Purpose : This study was performed to evaluate the characteristics of rat mesenchymal stem cells (RMSCs) transduced with human ferritin gene and investigate
Endothelial release of nitric oxide (NO) contributes to the regulation of vascular tone by inducing vascular relaxation. To estimate the blood flow-dependent nitric oxide level and half-life (T1/2) of nitric oxide in vivo state, we investigated the change of aortic NO currents during the change of aortic blood flow rate using NO-selective electrode system and electromagnetic flowmeter in the aorta of anesthetized rats. Resting mean aortic blood flow rate was
This paper is concerned with the strain characteristics of the time effect on the remoulded saturated day sampled from the downstream of the Yeongsan river, and the constitutive equation that can generally explain time-dependent behaviors of norma1ly consolidated clay. This paper examines whether or not the afore-said constitutive equation can be applied to the remoulded Mooan-clay. Throughout this study, the conclusions obtained are as follows. 1. Throughout the isotropic consolidation test for 7 days and the isotropic relaxation test, the existence of the static and dynamic yielding surfaces is confirmed respectively. 2. The characteristics of time effect of the deformation, namely, the existence of a unique stress-strain-time relation, is conformed from the experimental result on the Mooan-clay. 3. The prodictions of the stress path and the strain on the Cam-clay theory is not consistent with those observed during the experiments. 4. Constitutive equation(2-3-12) obtained by applying Cam-clay theory to Perzyna's elastic-viscoplasticity theory can explain the behavior of pore water pressure during isotropic stress relaxation, concerned with time dependency under undrained condition. The equation can also explain the results of the undrained triaxial compression test for the clay with different strain rate under the same or different consolidation history. 5. This constitutive equation has eight material parameters which can be determined from triaxial compression tests.
[
This study was designed and carried out to investigate the effect of Assertiveness Training on the stress response and assertive behavior of emergency room nurses from September 22, to December 21. 1997. The subjects were 45 emergency room nurses of three general hospitals of Korea University Medical Center; 25 assigned for the experimental and 20 for the control group. The Assertive Training Program was composed of cognitive training, behavioral training and progressive muscle relaxation. The subjects of the experimental group carried out the 15-minute progressive muscle relaxation according to recorded-tape once a day for 6 weeks. The cognitive and the behavioural training were conducted by the investigator for 5-8 subjects at a time for 9 series, at an interval of 4-5 days. Post-measurement were administered to all sujects in two groups three weeks after the last session. The level of general stress (Cline, 1992), job stress (Kim & Koo, 1984), physiological response to stress (cortisol, epinephrine, norepinephrine), symptoms of stress (Lee, 1984) and assertive behavior (Kim, 1982) were measured before the first and after the last experiments. Data were analysed by x2, t, paired t, Wilcoxon signed rank tests Wilcoxon rank sums tests. The results are as follows : 1. The level of general stress of the experimental group was lower than that of the control group, however, no significant difference between the two groups (P=0.234) was revealed. 2. A significant reduction of job stress was revealed in the experimental group (P=0.017). 1) A significant reduction of interpersonal conflicts in the experimental group was revealed (P=0.018). 3. The physiological stress-response were analyzed as follows : 1) A decrease of Cortisol in both the experimental and the control groups was noticed, however, the difference between the two groups was not statistically significant (P=0.991). Pre-and post-measurement of the level of Corti sol revealed that a notable decrease in the experimental group and an increase in the control group with no significant difference in the day-day subjects (P=0.765), a significant decrease was noted on the level of Cortisol of the experimental group in the night-night nurses (P=0.036). 2) An increase of Epinephrine in both groups was noticed, however, a difference was not statistically significant between the two groups (P=0.082). Pre-and post-measurement of the level of Epinephrine revealed that a notable decrease in the experimental group and an increase in the control group with no significant difference in the day-day subjects (P=0.136). increases were noted on the level of Epinephrinel of both groups in the night-night nurses (P=0.136), 3) The level of Norepinephrine of the experimental group was significantly decreased (P=0.020). Pre-and post-measurement of the level of Norepinephrine revealed that a notable decrease in the experimental group and an increase in the control group with no significant difference in the day-day subjects (P=0.073). a significant decrease was noted on the level of Norepinephrine of the experimental group in the night-night nurses (P=0.036), 4. Symptoms of stress were reduced in both groups, with no significant differences between the groups (P=0.127). 1) The physical stress symptoms were reduced in both groups, with no significant difference (P=0.386), 2) The cognitive-behavioral stress symptoms were significantly reduced in the experimental group (P=0.037). 3) The emotional stress symptoms were reduced in both groups with no significant difference between the groups (P=0.110). 5. The assertive behavior was significantly increased in the experimental group (P=0.000). This study signified the Assertiveness Training as an effective mean of self intervention for the reduction of stress of nurses assigned to emergency rooms.
