• Title/Summary/Keyword: TEST-1

Search Result 59,887, Processing Time 0.067 seconds

A study on the clinical usefulness, validity, and test-retest reliability of the Spirokit, a device that combines the pulmonary function test and respiratory muscle strength test

  • Kim, Byeong-Soo;Lee, Myung-Mo
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.2
    • /
    • pp.120-130
    • /
    • 2020
  • Objective: This study was conducted to identify the clinical usefulness, validity, and reliability of the Spirokit, a device that combines the pulmonary function test (PFT) and respiratory muscle strength (RMS) test. Design: Cross-sectional study. Methods: Forty young adults (male: 23, female: 17) participated in a PFT and a RMS test. The concurrent validity for pulmonary function was assessed by comparing data obtained from MicroQuark and the Spirokit and the agreements between the MicroRPM and the Spirokit for RMS were compared. The test-retest reliability of the Spirokit was determined by comparing data obtained from the first and second sessions. The test and retest were performed at the same time after one day for the PFT and RMS test. Validity was estimated using intraclass correlation coefficients (ICCs), and by calculating 95% limits of agreement (LoA). To estimate interrater reliability, ICCs were calculated. Results: The Spirokit showed a high agreement intra class coefficient (ICC [2, 1]): 0.978-0.999, 95% limits of agreements (95% LOA): -0.798 to 0.847 with MicroQuark. It also showed a high level of concordance ICC (2, 1): 0.992 to 0.993, 95% LOA: -9.313 to 11.169 with MicroRPM. The test-retest reliability of the Spirokit was analyzed using ICC (2, 1), and showed a high level of reliability (ICC [2,1]=0.960 to 0.998). Standard error of measurement % (SEM%) was 0.12% to 3.39%, and minimum detectable change% (MDC%) was 0.02% to 3.79%, indicating high level of reliability. Conclusions: The Spirokit is a device with high validity and reliability that can be used to simultaneously measure PFT and RMS tests.

Construction and Functional Tests of Fuel Assembly Mechanical Characterization Test Facility (핵연료집합체 기계적특성 시험시설 구축과 기능시험)

  • Lee, Kang-Hee;Kang, Heung-Seok;Yoon, Kyung-Ho;Yang, Jae-Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.11-16
    • /
    • 2016
  • Fuel assembly's mechanical characterization test facility (FAMeCT) in KAERI was constructed with upgraded functional features such as increased loading capacity, underwater vibration testing and severe earthquake simulation for extended fuel design guideline. This facility is designed and developed to provide out-pile fuel data for accident analysis model and fuel licensing. Functional tests of FAMeCT were performed to confirm functionality, structural integrity, and validity of newly-built fuel assembly mechanical test facility. Test program includes signal check of data acquisition system, load delivering capacity using real-sized fuel assemblies and a standard loading cylindrical rigid specimen. Fuel assembly's lateral bending test was carried out up to 30 mm of pull-out displacement. Limit case axial compression loading test up to 33 kN was performed to check structural integrity of UCPS (Upper Core Plate Simulator) support frame. Test results show that all test equipment and measurement system have acceptable range of alignment, signal to noise ratio, load carrying capacity limit without loss of integrity. This paper introduces newly constructed fuel assembly's mechanical test facility and summarizes results of functional test for the mechanical test equipment and data acquisition system.

A Case Study of Hot In-Place Recycling Asphalt Mixture in Korea (국내 현장가열재생아스팔트 시공 혼합물 시험평가)

  • Kwon, Sooahn;Yang, Sunglin;Lee, Jaejun;Hong, Jaecheong;Lim, Jaekyu
    • International Journal of Highway Engineering
    • /
    • v.15 no.1
    • /
    • pp.57-63
    • /
    • 2013
  • PURPOSES: This study is to investigate the Hot In-Place recycling asphalt mixture in Korea using field produced materials. METHODS: Hot In-Place reclaimed asphalt mixture was investigated to evaluate the mixture properties based on various test results such as Marshall Test, Indirect Tensile Test, TSR, and Wheel Tracking Test. These test values were compared with domestic standard specification. RESULTS: The result of the laboratory experiment indicates that the Hot In-Place Reclaimed(HIR) asphalt mixture produced at the field constrution site was satisfied all of the test criteria such as Indirect tensile test, Marshall and TSR test, and wheel tracking test. During the test, the research team found that current HIR system is required an extention of mixing time to improve quality and to reduce variation of sample to sample. Although the current HIR mixture was passed the test criteria, there is a potential capability to enhance the mixture properties as extend mixting time. CONCLUSIONS: Based on these laboratory test results, It would be concluded that domestic HIR mixture's properties were satisfied all standard specification related with evaluation of recycling asphalt mixtures. Based on this case study result, there is a chance to save construction cost and increase the usage of reclaimed asphalt concrete in the future.

