Purpose : To retrospectively evaluate the usefulness of diffusion-weighted images, ADC maps and conventional MR images for determination of brain tumor consistency. Materials and Methods : Twenty-three patients with brain tumor underwent MR examinations with T1, T2 and diffusion-weighted images. Regions of interest (ROIs) were drawn in the tumors, and the measured signal intensities (SI) were normalized with the contralateral side. We evaluated the correlation between SI ratios from various images and tumor consistency assessed at surgery. In three patients with both cystic and solid components, each component was evaluated independently. Qualitatively observed SIs were also correlated with tumor consistency. Results : Statistical analysis revealed significant correlation between tumor consistency and ADC ratio (r = -0.586, p = 0.002), SI ratios on T2-weighted images (r = -0.497, p = 0.010), and observed SIs on T2-weighted images (r = -0.461, p = 0.018). The relative ratio of ADC value correlated with tumor consistency most strongly. Conclusion : The measured ratio of ADC, SI ratio and observed SI grade on T2-weighted images can provide valuable information about the consistency of brain tumor.
A 12-year-old, intact, female Alaskan malamute presented with severe spinal pain and hind limb lameness. On radiographs, a round, demarcated lytic lesion was identified in the central fifth lumbar vertebra. On magnetic resonance imaging (MRI), the lesion involving the spinal cord appeared hypointense on T1 weighted, hyperintense on T2 weighted, heterogeneously enhanced on post-contrast T1 weighted, and hypointense on GE images. A focal, small, ill-defined, lytic lesion was also observed radiographically in the sixth lumbar vertebra, it appeared as a focal hyperintense lesion on T1 weighted, T2 weighted, and GE images and showed focal enhancement on post-contrast T1 weighted images. She was euthanized owing to extreme pain and severe and progressive clinical signs; a plasmacytoma was histopthologically diagnosed. This report presents an unusual type of spinal tumor, plasmacytoma. MRI is a useful modality to evaluate the anatomic location and extension of spinal lesions.
In the present study, changes in signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) of the diffusion-weighted images in the normal livers were investigated using changes in b values in 1.5 T MR (magnetic resonance) instruments. Respective diffusion-weighted images and ADC map images were obtained from 20 healthy individuals by increasing b values from 50 to 400 and 800 $s/mm^2$ using 1.5T MR scanner between January 2011 and November 2011. At each ADC map image obtained at each b value, ADCs in the right hepatic lobe, spleen and kidney were measured. As a result, ADCs of the right hepatic lobe, spleen and kidney have gradually decreased in the diffusion-weighted images in accordance with the reduced b value. This outcome may be used as preliminary data for applications to various abdominal diseases.
Currently, there has been an increase in the use of surgical modalities to treat lymphedema and MR imaging to examine lymphatic vessels. Furthermore, there have been several advancements in the field of MR imaging, from the traditional heavily T2-weighted images to three-dimensional images. Three-dimensional images include spoiled gradient echo images, and numerous advanced techniques have been implemented. Among the fat suppression techniques, mDixon technique has recently been in the spotlight.
Yul Lee;Kwan Seop Lee;Dae Hyun Hwang;In Jae Lee;Hyun Beom Kim;Jae Young Lee
Korean Journal of Radiology
/
v.2
no.3
/
pp.171-174
/
2001
Shaken baby syndrome (SBS) is a form of child abuse that can cause significant head injuries, of which subdural hematoma (SDH) is the most common manifestation. We report the MRI findings of chronic SDH in three cases of SBS, involving two-, three- and eight-month-old babies. The SDH signal was mostly low on T1-weighted images and high on T2-weighted images, suggesting chronic SDH. In chronic SDH, a focal high signal on T1-weighted images was also noted, suggesting rebleeding. Contrast-enhanced MRI revealed diffuse dural enhancement.
Park, Jun-Woo;Kim, Hak-Jin;Song, Geun-Sung;Han, Hyung-Soo
Journal of Korean Neurosurgical Society
/
v.47
no.3
/
pp.203-209
/
2010
Objective : The purpose of study was to evaluate the feasibility of brain magnetic resonance (MR) images of the rat obtained using a 1.5T MR machine in several blood-brain barrier (BBB) experiments. Methods : Male Sprague-Dawley rats were used. MR images were obtained using a clinical 1.5T MR machine. A microcatheter was introduced via the femoral artery to the carotid artery. Normal saline (group 1, n = 4), clotted autologous blood (group 2, n = 4), triolein emulsion (group 3, n = 4), and oleic acid emulsion (group 4, n = 4) were infused into the carotid artery through a microcatheter. Conventional and diffusion-weighted images, the apparent coefficient map, perfusion-weighted images, and contrast-enhanced MR images were obtained. Brain tissue was obtained and triphenyltetrazolium chloride (TTC) staining was performed in group 2. Fluorescein isothiocyanate (FITC)-labeled dextran images and endothelial barrier antigen (EBA) studies were performed in group 4. Results : The MR images in group 1 were of good quality. The MR images in group 2 revealed typical findings of acute cerebral infarction. Perfusion defects were noted on the perfusion-weighted images. The MR images in group 3 showed vasogenic edema and contrast enhancement, representing vascular damage. The rats in group 4 had vasogenic edema on the MR images and leakage of dextran on the FITC-labeled dextran image, representing increased vascular permeability. The immune reaction was decreased on the EBA study. Conclusion : Clinical 1.5T MR images using a rat depicted many informative results in the present study. These results can be used in further researches of the BBB using combined clinical MR machines and immunohistochemical examinations.
