• Title/Summary/Keyword: TEST-1

Search Result 59,887, Processing Time 0.071 seconds

Genotoxicity Test of Bojungikkeehapdaechilki-tang water extract (보중익기합대칠기탕(補中益氣合大七氣湯) 추출물의 유전독성 평가)

  • Hwang, Hui-Jeung;Byun, Joon-Seok;Heo, Jin-Il
    • Herbal Formula Science
    • /
    • v.14 no.1
    • /
    • pp.141-167
    • /
    • 2006
  • The genotoxicity of water extract of Bojungikkeehapdaechilki-tang was tested by In Vitro Chromosome Aberration Test. Bacterial Reverse Mutation Assay and Micronucleus test according to OECD Guidelines and KFDA Guidelines. The obtained results were as follows : 1. Chromosome Aberration Test: In Vitro Chromosome Aberration Test of Bojungikkeehapdaechilki-tang extracts was carried out using cultured Chinese hamster lung cells in the presence and absence of metabolic activation system(S-9 mix). No significant changes in the number of aberrant metaphases having structural and number of aberrations were detected in Bojungikkeehapdaechilki-tang extracts treated groups. 2. Bacterial Reveres Mutation Assay: Bojungikkeehapdaechilki-tang extracts was evaluated for its potential to induce reverse mutation in the histidine auxotroph strains of Salmonella typhimurium such as TA100, TA1535, TA98 and TAl537 and the tryptophan auxotroph strain of Escherichia coli WP2 uvrA. No significant changes in the number of revertant colonies compared to its negative control were detected in Bojungikkeehapdaechilki-tang extracts treated groups against all 5 strains. 3. Micronucleus test: Micronucleus test of Bojungikkeehapdaechilki-tang extracts were performed using specific pathogen free 7-week old male ICR mouse. No significant changes in the number of micronucleated polychromatic erythrocytes among 2000 polychromatic erythrocytes compared to negative control were detected in all Bojungikkeehapdaechilki-tang extracts treated groups. In summarized above-mentioned results, it is concluded that Bojungikkeehapdaechilki-tang extracts have not genotoxicity against In Vitro Chromosome Aberration Test, Bacterial Reverse Mutation Assay and Micronucleus test.

  • PDF

Ground Test and Evaluation of a Flight Control Systemfor Unmanned Aerial Vehicles

  • Suk, Jin-Young
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.5 no.1
    • /
    • pp.57-63
    • /
    • 2004
  • UAV(Unmanned Aerial Vehicle) has become one of the most popularmilitary/commercial aerial robots in the new millennium. In spite of all theadvantages that UAVs inherently have, it is not an easv job to develop a UAVbecause it requires very systematic and complete approaches in full developmentenvelop. The ground test and evaluation phase has the utmost importance in thesense that a well-developed system can be best verified on the ground. In addition,many of the aircraft crashes in the flight tests were resulted from the incompletedevelopment procedure. In this research, a verification procedure of the wholeairbome integrated system was conducted including the flight management system.An airbome flight control computer(FCC) senses the extemal environment from thepehpheral devices and sends the control signal to the actuating system using theassigned control logic and flight test strategy. A ground test station controls themission during the test while the downlink data are transferred from the flightmanagement computer using the serial communication interface. The pilot controlbox also applies additional manual actuating commands. The whole system wastested/verified on the wind-tunnel system, which gave a good pitch controlperformance with a preUspecified flight test procedure. The ground test systemguarantees the performance of fundamental functions of airbome electronic systemfor the future flight tests.

The Interaction Effects on Test Anxiety of Elementary School Students by Academic Self-Efficacy and Test Anxiety Coping Styles (초등학생의 시험불안에 대한 학업적 자기효능감과 시험불안 대처방식의 상호작용효과)

  • Yang, Yeon-Suk;Kwon, Jung-Im
    • Journal of the Korean Home Economics Association
    • /
    • v.50 no.1
    • /
    • pp.79-88
    • /
    • 2012
  • The purpose of this study was to examine the interaction effects of children's academic self-efficacy and to test their anxiety coping style in terms of their test anxiety. We conducted a questionnaire survey with 193 sixth-graders in an elementary school. The results of this study are summarized as follows. First, the children were more worried about emotionality to test anxiety, and used problem-focused coping significantly more frequently than emotion-focused coping. In addition, female children demonstrated more emotionality and worry about test anxiety and used emotion-focused coping for test anxiety more frequently. Second, emotionality was higher when emotion-focused coping was used. In the case where the level of problem-focused coping was high, emotionality was higher when academic self-efficacy was high. Children's worry was lower when the level of problem-focused coping was high and when the level of emotion-focused coping was low. In female children, however, worry increased when the level of problem-focused coping was low and the level of emotion-focused coping was high.

