• Title/Summary/Keyword: TAP device

Search Result 58, Processing Time 0.022 seconds

Study in the Development of Motion Recognition Tap-water using Ultrasonic Sensors (초음파 센서를 이용한 모션 인식 수도꼭지 개발 및 연구)

  • Kim, Dong-Hyun;Ryu, Jae-Hoo;Ju, Jong-Soo;Ahn, Jong-Pil;Kim, Jae-Wook
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.2
    • /
    • pp.309-316
    • /
    • 2022
  • Advances in technology have improved people's lives comfortably and have developed more easily, safely and simply. We usually turn on hot water to set the temperature of the water in the bathroom and gradually adjust the temperature to find the temperature we want with our skin. In this situation, I thought, "What if there is a device that can see the temperature of water with my eyes and help with the interior of the bathroom while including a safe system," and tried to create a system that values stability. For example, if a child accidentally changes the temperature of the water to high temperature while washing, he or she can get burned. And the biggest purpose is to secure better safety by adding LCDs and LEDs so that we can visually know the temperature before feeling it tactilely. As a result of the experiment, there was no error between the temperature detected by the water temperature sensor and the temperature displayed on the LCD, and no error occurred up to 27 cm in the distance measurement experiment using the ultrasonic sensor. There has been an error of about 2% since 28cm or older, but there is no significant inconvenience in using it within the category of faucets.

Adaptive Decision Feedback Equalizer using the hierarchical Feedback filter and Soft decision device (계층적 궤환 필터 구조와 연판정 장치를 갖는 적응형 결정 궤환 등화기)

  • Lim, Dong-Guk;Song, Jeong-Ig;Kim, Jae-Mong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.1
    • /
    • pp.138-145
    • /
    • 2007
  • Wireless transmission system using the multipath channel is affected ISI due to the delay spread. So we use a decision feedback equalizer which consist of decision part and feedback filter for remove the ISI effectively. In this paper, we propose a improved adaptive decision feedback equalizer to mitigate ISI effectively. The proposed adaptive decision feedback equalizer is construct by using soft decision device and hierarchical feedback filter based on MMSE sub-optimal equalizer using the LMS algorithm. Soft decision device mitigate the error propagation in feedback filter by incorrectly detected decision symbol and feedback filter which is divided two step independently mitigate the ISI by using a adaptive algorithm. As a result this structure shows better performance than conventional decision feedback equalizer by mitigating the error propagation in filter cause incorrectly detecting symbol. and we get the MSE more rapidly by using larger step-size due to reduce the number of feedback filter tap. In computer simulation, we compare the bit error rate performance of proposed decision feedback equalizer with conventional one on the S-V channel model for UWB system.

A Development of Monitoring and Control System for Improved the Voltage Stability in the Power System (전력계통의 전압안정도향상을 위한 감시제어시스템 개발)

  • Lee, Hyun-Chul;Jeoung, Ki-Suk;Park, Ji-Ho;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.437-443
    • /
    • 2013
  • This paper was developed a monitoring and control system to use reactive power control algorithm. This algorithm could be improved voltage stability in power system. This method was controlled the voltage for stability improvement, effective usage of reactive power, and the increase of the power quality. PMS(Power Management System) has been calculate voltage sensitivity, and control reactive power compensation device. The voltage control was used to the FACTS, MSC/MSR(Mechanically Switched Capacitors/Reactors), and tap of transformer in power system. The reactive power devices in power system were control by voltage sensitivity ranking of each bus. Also, to secure momentary reactive power, it had been controlled as the rest of reactive power in the each bus. In here, reactive power has been MSC/MSR. The simulation result, First control was voltage control as fast response control of FACTS. Second control was voltage control through the necessary reactive power calculation as slow response control of MSR/MSR. Third control was secured momentary reactive reserve power. This control was method by cooperative control between FACTS and MSR/MSC. Therefore, the proposed algorithm was had been secured the suitable reactive reserve power in power system.

