• 제목/요약/키워드: TCSC

검색결과 79건 처리시간 0.022초

전력계통에서의 유연송전시스템 적용에 의한 미소신호안정도향상 (A study of Facts Application in power systems for the small signal Stablity Enhancement)

  • 백승도;이병준;장병훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.255-258
    • /
    • 2000
  • The supplementalγ controls of the FACTS are designed for the enhancement of the small signal stability in power system. The designed supplementary controllers using residue are applied to SVC or TCSC for the improving the damping ratio of dominant eigen value in the New England and 39 bus test system as the sample system. The results show the validation of the supplementary controller for the enhancement of the eigenvalues which have the low frequency oscillations with poor damping ratio as the unstable problem in the sample system.

  • PDF

계통의 종합적 미소신호 안정도해석에 관한 연구 (A Study on Integrated Small Signal Stability Analysis of Power Systems)

  • 남해곤;송성근;김용구;심관식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1033-1036
    • /
    • 1998
  • In this research project, two aspects of small signal stability are studied: improvement in Hessenberg method to compute the dominant electromechanical oscillation modes and siting FACTS devices to damp the low frequency oscillation. Fourier transform of transient stability simulation results identifies the frequencies of the dominant oscillation modes accurately. Inverse transformation of the state matrix with complex shift equal to the angular speed determined by Fourier transform enhances the ability of Hessenberg method to compute the dominant modes with good selectivity and small size of Hessenberg matrix. Any specified convergence tolerance is achieved using the iterative scheme of Hessenberg method. Siting FACTS devices such as SVC, STACOM, TCSC, TCPR and UPFC has been studied using the eigen-sensitivity theory of augmented matrix. Application results of the improved Hessenberg method and eigen-sensitivity to New England 10-machine 39-bus and KEPCO systems are presented.

  • PDF

한전계통의 전압안정도 향상 및 과부하 해소를 위한 80MVA UPFC(Unified Power Flow Controller) 설치 (Installation of 80MVA UPFC(Unified Power Flow Controller) for improving voltage stability and reducing heavy load in KEPCO power systems)

  • 오관일;장병훈;전영수;박상태;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.262-265
    • /
    • 2001
  • 최근 전력계통의 과부하, 전압안정도 등의 문제에 대한 해결책으로 FACTS (Flexible AC Transmission Systems)가 대두되고 있다. FACTS 설비에는 TCSC (Thyristor-Controlled Series Capacitor), SSSC (Static Synchronous Series Capacitor)와 같은 직렬 기기와 SVC(Static Var Compensator), STATCOM(STATic COMpensator) 와 같은 병렬기기 그리고, 본 논문에서 다루는 UPFC와 같은 직 병렬기기로 나누어진다. UPFC는 SSSC와 STATCOM을 결합한 형태로 유 무효전력을 동시에 보상할 수 있는 FACTS 기기이다. 본 논문에서는 한전 계통의 전압안정도 향상과 과부하 해소를 위해 강진S/S에 설치예정인 80MVA UPFC의 하드웨어 특성과 주변계통의 특성을 소개하고, UPFC와 한전 계통의 연계방안과 시험방안을 설명한다.

  • PDF

전력조류계산을 위한 SSSC모델의 개발과 연속조류계산 알고리듬에의 적용 (Development of SSSC Power Flow Model and its Implementation into Continuation Power Flow Algorithm)

  • 김슬기;송화창;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1158-1160
    • /
    • 1999
  • This paper proposes a SSSC(Static Synchronous Series Compensator) power flow model to be incorporated into power flow calculation for the steady state analysis of the power system. SSSC provides controllable compensating voltage, which is in quadrature with the line current, over an capacitive and an inductive range, independently of the magnitude of the line current. This SSSC model is obtained from the injection model for series connected VSC(Voltage Source Converter) by adding a constraint that the injected voltage should be in quadrature with the line current. In this paper the static model is implemented into the continuation power-flow (CPF) program. It is shown that SSSC has its intrinsic superiority over TCSC in controllable power flow range.

  • PDF

Fitness Sharing Particle Swarm Optimization Approach to FACTS Installation for Transmission System Loadability Enhancement

  • Chang, Ya-Chin
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.31-39
    • /
    • 2013
  • Proper installation of Flexible AC Transmission Systems (FACTS) devices in existing transmission networks can enable power systems to accommodate more power transfer with less network expansion cost. The problem to maximize transmission system loadability by determining optimal locations and settings for installations of two types of FACTS devices, namely static var compensator (SVC) and thyristor controlled series compensator (TCSC), is formulated as a mixed discrete-continuous nonlinear optimization problem (MDCP). For solving the MDCP, in the paper, the proposed method with fitness sharing technique involved in the updating process of the particle swarm optimization (PSO) algorithm, can diversify the particles over the search regions as much as possible, making it possible to achieve the optimal solution with a big probability. The modified IEEE-14 bus network and a practical power system are used to validate the proposed method.

