• Title/Summary/Keyword: TCD

Search Result 174, Processing Time 0.028 seconds

Radiation-induced thermal conductivity degradation modeling of zirconium

  • Sangil Choi;Hyunmyung Kim;Seunghwan Yu
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1277-1283
    • /
    • 2024
  • This study presents a radiation-induced thermal conductivity degradation (TCD) model of zirconium as compared to the conventional UO2 TCD model. We derived the governing factors of the radiation-induced TCD model, such as maximum TCD value and temperature range of TCD. The maximum TCD value was derived by two methods, in which 1) experimental result of 32 % TCD was directly utilized as the maximum TCD value and 2) a theoretical approach based on dislocation was applied to derive the maximum TCD value. Further, the temperature range of TCD was determined to be 437-837 K by 1) experimental results of post-annealing of irradiation hardening as compared to 2) the rate theory and thermal equilibrium. Consequently, the radiation-induced TCD model of zirconium was derived to be $f_r=1-{\frac{0.32}{1+{\exp}\,\{(T-637)/45\}}}$. Because the thermal conductivity of zirconium is one of the factors determining the storage and transport system, this newly proposed model could improve the safety analysis of spent fuel storage systems.

Prevalence of Patent Foramen Ovale and Diagnostic Efficacy of Transcranial Doppler Sonography in Cryptogenic Ischemic Stroke Patients

  • Kim, Dae-Sik;Kim, Byung-Weon;Cho, Sung-Jun
    • Biomedical Science Letters
    • /
    • v.15 no.1
    • /
    • pp.17-23
    • /
    • 2009
  • The prevalence of patent foramen ovale (PFO) in healthy persons was estimated as about $10{\sim}25%$ and was up to 40% in patients with stroke. Transesophageal echocardiography (TEE) was considered to be the most sensitive method to detect PFO and was used as the gold standard. Transcranial doppler sonography (TCD) of the middle cerebral artery (MCA) during a contrast (saline bubble) injection has recently been proposed as an alternative detecting method for PFO. In this study, we would like to know the difference between TCD value and TEE value in subjects with cryptogenic ischemic stroke. We performed TCD and TEE tests to detect PFO on 64 patients (30 women and 34 men, mean age was 59.4 years) with cryptogenic ischemic stroke. PFO prevalence through TCD was 45.3% (29 of 64 patients) and the prevalence through TEE was 34.4% (22 of 64 patients). There was no statistical significance between PFO test and TCD test (P=0.206). But TCD had a sensitivity of 90.9% (20 of 22 patients), specificity of 78.6% (33 of 42 patients), positive predictive value of 69.0% (20 of 29 patients), and negative predictive value of 94.3% (33 of 35 patients). We concluded that TCD was a highly sensitive method for detecting a right-left shunt. Therefore, the non-invasive TCD test is a method more effective than the anti-invasive TEE test in the cost and evaluation of the existence or nonexistence of right to left shunt in addition to the screening method of the cerebrovascular disorder. Considering these points, TCD test could be recommended for patients with cryptogenic ischemic stroke as a useful and convenient method for screening of the existence or nonexistence of a right to left shunt caused by PFO.

  • PDF

The Technique and Normal Values of Transcranial Doppler Ultrasonography(TCD) (Transcranial Doppler Ultrasonography (TCD)의 시행 방법 및 정상치)

  • Sohn, Young Ho
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.1
    • /
    • pp.39-46
    • /
    • 1999
  • Transcranial doppler ultrasonography (TCD) is a new, non-invasive and easily applicable method to evaluate cerebral hemodynamics. Last 10 years, its use in Korea has been dramatically expanded, but the qualification of TCD laboratory has yet to be settled. Since duplex sonography is seldom used in Korea, we have to depend totally on TCD to evaluate cerebral hemodynamic changes. Thus, all of the available data from every detectabler cerebral arteries has to be obtained for accurate interpretation of TCD measurements. Moreover, flow direction and wave form should be concerned in addition to the flow velocity. In this article, I present technique to measure the anterior, meddle and posterior cerebral arteries, the internal carotid artery siphon and at cervical level, and the vertebral and the basilar artery, and normal values for these measurements which is essential for the adequate interpretation.

