• Title/Summary/Keyword: TEST-1

Search Result 59,887, Processing Time 0.071 seconds

A study on improvement of 2. 3. 5-Triphenyl Tetrazolium Chloride(TTC) reduction test : disc plate method (2. 3. 5-Triphenyl Terazolium Chloride(TTC) 환원시험법의 개선에 관한 연구 : disc plate method)

  • 정동수;김동훈;이상목
    • Korean Journal of Veterinary Service
    • /
    • v.18 no.2
    • /
    • pp.163-176
    • /
    • 1995
  • Triphenyl Tetrazolium Chloride(TCC) reduction test is simple and sensitive to some residual antibiotics (especially to penicillin) in milk, but comparatively insensible to sulfo-namides. The volumn of sample is also large. Thus this study was undertaken to increase the detectable level of sulfonamides in raw milk. In this study, we used small transparent plastic hole and pulp disc instead of 10m1 test tube and made test medium in which was added 0.08%TTC, 0.3% agar, 10% skim milk, approximately $10^6$ CFU/ml streptococcus thermophilus and 5ppm Trimethoprim to enhance the sensitivity for sulfonamides The results of TCC reduction test by disc plate method were summarized as follows : 1. sensitivity to residual sulfonamides were much higher than official TCC reduction test. Detectable limites of sulfamethazine, sulfamerazine, sulfathiazole, sulfachloropy-ridazine, sulfadimethoxine, sulfamononethoxine, sulfadiazine and sulfaquinoxaline were 0.1-0.5ppm levels. 2. Detectable limites to some antibiotics were simillar or good than that of official method as 0.005-0.1ppm to three ${\beta}$ -lactams, 0.25-0.5ppm to one macrolide, 2-10ppm to three aminoglycosides, 0.2-0.5ppm to three tetracycline, 0.1-0.5ppm to chloramphenicol. 3. Only 0.1ml of milk was needed to test and the test medium could be stored appnoximatly 7days in the refrigerator. So test procedure was convenient than offcial method. 4. These results suggest that disc plate method is more useful to detect bacterial growth inhibition substances including sulfonamides in raw milk.

  • PDF

Reliability Characteristics of a Package-on-Package with Temperature/Humidity Test, Temperature Cycling Test, and High Temperature Storage Test (온도/습도 시험, 온도 싸이클링 시험 및 고온유지 시험에 따른 Package-on-Package의 신뢰성)

  • Park, Donghyun;Oh, Tae Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.3
    • /
    • pp.43-49
    • /
    • 2016
  • Reliability characteristics of thin package-on-packages were evaluated using T/H (temperature/humidity) test at $85^{\circ}C/85%$ for 500 hours, TC (temperature cycling) test at $-40{\sim}100^{\circ}C$ for 1,000 cycles, and HTS (high temperature storage) test at $155^{\circ}C$ for 1,000 hours. The average resistance of the solder-bump circuitry between the top and bottom packages of 24 package-on-package (PoP) samples, which were processed using polyimide thermal tape, was $0.56{\pm}0.05{\Omega}$ and quite similar for all 24 samples. Open failure of solder joints did not occur after T/H test for 500 hours, TC test for 1,000 cycles, and HTS test for 1,000 hours, respectively.

Evaluation of Ignition Performance of Green Hypergolic Propellant (친환경 접촉점화 추진제 점화 성능 평가)

  • Sunjin Kim;Minkyu Shin;Jeongyeol Cha;youngsung Ko
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.1
    • /
    • pp.51-58
    • /
    • 2023
  • Hypergolic propellants, which can ignite themselves without an ignition source, are difficult to handle due to their corrosiveness and toxicity. Therefore, it is necessary to develop green hypergolic propellants with little or no toxicity. In this study, basic research on green hypergolic ignition propellants was conducted. With 95% hydrogen peroxide as an oxidizer and CNU_HGFv1 as a fuel, ignition and combustion characteristics of propellants were evaluated through a drop test, an ignition test, and a combustion test. As a result of the drop test, the ignition delay time was 9.7 ms. It was 27 ms in the ignition test, which was fast enough to be used as a propellant. As a result of the combustion test, a combustion efficiency of 95.4~98.1% was achieved at about 11.7 bar. It was confirmed that fast and stable combustion was possible without hard start or combustion instability.