계통의 종합적 미소신호 안정도해석에 관한 연구 (A Study on Integrated Small Signal Stability Analysis of Power Systems)

  • 남해곤;송성근;김용구;심관식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.685-688
    • /
    • 1998
  • In this research project, two aspects of small signal stability are studied: improvement in Hessenberg method to compute the dominant electromechanical oscillation modes and siting FACTS devices to damp the low frequency oscillation. Fourier transform of transient stability simulation results identifies the frequencies of the dominant oscillation modes accurately. Inverse transformation of the state matrix with complex shift equal to the angular speed determined by Fourier transform enhances the ability of Hessenberg method to compute the dominant modes with good selectivity and small size of Hessenberg matrix. Any specified convergence tolerance is achieved using the iterative scheme of Hessenberg method. Siting FACTS devices such as SVC, STACOM, TCSC, TCPR and UPFC has been studied using the eigen-sensitivity theory of augmented matrix. Application results of the improved Hessenberg method and eigen-sensitivity to New England 10-machine 39-bus and KEPCO systems are presented.

  • PDF

계통의 종합적 미소신호 안정도해석에 관한 연구 (A Study on Integrated Small Signal Stability Analysis of Power Systems)

  • 남해곤;송성근;김용구;심관식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.365-368
    • /
    • 1998
  • In this research project two aspects of small signal stability are studied: improvement in Hessenberg method to compute the dominant electromechanical oscillation modes and siting FACTS devices to damp the low frequency oscillation. Fourier transform of transient stability simulation results identifies the frequencies of the dominant oscillation modes accurately. Inverse transformation of the state matrix with complex shift equal to the angular speed determined by Fourier transform enhances the ability of Hessenberg method to compute the dominant modes with good selectivity and small size of Hessenberg matrix. Any specified convergence tolerance is achieved using the iterative scheme of Hessenberg method. Siting FACTS devices such as SVC, STACOM, TCSC, TCPR and UPFC has been studied using the eigen-sensitivity theory of augmented matrix. Application results of the improved Hessenberg method and eigen-sensitivity to New England 10-machine 39-bus and KEPCO systems are presented.

  • PDF

Available Transfer Capability Enhancement with FACTS Devices in the Deregulated Electricity Market

  • Manikandan, B.V.;Raja, S. Charles;Venkatesh, P.
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권1호
    • /
    • pp.14-24
    • /
    • 2011
  • In order to facilitate the electricity market operation and trade in the restructured environment, ample transmission capability should be provided to satisfy the demand of increasing power transactions. The conflict of this requirement and the restrictions on the transmission expansion in the restructured electricity market has motivated the development of methodologies to enhance the available transfer capability (ATC) of existing transmission grids. The insertion of flexible AC transmission System (FACTS) devices in electrical systems seems to be a promising strategy to enhance single area ATC and multi-area ATC. In this paper, the viability and technical merits of boosting single area ATC and multi-area ATC using Thyristor controlled series compensator (TCSC), static VAR compensator (SVC) and unified power flow controller (UPFC) in single device and multi-type three similar and different device combinations are analyzed. Particle swarm optimization (PSO) algorithm is employed to obtain the optimal settings of FACTS devices. The installation cost is also calculated. The study has been carried out on IEEE 30 bus and IEEE 118 bus systems for the selected bilateral, multilateral and area wise transactions.

부분 압축 명령어를 위한 캐쉬 구조의 설계 및 평가 (Design and Evaluation of Cache Structure for Semi-packed Instruction)

  • 홍원기;이승엽;김신덕
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제28권5호
    • /
    • pp.245-258
    • /
    • 2001
  • VLIW에서는 프로그램 코드를 병렬화 하는 작업이 모두 컴파일러에 의해서만 이루어진다. 따라서 병렬로 수행될 연산어들을 명시적으로 나타내 주어야 하며, 이를 위한 명령어 인코딩 방식으로 전개 인코딩 방식과 압축 인코딩 방식이 사용되어 왔다. 각 인코딩 방식들은 명령어의 적재 및 검색을 위해 서로 다른 캐쉬 구조를 필요로 하는데, 전개 인코딩 방식으로 비압축 캐쉬를 압축 인코딩 방식으로 압축 캐쉬를 사용하고 있다. 그러나 이들은 각각 무효 연산어로 인한 메모리 활용 효율 저하와 복원 과정으로 인한 명령어 인출 오버헤드의 증가라는 문제점을 안고 있다. 본 논문에서는 부분적으로 명령어 길이를 일정하게 유지하는 부분 압축 인코딩을 사용해 메모리 활용 효율을 높이는 동시에 명령어 인출 오버헤드를 줄일 수 있는 분할 캐쉬 구조를 제안한다. 각 캐쉬 구조를 구현하는데 필요한 칩 영역을 계산하여, 분할 캐쉬가 비교적 비용 효율적인 캐쉬 구조임을 확인하였다. 모의 실험을 통한 메모리 활용 효율 측정 결과 하드웨어 비용의 증가를 고려하더라도 분할 캐쉬는 비압축 캐쉬에 비해 최고 약 3배의 메모리 활용 효율을 얻을 수 있었다. 각 캐쉬 구조를 일차 캐쉬로 하는 VLIW 시스템들의 성능 측정 결과는 TCSC(블록 집중형 분할 캐쉬)를 사용한 시스템이 비용 대비 성능 면에서 가장 우수한 것으로 나타났다.

  • PDF