The Extraction of Table Lines and Data in Document Image (문서영상에서 표 구성 직선과 데이터 추출)

  • Jang, Dae-Geun;Kim, Eui-Jeong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.3
    • /
    • pp.556-563
    • /
    • 2006
  • We should extract lines and data which consist of the table in order to classify the table region and analyze its structure in document image. But it is difficult to extract lines and data exactly because the lines are cut and their lengths are changed, or characters or noises are merged to the table lines. These problems result from the error of image input device or image reduction. In this paper, we propose the better method of extracting lines and data for table region classification and structure analysis than the previous ones including commercial softwares. The prposed method extracts horizontal and vertical lines which consist of the table by the use of one dimensional median filter. This filter not only eliminates the noises which attach to the line and the lines which are orthogonal to the filtering direction, but also connects the cut line of which the gap is shorter than the length of the filter tap in the process of extracting lines to the filtering direction. Furthermore, texts attached to the line are separated in the process of extracting vertical lines. This is an example of ABSTRACT format.

The Performance Comparison of MMA and S-MMA Adaptive Equalization Algorithm for QAM Signal (QAM 신호에대한 MMA와 S-MMA 적응 등화 알고리즘의 성능 비교)

  • Kang, Dae-Soo;Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.1
    • /
    • pp.19-26
    • /
    • 2013
  • This paper deals with the performance comparison of blind adaptive equalization algorithm, the MMA and S-MMA, that is used for compensation of the amplitude and phase distortion simultaneously which occurs in the time dispersive channel. The present CMA algorithm is possible to compensates the amplitude only, but not in phase, so it needs to the another additional circuit for compensating the phase. In order to overcoming the abovemensioned shorthand, the improved cost function is applied to the MMA algorithm. In MMA algorithm, the error is consists of the dispersion constant only, but in S-MMA, the error is consists of the dispersion constant considering the output of decision device (sliced symbol) in order to updating the tap coefficients. By using the two kind error signal, the adaptive equalization algorithm has different performance. In this paper, we compare to the adaptive equalization algorithm performance by using the recovered constellation, residual isi, MD (Maximum Distortion) and SER as a index when the transmitting signal is 16 and 64-QAM and then passing through the same communication channel. As a result of simulation, the S-MMA can improving the Roburstness in SER performance compared to the MMA in the high order QAM signal.

Taxonomy of Performance Shaping Factors for Human Error Analysis of Railway Accidents (철도사고의 인적오류 분석을 위한 수행도 영향인자 분류)

  • Baek, Dong-Hyun;Koo, Lock-Jo;Lee, Kyung-Sun;Kim, Dong-San;Shin, Min-Ju;Yoon, Wan-Chul;Jung, Myung-Chul
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.31 no.1
    • /
    • pp.41-48
    • /
    • 2008
  • Enhanced machine reliability has dramatically reduced the rate and number of railway accidents but for further reduction human error should be considered together that accounts for about 20% of the accidents. Therefore, the objective of this study was to suggest a new taxonomy of performance shaping factors (PSFs) that could be utilized to identify the causes of a human error associated with railway accidents. Four categories of human factor, task factor, environment factor, and organization factor and 14 sub-categories of physical state, psychological state, knowledge/experience/ability, information/communication, regulation/procedure, specific character of task, infrastructure, device/MMI, working environment, external environment, education, direction/management, system/atmosphere, and welfare/opportunity along with 131 specific factors was suggested by carefully reviewing 8 representative published taxonomy of Casualty Analysis Methodology for Maritime Operations (CASMET), Cognitive Reliability and Error Analysis Method (CREAM), Human Factors Analysis and Classification System (HFACS), Integrated Safety Investigation Methodology (ISIM), Korea-Human Performance Enhancement System (K-HPES), Rail safety and Standards Board (RSSB), $TapRoot^{(R)}$, and Technique for Retrospective and Predictive Analysis of Cognitive Errors (TRACEr). Then these were applied to the case of the railway accident occurred between Komo and Kyungsan stations in 2003 for verification. Both cause decision chart and why-because tree were developed and modified to aid the analyst to find causal factors from the suggested taxonomy. The taxonomy was well suited so that eight causes were found to explain the driver's error in the accident. The taxonomy of PSFs suggested in this study could cover from latent factors to direct causes of human errors related with railway accidents with systematic categorization.