Study on Effect of Crafts and Hand-writing on Bilateral Coordination (수공예활동과 글씨쓰기활동이 양손협응(Bilateral coordination)에 미치는 영향)

  • Choi, Hyae-Sook
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.4 no.2
    • /
    • pp.63-73
    • /
    • 2014
  • Objective : The purpose of this study was to identify the effect of crafts and handwriting on bilateral coordination during task performance. Methods : Randomly selected 30 college students without hand disability were invited for the study, and grouped 3(test group 1 for crafts, test group 2 for handwriting, and control group) with 10 students per group respectively. Then Jebsen-taylor hand function test, Purdue pegboard test, and Minnesota manual dexterity test were employed for evaluating changes before and after the intervention. Results : After training intervention of crafts and handwriting for two test groups, test groups showed better bilateral coordination significantly than the control group. Especially test group 1(crafts) showed a bigger difference at Jebsen-taylor hand function test, and likely test group 2(handwriting) did at Purdue pegboard test. Conclusion : It was found that crafts increase bilateral coordination, while handwriting increase hand dexterity during task performance. That is, crafts and handwriting affect tasks differently. Further studies applying various crafts and handwriting for many age groups will be helpful for identifying the better way of occupational intervention for individuals in lack of bilateral coordination.

  • PDF

Problem Analysis and Study of Solution Device in Relation with Middle School Mathematics Performance Assessment (중학교 수학과 수행평가의 문제점 분석 및 그 해결 방안 연구)

  • 박재용
    • Journal of the Korean School Mathematics Society
    • /
    • v.3 no.1
    • /
    • pp.149-163
    • /
    • 2000
  • The Ministry of Education have had us practice the performance test as a substitute proposal, however, all the more for the idealistic purport, our education front does not have such a sufficient condition as to practice the performance test for many classes and miscellaneous duties and over-populated class, and that practice has been enforced so abruptly without any drastic preparation and has caused much confusion from the beginning of that enforcement. Thus, these problematic concerns are remained as the tasks of the teachers to be solved by themselves in the front of education, and herein I came to do this research. The followings are the conclusions that I got as the results of the research (1) Performance test style should be applied in consideration of the students' achievement level and the gap of the teachers' recognition; descriptive test, portfolio assignment and formative test styles were proper for the students lacking basic study ability. (2) Descriptive test should have its beginning with the question items to which students can write the problem solving procedure logically rather than those to evaluate the creation ability and thinking ability: and putting down specifically the assessment standard could prevent students' confusion and scheme the impartiality of the assessment. (3) Portfolio assignment evaluation should be given with as interesting and suitable amounts as possible so that the students can do by themselves. (4) Utilizing the performance test table enabled easy management of documentary evidence. And it is needless to say that the success of the performance test should have preceding conditions like the teachers' understanding and their positive participation. Therefore, I'd like to give suggestions herein like the followings; (1) The performance test should not always be made into grades, and there is a need to develop the test gradually in the condition that the education surroundings permit by checking time, frequency, ratio and contents of the test while practicing the multiple choice writing test. (2) As long as the performance test has the aims of improving the studying and learning activities, any performance test only for the sake of making numerals with the thought that assessment is the disposal of the grades should be avoided, and the change of the lecturing styles and development of various assessing types and studying materials should be endeavored to confirm with the aims.

