• Title/Summary/Keyword: T1CE

Search Result 194, Processing Time 0.024 seconds

Synthesis of Nano Size $BaCeO_3$ as an Effective Flux Pining Center for YBCO Superconductor (YBCO 초전도체의 효과적인 플럭스 피닝 센터로서의 나노 크기 $BaCeO_3$ 합성)

  • Youn, J.S.;No, K.S.;Kim, Y.H.;Jun, B.H.;Lee, J.P.;Jung, S.Y.;Kim, C.J.
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.12-16
    • /
    • 2008
  • In this work, nano size $BaCeO_3$, which is a possible flux pinning medium of melt processed $YBa_{2}Cu_{3}O_x$ superconductor, was synthesized by the conventional solid state reaction method using powders. $BaCeO_3$ and $CeO_2$ were mixed thoroughly using a ball milling for 24 hours and calcined at $1200^{\circ}C$ for 5 hours for the formation $BaCeO_3$ powder. The obtained $BaCeO_3$ powder was attrition milled at various milling times of 60 min, 120 min and 240 min. The $BaCeO_3$ powders of various milling times were mixed with $YBa_{2}Cu_{3}O_x$ powder. Seed melt processed $YBa_{2}Cu_{3}O_x$-$BaCeO_3$ (15wt.%) superconductors were prepared and the superconducting properties were investigated. It was found that $T_c$ of $Y_{1.5}Ba_{2}Cu_{3}O_x$ samples was not significantly affected by $BaCeO_3$ addition, but $J_c$ of samples was increased by $BaCeO_3$ addition. The $J_c$ improvement by fine $BaCeO_3$ powder (120 min attrition-milled) was effective at low magnetic fields less than 2 T.

  • PDF

Deposition of $CeO_2$ buffer layer for YBCO coated conductors on biaxially textured Ni substrate by MOCVD technique (양축 정렬된 Ni기판 위에 MOCVD법에 의한 YBCO 초전도 선재용 $CeO_2$ 완충층의 증착)

  • 김호진;주진호;전병혁;정충환;박순동;박해웅;홍계원;김찬중
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.21-26
    • /
    • 2002
  • Textured CeO2 buffer layers for YBCO coated conductors were deposited on biaxially textured Ni substrate by metalorganic chemical vapor deposition (MOCVD). The degree of texture of deposited $CeO_2$ films was strong1y dependent on the deposition temperature (Td) and oxygen Partial Pressure(PO2). ($\ell$00) textured $CeO_2$ films were well deposited at T=500~52$0^{\circ}C$. PO2=0.90~3.33 Torr. The surface morphology showed that the films consisted of columnar CeO2 films grown from the Ni substrates. The root mean square roughness of CeO$_2$ films estimated by atomic force microscopy(AFM) increased as the deposition temperature(Td) increa- sed. The growth rate of the $CeO_2$ films deposited at T=52$0^{\circ}C$ and PO2=2.30 Torr was 150~200 nm/min that was much faster than that of other Physical deposition methods.

The optical and structural properties by ZrO2 and Y2O3 compositional ratio of Co- and Ce-doped cubic zirconia (YSZ) single crystals (ZrO2와 Y2O3 조성비에 따른 Co와 Ce 첨가 큐빅지르코니아(YSZ) 단결정의 광학적 및 구조적 특성)

  • Moon, So-I.;Park, Hee-Yul;Seok, Jeong-Won
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.2
    • /
    • pp.73-77
    • /
    • 2012
  • Co-(0.8 wt%) and Ce-(0.4 wt%) doped cubic zirconia ($ZrO_2$ : $Y_2O_3$ = 80 : 20, 70 : 30, 60 : 40, 50 : 50 wt%) single crystals grown by a skull melting method were heat-treated in $N_2$ at $1000^{\circ}C$ for 5 hrs. The orange, yellowish brown and brown colored as-grown single crystals were changed into either brownish red, yellow and green color after the heat treatment. Before and after the heat treatment, the YSZ (yttria-stabilized zirconia) single crystals were cut for wafer form (${\phi}6.5mm{\times}t2mm$). The optical and structural properties were examined by UV-VIS spectrophotometer and X-ray diffraction. Absorption by $Ce^{3+}(^2F_{5/2,7/2}(4f){\rightarrow}^2T_g(5d^1))$, $Co^{2+}(^4A_2(^4F){\rightarrow}^4T_1(^4F)$ or $^4T_1(^4P))$ and $Co^{3+}$, change of ionization energy and lattice parameter were confirmed.

