• 제목/요약/키워드: TEST-RETEST RELIABILITY

검색결과 409건 처리시간 0.022초

Test-Retest Reliability of Level-Specific CE-Chirp Auditory Brainstem Response in Normal-Hearing Adults

  • Jamal, Fatin Nabilah;Dzulkarnain, Ahmad Aidil Arafat;Shahrudin, Fatin Amira;Marzuki, Muhammad Nasrullah
    • Journal of Audiology & Otology
    • /
    • 제25권1호
    • /
    • pp.14-21
    • /
    • 2021
  • Background and Objectives: There is growing interest in the use of the Level-specific (LS) CE-Chirp® stimulus in auditory brainstem response (ABR) due to its ability to produce prominent ABR waves with robust amplitudes. There are no known studies that investigate the test-retest reliability of the ABR to the LS CE-Chirp® stimulus. The present study aims to investigate the test-retest reliability of the ABR to the LS CE-Chirp® stimulus and compare its reliability with the ABR to standard click stimulus at multiple intensity levels in normal-hearing adults. Subjects and Methods: Eleven normal-hearing adults participated. The ABR test was repeated twice in the same clinical session and conducted again in another session. The ABR was acquired using both the click and LS CE-Chirp® stimuli at 4 presentation levels (80, 60, 40, and 20 dBnHL). Only the right ear was tested using the ipsilateral electrode montage. The reliability of the ABR findings (amplitudes and latencies) to the click and LS CE-Chirp® stimuli within the same clinical session and between the two clinical sessions was calculated using an intra-class correlation coefficient analysis (ICC). Results: The results showed a significant correlation of the ABR findings (amplitude and latencies) to both stimuli within the same session and between the clinical sessions. The ICC values ranged from moderate to excellent. Conclusions: The ABR results from both the LS CE-Chirp® and click stimuli were consistent and reliable over the two clinical sessions suggesting that both stimuli can be used for neurological diagnoses with the same reliability.

Test-Retest Reliability of Level-Specific CE-Chirp Auditory Brainstem Response in Normal-Hearing Adults

  • Jamal, Fatin Nabilah;Dzulkarnain, Ahmad Aidil Arafat;Shahrudin, Fatin Amira;Marzuki, Muhammad Nasrullah
    • 대한청각학회지
    • /
    • 제25권1호
    • /
    • pp.14-21
    • /
    • 2021
  • Background and Objectives: There is growing interest in the use of the Level-specific (LS) CE-Chirp® stimulus in auditory brainstem response (ABR) due to its ability to produce prominent ABR waves with robust amplitudes. There are no known studies that investigate the test-retest reliability of the ABR to the LS CE-Chirp® stimulus. The present study aims to investigate the test-retest reliability of the ABR to the LS CE-Chirp® stimulus and compare its reliability with the ABR to standard click stimulus at multiple intensity levels in normal-hearing adults. Subjects and Methods: Eleven normal-hearing adults participated. The ABR test was repeated twice in the same clinical session and conducted again in another session. The ABR was acquired using both the click and LS CE-Chirp® stimuli at 4 presentation levels (80, 60, 40, and 20 dBnHL). Only the right ear was tested using the ipsilateral electrode montage. The reliability of the ABR findings (amplitudes and latencies) to the click and LS CE-Chirp® stimuli within the same clinical session and between the two clinical sessions was calculated using an intra-class correlation coefficient analysis (ICC). Results: The results showed a significant correlation of the ABR findings (amplitude and latencies) to both stimuli within the same session and between the clinical sessions. The ICC values ranged from moderate to excellent. Conclusions: The ABR results from both the LS CE-Chirp® and click stimuli were consistent and reliable over the two clinical sessions suggesting that both stimuli can be used for neurological diagnoses with the same reliability.