  • PDF

Deducing Coronary Artery Disease Anxiety through Musical Therapy and Providing Information (정보제공과 음악요법이 심혈관조영술 환자의 불안에 미치는 영향)

  • 강미숙;박경민;박청자
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.2
    • /
    • pp.380-390
    • /
    • 2000
  • This study was performed to evaluate the effectiveness of music therapy as one of the psychiatric nursing intervention tools, with addtional information in relieving anxiety during the procedure. Data were collected through nonequivalent pre-and post tests from July 1, 1998 to September 30 1998 in 90 patients (test group A: 28 patients, test group B: 27 patients, control group: 33 patients) who were hospitalized in DongSan Medical Center in order to have cardiac catheterization. The Subjects were informed by educational videos, which were modified according to the sensory information of the 10 study patients. They were based on the informative booklet by Kim keum-soon (1989). The procedural information was also modified according to the hospital`s customs. Provided the music for patients suitable to their tastes, and measured their blood pressure, heart rate, the degree of anxiety using the Spielberger`s measurement device of anxiety, and behavioral response of Finesilver`s. The statistical significance was analyzed using chi-square test and ANOVA. The results of this study were as follows : Hypothesis 1 : There are significant differences in the degree of anxiety among test group A, Test group A was provided only information, Test group B was provided information and the control group was provided neither. Hypothesis 2 : There are significant differences in systolic blood pressure among test group A, test group B, and control group.: non-significant. Hypothesis 3 : There are significant differences in diastolic blood pressure among test group A, test group B, and control group.: significant(F=1.31, p=.27, interaction; F=3.80, p=.00). Hypothesis 4 : There are significant differences in heart rate among test group A, test group B, and control group.: non-significant. Hypothesis 5 : There are significant differences in behavioral responses among test group A, test group B, and control group.: significant(F=10.05, p=.00). Further validation study is required with other subjects and other settings.

  • PDF

The Reliability and Validity of Figure-of-8 Walk Test in Patients with Stroke (뇌졸중 환자에서 Figure-of-8 walk test의 신뢰도와 타당도)

  • Kim, Yang-Ho;Lim, Jae-Heon
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 2012
  • Purpose : The purpose of this study was to establish intra-rater, inter-rater, test-retest reliability, and concurrent validity of figure-of-8 walk test in people with stroke. Methods : The subjects of this study were 17 patients who were diagnosed with a stroke. Subjects were tested twice by the same raters, with 1 day between tests. Subjects were assessed by two physical therapists. Test-retest reliability was calculated using intraclass correlation coefficients (ICC). The concurrent validity was demonstrated by spearman correlation of F8WT with 10m walking test (10MWT), timed up and go test (TUG), Berg balance scale (BBS), dynamic gait index (DGI) and four square step test (FSST). Results : Intra-rater, inter-rater, test- retest of F8WT time, showed high reliability. Intra-rater, inter-rater, test-retest of F8WT steps demonstrated high reliability. Intra-rater, inter-rater, test-retest of F8WT total smoothness score showed below moderate reliability. There was a significant positive correlation of F8WT time with 10MWT, TUG, FSST. There was a significant negative correlation of F8WT time with DGI, BBS. There was a significant positive correlation of F8WT steps with 10MWT, TUG, FSST. There was a significant negative correlation of F8WT steps with DGI. There was a significant positive correlation of F8WT test total smoothness score with BBS. Conclusion : The time, and number of steps in F8WT show high inter, intra-rater, test-retest reliability. The F8WT smoothness shows below moderate reliability. The F8WT shows high concurrent validity with other comparable balance, and walking tests. The F8WT is a valid and reliable measure for assessing walking function in patients with a stroke.

Concurrent Validity and Test-retest Reliability of the Core Stability Test Using Ultrasound Imaging and Electromyography Measurements