A Study on the Standardization of the Test Method Upon Testing the Anterior Cruciate Ligament Damage Using TELOS (TELOS를 이용한 Knee Stress (Lachman)검사의 표준화에 대한 연구)

  • Lim, Jongcheon;Han, Dongkyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.2
    • /
    • pp.57-63
    • /
    • 2014
  • This study aims to find out the standardized test criteria regarding patients with the anterior cruciate ligament damage by identifying the degree of the flexion gap of femur and tibia upon bending of the anterior cruciate ligament in order to carry out the accurate test of such impairment. On the standardized test method and judgement criteria upon the anterior cruciate ligament test using Telos, it has been shown that there was no significant difference in the results according to the position of a fixed roller in the anterior cruciate ligament test for normal patients. However, in a test for patients who had undergone the anterior cruciate ligament reconstruction, it has been shown that the measured values of the anterior cruciate ligament tended to be pushed when the position of a fixed roller was less than 1cm in the test according to the position of a fixed roller of Telos (less than 1cm, more than 3cm), and this was statistically significant. The anterior cruciate ligament test (knee stress test) is a limited method used in orthopedics and rehabilitation medicine, and there have been no standardized test guidelines available yet although numerous ligament measurement tests have been performed. In addition, since the measured values are often different depending on testers even on the test that is expected to give the same result, the reproducibility of the test is still low. Accordingly, it is considered that the criteria for the anterior cruciate ligament test need to be established, and this would contribute to the accuracy of the diagnosis through the accurate test and standardized measurements.

TDX-1의 시험자동화를 위한 Test Environment 의 구현

  • Yun, Byeong-Nam;No, Cheol-U;Lee, U-Seop
    • ETRI Journal
    • /
    • v.9 no.1
    • /
    • pp.104-117
    • /
    • 1987
  • 본고는 TDX-1의 기능 및 시스팀 시험을 시험전용 컴퓨터를 사용하여 자동화시켜, 체계적이고 능률적인 시험수행과 test quality를 보장할 수 있는 test environment system에 대해 그 기능들의 설명과 그에 대한 implement 방법 및 logical, physical structure를 소개하였다.

  • PDF

Automatic Test Report Recording Program Design and Implementation for Integration Test (통합시험을 위한 자동 시험일지 작성프로그램 설계 및 구현)

  • Jeong, Younghwan;Song, Kyoungrok;Lee, Wonsik;Wi, Sounghyouk
    • KIISE Transactions on Computing Practices
    • /
    • v.24 no.1
    • /
    • pp.33-39
    • /
    • 2018
  • For the integration test in the current field of defense simulation, each actual equipment and simulator's logging information is automated. Although the event of the integrated test system is written in the test log, it is not automated, and relies on the operator's handwriting or file creation, resulting in ineffective aspects such as low-quality record content and repetition of the same content. In this study, we propose the automatic test report recording program that solves these problems. Automatic test report recording program uses framework-based technology to receive information from the test control computer and user to record a log of the test log. Automatic test report recording program allows the user to record the repeated test content in a stable manner. Additionally, even if the number of test operators is limited, the efficiency is improved so that we can fucus on the integration test.

Software Test Automation Using Data-Driven Approach : A Case Study on the Payment System for Online Shopping (데이터 주도 접근법을 활용한 소프트웨어 테스트 자동화 : 온라인 쇼핑몰 결제시스템 사례)

  • Kim, Sungyong;Min, Daihwan;Rim, Seongtaek
    • Journal of Information Technology Services
    • /
    • v.17 no.1
    • /
    • pp.155-170
    • /
    • 2018
  • This study examines a data-driven approach for software test automation at an online shopping site. Online shopping sites typically change prices dynamically, offer various discounts or coupons, and provide diverse delivery and payment options such as electronic fund transfer, credit cards, mobile payments (KakaoPay, NaverPay, SyrupPay, ApplePay, SamsungPay, etc.) and so on. As a result, they have to test numerous combinations of possible customer choices continuously and repetitively. The total number of test cases is almost 584 billion. This requires somehow automation of tests in settling payments. However, the record playback approach has difficulties in maintaining automation scripts due to frequent changes and complicated component identification. In contrast, the data-driven approach minimizes changes in scripts and component identification. This study shows that the data-driven approach to test automation is more effective than the traditional record playback method. In 2014 before the test automation, the monthly average defects were 5.6 during the test and 12.5 during operation. In 2015 after the test automation, the monthly average defects were 9.4 during the test and 2.8 during operation. The comparison of live defects and detected errors during the test shows statistically significant differences before and after introducing the test automation using the data-driven approach.

