• 제목/요약/키워드: TAP2

검색결과 917건 처리시간 0.026초

Effect of intracanal medications on the interfacial properties of reparative cements

  • Pereira, Andrea Cardoso;Pallone, Mariana Valerio;Marciano, Marina Angelica;Cortellazzi, Karine Laura;Frozoni, Marcos;Gomes, Brenda P.F.A.;de Almeida, Jose Flavio Affonso;de Jesus Soares, Adriana
    • Restorative Dentistry and Endodontics
    • /
    • 제44권2호
    • /
    • pp.21.1-21.8
    • /
    • 2019
  • Objectives: The purpose of the present study was to evaluate the effect of calcium hydroxide with 2% chlorhexidine gel (HCX) or distilled water (HCA) compared to triple antibiotic paste (TAP) on push-out bond strength and the cement/dentin interface in canals sealed with White MTA Angelus (WMTA) or Biodentine (BD). Materials and Methods: A total of 70 extracted human lower premolars were endodontically prepared and randomly divided into 4 groups according to the intracanal medication, as follows: group 1, HCX; group 2, TAP; group 3, HCA; and group 4, control (without intracanal medication). After 7 days, the medications were removed and the cervical third of the specimens was sectioned into five 1-mm sections. The sections were then sealed with WMTA or BD as a reparative material. After 7 days in 100% humidity, a push-out bond strength test was performed. Elemental analysis was performed at the interface, using energy-dispersive spectroscopy. The data were statistically analyzed using analysis of variance and the Tukey test (p < 0.05). Results: BD presented a higher bond strength than WMTA (p < 0.05). BD or WMTA in canals treated with calcium hydroxide intracanal medications had the highest bond strength values, with a statistically significant difference compared to TAP in the WMTA group (p < 0.05). There were small amounts of phosphorus in samples exposed to triple antibiotic paste, regardless of the coronal sealing. Conclusions: The use of intracanal medications did not affect the bond strength of WMTA and BD, except when TAP was used with WMTA.

서울지역 급식 국민학교의 음용수 수질에 관한 연구 (A Study on the Drinking Water Quality for Primary Lunch School in Seoul)

  • 이원묘;이용옥;방형애
    • 한국환경보건학회지
    • /
    • 제21권1호
    • /
    • pp.7-20
    • /
    • 1995
  • The aims of this study are to enhance the students' knowledge of the drinking water and its reliability by investigating drinking water situation on the drinking water. The results are as following 1. Status and drinking behavior about school drinking water (1) 97.82% of the schools are using the tap water as the resource of drinking water. (2) 46 schools are in possession of water tank and 18 schools of them are using the water tank as the resource of drinking water. The clearing and sanitization of the tank are carried out once in a year with hypochloronatrium by the low-level officials. (3) 51.28% of the schools are providing the students with drinking water and 75% of them with boiled water. The drinking water supply managers are low-level officials, nurse teachers, and dietitian. 2. Analysis of the drinking water quality (1) Most of the drinking water provided by the school are tap water 35.8%, barely tea 5.85%, filtered water 6.3%, ground water 1.1% and all turned out to be suitable for drinking. (2) The drinking water carried from home turned out to be unsuitable for drinking except pH criterion, especially the test of APC(Aerobic Plate Count) and Coliform group showed worse degree. These results were caused by the hygiene problem and maltreatment in water container.

  • PDF

수도권상수도의 수질-문제점과 대책 (Tap Water Quality in Seoul Metropolitan Area)

  • 김동치
    • 환경위생공학
    • /
    • 제5권2호
    • /
    • pp.15-21
    • /
    • 1990
  • Current analyses of tap water in Seoul metropolitan area prove the water is still safe, despite the Pollution of raw water source. However, it also significantly suggests that a feasibility study of apply, additional advanced technology to existing water treatment processes is needed in order to cope with future pollution. Also, the monitoring of water quality within private, multi-household buildings is important as the monitoring of public water distribution system.

