• Title/Summary/Keyword: T2 Measurement

Search Result 2,013, Processing Time 0.035 seconds

Design of 24GHz Patch Array Antenna for Detecting Obstacles (장애물 감지용 24GHz 대역 패치 배열 안테나 설계)

  • Lee, Kwang;Kim, Young-Su
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1075-1080
    • /
    • 2021
  • In this paper, we designed a 24.4GHz 2-channel TX and 4-channel RX patch array antenna mounted on a short-range vehicle radar system to simultaneously measure the range and speed of a single object within a single measurement cycle. The antenna was designed and fabricated using Rogers' RO4350B(εr=3.48, 0.5T) board. Through measurement, it was confirmed that the design specifications of antenna gain (> 10dBi or more) and radiation pattern (Elevation HPBW > 10deg.) were satisfied at 24.4 GHz frequency.

A Study on Self-Esteem and Urinary Symptoms in Women with Urinary Incontinence (요실금환자의 골반근육운동에 따른 자아존중감과 배뇨증상에 관한 연구)

  • Lee Young-Hee;Kim Sun-Are
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.9 no.3
    • /
    • pp.360-369
    • /
    • 2002
  • Purpose: The purpose of this study was to help enhance the quality of life for women with urinary incontinence. Self-esteem, urinary symptoms, peak pressure and duration in seconds for vaginal contraction after pelvic muscles exercise were examined. Method: One-group pretest-posttest design was employed participants were 27 married women from G city. The instrument for this study were : the self-esteem scale developed by Rosenberg(1965). the Urinary Symptom Questionnaire, a subjective measurement of urinary incontinence, developed by Jackson et al.(1996) and the Perineometer used as an objective measurement of peak pressure and duration in seconds. Result: 1. Self-esteem showed significant improvement after the exercise (t=-3.832, p= .001). 2. Comparison of results before the pelvic muscles exercise and after showed that there was a statistically significant difference for several urinary symptoms including enuresis (t=2.833, p=.009), frequency of incontinence (t=2.964, p= .006), incontinence volume (t=2.280, p= .031), incontinence before getting to the restroom (t=3.035, p= .006), incontinence with no reason or feeling (t= 3.051, p= 005) burning sensation (t= 2.132, p=.043), and a sense of residual urine (t=2.267 p=.032). The mean scores showed improvement in the urinary symptoms of management of incontinence (M=$0.04{\pm}0.22$), daily frequency of incontinence management (M=$0.13{\pm}0.85$), urinary control (M=$0.15{\pm}0.86$), running to the restroom (M=$0.15{\pm}0.60$) incontinence caused by coughing or physical activities (M=$0.19{\pm}0.57$) and hesitancy (M=$0.07{\pm}0.55$). Overall urinary symptoms decreased significantly (t =3.073. p= .007). 3. Peak pressure showed an increase from a mean of $24.26{\pm}16.20mmHg$ before the exercise to a mean of $28.63{\pm} 17.79mmHg$ after (t=-2.399, p=.024). Duration in seconds also increased from a mean of $6.00{\pm}4.95sec$ to $9.15{\pm}5.83sec$ (t=-4.400, p= 000). Conclusion: These findings suggest that pelvic muscle exercise serves to decrease urinary problems, improve self-esteem and increase peak pressure and duration in seconds.

  • PDF

Thyroid Function Test in Thyroid Diseases and Pregnancy - The diagnostic value of free thyroxine by RIA - (임신 및 각종 갑상선질환에서 갑상선 기능 판정에 관한 연구 - 혈청유리 $T_4$의 진단적 의의에 관한 고찰 -)

