• Title/Summary/Keyword: TKA

Search Result 53, Processing Time 0.035 seconds

A Biomechanical Comparative Analysis of the Multi-Radius Total Knee Arthroplastry System for Go up Stair and Go down Stair (계단 오르기와 내리기 동안 다축범위(multi-radius) 무릎인공관절 수술자의 운동역학적 비교분석)

  • Jin, Young-Wan;Yoo, Byung-In;Kawk, Yi-Sub
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.1
    • /
    • pp.31-41
    • /
    • 2006
  • The primary purpose of a TKA is to restore normal knee function Therefore, ideally, a TKA should: (a) maintain the natural leverage of the knee joint muscles to ensure generating adequate knee muscle moments to accomplish daily tasks such as rising from climbing stairs; (b) provide adequate knee joint stability. A 16-channel MyoResearch XP EMG system was used to collect the differential input surface electromyography signals VM, VL, RF, BF, ST during climbing/descending stair tests. A Peak Motion Measurement System was used to collect the kinematic and kinetic data. AKIN-COM Ill isokinetic dynamometer was used for EMG of VM, VL, RF, BF and ST during maximal voluntary contraction. I Quadriceps EMG results for the VM of the passed 1year group limb demonstrated significant less RMS EMG than that of the passed 3year group limb $60^{\circ}-15^{\circ}$ of knee flexion(p<0.05). The VL of the passed 1year group limb also demonstrated significants less RMS EMG than that of the passed 3year group limb from $60^{\circ}-45^{\circ}$ of knee flexion(p<0.05). Similar to the VM and VL, the RF of the passed 1year group limb showed less RMS EMG than that of the passed 3year group limb from $60^{\circ}-30^{\circ}$ do knee flexion(p<0.05). Hamstring EMG results for the BF of the passed 1year group limb demonstrated less RMS EMG than that of the passed 3year group limb from $75^{\circ}-15^{\circ}$ of knee flexion(p<0.05). The passed 1year group limb tended to have less ADD displacement(p<0.071) than that of the passed 3year group limb. There was no significant difference of the ABD displacement between the passed 1year group and the passed 3year group limbs(p<0.73). The passed 3year group used compensatory adaptation movement strategies to compensate for the strength deficit of passed 3year group limbs. The passed 3year group limb also increased the quadriceps muscle activation level to produce more knee extension moment to compensate for the short quadriceps moment arm. The passe 3year group limb might have an unstable knee joint in the medio-Iateral direction during the climbing/descending by showing a tendency of more ADD displacement and greater hamming co-activation EMG than the passed 1year group limbs. The TKA design was not able to help the knee joint to produce adequate knee extension moment with less quadriceps muscle effort. I think that old man needs continuous exercise for muscle strength.

In Vivo Kinematics of a Mobile-bearing Total Knee Prosthesis (이동베어링형 인공무릎전치환관절의 생체내의 운동)

  • Lee, Yeon-Soo;Park, Sang-Jin;Song, Eun-Kyoo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1473-1474
    • /
    • 2008
  • In the total knee arthroplasty (TKA), kinematic benefic of a mobile-bearing total knee prosthesis is still arguing. Main reasons for implant failure are loosening and polyethylene wear and should be solved with new designs with mob ile bearings. The kinematics of the knee prosthesis also affects the implant failure. Recently, a second generation of p rostheses with a mobile-bearing was developed. The current study aimed to assess the kinematic path of the 2nd generation mobile knee prosthesis compared to the normal knees. Using 3D/2D registration method, CT-derived 3D knee models were fitted to sequential 2D X-ray images during knee flexion. 3D kinematics of the femur and the tibia were analyzed. The 2nd generation mobile-bearing TKA prosthesis (e.motion, Aesculap, Germany) knees showed less external rotation and knee flexion range compared to the normal knee, but the trend of external rotation was similar each other.

  • PDF

Treatment of Spinal Infection Following Bilateral Total Knee Replacement Postoperative Infection (척추감염을 동반한 양측 슬관절 전치환술 후 감염의 치료)

  • Shim, Bum-Jin;Sohn, Oog-Jin;Cho, Chang-Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.52 no.1
    • /
    • pp.92-96
    • /
    • 2017
  • Postoperative infection from total knee arthroplasty (TKA) is an issue drawing great attention, which can manifest as a local or general infection. Its development into sepsis has also occasionally been reported. Such sepsis is a critical complication that can spread to various parts of the body, which can ultimately lead to mortality. However, the cases where infection has spread to the spine do not have clear clinical signs, making diagnosis difficult. These cases are not found in the literature. Therefore, this is a case study on both postoperative infection from TKA that has developed into sepsis and spread to the spine.