  • PDF

Audio Sampling Rate Conversion Block의 설계 (Design of Audio Sampling Rate Conversion Block)

  • 정혜진;심윤정;이승준
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.827-830
    • /
    • 2003
  • This paper proposes an area-efficient FIR filter architecture for sampling rate conversion of hi-fi audio data. Sampling rate conversion(SRC) block converts audio data sampled at 96KHz down to 48KHz sampled data and vice versa. 63-tap FIR filter coefficients have been synthesized that gives 100dB stop band attenuation and 5.2KHz transition bandwidth. Time-shared filter architecture requires only one multiplier and accumulator for 63-tap filter operation. This results in huge hardware saving of up to 10~19 times smaller compared with traditional FIR structure.

  • PDF

비디오 코딩을 위한 필터링 (Filtering for Video Coding)

  • 임수연;이영렬
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송∙미디어공학회 2022년도 하계학술대회
    • /
    • pp.192-194
    • /
    • 2022
  • 본 논문에서는 VVC(Versatile Video Coding) 화면 내 예측에서 참조 샘플 생성의 정확도를 높이기 위해 블록의 크기와 방향성 모드에 따라 더 많은 정수 위치 참조 샘플을 이용하는 보간 필터를 추가적으로 사용하는 방법을 제안한다. VVC 표준에서 4-tap 보간 필터를 사용하는 기존의 방식에 추가로 8-tap 보간 필터를 함께 사용하여 VVC 참조 소프트웨어인 VTM(VVC Test Model) 14.2[1] 대비 평균 -0.16% 의 luma BD-rate 개선을 보였다.

  • PDF

D 정수장 소독부산물 예측모델 선정 (Predictive Model Selection of Disinfection by-products (DBPs) in D Water Treatment Plant)

  • 김성준;이형원;황정석;원찬희
    • 한국물환경학회지
    • /
    • 제26권3호
    • /
    • pp.460-467
    • /
    • 2010
  • For D-WTP's sedimentation basin and distribution reservoir, and water tap the predictive models proposed tentatively herein included the models for estimating TTHM concentration in precipitated water, for treated water and for tap water, and the estimated correlation formula between treated water's TTHM concentration and tap water. As for TTHM-concentration predictive model in sedimentation water, the coefficient of determination is 0.866 for best-fitted short-term $DOC{\times}UV_{254}$ based Model (TTHM). As for $HAA_5$-concentration predictive model in sedimentation water, the coefficient of determination is 0.947 for the suitable $UV_{254}$-based model ($HAA_5$). In case of the predictive model in treated water, the coefficient of determination is 0.980 for best-fitted $DOC{\times}UV_{254}$ based model (TTHM) using coagulated waters, while the coefficient of determination is 0.983 for best-fitted $DOC{\times}UV_{254}$ based model ($HAA_5$) using coagulated waters, which described the $HAA_5$ concentration well. However, the predictive model for tap water could not be compatible with the one for treated water, only except for possibility inducing correlation formula for prediction, [i.e., the correlation formula between TTHM concentration and tap water was verified as TTHM (tap water) = $1.162{\times}TTHM$ (treated water), while $HAA_5$ (tap water) = $0.965{\times}HAA_5$ (treated water).] The correlation analysis between DOC and $KMnO_4$ consumption by process resulted in higher relationship with filtrated water, showing that its regression is $DOC=0.669{\times}KMnO_4$ consumption - 0.166 with 0.689 of determination coefficient. By substituting it to the existing DOC-based model ($HAA_5$) for treated water, the consequential model formula was made as follows; $HAA_5=8.35(KMnO_4\;consumption{\times}0.669-0.166)^{0.701}(Cl_2)^{0.577}t^{0.150}0.9216^{(pH-7.5)}1.022^{(Temp-20^{\circ}C)}$

인천광역시 지하철 역사 내 지하수 및 수돗물의 라돈 위해성 검토 (Radon Hazard Review of Spilled Groundwater and Tap Water in Incheon Metropolitan City Subway Station)