  • PDF

Application of Transcranial Doppler Ultrasonography(TCD) for the Diagnosis of Migraine : Preliminary Results (Transcranial Doppler Ultrasonography를 이용한 편두통의 진단: 예비연구)

  • Lee, Young-Seok;Kim, Byung-Kun
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.1
    • /
    • pp.31-35
    • /
    • 1999
  • Dignosis of migraine is only based on the medical history, and objective methods to aid the clinical diagnosisare absent. Although transcranial Doppler ultrasonography (TCD) abnormalities in headache-free migraineurs have been reported previously, diagnostic criteria for migraine is still lacking and this may limit the practical application of TCD for migraine. We prospectively studied several abnormal TCD indices in interictal migraineurs and their sensitivity and specificity to define the optimal diagnostic criteria. Young (20 yrs$age=29.0{\pm}6.1yrs$) were compared to 69 controls (M:F=25:44, Mean $age=31.2{\pm}5.5yrs$). Elevated MFV (> 2SD)was observed in 63% of migraineurs while n 12% of control (p<0.01). High AI (>25%) or high HI (>3.0) was present in 17% of migraineurs, while 3% and none in controls (p<0.01). Sensitivity of elevated MFV, high AI, and high HI was 63%, 17%, 17% and specificity was 88%, 97%, 100%, respectively. If all these indices were combined, sensitivity and specificity reached 69% and 86%. These preliminary results suggest pathophysiological implication of vasospasm in interictal migraineurs, and TCD may be practically applicable for migraine. Optimal diagnostic criteria and therapeutic options for patients with abnormal TCD findings remain to bo determined.

  • PDF

Detection of Clostridium difficile by Loop-Mediated Isothermal Amplification (등온증폭법을 이용한 Clostridium difficile 검출)

  • In, Ye-Won;Ha, Su-Jeong;Yang, Seung-Kuk;Oh, Se-Wook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.9
    • /
    • pp.1326-1330
    • /
    • 2012
  • This study was conducted to develop a loop-mediated isothermal amplification (LAMP) method for the detection of Clostridium difficile. The tested target gene was 16S ribosomal RNA. Five different LAMP primer sets were designed, and LAMP was performed. All primer sets targeting the 16S rRNA gene (BIP, FIP, B3, F3, LF, PF) were determined as positive in tcdA-positive, tcdB-postive ($A^+B^+$) and tcdA-negative, tcdB-negative ($A^-B^-$) Clostridium difficile strains. As the LAMP reaction took less than 80 min and did not require expensive machine such as thermocycler, it can be used as a rapid and simple detection method for foodborne pathogens.

Deep Learning Based TSV Hole TCD Measurement (딥러닝 기반의 TSV Hole TCD 계측 방법)

  • Jeong, Jun Hee;Gu, Chang Mo;Cho, Joong Hwee
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.2
    • /
    • pp.103-108
    • /
    • 2021
  • The TCD is used as one of the indicators for determining whether TSV Hole is defective. If the TCD is not normal size, it can lead to contamination of the CMP equipment or failure to connect the upper and lower chips. We propose a deep learning model for measuring the TCD. To verify the performance of the proposed model, we compared the prediction results of the proposed model for 2461 via holes with the CD-SEM measurement data and the prediction results of the existing model. Although the number of trainable parameters in the proposed model was about one two-thousandth of the existing model, the results were comparable. The experiment showed that the correlation between CD-SEM and the prediction results of the proposed model measured 98%, the mean absolute difference was 0.051um, the standard deviation of the absolute difference was 0.045um, and the maximum absolute difference was 0.299um on average.

Near-Infrared Spectroscopy versus Transcranial Doppler-Based Monitoring in Carotid Endarterectomy

  • Cho, Jun Woo;Jang, Jae Seok
    • Journal of Chest Surgery
    • /
    • v.50 no.6
    • /
    • pp.448-452
    • /
    • 2017
  • Background: Proper monitoring of cerebral perfusion during carotid artery surgery is crucial for determining if a shunt is needed. We compared the safety and reliability of near-infrared spectroscopy (NIRS) w ith transcranial Doppler (TCD) for cerebral monitoring. Methods: This single-center, retrospective review was conducted on patients who underwent carotid endarterectomy (CEA) using selective shunt-based TCD or NIRS at Daegu Catholic University Medical Center from November 2009 to June 2016. Postoperative complications were the primary outcome, and the distribution of risk factors between the 2 groups was compared. Results: The medical records of 74 patients (45 TCD, 29 NIRS) were reviewed. The demographic characteristics were similar between the 2 groups. One TCD patient died within the 30-day postoperative period. Postoperative stroke (n=4, p=0.15) and neurologic complications (n=10, p=0.005) were only reported in the TCD group. Shunt usage was 44.4% and 10.3% in the TCD and NIRS groups, respectively (p=0.002). Conclusion: NIRS-based selective shunting during CEA seems to be safe and reliable for monitoring cerebral perfusion in terms of postoperative stroke and neurologic symptoms. It also reduces unnecessary shunt usage.