Value of FDG PET/Contrast-Enhanced CT in Initial Staging of Colorectal Cancer - Comparison with Contrast-Enhanced CT

  • Kunawudhi, Anchisa;Sereeborwornthanasak, Karun;Promteangtrong, Chetsadaporn;Siripongpreeda, Bunchorn;Vanprom, Saiphet;Chotipanich, Chanisa
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.8
    • /
    • pp.4071-4075
    • /
    • 2016
  • Background: FDG PET/CT is at an equivocal stage to recommend for staging of colorectal cancer as compared to contrast-enhanced CT (ceCT). This study was intended to evaluate the value of FDG PET/ceCT in colorectal cancer staging as compared to ceCT alone. Materials and Methods: PET/ceCT was performed for 61 colorectal cancer patients who were prospectively enrolled in the study. Three patients were excluded due to loss to follow-up. PET/ceCT findings and ceCT results alone were read separately. The treatment planning was then determined by tumor board consensus. The criteria for T staging were determined by the findings of ceCT. Nodal positive by PET/ceCT imaging was determined by visual analysis of FDG uptake greater than regional background blood pool activity. The diagnostic accuracy of T and N staging was determined only in patients who received surgery without any neoadjuvant treatment. Results: Of 58 patients, there were 40 with colon cancers including sigmoid cancers and 18 with rectal cancers. PET/ceCT in pre-operative staging detected bone metastasis and metastatic inguinal lymph nodes (M1a) that were undepicted on CT in 2 patients (3%), clearly defined 19 equivocal lesions on ceCT in 18 patients (31%) and excluded 6 metastatic lesions diagnosed by ceCT in 6 patients (10%). These resulted in alteration of management plan in 15 out of the 58 cases (26%) i.e. changing from chemotherapy to surgery (4), changing extent of surgery (9) and avoidance of futile surgery (2). Forty four patients underwent surgery within 45 days after PET/CT. The diagnostic accuracy for N staging with PET/ceCT and ceCT alone was 66% and 48% with false positive rates of 24% (6/25) and 76% (19/25) and false negative rates of 47% (9/19) and 21% (4/19), respectively. All of the false negative lymph nodes from PET/ceCT were less than a centimeter in size and located in peri-lesional regions. The diagnostic accuracy for T staging was 82%. The sensitivity of the peri-lesional fat stranding sign in determining T3 stage was 94% and the specificity was 54%. Conclusions: Our study suggested promising roles of PET/ceCT in initial staging of colorectal cancer with better diagnostic accuracy facilitating management planning.

GENERAL PROPERTIES OF CONTACT BINARY SYSTEM FOR MASS RATIO DISTRIBUTION (접촉식쌍성의 질량비 분포에 따른 일반적 특성)

  • 오규동
    • Journal of Astronomy and Space Sciences
    • /
    • v.16 no.1
    • /
    • pp.31-40
    • /
    • 1999
  • With a total 761 contact binary systems in Svechnikov & Kuznetsova(1990)'s catalogue, their physical properties by the mass ratio are investigated - for the early CE type with a common radiative envelope and the late CW type with a common convective envelope. It is found that the early CE type shows a higher temperature difference($\mid$$DeltaT$$\mid$) between the primary and secondary components, and also longer period, than the late CW type. The mass ratio of the CW type are distributed in period, than the late CW type. The mass ratio of the CW type are distributed in smaller ranges, from 0.3 to 0.7, than the CE type. Further, the relation between mass ratio and luminosity for the CW type shows a well-defined linear relation, such as ratio and luminosity for the CW type shows a well-defined linear relation, such as $L_2/L_1$ = 0.01 = 0.89q. In the mass ratio-radii relation, it is confirmed that the physical difference of the CE and CW types is a result of the secondary radius. A new mass ratio-radii relation for the CW type is suggested for both the total radius $({gamma}_1/{gamma}_2$ and the radius ratio $({gamma}_2/{gamma}_1$, respectively.

