• Title/Summary/Keyword: TAE-RA.

Search Result 734, Processing Time 0.029 seconds

Tribological Characteristics of Magnetron Sputtered MoS$_2$ films in Various Atmospheric Conditions

  • Kim, Seock-Sam;Ahn, Chan-Wook;Kim, Tae-Hyung
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.9
    • /
    • pp.1065-1071
    • /
    • 2002
  • The friction and wear behaviors of magnetron sputtered MoS$_2$ films were investigated through the use of a pin and disk type tester. The experiments were performed for two kinds of specimens (ground (Ra 0.5 $\mu\textrm{m}$) and polished (Ra 0.01 $\mu\textrm{m}$) substrates) under the following operating condifions : linear sliding velocities in the range of 22~66 mm/s (3 types), normal loads varying from 9.8~29.4 N(3 types) and atmospheric conditions of air, medium and high vacuum (3types). Silicon nitride pin was used as the lower specimen and magnetron sputtered MoS$_2$ on bearing steel disk was used as the upper specimen. The results showed that low friction property of the MoS$_2$ films could be identified in high vacuum and the specific wear rate in air was much higher than that in medium and high vacuum due to severe oxidation. It was found that the main wear mechanism in air was oxidation whereas in high vacuum accumulation of plastic flow and adhesion, were the main causes of wear.

The Characteristic Curves of Commercial Medical X-ray Films (상용 의학용 X-ray 필름의 특성곡선)

  • Heo, Hoon;Jeong, Yeon-Tae;Lee, Jae-Sung
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.19 no.2
    • /
    • pp.12-21
    • /
    • 2001
  • For the purpose of determining characteristics of widely used commercial medical x-ray films, which are used for obtaining the Linac-grams for radiational treatment of cancers, we placed several commercial x-ray films at a fixed distance form the linear accelerator. After varying the exposed amount of radiation step by step, we could obtain a continually increasing density image for each film whose densities were determined by microdensitometer readings. The characteristic curves of the films were obtained by plotting the densities vs. the exposed radiation amounts, and their ${\gamma}$ values were determined. These values can be used to suggest a minimum necessary amount of exposed radiation to get a useful Linac-gram. The measured ${\gamma}$ values of the characteristic curves of the Kodak-DVP/RA-1 film were 1.73 when used 6MV x-ray, 1.70 when used 15MV of intensity. For the Konica-AX film, ${\gamma}$ values were 1.29 and 1.18 respectively. The result suggests that the effective conditions for high resolution of a L-gram be 6 MV of x-ray intensity and about 3 rad of exposed dose on a Kodak-DVP/RA-1 film.

  • PDF

A Fundamental Study on the Comparison and Analysis of Flood Plain Maps and Numerical Simulation (침수흔적도 및 수치모형 결과의 비교.분석 기초 연구)

  • Ahn, Jae-Chan;Jung, Do-Joon;Kim, Yun-Tae;Lee, Jae-Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.362-366
    • /
    • 2010
  • 하천 설계를 위한 다양한 수치모의 프로그램을 활용하여 홍수위, 침수심, 침수면적 등을 검토 분석하여 실시설계에 반영하고 사업을 추진하고 있으나, 실제 호우사상과 수치모의 모형에 대한 결과 분석은 매우 부족한 실정이다. 본 연구에서는 경기도 양평군 흑천 하류부를 대상으로 2006년 7월 집중호우 시 침수흔적도 및 HEC-GeoRAS에 의한 침수영향 비교 검토와 함께 하천 흐름의 주요 영향계수인 조도계수를 다양화하여 침수변화 양상 등에 대해 분석하였다. 모의 결과 흑천 하류부에 대한 침수영향은 침수흔적도와 서로 상이한 결과를 나타내고, 조도계수의 증가에 따라 침수면적은 증가 양상을 보이고 있다. 상기 결과를 볼 때 침수흔적도와 HEC-GeoRAS의 침수구역 비교 검토시에서는 피해당시의 하천환경에 대한 조사 및 피해원인에 대해 정밀 검토후 다양한 사례 연구 후 적용이 필요할 것으로 판단된다. 또한 침수모의 분석이 가능한 다양한 프로그램을 적용하여 향후 실제 침수흔적을 잘 반영할 수 있는 프로그램 개발과 적용시 착안 사항 등에 대한 검토도 병행할 필요가 있는 것으로 판단된다.

