• Title/Summary/Keyword: T1WI

Search Result 218, Processing Time 0.032 seconds

Analysis of IoT Security in Wi-Fi 6 (Wi-Fi 6 환경에서의 IoT 보안 분석)

  • Kim, HyunHo;Song, JongGun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.1
    • /
    • pp.38-44
    • /
    • 2021
  • Wi-Fi provides some low-power connection solutions that other Bluetooth cannot provide, and at the same time brings many benefits. First, there is a potentially higher data rate: it can reach 230mbps. Wi-Fi coverage is also wider than competitors, and its operating frequency is also 5GHz, which is much less congested than 2.4GHz. Finally, it also supports IP networks, which is important if you want to send data to the cloud without complexity. The 802.11ac standard of the previous generation still accounts for most shipments (80.9%) and revenue (76.2%). However, there is a limit to accepting IoT devices that will continue to increase significantly in the future. To solve this problem, the new Wi-Fi 6 standard is expected to be the solution (IEEE 802.11ax) which is quickly becoming the main driving force of the wireless local area network (WLAN) market. According to IDC market research analysts, in the first quarter of 2020, independent access points (APs) supported by Wi-Fi 6 accounted for 11.8% of shipments, but 21.8% of revenue. In this paper, we have compared and analyzed the IoT connectivity, QoS, and security requirements of devices using Wi-Fi 6 network.

A Real-time Implementation of G.729.1 Codec on an ARM Processor for the Improvement of VoWiFi Voice Quality (VoWiFi 음질 향상을 위한 G.729.1 광대역 코덱의 ARM 프로세서에의 실시간 구현)

  • Park, Nam-In;Kang, Jin-Ah;Kim, Hong-Kook
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.230-235
    • /
    • 2008
  • This paper addresses issues associated with the real-time implementation of a wideband speech codec such as ITU-T G. 729. 1 on an ARM processor in order to provide an improved voice quality of a VoWiFi service. The real-time implementation features in optimizing the C-source code of G.729. 1 and replacing several parts of the codec algorithm with faster ones. The performance of the implementation is measured by the CPU time spent for G.729.1 on the ARM926EJ processor that is used for a VoWiFi phone. It is shown from the experiments that the G.729.1 codec works in real-time with better voice quality than G 729 codec that is conventionally used for VoIP or VoWiFi phones.

  • PDF

Diagnostic imaging findings of subcutaneous mast cell tumor in a dog

  • Sojeong Kwon;Min Jang;Sang-Kwon Lee;Kija Lee
    • Korean Journal of Veterinary Research
    • /
    • v.63 no.2
    • /
    • pp.9.1-9.5
    • /
    • 2023
  • A 5-year-old Labrador Retriever presented with a subcutaneous mass on the right scapular region with localized calor. On magnetic resonance imaging (MRI), a heterogeneously hypointense mass was seen on T1-weighted images (WI) and hyperintense on T2WI and fat-suppressed T2WI with marginal contrast enhancement on postcontrast T1WI and invasion into the surrounding tissue. Histopathological examination of the mass confirmed subcutaneous mast cell tumor (MCT) infiltrating to the adjacent subcutaneous fat. This is the first report to describe the MRI findings of subcutaneous MCT in veterinary medicine. This study suggests that MRI may help evaluate the extent of invasion of subcutaneous MCT.

Synthesis of T2-weighted images from proton density images using a generative adversarial network in a temporomandibular joint magnetic resonance imaging protocol

  • Chena, Lee;Eun-Gyu, Ha;Yoon Joo, Choi;Kug Jin, Jeon;Sang-Sun, Han
    • Imaging Science in Dentistry
    • /
    • v.52 no.4
    • /
    • pp.393-398
    • /
    • 2022
  • Purpose: This study proposed a generative adversarial network (GAN) model for T2-weighted image (WI) synthesis from proton density (PD)-WI in a temporomandibular joint(TMJ) magnetic resonance imaging (MRI) protocol. Materials and Methods: From January to November 2019, MRI scans for TMJ were reviewed and 308 imaging sets were collected. For training, 277 pairs of PD- and T2-WI sagittal TMJ images were used. Transfer learning of the pix2pix GAN model was utilized to generate T2-WI from PD-WI. Model performance was evaluated with the structural similarity index map (SSIM) and peak signal-to-noise ratio (PSNR) indices for 31 predicted T2-WI (pT2). The disc position was clinically diagnosed as anterior disc displacement with or without reduction, and joint effusion as present or absent. The true T2-WI-based diagnosis was regarded as the gold standard, to which pT2-based diagnoses were compared using Cohen's ĸ coefficient. Results: The mean SSIM and PSNR values were 0.4781(±0.0522) and 21.30(±1.51) dB, respectively. The pT2 protocol showed almost perfect agreement(ĸ=0.81) with the gold standard for disc position. The number of discordant cases was higher for normal disc position (17%) than for anterior displacement with reduction (2%) or without reduction (10%). The effusion diagnosis also showed almost perfect agreement(ĸ=0.88), with higher concordance for the presence (85%) than for the absence (77%) of effusion. Conclusion: The application of pT2 images for a TMJ MRI protocol useful for diagnosis, although the image quality of pT2 was not fully satisfactory. Further research is expected to enhance pT2 quality.