  • Yoo, M.H.;Yoon, H.J.;Shin, Y.T.;Lee, J.C.;Chung, S.I.;Cho, B.Y.;Lee, M.;Lee, M.C.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.15 no.1
    • /
    • pp.1-11
    • /
    • 1981
  • To evaluate the diagnostic accuracy of the measurement of free thyroxine (FT4) by radioimmunoassay, we measured free $T_4\;and\;T_4,\;T_3,\;T_3RU$, TSH and TBG serum levels by radioimmunoassay in 18 healthy persons and 52 patients with various thyroid diseases and 11 normal pregnant women. The results are as follows. 1. In 19 cases of overt hyperthyroidism, $T_3,\;free\;T_4$ and FTI, $T_4/TBG$ ratio reflect hyperfunction in all cases. $T_4$ is increased in 94% (18/19) and TBG and TSH are decreased in 79% (15/19). 2. In 8 patients with overt hypothyroidism, TSH is increased in all cases and free $T_4$ and FTI is decreased in all cases. $T_4$ is decreased in 87.5% (7/8), $T_3$ is decreased in 75% (6/8) and $T_4/TBG$ ratio is decreased in 62.5% (5/8). 3. In 5 patients who are clinically in euthyroid state after treatment of hyperthyroidism, $T_4,\;free\;T_4$, FTI and TSH are in the normal range in all cases and $T_3$ is normal in 60% (3/5) and slightly increased in 40% (2/5). 4. In 10 patients who showed clinically borderline hypothyroidism after treatment of hyperthyroidism, TSH is increased in all cases and free $T_4$ and FTI are decreased in all cases, but $T_4\;and\;T_3,\;T_4/TBG$ ratio are in the normal limit in all cases. So after treatment of hyperthyroidism, TSH, free $T_4$ or FTI are recommended as optimal thyroid function test. 5. In normal pregnancy, free $T_4$, FTI and $T_4/TBG$ ratio reflect normal function, but the other parameters revealed unreliable due to the influence of increased TBG. Also TBG and TSH level in pregnancy is increased significantly compared with normal healthy control group. 6. The coefficients of correlation between free $T_4$ and FTI were 0.862 (p<0.001) and 0.685 (p<0.001) between free $T_4\;and\;T_4/TBG$ ratio. In most patients, diagnostic value of free $T_4$ was comparable and even superior to FTI, so free $T_4$ measurement can be used routinely with thyrotropin assay in the diagnosis of hypothyrodism or with $T_3$ for the diagnosis of hyperthyroidism.

  • PDF

칼만필터를 이용한 3점식 정도측정에 관한 연구

  • Lee, Yeong-Jin;Joun, Seung-Yun;Jung, Keum-Young;Kim, Jong-Hwa;Bae, Jong-Il;Lee, Man-Hyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.72-78
    • /
    • 2001
  • Roundness measurement method using three displacement sensors makes in-process roundness measurement possible on the NC machine because it eliminates the vibration signal and eccentricity signal from measured roundness signal from the workpiece. But there are noises in measured signals, it isn't possible to measure the roundness with high precision. In this study, a high precision in-process roundness measurement system is development, which can eliminate vibrations of the spindle by using three displacement sensors and which can also estimate the noisy roundness measurement signals by applying Kalman filter.

  • PDF

The Effects of Dynamic Assessment in Terms of Scaffolding Group Types and Young Children's Measurement Ability Levels (스캐폴딩 집단유형 및 능력수준에 따른 역동적 평가과정이 유아의 측정능력에 미치는 영향)

  • Ko, Eun-Mi;Nam, Mi-Kyoung;Hwang, Hae-Ik
    • Korean Journal of Child Studies
    • /
    • v.30 no.5
    • /
    • pp.225-243
    • /
    • 2009
  • This study analyzed the effects of dynamic assessment in terms of scaffolding group types and young children's measurement ability levels. Participants were five-year-old children in Busan divided into 2 experimental groups and control groups. The Assessment Tools for Young Children's Measurement Ability (Ko & Hwang, 2008) consisted of 4 sub tests for ‘length', 'width', and 'weight' concepts. Data were analyzed by t-test and ANOVA. Results showed significant differences between experimental and control groups in post-test scores, but no significant differences between individual and peer collaboration groups in amount of scaffolding. Significant improvements showed in all of the measurement ability level groups : individual higher, individual lower, peer collaboration higher and peer collaboration lower level scaffolding groups.