치과위생사의 경증 장애인 환자 진료 고려사항에 대한 지식 측정 도구의 타당도와 신뢰도 검증 (Testing the validity and reliability of an assessment tool for dental hygienists' consideration of patients with mild disabilities)

  • 김예지;노희진;문소정;한선영
    • 한국치위생학회지
    • /
    • 제23권1호
    • /
    • pp.55-62
    • /
    • 2023
  • Objectives: The purpose of this study was to test the reliability and validity of an assessment tool for dental hygienists' consideration of patients with mild disabilities. Methods: Thirty-seven preliminary questions were compiled through literature review, and thirty-two questions were selected through content validity testing by eight experts. Two hundred and three dental hygienists completed the assessment tool as an online survey. The construct validity, internal consistency, and test-retest reliability of the tool were investigated using the SPSS 26.0 program. The construct validity was assessed using exploratory factor analysis. The internal consistency was assessed using Cronbach's alpha. The intraclass correlation coefficient (ICC) value with 95% confidence intervals was calculated for test-retest reliability. Results: Ten items and four factors were selected through exploratory factor analysis. The internal consistency reliability of the tool was found to be Cronbach's alpha=0.658, and test-retest reliability was found to be ICC=0.812. Conclusions: An assessment tool of care for patients with mild disabilities by dental hygienists is a reliable and valid tool suitable for the job characteristics of dental hygienists. It can be used in clinical practice and research.

Reliability and Concurrent Validity of Korean Version of the Trunk Control Measurement Scale (K-TCMS) for Children with Cerebral Palsy

  • Ko, Jooyeon;Jung, Jeewoon
    • The Journal of Korean Physical Therapy
    • /
    • 제29권1호
    • /
    • pp.16-26
    • /
    • 2017
  • Purpose: This study was conducted to develop a Korean version of the trunk control measurement scale (TCMS) and examine the reliability and concurrent validity of the K-TCMS in children with cerebral palsy. Methods: Subjects for the study were 23 children with cerebral palsy (CP)(mean age: 84.70 months) recruited from one CP clinic. For the interrater and test-retest reliabilities, four raters (A, B, C, D) measured the K-TCMS two times using video clips with an interval of two weeks. For the concurrent validity, the Korean version of the gross motor function measure (K-GMFM) was chosen. Inter-rater reliability and test-retest reliability of the three K-TCMS subscale (static sitting balance, dynamic sitting balance and dynamic reaching) scores and the total scores were investigated using the intra-correlation coefficient ($ICC_{3,1}$). Spearman's correlation coefficient (r) was calculated to investigate the concurrent validity. Results: The inter-rater reliability of the K-TCMS subscales and total scores were all high ($ICC_{3,1}=0.968-0.992$). For the test-retest reliability, $ICC_{3,1}=0.827-0.962$. The concurrent validity between the K-TCMS's total and three subscale scores and K-GMFM's total score were r=0.600-0.667. Conclusion: The results suggest that the K-TCMS can be used in clinical and research settings as a standardized tool for CP children. The K-TCMS might be also useful for selecting treatment goals and planning interventions for children with cerebral palsy.

Reliability of the Korean Version of Tampa Scale for Kinesiophobia for Temporomandibular Disorders

  • Park, In Hee;Jang, Ji Hee;Chung, Jin Woo
    • Journal of Oral Medicine and Pain
    • /
    • 제43권2호
    • /
    • pp.34-40
    • /
    • 2018
  • Purpose: The aim of this study was to translate the original English version of tampa scale for kinesiophobia for temporomandibular disorders (TSK-TMDs) for cultural equivalency into Korean language and to evaluate the reliability of the Korean version of the TSK-TMD among symptom free subjects. Methods: The original version of TSK-TMD was translated and cross-culturally adapted following international guidelines. A total 90 subjects (50 women, 40 men) were participated to fill out the questionnaire. The internal consistency and test-retest reliability with a one- or two-week time interval were evaluated. Results: The internal consistency of TSK-TMD of the original and the modified 12-item TSK-TMD were 0.866, and 0.858, respectively using the Cronbach's alpha coefficient. And the internal consistency of activity avoidance (AA) and somatic focus (SF) subscale were 0.838 and 0.807 assessed with Cronbach's alpha indicating excellent reliability. Test-retest reliability of the original TSK-TMD measured by the intra-class correlation coefficient (ICC) was 0.764, and coefficients value of the 12-question TSK-TMD was 0.752. Test-retest reliability of AA subscale was 0.722 and SF subscale was 0.677 measured by ICC. Conclusions: The Korean version of the TSK-TMD questionnaire was found to be a reliable instrument and successfully translated to Korean language. There are no significant differences between overall and modified version of TSK-TMD. It can be used as a valuable instrument for the analyses of the psychosocial aspects of the TMD patients in Korea.

