• Title/Summary/Keyword: TEST-1

Search Result 59,887, Processing Time 0.076 seconds

A Study on the Test Device for Improving Test Speed and Repeat Precision of Semiconductor Test Socket (반도체 테스트 소켓의 검사속도 및 반복 정밀도 개선형 검사장치에 관한 연구)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.327-332
    • /
    • 2021
  • At the package level, semiconductor reliability inspections involves mounting a semiconductor chip package on a test socket. The form of the test socket is basically determined by the form of the chip package. It also acts as a medium to connect with test equipment through mechanical contact of the leads and socket leads in the chip package, and it minimizes signal loss in a signal transmission process so that an inspection signal can be delivered well to the semiconductor. In this study, a technique was applied to examine the interdependence of adjacent electrical transfer routes and the structure of adjacent electrical transfer paths. The goal was to enable short-circuit testing of fewer than 100 silicon test sockets through a single interface for life tests and precision measurements. The test results of the developed device show a test precision of 99% or more and a simultaneous test speed characteristic of 0.66 sec or less.

Research on the on-site Seat Test Technology for the nuclear safety related valves (원전용 안전등급 밸브의 현장 폐쇄기밀시험 기술에 대한 연구)

  • Jung Hwan Seok;Kim Tae Sung
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.1
    • /
    • pp.8-17
    • /
    • 2021
  • The seat leakage test is required after the maintenance work on the valve seat. Either the test has been performed outside of the plant after cutting the valve from the pipe system or the simplified test has been performed so far. It was unable to perform the test at the plant site because it is hard to make a steady pressure on the valve inlet when it is installed in the pipe. This research aims to perform the leakage test in the nuclear power plant while it is installed in the pipe system. The mock-up test is performed by pressurizing the leak-off pipe on the valve body. The result is compared with traditional test result by pressurizing the valve inlet. Furthermore the chamber mock-up tests are performed under various conditions. The leak rate by the developed test using the leak-off pipe is found to be similar but greater than the leak rate by the existing test method. It implies that the test using the leak-off pipe is more conservative than the existing test. The methodology and the equipment which this paper suggests that on-site seat test is possible and the application of the technology could reduce the time and cost for the valve maintenance work significantly.

Design and Implementation of the Automatic cable assembly test system that can test cable assembly effectively

  • Jang, Ki-Mang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.7
    • /
    • pp.1-10
    • /
    • 2018
  • In this paper, we propose the principles and design details of Automatic cable assembly test system and show its utility. Testing the cable assembly is required periodically or non-periodically in the system that the cable assembly performance is quite important like military equipment. There are several weaknesses when humans test the cable assembly manually. It not only takes much time but also could happen human error. To improve these disadvantages, I developed Automatic cable assembly test system. The system can be implemented by building switching control system that connect and disconnect the cable assembly and measuring devices. Through the result of the cable assembly test with this test system, we show this system makes test time short and improves of test reliability as compared with manual test.

Studies on Various Test Conditions and Application of Test Method for Lipoxygenase-l in Soybean (콩의 Lipoxygenase-1 신속 검정방법 확립)

  • 조준형;김영미;윤홍태;김용호;김용욱;김명애
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.42 no.6
    • /
    • pp.739-747
    • /
    • 1997
  • This study was performed to clarify various conditions on the test of lipoxygenase-l and to establish the application of new test method for varietal improvement of soybeans in order to decrease beany flavors. Potassium borate and Tris were used as buffer and O.1M potassium borate solution showed the best result for the lipoxygenase-l test. In the range of pH 8.5~9.0 of the buffer, 2mM linoleic acid as substrate was effective. For color development, 100$\mu$l of two solutions(KI and starch) were added to the half soybean seed, successively. The substrate solution included linoleic acid was stored safely for 10 days at 4$^{\circ}C$ in refrigerator and for 4 days at room temperature. The best result was as follows; the 1ml of substrate solution[0.1M potassium borate(pH 9.0), 0.1% Tween-20, 2mM linoleic acid] was added to the chipped half soybean seed in l.5ml plastic tube, waited for 15 minutes, and 100$\mu$l of color development solutions(5% saturated KI in 15% acetic acid, 1% starch) were added to the tube, successively. After 4 hours, the purple color was observed in the upper phase of the plastic tube in the presence of lipoxygenase-1 and milky color in absence of lipoxygenase-1. The purple color was stable from 4 to 24 hours. There was no interfering effect by lipoxygenase-2 and -3. The plastic tube should be placed in the tube stand without shaking during the lipoxygenase-l test.