  • PDF

Design and Implementation of Hadoop-based Big-data processing Platform for IoT Environment (사물인터넷 환경을 위한 하둡 기반 빅데이터 처리 플랫폼 설계 및 구현)

  • Heo, Seok-Yeol;Lee, Ho-Young;Lee, Wan-Jik
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.2
    • /
    • pp.194-202
    • /
    • 2019
  • In the information society represented by the Fourth Industrial Revolution, various types of data and information that are difficult to see are produced, processed, and processed and circulated to enhance the value of existing goods. The IoT(Internet of Things) paradigm will change the appearance of individual life, industry, disaster, safety and public service fields. In order to implement the IoT paradigm, several elements of technology are required. It is necessary that these various elements are efficiently connected to constitute one system as a whole. It is also necessary to collect, provide, transmit, store and analyze IoT data for implementation of IoT platform. We designed and implemented a big data processing IoT platform for IoT service implementation. Proposed platform system is consist of IoT sensing/control device, IoT message protocol, unstructured data server and big data analysis components. For platform testing, fixed IoT devices were implemented as solar power generation modules and mobile IoT devices as modules for table tennis stroke data measurement. The transmission part uses the HTTP and the CoAP, which are based on the Internet. The data server is composed of Hadoop and the big data is analyzed using R. Through the emprical test using fixed and mobile IoT devices we confirmed that proposed IoT platform system normally process and operate big data.

The Clinical Significance of Serum Triiodothyronine Measured by Radioimmunoassay in Various Thyroid Diseases (각종(各種) 갑상선질환(甲狀腺疾患)에서의 혈중(血中) $T_3$방사면역측정(放射免疫測定)의 진단적(診斷的) 의의(意義))

  • Lee, Hyon-U;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.9 no.1
    • /
    • pp.31-43
    • /
    • 1975
  • In an attempt to establish the diagnostic value of serum triiodothyronine and to correlate it with pathophysiologic mechanisms of thyroid hormones in various thyroid disorders, the author measured the serum triiodothyronine levels by means of radioimmunoassay and compared them with other thyroid function tests. This study was carried out in 152 cases with various thyroid functions; 28 cases as control, 51 cases of hyperthyroidism, 50 cases of euthyroidism and 23 cases of hypothyroidism. The results obtained were as follows: 1. The serum $T_3$ level in normal control group ranged between $131{\pm}34ng/dl$. 2. The serum $T_3$ levels ranged between $306{\pm}97ng/dl$ in hyperthyroidism $138{\pm}32ng/dl$ in euthyroidism and $60{\pm}27ng/dl$ in hypothyroidism. The significant differences between these groups were noted in this study. 3. In 5(9.9%) out of 51 cases with hyperthyoidism and 9(39.1%) of 23 cases with hypothyroidism, the serum $T_3$ were measured to be in normal range. Accordingly, the diagnostic value of the measurement of serum $T_3$ with hyperthyroidism was justifiable, but with hypothyroidism, it was less creditable than that of serum thyrotropin. 4. There was little significant difference between the diagnostic value of serum thyroxine and triiodthyronine levels in various thyroid disorders. However, $T_4/T_3$ ratio was decreased in patients with untreated hyperthyroidism because of more elevation of $T_3\;than\;T_4$. Consequently, the serum $T_3$ was more sensitive than $T_3$ in some thyroid disorders. 5. The serum $T_3$ level was much more sensitive and showed prompt shift in its level during the course of treatment on the patient with various thyroid disorders. And the measurement of serum $T_3$ was a good index for the evaluation of the thyroid function. From these results obtained, the measurement of serum $T_3$ by means of radioimmunoassay is a good way to understand the status of thyroid function with various thyroid disorders and evaluate the effects of the treatment given on these patients.