Is Transcranial Doppler Ultrasonography Old-fashioned?: One Institutional Validity Study

  • Han, Pan-Yeal;Kim, Jae-Hoon;Kang, Hee-In;Moon, Byung-Gwan;Lee, Seung-Jin;Kim, Joo-Seung
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.2
    • /
    • pp.63-66
    • /
    • 2008
  • Objective : The purpose of this study is to investigate the correlation between various transcranial Doppler (TCD) ultrasonography parameters and clinical vasospasm after aneurysmal subarachnoid hemorrhage (SAH). Methods : This study enrolled 40 patients presented with aneurysmal SAH between September 2006 and August 2007. We measured differences of mean blood flow velocity (BFVm), highest systolic blood flow velocity (BFVh), and Lindegaard ratio (LR) in the middle cerebral artery on TCD examination. These parameters were evaluated for correlation with clinical vasospasm by univariate analysis and the receiver operating characteristic analysis. Results : Twelve patients (30%) developed clinical vasospasm. The best TCD parameters for the detection of clinical vasospasm were revealed to be differences of BFVm, BFVh, and LR values between $1^{st}$ TCD test and $3^{rd}$ TCD (7 cm/s. 11.5 cm/s, 0.45 respectively). The positive predictive value of anyone of three parameters was 60% and the negative predictive value was 100%. Conclusion : TCD is still considered a useful tool for screening clinical vasospasm. To confirm the predictive value of the above parameters. further prospective study will be needed.

Correlation of Gender/Age and Measurement Indices of Transcranial Doppler Ultrasonography (경두개 도플러 초음파의 측정지표와 성/연령의 상관성)

  • Jin, Bok-Hee
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.42 no.3
    • /
    • pp.155-160
    • /
    • 2010
  • Transcranial Doppler ultrasonography (TCD) allows measurement of blood flow velocity to be made from the basal intracerebral vessels. Blood flow velocity in TCD is highly affected not only by blood vessel diameter, blood flow volume, blood viscosity, but also age and sex. Therefore, the study is focused on the correlation between TCD measurement index and sex/age. Subjects were 214 (male 147, famale 67) who had TCD for headache and stroke evaluations at Dongguk University Ilsan Hospital neurology department from December 2009 to April 2010. Sex did not show significant differences with mean flow velocity (MFV), peak systolic flow velocity (PSFV), end diastolic flow velocity (EDFV), pulsatility index (PI) and resistance index (RI) in middle cerebral artery (MCA). Although age also did not show significant differences with MFV and PSFV, EDFV has statistically decreased with age, and PI and RI has statistically increased with age. In addition, age showed significant correlation with MFV, EDFV, PI and RI, but not with PSFV. Therefore, TCD is definitely correlated with age and sex, so that those influencial factors must be considered when being tested.

  • PDF

Transcranial Doppler Ultrasonography(TCD) in diagnosis of Cerebrovascular Accident (CVA) (뇌졸중의 진단에 대한 TCD의 활용 (Brain CT, Brain MRI와 Transcranial Doppler Ultrasonography 비교를 통한 뇌졸중 진단의 상호 보완에 관한 연구))

  • Park, Se-Gi;Kang, Myeong-Seog;Jun, Chan-Yong;Park, Chong-Hyeong
    • The Journal of Korean Medicine
    • /
    • v.17 no.1 s.31
    • /
    • pp.171-189
    • /
    • 1996
  • Background and Purpose: The greater part of patients to visit Hospital of Oriental Medicine suffer from cerebrovascular accident(CVA). There is transcranial Doppler(TCD) in the diagnostic method to confirm cerebrovascular accident(CVA). Transcranial Doppler(TCD) is an accurate method of monitoring the blood flow velocities of the cerebral vessels and have been generally used to prevent symptomatic vasospasm and confirm cerebral infarction. So we studied, in the crebrovascular accident(CVA), to estimate whether transcranial Doppler(TCD) is useful to. Methods: Using transcranial doppler(Multigon Model 500M Transcranial Doppler System), we measured the mean and peak velocity and the direction of blood flow in 10 cerebrovascular accident(CVA)'s subjects who had been examined by Computed Tomography(CT) or Magnetic Resonance Imaging (MRI). Results : As an anticipation, in cerebrovascular accident(CVA)'s subject with Cb-infarction, the mean and peak velocity of blood flow fell down remarkably and the direction of blood flow was change or irritable. But didn't find out any signal in lacunar infarction. Also, in case with spontaneous hemorrhage, the velocity and direction of blood flow was change but this signal was short of diagnosis for Cb-hemorrhage. Besides, we found signals about embolism, stenosis, thrombosis and occlusion in cerebrovascular accident(CVA)'s subjects. Conclusion: In Cb-infarction, the result of TCD was equal to diagnosis with Computed Tomography(CT) or Magnetic Resonance Imaging (MRI). But about lacunar infarction or spontaneous hemorrhage, signals of TCD couldn't be found out or was insufficient more than Computed Tomography(CT) or Magnetic Resonance Imaging(MRI). In cerebrovascular accident(CVA)'s subject with embolism, stenosis, thrombosis or occlusion, signals of TCD were found out more than Computed Tomography(CT) or Magnetic Resonance Imaging(MRI). Therefore transcranial doppler(TCD) is necessary method which makes a diagnosis of cerebrovascular accident(CVA), with Computed Tomography(CT) or Magnetic Resonance Imaging(MRI).

  • PDF