  • 이유상;이상복;강민석;정동하;김진홍;오윤식;최세린;박정수;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.671-677
    • /
    • 2021
  • Interest in the everyday hazards of radon has recently increased as such, this study attempted to examine the dangers of radon in spilled groundwater by comparing the radon concentrations of the drained groundwater and tap water used in recirculating systems in Incheon Subway restrooms. At five stations of Incheon Subway Line 1 and three stations of Line 2, drained groundwater is recirculated and used in restrooms for toilet flushing. Stations restroom tap water for hand washing that used as a control and the measured values of each were compared. With the cooperation of Incheon Transportation Corporation, samples of spilled groundwater and tap water were collected sealed to prevent contact with the air, and a DURRIDGE RAD7 was used as the experimental equipment. The collected samples were subjected to radial equilibration for approximately 3.5 h, at which the radon concentration reached its maximum, and then calculated as 10 measurements using the RAD7 underwater radon measurement mode. In all eight stations, the radon concentration in tap water was lower than the recommended amount. However, in an average of 7 out of the eight stations, the radon concentration in the effluent groundwater was 100 times higher than that in tap water. Since high radon concentrations in groundwater runoff can be harmful to humans, and there is no accurate standard for radon concentrations in domestic water, it is necessary to continuously monitor radon in water and prepare a guidance of recommended values.

TAp73 and ΔNp73 Have Opposing Roles in 5-aza-2'-Deoxycytidine-Induced Apoptosis in Breast Cancer Cells

  • Lai, Jing;Yang, Fang;Zhang, Wenwen;Wang, Yanru;Xu, Jing;Song, Wei;Huang, Guichun;Gu, Jun;Guan, Xiaoxiang
    • Molecules and Cells
    • /
    • 제37권8호
    • /
    • pp.605-612
    • /
    • 2014
  • The p73 gene contains an extrinsic P1 promoter and an intrinsic P2 promoter, controlling the transcription of the pro-apoptotic TAp73 isoform and the anti-apoptotic ${\Delta}Np73$ isoform, respectively. The DNA methylation status of both promoters act equally in the epigenetic transcriptional regulation of their relevant isoforms. The aim of this study was to analyze the different effects of these p73 isoforms in 5-aza-2'-deoxycytidine (5-aza-dC)-induced apoptosis in breast cancer cells. We investigated the effects of the DNA demethylation agent, 5-aza-dC, on the T-47D breast cancer cell line, and evaluated the methylation status of the p73 promoters and expression of TAp73 and ${\Delta}Np73$. Furthermore, we assessed the expression of p53 and p73 isoforms in 5-aza-dC-treated T-47D cells and p53 knockout cells. 5-aza-dC induced significant anti-tumor effects in T-47D cells, including inhibition of cell viability, G1 phase arrest and apoptosis. This was associated with p73 promoter demethylation and a concomitant increase in TAp73 mRNA and protein expression. In contrast, the methylation status of promoter P2 was not associated with ${\Delta}Np73$ mRNA or protein levels. Furthermore, demethylation of P2 failed to inhibit the expression of ${\Delta}Np73$ with 5-aza-dC in the p53 knockdown cell model. Our study suggests that demethylation of the P1 and P2 promoters has opposite effects on the expression of p73 isoforms, namely up-regulation of TAp73 and down-regulation of ${\Delta}Np73$. We also demonstrate that p53 likely contributes to 5-aza-dC-induced ${\Delta}Np73$ transcriptional inactivation in breast cancer cells.

설계도서를 중심으로 본 1910년대 탑골공원의 성립과정 (1910's Tap-gol Park Construction Process through Design Document Interpretation)