  • PDF

Damage Monitoring of Concrete With Acoustic Emission Method for Nuclear Waste Storage: Effect of Temperature and Water Immersion

  • Park, June-Ho;Kwon, Tae-Hyuk;Han, Gyeol;Kim, Jin-Seop;Hong, Chang-Ho;Lee, Hang-Lo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.3
    • /
    • pp.297-306
    • /
    • 2022
  • The acoustic emission (AE) is proposed as a feasible method for the real-time monitoring of the structural damage evolution in concrete materials that are typically used in the storage of nuclear wastes. However, the characteristics of AE signals emitted from concrete structures subjected to various environmental conditions are poorly identified. Therefore, this study examines the AE characteristics of the concrete structures during uniaxial compression, where the storage temperature and immersion conditions of the concrete specimens varied from 15℃ to 75℃ and from completely dry to water-immersion, respectively. Compared with the dry specimens, the water-immersed specimens exhibited significantly reduced uniaxial compressive strengths by approximately 26%, total AE energy by approximately 90%, and max RA value by approximately 70%. As the treatment temperature increased, the strength and AE parameters, such as AE count, AE energy, and RA value, of the dry specimens increased; however, the temperature effect was only minimal for the immersed specimens. This study suggests that the AE technique can capture the mechanical damage evolution of concrete materials, but their AE characteristics can vary with respect to the storage conditions.

A Study on Mobility Support in IP-based Sensor Networks (IP 기반 센서 네트워크에서 이동성 지원에 관한 연구)

  • Jung, Sung-Min;Kim, Tae-Kyung;Chung, Tai-Myoung
    • Annual Conference of KIPS
    • /
    • 2011.04a
    • /
    • pp.736-739
    • /
    • 2011
  • IP 기반의 센서 네트워크인 6LoWPAN 은 IEEE 802.15.4 표준에 IPv6 를 적용하기 위해 제안되었다. 현재 IPv6 상에서 노드의 이동성을 지원하기 위한 기술로 MIPv6 와 PMIPv6 가 표준화 되었다. 6LoWPAN 에서 이동성을 지원하기 위해서 PMIPv6 를 적용하는 것이 MIPv6 를 적용하는 것보다 더 효율적이다. PMIPv6 기술의 특징은 기존의 MIPv6 에 비해 노드가 바인딩 메시지를 처리하지 않는 점이다. 따라서 노드의 부하를 줄일 수 있기 때문에 6LoWPAN 에 적합하다. 하지만 6LoWPAN 노드의 하드웨어적인 제약 사항을 고려해 볼 때, 기존의 PMIPv6 를 그대로 적용하기에는 무리가 있다. 그대로 적용한다면 PMIPv6 은 원 홉에 기반하고 있기 때문에 멀티 홉에 기반한 6LoWPAN 에는 적합하지 않다. 또한 기존에 정의되어 있는 RS 나 RA 메시지의 크기로 인해 멀티 홉 경로상의 각 단말에 많은 부하를 줄 수 있다. 본 논문에서는 위의 문제점을 해결하기 위해 6LoWPAN 에 적합한 RS 와 RA 메시지를 제안한다.