Clinical Results of Arthroscopic Treatment for Infection after Total Knee Arthroplasty (슬관절 전치환술 후 발생한 감염에 시행한 관절경적 치료의 임상 결과)

  • Kim, Kyung Tae;Lee, Song;Kim, Jee Hyoung;Kim, Dae Geun;Shin, Won Shik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.17 no.1
    • /
    • pp.38-43
    • /
    • 2013
  • Purpose: To evaluate the efficiency of arthroscopic treatment for infected total knee arthroplasty (TKA), and to investigate the factors affecting the outcomes. Materials and Methods: We analyzed 17 cases which underwent arthroscopic treatment to treat infection after TKA. After confirming infection by hematologic examination and analysis of joint fluid, we performed arthroscopic debridement, synovectomy and irrigation with normal saline mixed with antibiotics. Through routine examination after operation, we checked failure of treatment or recurrence of infection. If there is no recurrence until 2 years after the operation, we considered it as a success of treatment. Results: Of the 17 cases taken arthroscopic treatment, 13 cases were treated successfully with primary arthroscopic treatment only, but 4 cases had to undergo re-operation because of persistence or recurrence of infection. Analyzing the factors affecting the results, we found that symptom duration of the re-operation group is longer than the treated group after arthroscopy (p<0.05). Conclusion: Arthroscopic treatment can be effective when we performed appropriate selection of patients, careful and extensive arthroscopic irrigation and debridement, and suitable use of antibiotics. However, we have to do early arthroscopic surgery as soon as possible when infection after TKA is suspected.

  • PDF

Value of Additional Instrumented Fusion in the Treatment of Thoracic Ossification of the Ligamentum Flavum

  • Hwang, Sung Hwan;Chung, Chun Kee;Kim, Chi Heon;Yang, Seung Heon;Choi, Yunhee;Yoon, Joonho
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.5
    • /
    • pp.719-729
    • /
    • 2022
  • Objective : The ossification of the ligamentum flavum (OLF) is one of the major causes of thoracic myelopathy. Surgical decompression with or without instrumented fusion is the mainstay of treatment. However, few studies have reported on the added effect of instrumented fusion. The objective of this study was to compare clinical and radiological outcomes between surgical decompression without instrumented fusion (D-group) and that with instrumented fusion (F-group). Methods : A retrospective review was performed on 28 patients (D-group, n=17; F-group, n=11) with thoracic myelopathy due to OLF. The clinical parameters compared included scores of the Japanese Orthopedic Association (JOA), the Visual analogue scale of the back and leg (VAS-B and VAS-L), and the Korean version of the Oswestry disability index (K-ODI). Radiological parameters included the sagittal vertical axis (SVA), the pelvic tilt (PT), the sacral slope (SS), the thoracic kyphosis angle (TKA), the segmental kyphosis angle (SKA) at the operated level, and the lumbar lordosis angle (LLA; a negative value implying lordosis). These parameters were measured preoperatively, 1 year postoperatively, and 2 years postoperatively, and were compared with a linear mixed model. Results : After surgery, all clinical parameters were significantly improved in both groups, while VAS-L was more improved in the F-group than in the D-group (-3.4±2.5 vs. -1.3±2.2, p=0.008). Radiological outcomes were significantly different in terms of changes in TKA, SKA, and LLA. Changes in TKA, SKA, and LLA were 2.3°±4.7°, -0.1°±1.4°, and -1.3°±5.6° in the F-group, which were significantly lower than 6.8°±6.1°, 3.0°±2.8°, and 2.2°±5.3° in the D-group, respectively (p=0.013, p<0.0001, and p=0.037). Symptomatic recurrence of OLF occurred in one patient of the D-group at postoperative 24 months. Conclusion : Clinical improvement was achieved after decompression surgery for OLF regardless of whether instrumented fusion was added. However, adding instrumented fusion resulted in better outcomes in terms of lessening the progression of local and regional kyphosis and improving leg pain. Decompression with instrumented fusion may be a better surgical option for thoracic OLF.