The mechanical property investigation according to the monomer weight ratio of the dental acrylic denture base resin (치과용 의치상 아크릴릭 레진 단량체 중량비에 따른 기계적 성질)

  • Lee, HeeKyung;Sun, GumJoo
    • Journal of Technologic Dentistry
    • /
    • v.35 no.4
    • /
    • pp.287-293
    • /
    • 2013
  • Purpose: This study is to provide basic data of the dental acrylic denture base resin in the mechanical property difference investigation according to the monomer composition weight ratio of the acrylic denture base resin. Methods: The monomer composition of the acrylic denture base resin and weight ratio makes the different specimen. It measured the mechanical property with the specimens through Hardness Test, Tensile Test, Flexural Test, Flexural Modulus, FT-IR Test. Results: The control group Vertex was 18.4 Hv and the experimental group MED was 14.46~19.07Hv in the hardness test. Vertex was 364N, MED-3 was lowest in the tensile strength test and the Head of a family cursor declination was big. The result declination of the experimental specimens showed. Vertex and MED-2 was the highestest in the flexural test and after coming MED-6, MED-5, MED-1, MED-3, MED-4. Vertex and MED-2, as to a spectrum for $500{\sim}1800cm^{-1}$ peak can show the excellent degree of polymerization in the FT-IR Test. Conclusion: The ideal weight ratio of the monomer of the acrylic denture base resin of which the mechanical property is the highestest was MMA 100g, EDGMA 5g, DMA 0.2g, of MED-2.

Determination of Explosive Weight for Cable Cutter through Impact Test (Impact Test를 통한 케이블커터의 화약량 산정)

  • Choi, Chang-Sun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.4
    • /
    • pp.16-22
    • /
    • 2012
  • We performed impact test to estimate necessary explosive charge weight for cutting the cable whose diameter is 22 mm. The impact test results were analyzed by Probit method. The cutting energy was calculated 37.7 J with 99.99% probability at 99% reliability compared to the average energy of 24.9 J. The cable was cut 3 times without failure with 150 mg of Zirconium Potassium Perchlorate (ZPP), which was considered to generate 24.5 J of mechanical energy with assumption that only 10% of explosive energy converts to mechanical energy. The calculated energy from measured pressure with 150 mg ZPP was 26.1 J, which is almost same with both impact test result and expected mechanical energy. We can argue that the cable can be cut with 99.99% probability at 99% reliability by 230 mg of ZPP.

Measurement Uncertainty Assessment of Altitude Performance Test for a Turboshaft Engine (터보샤프트 엔진 고공성능시험의 측정 불확도 평가)

  • Yang, In-Young;Lee, Bo-Hwa
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.4
    • /
    • pp.59-64
    • /
    • 2010
  • Measurement uncertainty assessment was performed for altitude performance test for a turboshaft engine. Mathematical models of measurement were suggested for major performance parameters such as shaft horse power, fuel flow, specific fuel consumption, and airflow. The procedure was compared with the test of turbojet or turbofan engines. Uncertainty involved with the test condition measurement was assessed. Influence of the test condition measurement uncertainty on the corrected performance data was discussed. Uncertainty assessment result was provided for a example test case using a real altitude test facility. For major performance parameters, measurement uncertainties were assessed as 0.65~1.09% including the test condition measurement uncertainty, 0.36~0.94% not including it.