Magnetic resonance imaging characteristic of lymph nodes: Comparison of T1 and T2 weighted image in normal rabbits (림프절의 자기공명영상의 특징: 가토에서 T1과 T2 강조영상의 비교)

  • Lee, Ki-chang;Choi, Min-cheol;Choi, Ho-Jung;Yoon, Jung-hee;Choi, Seong-hong;Moon, Woo-kyung;Chung, Jin-Wook
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.2
    • /
    • pp.311-315
    • /
    • 2004
  • The detection of lymph node metastasis is an important step in tumor staging and is significant for therapy planning. It has been challenged to yield an appropriate image with diagnostic methods such as Magnetic Resonance (MR) and Computed Tomography (CT). Though CT has been used widely and accessed easily to show internal organs, it can hardly provide difference between lymph node and adjacent vessel or fat tissue. It has been well established that MR can reveal the subtle discrepancy within soft tissue. This study investigated the suitability of MR lymph node imaging without contrast enhancement by comparison of T1-weighted image (T1WI) and T2- weighted image (T2WI) in ten normal rabbits. According to the pulse sequence optimized from preliminary study, T1-weighted spin-echo (repetition time/echo time=400/12 ms) and T-2 weighted fast spin-echo (repetition time/echo time=3500/84 ms) images covering the hind limbs and pelvic region were acquired at 1.5 T. Two radiologists scrupulously evaluated the MR images in consensus. And signal intensity of lymph nodes was compared with that of adjacent fat. Statistical analysis showed that T1-weighted coronal image visualized the lymph nodes (iliac, superficial inguinal and popliteal lymph nodes) quickly and consistently rather than T2-weighted one. Conclusively, T1WI for evaluation of lymph nodes is moderately better than T2WI and appears to have potential for quick and sufficient mapping of the lymph nodes. In addition, this normal MR image of lymph nodes could be applied to further study for the evaluation of lymphatic system in abscess and tumor bearing animal model.

Development and Validation of a Model Using Radiomics Features from an Apparent Diffusion Coefficient Map to Diagnose Local Tumor Recurrence in Patients Treated for Head and Neck Squamous Cell Carcinoma

  • Minjae Kim;Jeong Hyun Lee;Leehi Joo;Boryeong Jeong;Seonok Kim;Sungwon Ham;Jihye Yun;NamKug Kim;Sae Rom Chung;Young Jun Choi;Jung Hwan Baek;Ji Ye Lee;Ji-hoon Kim
    • Korean Journal of Radiology
    • /
    • v.23 no.11
    • /
    • pp.1078-1088
    • /
    • 2022
  • Objective: To develop and validate a model using radiomics features from apparent diffusion coefficient (ADC) map to diagnose local tumor recurrence in head and neck squamous cell carcinoma (HNSCC). Materials and Methods: This retrospective study included 285 patients (mean age ± standard deviation, 62 ± 12 years; 220 male, 77.2%), including 215 for training (n = 161) and internal validation (n = 54) and 70 others for external validation, with newly developed contrast-enhancing lesions at the primary cancer site on the surveillance MRI following definitive treatment of HNSCC between January 2014 and October 2019. Of the 215 and 70 patients, 127 and 34, respectively, had local tumor recurrence. Radiomics models using radiomics scores were created separately for T2-weighted imaging (T2WI), contrast-enhanced T1-weighted imaging (CE-T1WI), and ADC maps using non-zero coefficients from the least absolute shrinkage and selection operator in the training set. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic performance of each radiomics score and known clinical parameter (age, sex, and clinical stage) in the internal and external validation sets. Results: Five radiomics features from T2WI, six from CE-T1WI, and nine from ADC maps were selected and used to develop the respective radiomics models. The area under ROC curve (AUROC) of ADC radiomics score was 0.76 (95% confidence interval [CI], 0.62-0.89) and 0.77 (95% CI, 0.65-0.88) in the internal and external validation sets, respectively. These were significantly higher than the AUROC values of T2WI (0.53 [95% CI, 0.40-0.67], p = 0.006), CE-T1WI (0.53 [95% CI, 0.40-0.67], p = 0.012), and clinical parameters (0.53 [95% CI, 0.39-0.67], p = 0.021) in the external validation set. Conclusion: The radiomics model using ADC maps exhibited higher diagnostic performance than those of the radiomics models using T2WI or CE-T1WI and clinical parameters in the diagnosis of local tumor recurrence in HNSCC following definitive treatment.