  • PDF

Effects on Health Promotion Behavior of Health Instruction in Elementary School (초등학교 보건학습이 건강증진행위에 미치는 영향)

  • Hong, Hyun-Mi;Lee, Hyeo-Kun
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.1
    • /
    • pp.1-9
    • /
    • 2000
  • The purpose of this study were to assess the effect on health promotion behavior of health instruction in elementary school and to provide a basis of school health education. Subjects of this study were random sampled 80 students for control group in elementary 6th grade students. the treatment group systematically studied five sphere instruction: individual hygiene, disease prevention, first-aid & safety, oral health, health & nutrition in two hours a week, from April 20, till July 10. Each group was pre-tested and post-tested by health behavior promotion questionnaire. The conclusions as follows; 1. Compare analysis of control group and treatment group in the pre-test according to health condition of children were no significant difference physical health condition, health anxiety, disease-absent(P>.05). 2. Health promotion behaviors in the post-test according to concern quotient significantly correlated with individual hygiene(r=.249, P<.05), disease prevention(r=.477, P<.01), oral health(r=.228, P<.05), health & nutrition(r=.323, P<.01) in the treatment group, on the contrary the disease prevention, first-aid & safety, oral health, health & nutrition(P>.05). 3. The difference of health promotion behavior within & between group were as follow; 1) The difference of individual health hygiene with in the treatment group was significant in pre-post test, the comparison of the two groups was significant difference in post-test(treatment group: $3.965{\pm}.568$, control group: $3.645{\pm}.573$). 2) The difference of disease prevention with in the treatment group was significant in pre-post test, the comparison of the two groups was significant difference in post-test(t group : $3.475{\pm}.619$, c group: $3.964{\pm}.600$). 3) The difference of first-aid & safety with in the treatment group was significant in pre-post test, the comparison of the two groups was significant difference in post-test(t group : $3.700{\pm}.466$, c group: $4.140{\pm}.545$). 4) The difference of oral health with in the treatment group was significant in pre-post test, the comparison of the two groups was significant difference in post-test(t group: $3.163{\pm}.665$, c group: $3.753{\pm}.544$). 5) The difference of health & nutrition with in the treatment group was significant in pre-post test, the comparison of the two groups was significant difference in post-test(t group : $3.255{\pm}.515$, c group: $3.698{\pm}.558$).

  • PDF

A Comparison of the Kibrick Macro-Agglutination Test and the Isojima Micro-Immobilization Test for Antisperm Antibody in Male Sera (항정자항체 검출에 있어서 gelatin 정자응집검사법 및 정자부동화검사법의 비교관찰)

  • Soh, Byoung-Uck;Kim, Sae-Chul
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.12 no.1
    • /
    • pp.41-46
    • /
    • 1985
  • Various immunoserologic and cellular immunity techniques have been used to explore the presence of antisperm antibodies in the serum and seminal plasma of male patients and in the blood and genital fluid of infertile women. Several recent comparative investigations using various assays to detect and quantitate levels of antibody to human spermatozoa have produced widely varying results. So the first WHO workshop on iso- and autonatibodies to human spermatozoa in 1974 tried to establish some unification in the techniques used. The purpose of this study is to compare the results of two methods-the Kibrick macro-agglutination test and the Isojima micro-immobilization test-using the same test materials based on recommandation from WHO workshop. The results are as follows: 1. Twenty normal controls showed negative reactions in all the 2 tests. Out of 25 patients, the positive sera were noted in 15 (60%) on the Kibrick test and 13 (51%) on the Isojima test. 2. Twelve (48%) out of 25 patients showed positive reactions in the two tests, and 16 (64%) out of 25 patients showed positive reaction in one or more tests. 3. The titers of the antisperm antibodies on the Kibrick test was higher than that on the Isojima test. Therefore, it seems to be possible to increase the chances of detection of the antisperm antibodies, if two tests are imployed.