  • Yoo, Seungju;Lee, Nam-Gi;Park, Chanhee;You, Joshua (Sung) Hyun
    • Physical Therapy Korea
    • /
    • v.28 no.3
    • /
    • pp.186-193
    • /
    • 2021
  • Background: While the formal test has been used to provide a quantitative measurement of core stability, studies have reported inconsistent results regarding its test-retest and intraobserver reliabilities. Furthermore, the validity of the formal test has never been established. Objects: This study aimed to establish the concurrent validity and test-retest reliability of the formal test. Methods: Twenty-two young adults with and without core instability (23.1 ± 2.0 years) were recruited. Concurrent validity was determined by comparing the muscle thickness changes of the external oblique, internal oblique, and transverse abdominal muscle to changes in core stability pressure during the formal test using ultrasound (US) imaging and pressure biofeedback, respectively. For the test-retest reliability, muscle thickness and pressure changes were repeatedly measured approximately 24 hours apart. Electromyography (EMG) was used to monitor trunk muscle activity during the formal test. Results: The Pearson's correlation analysis showed an excellent correlation between transverse abdominal thickness and pressure biofeedback unit (PBU) pressure as well as internal oblique thickness and PBU pressure, ranging from r = 0.856-0.980, p < 0.05. The test-retest reliability was good, intraclass correlation coefficient (ICC1,2) = 0.876 for the core stability pressure measure and ICC1,2 = 0.939 to 0.989 for the abdominal muscle thickness measure. Conclusion: Our results provide clinical evidence that the formal test is valid and reliable, when concurrently incorporated into EMG and US measurements.

An ionic liquid incorporated gel polymer electrolyte for double layer capacitors

  • Perera, Kumudu S.;Prasadini, K.W.;Vidanapathirana, Kamal P.
    • Advances in Energy Research
    • /
    • v.7 no.1
    • /
    • pp.21-34
    • /
    • 2020
  • Energy storage devices have received a keen interest throughout the world due to high power consumption. A large number of research activities are being conducted on electrochemical double layer capacitors (EDLCs) because of their high power density and higher energy density. In the present study, an EDLC was fabricated using natural graphite based electrodes and ionic liquid (IL) based gel polymer electrolyte (GPE). The IL based GPE was prepared using the IL, 1-ethyl-3-methylimidazolium trifluoromethanesulfonate (1E3MITF) with the polymer poly(vinyl chloride) (PVC) and the salt magnesium trifluoromethanesulfonate (Mg(CF3SO3)2 - MgTF). GPE was characterized by electrochemical impedance spectroscopy (EIS), DC polarization test, linear sweep voltammetry (LSV) test and cyclic voltammetry (CV) test. The maximum room temperature conductivity of the sample was 1.64 × 10-4 Scm-1. The electrolyte was purely an ionic conductor and the anionic contribution was prominent. Fabricated EDLC was characterized by EIS, CV and galvanostatic charge discharge (GCD) tests. CV test of the EDLC exhibits a single electrode specific capacitance of 1.44 Fg-1 initially and GCD test gives 0.83 Fg-1 as initial single electrode specific discharge capacitance. Moreover, a good stability was observed for prolonged cycling and the device can be used for applications with further modifications.

Investigation of Automated Neonatal Hearing Screening for Early Detection of Childhood Hearing Impairment (소아 난청의 조기진단을 위한 신생아 청력 선별검사에 대한 평가)

  • Seo, Jeong Il;Yoo, Si Uk;Gong, Sung Hyeon;Hwang, Gwang Su;Lee, Hyeon Jung;Kim, Joong Pyo;Choi, Hyeon;Lee, Bo Young;Mok, Ji Sun
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.7
    • /
    • pp.706-710
    • /
    • 2005
  • Purpose : Early diagnosis of congenital hearing loss through the neonatal hearing screening test minimizes language defect. This research intends to identify frequency of congenital hearing loss in infants through neonatal hearing screening test with the aim of communicating the importance of hearing test for infants. Methods : From May 20, 2003 to May 19, 2004, infants were subjected to Automated Auditory Brainstem Response test during one month of birth to conduct the test with 35 dB sound. Infants who passed the 1st round of hearing test, were classified into 'pass' group whereas those who did not were classified into 'refer' group. Infants who did not 'pass' in the hearing test conducted within one month of birth were subjected to re-test one month later, and if classified as 'refer' during the re-test, they were subjected to the diagnosis for validation of hearing loss by requesting test to the hearing loss clinic. Results : There was no difference among the 'pass' and 'refer' group in terms of form of childbirth, weight at birth and gestational age. In the 1st test, total of 45 infants were classified into 'refer' group. Six among 35 who were subjected to re-test(17%) did not pass the re-test, and all were diagnosed with congenital hearing loss. This corresponds to 0.35%(3.5 per 1,000) among total number of 1,718 subjects. Conclusion : In our study the congenital hearing loss tends to be considerably more frequently than congenital metabolic disorder. Accordingly, newly born infants are strongly recommended to undergo neonatal hearing screening test.