  • PDF

The Effect of Integrated Nursing using Cognicise and Neurofeedback (인지체조-뉴로피드백을 활용한 통합 간호의 효과)

  • Weon, Hee Wook;Heo, Gye Young;Kim, Jun Beom;Shin, Ji Eun;Lee, Won Woo;Son, Hae Kyoung
    • Korean Journal of Occupational Health Nursing
    • /
    • v.29 no.2
    • /
    • pp.114-122
    • /
    • 2020
  • Purpose: This study aimed to identify the effect of integrated nursing using cognicise and neurofeedback on cognition and α waves among elderly individuals. Methods: This quasi-experimental single group pretest-posttest study included 29 Korean adults aged 65 years or older who participated at a senior welfare center in Y city from February to May 2019. Each integrated nursing session consisted of cognicise (10 minutes) and neurofeedback (20 minutes). Subjects participated twice a week for 10 weeks. Structured questionnaires to assess participants' general characteristics and the Korean version of the Mini-Mental Status Examination for Dementia Screening (K-MMSE-DS) were applied. Alpha waves were measured using BrainMaster. Results: Following the integrated nursing program, alpha waves improved in F3 (t=2.41, p=.023), C3 (t=3.00, p=.006), C4 (t=2.60, p=.015), P3 (t=2.43, p=.022), O1 (t=2.30, p=.029), T3 (t=3.05, p=.005), T4 (t=2.28, p=.030), T5 (t=2.91, p=.007), Fz (t=2.30, p=.029), Cz (t=2.73, p=.011), and Pz (t=2.23, p=.034). Most subjects experienced improvement in concentration after participating in the intervention. Conclusion: This study provides evidence for the use of a neuroscientific approach including brain wave measurement to improve cognitive health among community-living elderly people.

150 nm Pitch Measurement using Metrological AFM (길이 소급성을 갖는 AFM을 이용한 150nm 피치 측정)

  • ;I. Misumi;S. Gonda;T. Kurosawa
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.264-267
    • /
    • 2003
  • Pitch measurements of 150 nm pitch one-dimensional grating standards were carried out using an contact mode atomic force microscopy(C-AFM) with a high resolution three-axis laser interferometer. It was called as 'Nano-metrological AFM' In Nano-metrological AFM, Three laser interferometers were aligned well to the end of AFM tip. Laser sources of the three-axis laser interferometer in the nano-metrological AFM were calibrated with an I$_2$-stablilzed He-Ne laser at a wavelength of 633 nm. So, the Abbe error was minimized and the result of the pitch measurement using the nano-metrological AFM has a traceability to the length standard directly. The uncertainty in the pitch measurement was estimated in accordance with the Guide to the Expression of Uncertainty in Measurement(GUM). The Primary source of uncertainty in the pitch-measurements was derived from repeatability of pitch-measurement, and its value was approx 0.186 nm. Expanded uncertainty(k=2) of less than 5.23 nm was obtained. It is suggested that the metrological AFM is a useful tool for the nano-metrological standard calibration.

  • PDF

A Reusability Measurement of the Reused Component by Employing Rough and Fuzzy Sets (러프와 퍼지 집합을 이용한 재사용 컴포넌트의 재사용도 측정)

  • Kim, Hye-Gyeong;Choe, Wan-Gyu;Lee, Seong-Ju
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.9
    • /
    • pp.2365-2372
    • /
    • 1999
  • The reusability measurement model should satisfy the following conditions : 1) can insert and delete metrics and components easily, 2) can compare and evaluate components quantitatively on the basis of validation, 3) don't require certain preassumed knowledge, and 4) can compute significance of each measurement attribute objectively. Therefore, in this paper, we propose a new reusability measurement model that can satisfy the above requirements. Our model selects the appropriate measurement attributes and calculates the relative significance of them by using rough set. Then, in order to measure the reusability of component, it integrates the significance of attributes and the measured value of them by using fuzzy integral. Finally, we apply our model to the reusability measurement of the function-oriented components and validate our model through statistical technique.

  • PDF