  • PDF

The Reliability Evaluation of TBN Valve Testing Extension in NPP (원자력발전소 터빈밸브 시험주기 연장시 신뢰도평가)

  • Lim, Hyuk-Soon;Lee, Eun-Chan;Lee, Keun-Sung;Hwang, Seok-Won;Seong, Ki-Yeoul
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3221-3223
    • /
    • 2007
  • Recently, nuclear power plant companies have been extending the turbine valve test interval to reduce the potential of the reactor trip accompanied with a turbine valve test and to improve the NPP's economy through the reduction of unexpected plant trip or decreased operation. In these regards, the extension of the test interval for turbine valves was reviewed in detail. The effect on the destructive overspeed probability due to the test interval change of turbine valves is evaluated by Fault Tree Analysis(FTA) method. Even though the test interval of turbine valves is changed from 1 month to 3 months, the analysis result shows that the reliability of turbine over speed protection system meets acceptance criteria of 1.0E-4/yr. This result will be used as the technical basis on the extension of the test interval for turbine valves. In this paper, the propriety of the turbine valve test interval extension is explained through the review on the turbine valve test interval status of turbine overspeed protection system, the analysis on the annual turbine missile frequency and the probability evaluation of the destructive overspeed due to the test interval extension.

  • PDF

A Study on the Determination of Depth of Soft Ground by Cone Resistance (피조콘 관입저항치($q_c$)를 이용한 연약지반 심도결정에 관한 연구)

  • 신윤섭;김민철;김연정;김영웅
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.701-708
    • /
    • 2003
  • Recently, piezocone penetration test is frequently conformed in order to estimate the characteristics of soft ground with standard penetration test, generally used in the past. The soil characteristics, such as cone penetration resistance, friction resistence and excessive pore water pressure, can be evaluated continuously through the piezocone penetration test. In Incheon International Airport 2nd phase site preparation, standard penetration test and piezocone penetration test were used in order to increase the confidence for determination of soft ground depth. And the compressible layer was determined by the comparison between the preconsolidation pressure and the designed increase pressure. As the results, the relation between standard penetration test and piezocone penetration test shows q$_{c}$=(1.09~l.63)N at the soft ground, determined by 5/30 N value. And q$_{c}$=(1.21~l.98)N was shown at the point of compressible layer, evaluated by the preconsolidation pressure. These results were applied to determination for the depth of soft ground and to design the improvement for the soft clay.lay.

  • PDF

A goodness - of - fit test for the exponential distribution with unknown parameters (모수가 미지인 상황에서의 지수분포성 적합도 검정방법)

  • 김부용
    • The Korean Journal of Applied Statistics
    • /
    • v.4 no.2
    • /
    • pp.157-170
    • /
    • 1991
  • This article is concerned with the goodness - of - fit test for exponentiality when both the scale and location parameters are unknown. A test procedure based on the $L_1$-norm of discrepancy between the cumulative distribution function and the empirical distribution function is proposed, and the critical values of the test statistic are obtained by Monte Carlo simulations. Also the null distributions of the proposed test statistic are presented for small sample sizes. The power of tests under certain alternative distributions is investigated to compare the proposed test statistic with the well-known EDF test statistics. Our Monte Carlo power studies reveal that the proposed test statistic has good power properties, for moderate-to-large sample sizes, in comparison to other statistics although it is a conservative test.

  • PDF

A Study on Test for New Better than Used of an unknown specified age ($NBU-t_0$ Class에 대한 검정법 연구)

  • 김환중
    • Journal of Korean Society for Quality Management
    • /
    • v.29 no.2
    • /
    • pp.37-45
    • /
    • 2001
  • A survival variable is a non-negative random variable X with distribution function F(t) satisfying F(0) : 0 and a survival function F(t): 1-F(t). This variable is said to be New Better than Used of specified age t$_{0}$ if F(x+ t$_{0}$)$\leq$F(x).F(t$_{0}$) for all x$\geq$0 and a fixed t$_{0}$. We propose the test for H$_{0}$ : F(x+t$_{0}$)=F(x).F(t$_{0}$) for all x$\geq$0 against H$_1$: F(x+t$_{0}$) $\leq$ F(x).F(t$_{0}$) for all x$\geq$0 when the specified age to is unknown but can be estimated from the data when t$_{0}$$_{p}$, the pth percentile of F. This test statistic, which is based on the normalized spacings between the ordered observations, is readily applied in the case of small sample. Also, our test is more simple than Ahmad's test (1998). Finally, the performance of our test is presented.our test is presented.

  • PDF