화학요법을 받는 급성백혈병 환자 자가보고형 구강점막염 사정도구의 신뢰도와 타당도 분석 (Reliability and Validity of Patient Self-reported Daily Questionnaire on Oral Mucositis in Acute Leukemic Patients under Chemotherapy)

  • 최소은;김희승
    • Journal of Korean Biological Nursing Science
    • /
    • 제12권3호
    • /
    • pp.148-156
    • /
    • 2010
  • Purpose: Oral mucositis (OM) is a serious consequence of chemotherapy that cancer patients must undergo. The objectives of this study were to find out reliability and validity of patients self-reported daily questionnaires on OM, and the impact OM makes on daily functions. Method: To test the reliability of oral mucositis daily questionnaire (OMDQ), internal consistency of the instrument (Cronbach's ${\alpha}$ and correlation between items) and test-retest reliability were analyzed. Criterion validity and discriminative validity were evaluated using WHO, oral assessment guide, and Nicolatou assessment tool. Forty-eight acute leukemic patients under chemotherapy were enrolled in this study. Result: The Cronbach's ${\alpha}$ coefficient indicated sufficient internal consistency. Correlations of Mouth and throat soreness (MTS) and MTSActivity Limitations (MTS-AL) were statistically significant. MTS and MTS-AL scores on consecutive days were highly correlated (days13,14=.84-.96; test-retest reliability). OMDQ scale had high criterion validity and discriminative validity. Patients with more severe WHO OM grades had higher MTS mean scores. Conclusion: Oral mucositis in acute leukemic patients under going chemotherapy can be easily quantified by patient self-administered OMDQ with reliability and validity.

한국어판 감성지능 측정도구의 신뢰도와 타당도 검증 (The Reliability and Validity of Korean Version of Wong and Law Emotional Intelligence Scale (K-WLEIS))

  • 정하림;최희정;박명숙
    • 대한간호학회지
    • /
    • 제50권4호
    • /
    • pp.611-620
    • /
    • 2020
  • Purpose: The aim of this study was to evaluate the reliability and validity of the Korean version of the Wong and Law Emotional Intelligence Scale (K-WLEIS). Methods: Data were collected from 360 nursing students using a self reported questionnaire. Exploratory and confirmatory factor analysis were used to test construct validity. Convergence validity was identified by correlation with communication competency. Item convergent and discriminant validity were also analyzed. Reliability was evaluated internal consistency and test-retest reliability. Results: The results of exploratory factor analysis showed that the eigen values ranged from 1.34 to 5.86 and 73.2% of the total explained variance. Confirmatory factor analysis showed adequate model fit indices (χ2/df 1.89, RMSEA .07, GFI .89, CFI .95, and TLI .93) and standardized factor loadings (.48 to .87). The average extracted variances (.71 to .79) and composite reliability (.80 to .87) validated convergence and discriminant validity of the items. Test-retest reliability of intra-class correlation coefficient was .90 and the Cronbach's alpha coefficient was .88. Conclusion: The K-WLEIS is an appropriate scale for measuring the emotional intelligence of Korean nursing students. Therefore, it is expected that the K-WLEIS will be used for nursing education programs to improve nursing students' emotional intelligence.

관성측정장치를 이용한 요추 가동범위 측정방법의 반복성 및 검사자 내 검사-재검사 신뢰도 연구 (Test-retest Reliability and Intratest Repeatability of Measuring Lumbar Range of Motion Using Inertial Measurement Unit)

  • 안지훈;김현호;윤우석;이순호;신유빈;김상민;박영재;박영배
    • Journal of Acupuncture Research
    • /
    • 제31권1호
    • /
    • pp.61-73
    • /
    • 2014
  • Objectives : The purpose of this study is to estimate the test-retest reliability and the intratest repeatability in measuring the lumbar range of motion of healthy volunteers with wireless microelectromechanical system inertial measurement unit(MEMS-IMU) system and to discuss the feasibility of this system in the clinical setting to evaluate the lumbar spine movement. Methods : 19 healthy male volunteers were participated, who got under 21 points at oswestry disability index(ODI) were adopted. Their lumbar motion were measured with IMU twice in consecutive an hour for the test-retest reliability study. Intratest repeatability was calculated in the two tests separately. The calculated intraclass correlation coefficients(ICC) were discussed and compared with the those of the previous studies. Results : Lumbar range of motion of flexion $41.45^{\circ}$, extension $16.34^{\circ}$, right lateral bending $16.41^{\circ}$ left lateral bending $13.63^{\circ}$ right rotation $-2.47^{\circ}$, left rotation $-0.61^{\circ}$. ICCs were 0.96~1.00(intratest repeatability) and 0.61~0.92(test-retest reliability). Conclusion : This study shows that MEMS-IMU system demonstrates a high test-retest reliability and intratest repeatability by calculated intraclass correlation coefficients. The results of this study represents that wireless inertial sensor measurement system has portable and economical efficiency. By MEMS-IMU system, we can measures lumbar range of motion and analyze lumbar motion effectively.