The effect of augmented feedback type on motor learning for hemiplegic adults (보강적 피드백의 형태가 편마비 성인의 운동학습에 미치는 영향)

  • Cho, Hyuk-Shin;Jeong, Wang-Mo
    • PNF and Movement
    • /
    • v.9 no.1
    • /
    • pp.11-19
    • /
    • 2011
  • The purpose of this study was to investigate whether it makes difference to use of the Augmented Feedback Type(Verbal Feedback, VTR Feedback and Verbal & VTR Feedback) to hemiplegic adults on learning of motor skill. For the purpose 15 hemiplegic adults who are received rehabilitation program at H hospital in Hong-Sung, Choong-Nam Province. Subjects were classified into three groups by random assignment; the Verbal Feedback group, the VTR Feedback group and Verbal & VTR Feedback group. Each groups received 5 subjects from hemiplegic adults. Subjects were tested by Timed Up and Go test for 9 weeks. And to find out the improvement measured by Pre-Test, Acquisition Test and Retention Test. To find out the improvement of each group's measures took average and standard deviation. To probate the significance of difference between the improvement conducted the one-way ANOVA and to probate the significance of difference of Acquisition Test and Retention test conducted paired t-test. The results of this study were as follows; First, All of Augmented Feedback Types had a positive effect on hemiplegic adults to learning of motor skill. Second, The Verbal Feedback group and the VTR Feedback group had no significantly difference at Acquisition Test, But They had the most improvement at Retention Test. Third, In hemiplegic adults, the Verbal & VTR Feedback group had the highest Retention Effect.

A Study on the Determination of Construction Depth of Vertical Drain by Cone Resistance (콘 관입저항치를 이용한 수직배수재 타설심도 결정에 관한 연구)

  • Jang, Seo-Yong;Kim, Jong-Ryeol;Shin, Yun-Sup;Ma, Bong-Duk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.5
    • /
    • pp.163-170
    • /
    • 2006
  • Recently, piezocone penetration test is frequently used in order to estimate the characteristics of soft ground with standard penetration test, generally used in the past. In this study, the correlation of standard penetration test, piezocone penetration test and driving resistance of vertical drain is analyzed in order to increase the confidence for determination of soft ground depth. As the results of each zone, the relation between standard penetration test and piezocone penetration test shows qc=(1.09~1.63)N at the soft ground, determined by 5/30 N value which is decided for soft ground criteria. And qc=(1.21~1.98)N was shown at the point of compressible layer, evaluated by the preconsolidation pressure. And driving resistance of vertical drain is $65{\sim}70kgf/cm^2$ which is equal to $10kgf/cm^2$ of cone penetration resistance.

Evaluation of Skin Friction Using Tensile Load Testing of CPR Piles (CPR 말뚝의 인발재하시험을 통한 주면마찰력 평가)

  • Ko, Chin-Surk;Kim, Jung-Han;Noh, Jeongdu;Kang, Seong-Seung
    • The Journal of Engineering Geology
    • /
    • v.30 no.1
    • /
    • pp.59-69
    • /
    • 2020
  • Pull-out load tests were performed on a CPR (Compaction grouting compound Pile with Reinforce) test pile, with skin friction being evaluated by the yield load and allowable bearing capacity after analyzing load-displacement curves and load-settlement curves. Results of the CPR test piles analyzed from the load-displacement curves show that the yield load and allowable bearing capacity of the large-diameter CPR test pile were about 1.4 times larger than that of the small-diameter pile. Results of the load-settlement curves reveal that the allowable bearing capacity of the CPR test pile with diameter of D500 was 1.2~2.1 times greater than that of the pile with diameter of D400. However, the allowable bearing capacity calculated using Fuller's analysis differed substantially from that determined using the P (Pull-out load) - S (Settlement) and log P - log S curves. Therefore, calculation of the allowable bearing capacity using Fuller's analysis is shown to be inappropriate.

Evaluation of Field Permeability and Material Characteristics of Permeable Block for Roadway Pavement (차도포장용 투수블록의 재료특성 및 투수성능 평가)

  • Park, Daegeun;Jung, Wonkyong;Jeong, Doowon;Baek, Jongeun;Lee, Jinwook
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.2
    • /
    • pp.110-116
    • /
    • 2016
  • The rapid expansion of buildings and paved roads increases the risk of flood disaster in an urban area. One of the solutions can be the use of permeable pavements. This study evaluated the permeability of permeable blocks used for the roadway pavement. Joint fillers and mat sands of the investigated blocks met the corresponding standards. The flexural strength of the blocks was 5.29 MPa to meet these standards. Based on interior permeability test results after pollution, the four products evaluated were categorized into the following three levels: One for the $1^{st}$ level, one for the $2^{nd}$ level and two for the $3^{rd}$ level. From the field permeability test and pervious concrete infiltration test results nine months after their construction, all the products except one passed the quality standards of 0.1 mm/s.