Effect of Single-injection Femoral Nerve Block Using Real-time Ultrasound on the Postoperative Pain after Bilateral Total Knee Arthroplasty: 0.25% vs 0.5% Levobupivacaine (초음파 유도 하 일회성 넙다리신경블록이 슬관절 전치환술 후 통증에 미치는 영향: 0.25% Levobupivacaine과 0.5% Levobupivacaine 주입의 비교)

  • Kim, Yun Joo;Kim, Youn Jin;Kim, Dong Yeon
    • The Korean Journal of Pain
    • /
    • v.22 no.3
    • /
    • pp.234-240
    • /
    • 2009
  • Background: The purpose of this study was to compare the analgesic effect of 0.25% and 0.5% levobupivacaine for real time ultrasound guided single-injection femoral nerve block for the patients who are undergoing bilateral total knee arthroplasty (TKA). Methods: Femoral nerve block was done to all patients with 20 ml of 0.9% normal saline on one leg and 20 ml of 0.25% levobupivacaine on the other leg for group I (n = 16) and 0.5% levobupivacaine for group II (n = 15) with 1:200,000 epinephrine and using real-time ultrasound and a nerve stimulator. The data concerning the verbal numerical rating scale (VNRS) for each leg, the consumption of the intravenous patient-controlled analgesia (IV PCA) and the demands for the additional analgesics was collected at 0, 1, 6, 12, 24 and 48 hours after the operation. Results: The legs on which femoral nerve block was done with levobupivacaine showed a lower VNRS score than the legs with normal saline in either group I or group II. The VNRS scores between the two legs, the consumption of the IV PCA and the demand for additional analgesics showed no significant differences between the groups. Conclusions: Our results demonstrate that single-injection femoral nerve block using real-time ultrasound with either 0.25% levobupivacaine or 0.5% levobupivacaine 20 ml provides a good effect for the postoperative pain control after TKA.

Evaluation of Biomechanical Stability of Newly Developed Revision Total Knee Arthroplasty through Strain and Stress Distribution Analysis within the Tibia: Finite Element Analysis (경골 내 변형률 및 응력 분포 특성 분석을 통한 새로이 개발된 재치환용 인공슬관절의 생체역학적 안정성 평가: 유한요소해석)

  • Han, Paul;Jang, Young-Woong;Yoo, Oui Sik;Kim, Jung Sung;Kim, Han Sung;Lim, Dohyung
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.14-23
    • /
    • 2013
  • In this study, biomechanical stability of the newly developed revision total knee arthroplasty (rTKA) was evaluated through strain and stress distribution analysis within the implanted proximal tibia using a three-dimensional finite element (FE) analysis. 2000N of compressive load (about 3 times body weight) was applied to the condyle surface on spacer, sharing by the medial (60%) and lateral (40%) condyles simulating a stance phase before toe-off. The results showed that PVMS within the revision total knee arthroplasty and the proximal tibia were less than yield strength considering safe factor 4.0 (rTKA: less than 10%, Cortical bone: less than 70%, Cancellous bone: less than 70%). The materials composed of them and the strain and stress distributions within the proximal tibia were generally well matched with those of a traditional revision total knee arthoplasty (Scorpio TS revision system, Stryker Corp., Michigan, USA) without the critical damage strain and stress, which may reduce the capacity for bone remodeling, leading to bone degeneration. This study may be useful to design parameter improvement of the revision total knee arthoplasty in biomechanical stability point of view beyond structural stability of revision total knee arthoplasty itself.

Reliability and Validity of the Femorotibial Mechanical Axis Angle in Primary Total Knee Arthroplasty: Navigation versus Weight Bearing or Supine Whole Leg Radiographs

  • Kim, Seong Hwan;Park, Yong-Beom;Song, Min-Ku;Lim, Jung-Won;Lee, Han-Jun
    • Knee surgery & related research
    • /
    • v.30 no.4
    • /
    • pp.326-333
    • /
    • 2018
  • Purpose: To evaluate the reliability and validity of the femorotibial mechanical axis angle from radiographs in the weight bearing (WB) and supine positions compared with navigation-measured values. Materials and Methods: Sixty-eight cases of navigation-assisted total knee arthroplasty (TKA) were included. The pre- and postoperative whole leg radiographs (WLRs) in WB and supine positions were compared with the initial and final navigation values. Results: The mean mechanical axis angle from the preoperative WBWLR and navigation were not statistically different (p=0.079) and were correlated strongly with each other (intraclass correlation [ICC], 0.818). However, on postoperative measurements, although the WBWLR and navigation values were not different (p=0.098), they were not correlated with each other (ICC, 0.093). The standard error of measurement was $1.8^{\circ}{\pm}3.6^{\circ}$ for the preoperative WBWLR and $2.5^{\circ}{\pm}4.8^{\circ}$ for the postoperative WBWLR. The validity that was determined by the Bland-Altman plot was not acceptable for both pre- and postoperative measurements. Conclusions: The preoperative WBWLR could provide accurate but not precise measurement value of the femorotibial mechanical axis angle for navigation-assisted TKA, and postoperative measurements in navigation were not comparable with radiographic measurements. The lack of agreement was found between the radiographic and navigation measurements of the coronal alignment regardless of pre- or postoperative evaluation although the accuracy was found acceptable. Level of Evidence : Level 4.