Stabilization Performance Evaluation of Filter(pH) Using Ionic Water Generator (이온수기 필터(pH)의 안정화 성능평가)

  • Nam, Sangyep;Kwon, Yunjung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.199-205
    • /
    • 2015
  • This study is about ionic water generator filter Recently, a lot of people feel deep interest in health and drinking water. And there are various types of water. Ionic water generator is a system with special function, and can be classified as a medical device and should be manufactured after approval from the Food and Drug Administration. Basically ionized water is different from the packaged and stored water. When the tap water or ground water passes through the various filters of ionic water generator, it turns to the purified water of pH7 ~ 7.5 and we can electrolyze that water into anion and cation by diaphragm. And in negative electrode side, we can get alkaline water with calcium ($Ca^+$), potassium ($K^+$), magnesium ($Mg^+$), sodium ($Na^+$) for body. In general, we can change pH value from 5 to 9 of ionizer by controlling the level of electrolysis voltage in the ionizer. In general, 1stage (pH8), 2stage (pH8.5), 3stage (pH9), 4stage (pH9.5) are used as the alkaline ionized water, -1Stage (pH6.0), -2 stage (pH5.0) are used as the acidic water. But in early stage, the water that passed through filter was weakly alkaline water and that was problem. Therefore, when filter condition is stable, the pH and ORP value of water is different with the early one. the initial setting pH value of the ionizer was confirmed that changes significantly. In order to resolve this problem we need to wash filter for some period time and neutralize by acidification treatment of the filter.

The Performance of Pollutant Removal Using Nonpoint Treatment Filtration Device and Analysis of the Filter Backwashing Effect (여과형 비점오염 처리장치의 오염물질 제거특성 및 역세척 분석)

  • Lee, Jun-ho;Yang, Seung-ho;Bang, Ki-woong
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.5
    • /
    • pp.523-532
    • /
    • 2015
  • Hydrocyclone is widely used in industry, for its simple design, high capacity, low maintenance and low operational cost. The objective of this study is to develop hydrocyclone coagulation and filtration system. The system is made of hydrocyclone ballasted coagulation with polyaluminium chloride silicate (PACS) and upflow filter to treat micro particles in urban storm runoff. Roadside sediment particles (< $200{\mu}m$) was mixed with tap water to make various turbid suspensions to simulate urban storm runoff. The filter cartridge was filled with polyethylene media system and ran 1hr per everyday and total operation time were 8.19hrs and backwashing everyday after end of operation. The operation condition of flowrate was $8.2{\sim}11.9m^3/day$ (mean $10.1m^3/day$) and surface overflow rate (SOR) based on filter surface area was $45.5{\sim}65.9m^3/m^2/day$ (mean $55.7m^3/m^2/day$). The range of PACS dosage concentration was 14.0~31.5 mg/L. As the results of operation, the range of removal efficiency of turbidity, SS were 81.0~95.8% (mean 89.5%) 81.8~99.0% (mean 91.4%), respectively. An increase of filtration basin retention time brought on increased of removal efficiency of turbidity and SS, and increase of SOR brought on decreased of removal efficiency. During the first flush in urban area, storm runoff have an high concentration of SS (200~600 mg/L) and the filtration bed becomes clogged and decreased of removal efficiency. Backwashing begins when the drainage pipe valve at the filtration tank bottom is completely open (backwashing stage 1). Backwashing stage 2 was using air bubbles and water jet washing the media for 5 mins and open the drainage valve. After backwashing stage 1, 2, 61.83~64.04%, 18.53~27.51% of SS loading was discharged from filtration tank, respectively. Discharged SS loading from effluent was 7.12~14.79% and the range of residual SS loading in fliter was 2.26~5.00%. The backwashing effects for turbidity, SS were 89.5%, 91.4%, respectively. The hydrocyclone coagulation and filtration with backwashing system, which came out to solve the problems of the costly exchange filter media, and low efficiency of removing micro particles of filter type nonpoint treatment devices, is considered as an alternative system.