하지 강직 평가에 있어 NK테이블을 이용한 진자검사의 유용성 (Availability of the Pendulum Test Using NK Table for Spasticity Measurement of Low Extremity)

  • 김용욱;원종혁;김태호
    • 대한물리의학회지
    • /
    • 제8권2호
    • /
    • pp.209-217
    • /
    • 2013
  • PURPOSE: The purpose of this study was to investigate the clinical availability of the pendulum test (through reliability and validity) using a NK table attached electrogoniometer for spasticity measurement in patients with brain lesions. METHODS: Thirty-one stroke and traumatic brain injury subjects participated in the study. Intraclass correlation coefficient (ICC) was used to verify the test-retest reliability of spasticity measures of the pendulum test. Pearson's product correlation coefficient was used to examine the validity of the pendulum test through the amplitude of the deep tendon reflex (DTR) test known for objective and quantitative measure of spasticity. RESULTS: In these results, the test-retest reliability was showed significantly high correlation between pendulum tests (ICCs=.95~.97, p<.01). There were significant negative correlations between the amplitude of the DTR test and all measures of spasticity of the pendulum test(r=-.77~-.85, p<.01). CONCLUSION: Thus, it is possible to use the pendulum test using a NK table as an objective measure of spasticity, rather than other expensive equipment, which is more complicated to use. Further studies are needed to explore the therapeutic effects of spasticity using a newly designed pendulum test equipment in this study.

아동감각처리척도(Sensory Processing Scale for Children; SPS-C)의 검사-재검사 신뢰도와 검사자간 신뢰도 연구 (A Study of Test-Retest Reliability and Interrater Reliability of the Sensory Processing Scale for Children (SPS-C))

  • 김경미;김가연;이승진
    • 대한감각통합치료학회지
    • /
    • 제20권2호
    • /
    • pp.11-21
    • /
    • 2022
  • 목적 : 본 연구의 목적은 국내에서 개발된 아동감각처리척도(Sensory Processing Scale-Children; SPS-C)의 안정성 확립을 위해 감각처리에 어려움을 가진 만 3~5세 아동의 보호자를 대상으로 검사-재검사 신뢰도와 검사자간 신뢰도를 검증하는 것이다. 연구방법 : 본 연구의 대상자는 감각처리에 어려움을 가진 3~5세 아동 70명이었다. 검사-재검사 신뢰도 검증은 감각처리에 어려움을 가진 아동의 주 양육자 20명이 대상이었다. 초기평가 후 7~14일 내로 재평가를 실시하였고, 두 시점 간 관련성은 피어슨 상관계수를, 일치도는 급내상관계수를 사용하였다. 검사자 간 신뢰도 검증은 감각처리에 어려움을 가진 아동의 주 양육자, 부 양육자 각각 18명을 대상으로 하였다. 두 검사자 간의 일치도 확인은 급내상관계수를 사용하였다. 결과 : 검사-재검사 신뢰도는 피어슨 상관계수 r=.914, 급내상관계수 ICC=.939로 높은 수준의 관련성과 일치도를 나타냈다. 검사자간 신뢰도는 급내상관계수 ICC=.727로 좋은 일치도를 나타냈으나 촉각 영역(ICC=.455)과 고유감각 영역(ICC=.439)은 통계적으로 유의하지 않았지만, 보통의 일치도를 보였다. 결론 : 본 연구를 통해 아동감각처리척도(SPS-C)는 검사-재검사 신뢰도와 검사자간 신뢰도가 검증되어 안정성 있는 평가도구임을 확인하였으며, 추후 임상적 사용을 위한 표준화 연구에 도움을 제공할 수 있을 것이다.