higher in the TL Hepes medium. But polyspermic incidence did not favor in the TL Hepes medium. Embryos were cultured in TL Hepes wash and culture medium for 48h after insemination. A total of 53 embryos were cultured and 39(73.6%) cleaved. Of these 39 embryos, 31(79.5%) cleaved equally to the 2-8 cell stage. Immature oocytes cultured in Waymouth's maturation medium were much more able to induce sperm swelling than immature oocytes cultured in TL Hepes maturation medium, however, most ova were polyspermic and did not develope to the 4 cell stage during 48h culture in TL Hepes wash and culture medium.

  • PDF

The Influence of Muddy Water in Imha Reservoir on the Ichthyofauna and Fish Growth (임하호의 탁수가 어류상 및 어류생장에 미치는 영향)

  • Han, Seung-Cheol;Lee, Hak-Young;Seo, Eul-Won;Shim, Jae-Hun;Lee, Jong-Eun
    • Journal of Life Science
    • /
    • v.17 no.8 s.88
    • /
    • pp.1104-1110
    • /
    • 2007
  • The number of investigated fish collected from the Andong and the Imha reservoir were 2,540 individuals 20 species belonging to 7 families, 850 individuals 11 species belonging to 4 families respectively from May 2005 to March 2006. The total number of the common 3 species individuals investigated caught from the Andong reservoir and the Imha reservoir were 486 individuals and 124 individuals respectively. The investigated individuals is similar(${\pm}2.5$ mm) to 171 individuals make a comparative study. The Opsariichthys uncirostris, Culter brevicauda, Hemiculter eigenmanni of length-weight relationship were TW = $0.00007TL^{3.0543}$, TW = $0.0000009TL^{3.3654}$, TW = $0.00000^{3.3872}$ in the Andong reservoir and TW = $0.00002TL^{2.8493}$, TW = $0.00001TL^{2.8744}$, TW = $0.000004TL^{3.1082}$ in the Imha reservoir respectively. The Condition factor(K) of the Andong reservoir showed the positive slopes in all three species and to be in a good nutrition condition; where as the condition factor(K) of the Imha reservoir showed the negative slopes in two species except in H. eigenmanni and appeared to be in a little bad nutrition condition. Relative condition factor(Kn) indicating that O. uncirostris and C. brevicauda in Andong reservoir is more rotund than ones of Imha reservoir but H. eigenmanni in the Imha reservoir is more rotund than the ones of the Andong reservoir.

Thermoluminescent Response of Thin LiF:Mg,Cu,Na,Si Detectors to Beta Radiation (얇은 LiF:Mg,Cu,Na,Si 검출기의 베타선장에 대한 TL 반응)

  • Nam, Y.M.;Kim, J.L.;Chang, S.Y.;Cho, H.W.;Kim, H.J.
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.1
    • /
    • pp.39-43
    • /
    • 1999
  • Thermoluminescent (TL) response characteristics of a thin LiF:Mg,Cu,Na,Si Teflon detectors have been studied for use in beta radiation detection. The detectors were fabricated from a mixture of LiF:Mg,Cu,Na,Si phosphor and Teflon powder which was molded into a thin disk form of $50mg/cm^2$ thickness. These detectors were irradiated to beta fields of $^{147}Pm,\;^{204}Tl\;and\;^{90}Sr/^{90}Y$ sources with a covering of Kapton foil ($2mg/cm^2$) and photon irradiation was carried out with a $^{137}Cs$ source at the Korea Atomic Energy Research Institute (KAERI). Batch uniformity was estimated to be 4.7% and the beta dose response presented linear relationship from 0.1 mGy to 100 Gy. The beta energy responses of thin detectors normalized to $^{137}Cs$ were presented as 0.46, 1.09 and 1.06 for $^{147}Pm,\;^{204}Tl\;and\;^{90}Sr/^{90}Y$ beta rays, respectively. The evaluated values for angular responses were $0.93{\pm}0.03\;(^{147}Pm),\;0.94{\pm}0.04\;(^{204}Tl),\;and\;0.92{\pm}0.05\;(^{90}Sr/^{90}Y)$. The results satisfied well a proposed ISO Standard for beta ray dosimeters.

  • PDF

The Measurement and Analysis of LiF:Mg, Cu, Na, Si TL Material by Thermoluminescence Spectrum (LiF:Mg, Cu, Na, Si TL 물질의 열자극발광스펙트럼 측정 및 분석)

  • Lee, J.I.;Moon, J.H.;Kim, D.H.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.149-153
    • /
    • 2001
  • Three-dimensional thermoluminescence(TL) spectra of LiF: Mg, Cu, Na, Si TL material based on temperature, wavelength and intensity were measured and analyzed. The glow curves were obtained by integration of luminescence intensity for wavelength at each temperature, and various trapping parameters related to the trap formation were determined by analyzing these curves. Computerized glow curve deconvolution(CGCD) method which based on general order kinetics(GOK) model were used for the glow curve analysis. The glow curves of LiF:Mg, Cu, Na, Si TL material were deconvoluted to six isolated glow curves which have peak temperature at 333 K, 374 K, 426 K, 466 K, 483 K and 516 K, respectively. The 466 K main glow peak had an activation energy of 2.06 eV and a kinetic order of 1.05. This TL material was also found to have three recombination centers, 1.80 eV, 2.88 eV and 3.27 eV by TL spectra analysis based on Franck-Condon model. It showed that 2.88 eV is the dominant center, followed by 3.27 eV level, and 1.80 eV center is ascertained as emission center of this material even though its very weak emission intensity.

  • PDF

Maturity and Spawning of Korean Flounder Glyptocephalus stelleri (Schmidt) in the East Sea of Korea (동해안 기름가자미 Glyptocephalus stelleri (Schmidt)의 성숙과 산란)

  • Cha, Hyung Kee;Kwon, Hyeok Chan;Lee, Sung Il;Yang, Jae Hyeong;Chang, Dae Soo;Chun, Young Yull
    • Korean Journal of Ichthyology
    • /
    • v.20 no.4
    • /
    • pp.263-271
    • /
    • 2008
  • The maturity and spawning of Korean flounder Glyptocephalus stelleri were investigated using samples randomly collected in the East Sea of Korea from May 2005 to September 2008. Gonadosomatic index began to increase in December and reached a maximum between March and May. After spawning it began to decrease from June. The spawning period was March to June, and the main spawning period was April to May. Annual reproductive cycles of this species can be divided into four successive stages; immature stage (July~November), maturing stage (December~February), mature stage (March~April) and spent stage (May~June). The fecundity ranged from 15,146 eggs at 24.1 cm (TL) to 101,491 eggs at 38.1 cm (TL). The relationship between total length (TL) and fecundity (F) can be expressed as $F=0.0004TL^{3.449}$ ($R^2=0.663$), with F increasing with TL. The TL at 50% group maturity ($TL_{50%}$) was estimated to be 25.6 cm.