Purpose : To evaluate the detection rate of hyperacute intracerebral hemorrhage in echo planar imaging (EPI) and other MR sequences. materials and Methods : Intracerebral hemorrhage was experimentally induced in ten rats. EPI, fast spin-echo (FSE) T2 weighted images, fluid attenuated inversion recovery (FLAIR), spin-echo (SE) T1 weighted images and gradient echo (GE) T1 weight ed images of rat's brains were obtained 2 hours after onset of intracerebral hemorrhage. EPI and FSE T2 images were additionally obtained 30 min and 1 hour after onset of hemorrhage in 3 and 6 rat, repeatedly, For objective visual assessment, discrimination between the lesion and normal brain parenchyma was evaluated on various MR sequences by three radiologists. For quantitative assessment, contrast-to-noise ratio (CNR) was calculated fro hemorrhage-normal brain parenchyma. Statistical analysis was performed usning the Wilcoxon-Ranks test. Results : EPI, FLAIR, and FSE T2 images showed high signal intensity lesions. The lesion discrimination was easier on EPI than on other sequences, and also EPI showed higher signal intensity for the subjective visual assessment. In quantitative evaluation, CNR of the hemorrhagic lesion versus normal brain parenchyma were higher on EPI and FLAIR images (p<0.01). There was no difference in CNR between EPI and FLAIR (p>0.10). On MR images obtained 30 minutes and 1 hour after the onset of intracerebral hemorrhage, the lesion detection was feasible on both EPI and FSE T2 images showing high signal intensity. Conclusion : EPI showed higher detection rate as compared with other MR sequences and could be useful in early detection and evaluation of intracerebral hemorrhage.
Purpose: To assess the usefulness of breath-hold fast MR imaging of liver with fat suppression (FS) by application of chemical saturation technique in the diagnosis of regional fatty changes suspected in sonography. Materials and Methods: Thirteen patients who had focal lesions with diffuse, homogeneous signal changes after FS through chemical saturation technique without additional changes of imaging parameter during MR imaging of liver were selected. T1-weighted fast low-angle shot and T2-weighted turbo spin-echo sequences were obtained with or without FS during each single breath-holding session. Subjective changes of signal intensity between the pre-FS and the FS images were compared with the sonographic findings in each lesion. Results: Seven lesions of decreased signal intensity after FS on T1 or T2-weighted images, including three lesions only at FS T1 images, were regarded as focal fat infiltration. All seven lesions had compatible sonographic findings as homogenously echogenic areas. Another six lesions of subjectively increased signal intensity including two lesions only at FS T2 images were regarded as focal fat sparing. All six lesions had sonographic findings as homogenous echo poor areas suggesting focal fat sparing. In cases regarded as fat infiltration, score changes were more prominent at FS T1 images than FS T2 images(p=0.0002). In cases regarded as fat sparing, score changes were more prominent at FS T2 images than FS T1 images(p=0.042). Conclusion: Breath-hold fast T1 and T2-weighted MR imaging with and without chemical saturation pre-pulse may be sufficient for characterization of regional fatty changes in the differential diagnosis of focal hepatic lesion found at sonography.
Purpose : To evaluate the usefulness of comparison of the signal intensity of uterine septum in the differential diagnosis of bicornuate and septate uterus on magnetic resonance (MR) imaging. Materials and methods : Preoperative MR imaging findings of surgically proven 5 bicornuate and 6 septate uteri were retrospectively analyzed. Because preoperative differential diagnosis of both was possible in all cases in terms of the intercornual distance, external contour of uterine fungus, and divergent angle of two uterine cavities, these criteria were excluded in this study. The signal intensity of uterine septum in patients with bicornuate and septate uterus was analyzed on T1-weighted and fast spin echo T2-weighted images obtained in the axial and coronal planes, using a 1.5-T MR scanner. The signal intensity of uterine septum especially on T2-weighted images was compared with that of myometrium or junctional zone. Results : The signal intensity of uterine septum in patients with bicornuate uterus (n=5) and septate uterus (n=6) was similar to that of myometrium in all cases on T1-weighted images. The septum of bicornuate uterus (n=5) on fast spin echo T2-weighted images was isointense with myometrium in three and hypointense in two cases. The uterine septum of septate uterus (n=6) on T2-weighted images was isointense with myometrium in two, hypointense in two, and isointense with or more hypointense than junctional zone in two cases. No patient showed different signal intensity between upper and lower uterine septum. Conclusion : Because the MR signal intensity of the uterine septum in bicornuate or septate uterus is variable, it should not be used alone in the differential diagnosis of them. In these clinically important differentiation, therefore, comprehensive analysis of MR findings in terms of the external contour of uterine fundus, intercornual distance, divergent angle of two uterine cavities, in addition to the signal intensity of the uterine septum, should be considered.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.