How to Combine Diffusion-Weighted and T2-Weighted Imaging for MRI Assessment of Pathologic Complete Response to Neoadjuvant Chemoradiotherapy in Patients with Rectal Cancer?

  • Jong Keon Jang;Chul-min Lee;Seong Ho Park;Jong Hoon Kim;Jihun Kim;Seok-Byung Lim;Chang Sik Yu;Jin Cheon Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.9
    • /
    • pp.1451-1461
    • /
    • 2021
  • Objective: Adequate methods of combining T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) to assess complete response (CR) to chemoradiotherapy (CRT) for rectal cancer are obscure. We aimed to determine an algorithm for combining T2WI and DWI to optimally suggest CR on MRI using visual assessment. Materials and Methods: We included 376 patients (male:female, 256:120; mean age ± standard deviation, 59.7 ± 11.1 years) who had undergone long-course CRT for rectal cancer and both pre- and post-CRT high-resolution rectal MRI during 2017-2018. Two experienced radiologists independently evaluated whether a tumor signal was absent, representing CR, on both post-CRT T2WI and DWI, and whether the pre-treatment DWI showed homogeneous hyperintensity throughout the lesion. Algorithms for combining T2WI and DWI were as follows: 'AND,' if both showed CR; 'OR,' if any one showed CR; and 'conditional OR,' if T2WI showed CR or DWI showed CR after the pre-treatment DWI showed homogeneous hyperintensity. Their efficacies for diagnosing pathologic CR (pCR) were determined in comparison with T2WI alone. Results: Sixty-nine patients (18.4%) had pCR. AND had a lower sensitivity without statistical significance (vs. 62.3% [43/69]; 59.4% [41/69], p = 0.500) and a significantly higher specificity (vs. 87.0% [267/307]; 90.2% [277/307], p = 0.002) than those of T2WI. Both OR and conditional OR combinations resulted in a large increase in sensitivity (vs. 62.3% [43/69]; 81.2% [56/69], p < 0.001; and 73.9% [51/69], p = 0.008, respectively) and a large decrease in specificity (vs. 87.0% [267/307]; 57.0% [175/307], p < 0.001; and 69.1% [212/307], p < 0.001, respectively) as compared with T2WI, ultimately creating additional false interpretations of CR more frequently than additional identification of patients with pCR. Conclusion: AND combination of T2WI and DWI is an appropriate strategy for suggesting CR using visual assessment of MRI after CRT for rectal cancer.

Benefit of Using Early Contrast-Enhanced 2D T2-Weighted Fluid-Attenuated Inversion Recovery Image to Detect Leptomeningeal Metastasis in Lung-Cancer Staging