The Optimization Study on the Test Method of Remanufactured Power Steering Oil Pump by Using FMEA (FMEA를 활용한 재제조 파워스티어링 오일펌프 시험법에 대한 최적화 연구)

  • Seo, Youngkyo;Jung, Dohyun;Yu, Sangseok;Rha, Wanyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.90-98
    • /
    • 2016
  • Currently government certified test method for an automobile remanufactured products is insufficient. Thus many automotive parts in the remanufacturing market are lacking proper evaluation criteria and production of defective products are causing customer dissatisfaction. In this paper a power steering oil pump, which requires stringent manufacturing standards, is studied by the failure mode and effect analysis approach. The research suggested that the test criteria such as discharge flow characteristic test, tightness test, pulley run-out test, pressure switch operation test, low temperature test and rotation pressure durability test should be performed to evaluate the reliability of remanufactured power steering oil pumps. As a result of tests, the performance of remanufactured power steering oil pump satisfied the evaluation criteria of pressure switch operation test and low temperature test. However, the remanufactured power steering oil pump failed to satisfy the evaluation criteria on discharge performance test, tightness test and pulley run-out test. These performance evaluation tests proved the necessity of standard process for the remanufactured power steering oil pump.

Clinical characteristics of 2009 pandemic influenza A (H1N1) infection in children and the performance of rapid antigen test

  • Park, Yong-Jae;Jin, Jang-Yong;Yang, Hyeon-Jong;Lee, Woo-Ryung;Lee, Dong-Hwan;Pyun, Bok-Yang;Suh, Eun-Sook
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.10
    • /
    • pp.405-408
    • /
    • 2011
  • Purpose: In autumn 2009, the swine-origin influenza A (H1N1) virus spread throughout South Korea. The aims of this study were to determine the clinical characteristics of children infected by the 2009 H1N1 influenza A virus, and to compare the rapid antigen and realtime polymerase chain reaction (PCR) tests. Methods: We conducted a retrospective review of patients ${\geq}18$ years of age who presented to Soonchunhyang University Hospital in Seoul with respiratory symptoms, including fever, between September 2009 and January 2010. A real-time PCR test was used to definitively diagnose 2009 H1N1 influenza A infection. Medical records of confirmed cases were reviewed for sex, age, and the time of infection. The decision to perform rapid antigen testing was not influenced by clinical conditions, but by individual factors such as economic conditions. Its sensitivity and specificity were evaluated compared to real-time PCR test results. Results: In total, 934 patients tested positive for H1N1 by real-time PCR. The highest number of patients (48.9%) was diagnosed in November. Most patients (48.2%) were aged between 6 and 10 years. Compared with the H1N1 real-time PCR test results, the rapid antigen test showed 22% sensitivity and 83% specificity. Seventy-eight patients were hospitalized for H1N1 influenza A virus infection, and fever was the most common symptom (97.4%). Conclusion: For diagnosis of 2009 H1N1 influenza A virus infection, the rapid antigen test was inferior to the real-time PCR test in both sensitivity and specificity. This outcome suggests that the rapid antigen test is inappropriate for screening.

Review of pulmonary function test in terms of insurance medicine (폐기능검사의 보험의학적 이해)

  • Lee, Sinhyung
    • The Journal of the Korean life insurance medical association
    • /
    • v.33 no.2
    • /
    • pp.8-11
    • /
    • 2014
  • Pulmonary function test is a group of tests which are composed of measurement for lung function. Thy are spirometry, blood-gas analysis, lung volumes, exercise test, diffusion capacity, and bronchial challenge test. In this article, I will review the pulmonary function test and it's application in terms of clinical aspect and insurance medicine. The standard spirometric indicies are forced vital capacity(FVC), forced expiratory volume at 1 second(FEV1), and the ratio of FEV1 over FVC(FEV1/FVC). If the value of FEV1/FVC less than 70%, the examinee has obstructive ventilatory dysfunction.

  • PDF