  • 김해경;김영수;윤혜진
    • 한국전통조경학회지
    • /
    • 제31권2호
    • /
    • pp.103-117
    • /
    • 2013
  • 본 연구는 탑골공원의 조성 논의가 시작된 1897년부터 공원 형태가 완성된 1916년까지 약 20년 동안 작성된 설계도면을 1차 사료로 활용하여 공간 구성요소의 변화를 통한 공원 성격의 형성과정을 분석했다. 이에 도출된 결과는 다음과 같다. 첫째, 1897년에서 1904년까지는 왕실 소유의 공원으로 탑골공원이 조성되는 시기이다. 고종의 근대 국가 건설을 위해서 1897년 조성 논의의 시작과 1899년 민가를 철거하여 거북이 모양의 공원 평면을 바탕으로 담장 남문 북문 조성하여 1902년 개원하였다. 1903년에는 이왕직 음악대의 연주 장소로 팔각정이 도입되었고, 연주에 부적합하다고 판단되어 1904년 호자식 음악당이 축조되었다. 이 시기는 일요일에만 개방되는 이왕직 소유의 공원이었다. 둘째, 1910년에서 1913년까지는 일반인에게 공개되어 이용이 활발해지는 시기이다. 주변 시설로 인해 경계부가 변형되었으며, 이용자를 배려한 휴양시설과 편익시설이 보완되었다. 1913년 8월에는 야간 개방이 이루어 졌는데, 이는 1910년대 일제에 의해서 도시풍 오락의 장소로 탑골공원이 이용되었기 때문이다. 셋째, 1914년에서 1916년까지 상업시설이 도입된 시기이다. 1914년 상업시설로 끽다점인 청목당이 들어섰으며, 주변에 연못과 등나무 그늘시렁이 조성되었다. 1916년 종로 야시의 시작으로 탑골공원 이용은 더욱 활발해졌으며, 휴양시설과 편익시설의 확충과 관리를 위한 경계울타리와 관리사무소가 설치되었다. 기존의 호자식 음악당이 철거되고 용산군주차사령부에서 가제보형 음악당이 이축되었다. 1916년에 이르러서야 비로소 1922년 개벽 에 등장하는 탑골공원의 이용 행태와 부합하는 공원형태가 완성되었다. 본 연구는 일제강점기에 작성된 공원 설계도면의 발굴이라는 사료적 가치, 기존 연구의 오류를 수정할 수 있는 근거 제시, 근대 조경공간에 사용된 공간 구성요소와 재료에 대한 탐구로써 의의를 지닌다.

Importance of pulmonary valve morphology for pulmonary valve preservation in tetralogy of Fallot surgery: comparison of the echocardiographic parameters

  • Choi, Su Jin;Kwon, Jung Eun;Roh, Da Eun;Hyun, Myung Chul;Jung, Han Na;Lee, Young Ok;Cho, Joon Yong;Kim, Yeo Hyang
    • Clinical and Experimental Pediatrics
    • /
    • 제63권5호
    • /
    • pp.189-194
    • /
    • 2020
  • Background: The decision to use transannular patching (TAP) during tetralogy of Fallot (TOF) repair depends on the pulmonary valve annulus size; the z score of the pulmonary annulus is the most commonly used predictor. However, definitive results are not obtained with z scores as different z score data sets are used for different parameters. Purpose: This study aimed to identify the echocardiographic and other key factors that warranted a change in the surgical method during TOF surgery. Methods: Sixty-two patients were enrolled and divided into a pulmonary valve (PV) preservation group and a TAP group. Their medical records were reviewed. Results: The z score for PV annulus (PVA), ratio of the PVA to aortic annulus size, and ratio of PVA to descending aorta (DAO) size were significantly different between the PV preservation and TAP groups (-1.72±1.52 vs. -3.07±1.94, P=0.004; 0.62±0.12 vs. 0.50±0.14, P=0.002; and 1.32±0.32 vs. 1.07±0.36, P=0.008, respectively). For TAP repair, the PVA z score had a sensitivity of 65.4% and specificity of 73.1%, ratio of PVA to aortic annulus size had a sensitivity of 73.1% and specificity of 65.4%, and ratio of PVA to DAO size had a sensitivity of 69.2% and specificity of 57.7%. The TAP group showed more monocuspid PVs (P=0.011), while the PV preservation group showed more tricuspid PVs (P=0.027). Commissurotomy was more frequently performed in the PV preservation group than in the TAP group (P=0.001). Of patients with commissurotomy, 58% showed a PV z score<-2. Conclusion: Although various echocardiographic parameters may serve as predictors for determining surgical methods for TOF patients, the PV morphology and tissue characteristics should also be considered.