  • Kim, Han Joon;Lee, Jungbin;Lee, A Leum;Lee, Jae-Wook;Kim, Chan-Kyu;Kim, Jung Youn;Park, Sung-Tae;Chang, Kee-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.26 no.1
    • /
    • pp.32-42
    • /
    • 2022
  • Purpose: To evaluate the clinical benefit of 2D contrast-enhanced T2 fluid-attenuated inversion recovery (CE-T2 FLAIR) image for detecting leptomeningeal metastasis (LM) in the brain metastasis work-up for lung cancer. Materials and Methods: From June 2017 to July 2019, we collected all consecutive patients with lung cancer who underwent brain magnetic resonance image (MRI), including contrast-enhanced 3D fast spin echo T1 black-blood image (CE-T1WI) and CE-T2 FLAIR; we recruited clinico-radiologically suspected LM cases. Two independent readers analyzed the images for LM in three sessions: CE-T1WI, CE-T2 FLAIR, and their combination. Results: We recruited 526 patients with suspected lung cancer who underwent brain MRI; of these, we excluded 77 (insufficient image protocol, unclear pathology, different contrast media, poor image quality). Of the 449 patients, 34 were clinico-radiologically suspected to have LM; among them, 23 were diagnosed with true LM. The calculated detection performance of CE-T1WI, CE-T2 FLAIR, and combined analysis obtained from the 34 suspected LM were highest in the combined analysis (AUC: 0.80, 0.82, and 0.89, respectively). The inter-observer agreement was also the highest in the combined analysis (0.68, 0.72, and 0.86, respectively). In quantitative analyses, CNR of CE-T2 FLAIR was significantly higher than that of CE-T1WI (Wilcoxon signed rank test, P < 0.05). Conclusion: Adding CE-T2 FLAIR might provide better detection for LM in the brain-metastasis screening for lung cancer.

Should We Recommend Ultrasonography for an Incidental Thyroid Nodule on Additional Cervicothoracic Sagittal T2-Weighted Image of Lumbar Spine MRI?

  • Cho, Hee Woo;Park, Jin-Oh;Lee, Young Han;Chung, Soo Yoon;Suh, Jin-Suck
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.4
    • /
    • pp.224-230
    • /
    • 2015
  • Purpose: To determine whether we should recommend ultrasonography (US) for an incidental thyroid nodule identified by additional cervicothoracic sagittal T2-weighted image (C-T sag T2WI) of lumbar spine magnetic resonance imaging (MRI). Materials and Methods: A retrospective study of 61 patients who underwent both lumbar spine MRI and thyroid US between December 2011 and April 2015 was conducted. For all US-found thyroid nodules > 1 cm, investigators evaluated whether there was any correlation between thyroid nodule detectability by C-T sag T2WI and US features such as echogenicity, composition, or suspicion of malignancy. Results: Solid hypoechoic (2/4; 50%) or mixed echoic nodules (4/8; 50%) appeared to be found relatively more easily by C-T sag T2WI than more benign-looking solid isoechoic (1/4; 25%) or spongiform nodules (0/6; 0%). Among six nodules with ultrasonographic suspicion for malignancy, only one nodule was detected by C-T sag T2WI. Conclusion: If an incidental thyroid nodule is seen by C-T sag T2WI, it would be better to recommend thyroid US for identifying malignancy.

Measurement of Apparent Diffusion Coefficient Values from Diffusion-Weighted MRI: A Comparison of Manual and Semiautomatic Segmentation Methods

  • Kim, Seong Ho;Choi, Seung Hong;Yoon, Tae Jin;Kim, Tae Min;Lee, Se-Hoon;Park, Chul-Kee;Kim, Ji-Hoon;Sohn, Chul-Ho;Park, Sung-Hye;Kim, Il Han
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.2
    • /
    • pp.88-98
    • /
    • 2015
  • Purpose: To compare the interobserver and intraobserver reliability of mean apparent diffusion coefficient (ADC) values using contrast-enhanced (CE) T1 weighted image (WI) and T2WI as structural images between manual and semiautomatic segmentation methods. Materials and Methods: Between January 2011 and May 2013, 28 patients who underwent brain MR with diffusion weighted image (DWI) and were pathologically confirmed as having glioblastoma participated in our study. The ADC values were measured twice in manual and semiautomatic segmentation methods using CE-T1WI and T2WI as structural images to obtain interobserver and intraobserver reliability. Moreover, intraobserver reliabilities of the different segmentation methods were assessed after subgrouping of the patients based on the MR findings. Results: Interobserver and intraobserver reliabilities were high in both manual and semiautomatic segmentation methods on CE-T1WI-based evaluation, while interobserver reliability on T2WI-based evaluation was not high enough to be used in a clinical context. The intraobserver reliability was particularly lower with the T2WI-based semiautomatic segmentation method in the subgroups with involved $lobes{\leq}2$, with partially demarcated tumor borders, poorly demarcated inner margins of the necrotic portion, and with perilesional edema. Conclusion: Both the manual and semiautomatic segmentation methods on CE-T1WI-based evaluation were clinically acceptable in the measurement of mean ADC values with high interobserver and intraobserver reliabilities.