WiBro Network Authentication and TEK establishment using DH key distribution on PKMv2 RSA based authentication (PKMv2 RSA 기반 인증에서의 DH키 분배를 적용한 WiBro 무선네트워크의 인증 및 TEK 생성)

  • Lee, Hyoung Seob;Cho, Chi Hyun;Kim, Kyung Tae;Youn, Hee Yong
    • Annual Conference of KIPS
    • /
    • 2007.11a
    • /
    • pp.1010-1013
    • /
    • 2007
  • 와이브로 서비스는 고속 이동 인터넷 환경 속에서 고속으로 무선 인터넷 서비스를 제공하는 기술이다. 기존의 무선인터넷 서비스와 달리 이동성을 제공한다는 점에서 차별화를 제공한다. 이렇게 이동하는 단말에게 양질의 데이터를 안전하게 전송하기 위해서는 보안기술이 중요한 요소로 작용한다. 서비스를 제공하기 전에 단말(Mobile Station)과 RAS(Radio Access Stations)간의 인증을 바탕으로 상호 키(TEK:Traffic Encryption Key)를 분배하고 TEK를 바탕으로 데이터를 암호화해서 전송하게 된다. 기존의 인증 프로토콜에서는 RAS에서 단독으로 키를 생성하는 방식이지만, 본 논문에서는 기존의 프로토콜의 문제점으로 지적된 Replay Attack에 대해 DH(Diffie-Hellman) 키 분배(Key Distribution) 방식을 적용하는 프로토콜을 제안함으로써 취약점에 대비 하였다. 이를 통해 RAS에 집중되는 키 생성에 대한 오버헤드를 단말에 분산 시킬 수 있다. 이로써 제안된 프로토콜을 사용해서 기존의 프로토콜을 사용했을 때보다 보안강도를 높일 수 있다.

Antimicrobial Resistance of Vibrio Strains from Brackish Water on the Coast of Gyeongsangnamdo (경남연안 기수지역에서 분리된 비브리오균의 항균제 내성)

  • Oh, Eun-Gyoung;Son, Kwang-Tae;Ha, Kwang-Soo;Yoo, Hyun-Duk;Yu, Hong-Sik;Shin, Soon-Bum;Lee, Hee-Jung;Kim, Ji-Hoe
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.42 no.4
    • /
    • pp.335-343
    • /
    • 2009
  • Antimicrobial resistance patterns of Vibrio species isolated from brackish water in Geoje, Tongyeong and Goseong, Gyeongsangnamdo province into which streams, sewage and leachate all flowed. Only 19 strains (10.7%) of 177 V. parahaemolyticus were susceptible to 15 antimicrobials. 146 strains (69.5%) proved resistant against more than one antimicrobial and 12 strains (6.8%) were multi-drug resistant. The resistance rate of 152 strains were 85.9% against AM and 26.6% against RA, 16.4% against AN, 13.6% against Sand 13.0% against TMP. 86 strains of 129 V. cholerae non-O1 (66.7%) were susceptible to antimicrobials and 31 strains (24.0%) were resistant to more than one antimicrobial and 12 strains (9.3%) were multi-drug resistant. The antimicrobial resistance rate of 129 strains against 15 antimicrobials, with the exception of C, CIP, E and GM, i.e. 11 antimicrobials, was 0.7-16.2%, 16.2% of 129 strains proved resistant against RA and 13.9% against AM, 9.3% against TMP, 7.7% against SXT and 6.9% against TE. 19 of 49 strains of V. mimicus (38.8%) were susceptible to antimicrobials and 31 strains (61.2%) were resistant against more than one antimicrobial; none of the strains were multi-drug resistant. 15 strains of V. mimicus were resistant against only RA, AmC and TE. The resistance rate was 59.2% against RA (highest) 4.1% against AmC and 2.0% against TE.

Pulsatility Index of Blood Echogenicity of the Human Radial and Common Carotid Arteries: Relation with Age and Stroke (인체 요골동맥과 경동맥의 혈액에코박동지수: 나이 및 뇌졸중과의 관계)