Manganese is an essential element in the body. It is mainly deposited in the liver and to a lesser degree in the basal ganglia of the brain and eliminated through the bile duct. Rapid turnover of managanese in the body makes it difficult to evaluate the manganese exposure in workers, esecially in those with irregular or intermittent exposure, like welders. Therefore, conventional biomarkers, including blood and urine manganese can provide only a limited information about the long-tern or cumulative exposure to manganese. Introduction of magnetic resonance imaging (MRI) made a progress in the assessment of manganese exposure in the medical conditions related to manganese accumulation, e. g. hepatic failure and long-term total parenteral nutrition. Manganese shortens spin-lattice(T1) relaxation time on MRI due to its paramagnetic property, resulting in high signal intensity (HSI) on T1-weighted image(T1W1) of MRI. Manganese deposition in the brain, therefore, can be visualizedas an HSI in the globus pallidus, the substantia nigra, the putamen and the pituitary. clinical and epidemiologic studies regarding the MRI findings in the cases of occupational and non-occupational manganese exposure were reviewed. relationships between HSI on T1W1 of MRI and age, gender, occupational manganese exposure, and neurological dysfunction were analysed. Relationships betwen biological exposure indices and HSI on MRE werealso reviewed. Literatures were reviewed to establish the relationships between HSI, Manganese deposition in the brain, pathologic findings, and neurological dysfunction. HSI on T1W1 of MRI reflects regional manganese deposition in the brain. This relationship enables an estimation of regional manganese deposition in the brain by analysing MR signal intensity. Manganese deposition in the brain can induce a neuronal loss in the basal ganglia but functional abnormality is supposed to be related to the cumulative exposure of manganese in the brain, use of brain MRI for the assessment of exposure in a group of workers seems to be hardly rationalized, while ti can be a useful adjunct for the evaluation of manganese exposure int he cases with suspected manganese-related health problems.
This study was designed to investigate the effect of one-to-one labor support on labor pain, labor stress response, childbirth experience and neonatal status for primipara by a quasi experiment (nonequivalent control group pretest-posttest design), from April 30, 1999 to February 20, 2000. The subjects of this experiment consisted of eighty two primipara with single gestation, full term, uncomplicated pregnancies. Forty one were in the experimental group and forty one in the control group. Their mean age was 25.95 years, their mean gestation period was 39.9 weeks. A caring package of one-to-one labor support had three components. Physical support consisted of massage, back pressure, touch. Emotional support was provided by a continuous nurse's presence, acceptance and encouragement. Informational support involved teaching breathing skills, relaxation skills and knowledge about the labor process. Data assessed labor pain, pulse rate and blood pressure to measure labor stress response. Also, in measuring the value of labor stress response, plasma epinephrine, plasma norepinephrine and serum cortisol were measured. In the 24 hours after birth, the data for the postpartum mother's childbirth experiences was collected. Umbilical cord arterial blood pH, one minute and five minute Apgar score were measured after birth. Data was analyzed by t-test,
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70