  • Bok, Tae-Hoon;Kong, Qi;Nam, Kweon-Ho;Choi, Jay Chol;Paeng, Dong-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.494-501
    • /
    • 2012
  • In the present paper, the ultrasound blood images were measured at both the human radial artery(RA) and common carotid artery(CCA), depending on the age, and the pulsatility index of blood echogenicity(PIBE) was analyzed. In addition, the ultrasound blood images were measured at both RA and CCA of both the stroke patients and the control group, and PIBE was compared. PIBE of RA for the young group was similar with that for the old group ($0.13{\pm}0.11$ and $0.16{\pm}0.03$). PIBE of CCA for the young group, however, was larger than that for the old group ($0.70{\pm}0.21$ and $0.32{\pm}0.01$), and was more variable depending on the subject. Similarly, the fibrinogen concentrations of the patients ($336{\pm}61$ and $340{\pm}126mg/dl$) were more than that of the control group ($264{\pm}38$ and $257{\pm}43mg/dl$), for both RA and CCA. The results indicate the possibility of the ultrasonic test on the correlation between erythrocyte aggregation and stroke, and it is expected that the in-vivo EA measurement would be clinically useful.

Effect of Invasive Species on Reservoir Fish Communities: For Joongchosan and Bukchosan (외래종 배스가 저수지 어류군집에 미치는 영향: 중초산과 북초산 저수지를 대상으로)

  • Park, Cheol Woo;Yoo, Su-Hyang;Cho, Yun Jeong;Kim, Jong Wook;Kang, Eue tae;Kim, Jae Goo;Kim, Su Hwan
    • Korean Journal of Ecology and Environment
    • /
    • v.54 no.2
    • /
    • pp.96-101
    • /
    • 2021
  • In this study, we wanted to obtain the information of the ecological impact of alien species on native fish communities. The Ichthyofauna and fish community in Joongchosan Reservoir and Bukchosan Reservoir in Gunsan-si Korea were investigated over the period from March to October 2020. During the survey period, a total of 1,895 individuals representing eight species, five families, and four orders were caught in the Joongchosan Reservoir. In the Bukchosan Reservoir, a total of 171 individuals were caught, representing seven species, five families, and three orders. The dominant species and subdominant species of Joongchosan Reservoir were Pseudorasvora parva (661 individuals, RA: 34.7%), and Rhodeus ocellatus (660 individuals, RA: 34.7%). Conversely, Micropterus salmoides (77 individuals, RA: 45.0%), and Carassius auratus (60 individuals, RA: 35.1%), were the two most common species in the Bukchosan Reservoir. The community indices showed a dominance of 0.697, diversity of 1.483, evenness of 0.713, and species richness of 0.928 in the Joongchosan Reservoir. In comparison, the community indices in the Bukchosan Reservoir showed a dominance of 0.801, diversity of 1.304, evenness of 0.670, and species richness of 1.167. This study confirms that the number of native fishes and the associated community diversity have decreased due to the influence of Micropterus salmoides. This highlights the need for removal of alien species from reservoirs, while simultaneously preventing future introductions.

Feasibility and Safety of a Technique Intended to Place the Catheter Tip in the Right Atrium without Abutment Against the Cardiac Wall during Implantation of the Totally Implantable Venous Access Port (완전이식형 정맥 접근 포트 삽입 시 카테터 팁을 심벽에 닿지 않고 우심방 내 위치시키는 방법의 타당성과 안전성)

  • Hyejin Park;Tae-Seok Seo;Myung Gyu Song;Woo Jin Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.161-170
    • /
    • 2024
  • Purpose To assess the safety and feasibility of intentionally positioning the catheter tip in the right atrium (RA) without an abutment during implantation of a totally implantable venous access port (TIVAP). Materials and Methods We enrolled 330 patients who had undergone TIVAP implantation between January and December 2016 and postoperative chest CT. The TIVAP was placed using the single-incision technique to access the axillary vein directly from the incision line. To position the catheter tip in the RA without abutment, blood return was checked before cutting. Catheter length and complications were evaluated by retrospectively reviewing medical images and records. Results All patients achieved successful catheter tip positioning without abutment or dysfunction. The median tip position was 15.3 mm distal to the cavoatrial junction (CAJ) on fluoroscopy and 6 mm distal to the CAJ on CT. Catheter tips migrated a median of 10.4 mm cephalically on CT compared to fluoroscopy. Thromboses were detected in the RA and superior vena cava in one patient each. Conclusion Intentional catheter tip positioning in the RA without abutment is a safe and feasible technique with a low incidence of thrombosis and no observed dysfunction.