  • PDF

Quantitative Analysis of the Facial Nerve Using Contrast-Enhanced Three Dimensional FLAIR-VISTA Imaging in Pediatric Bell's Palsy

  • Seo, Jin Hee;You, Sun Kyoung;Lee, In Ho;Lee, Jeong Eun;Lee, So Mi;Cho, Hyun-Hae
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.3
    • /
    • pp.162-167
    • /
    • 2015
  • Purpose: To evaluate the usefulness of quantitative analysis of the facial nerve using contrast-enhanced three-dimensional (CE 3D) fluid-attenuated inversion recovery-volume isotopic turbo spin echo acquisition (FLAIR-VISTA) for the diagnosis of Bell's palsy in pediatric patients. Materials and Methods: Twelve patients (24 nerves) with unilateral acute facial nerve palsy underwent MRI from March 2014 through March 2015. The unaffected sides were included as a control group. First, for quantitative analysis, the signal intensity (SI) and relative SI (RSI) for canalicular, labyrinthine, geniculate ganglion, tympanic, and mastoid segments of the facial nerve on CE 3D FLAIR images were measured using regions of interest (ROI). Second, CE 3D FLAIR and CE T1-SE images were analyzed to compare their diagnostic performance by visual assessment (VA). The sensitivity, specificity, and accuracy of RSI measurement and VA were compared. Results: The absolute SI of canalicular and mastoid segments and the sum of the five mean SI (total SI) were higher in the palsy group than in the control group, but with no significant differences. The RSI of the canalicular segment and the total SI were significantly correlated with the symptomatic side (P = 0.028 and 0.015). In 11/12 (91.6%) patients, the RSI of total SI resulted in accurate detection of the affected side. The sensitivity, specificity, and accuracy for detecting Bell's palsy were higher with RSI measurement than with VA of CE 3D FLAIR images, while those with VA of CE T1-SE images were higher than those with VA of CE 3D FLAIR images. Conclusion: Quantitative analysis of the facial nerve using CE 3D FLAIR imaging can be useful for increasing the diagnostic performance in children with Bell's palsy when difficult to diagnose using VA alone. With regard to VA, the diagnostic performance of CE T1-SE imaging is superior to that of CE 3D FLAIR imaging in children. Further studies including larger populations are necessary.

Magnetic and Magnetocaloric Properties of (Gd1-xCex)Al2(x = 0, 0.25, 0.5, 0.75) Compounds

  • Gencer, H.;Izgi, T.;Kolat, V.S.;Kaya, A.O.;Atalay, S.
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.337-341
    • /
    • 2011
  • The magnetic and magnetocaloric properties of $Gd_{1-x}Ce_xAl_2$ (x = 0, 0.25, 0.5, 0.75) intermetallic compounds alloys have been investigated in detail for the first time. XRD patterns indicated that all the samples were crystallized in a single phase with $MgCu_2$-type structure (Laves phase). Ce substitution for Gd increased the lattice parameters and decreased the Curie temperature from 163 K for x = 0 to 37 K for x = 0.75. A maximum entropy change of 3.82 J/kg K was observed when a 2 T magnetic field was applied to the x = 0 sample. This entropy change decreased with increasing Ce content to 2.04 J/kg K for the x = 0.75 sample.

The CE101 Test of the Army Aircraft's UHF Band Transceiver (육군 항공기류 UHF 대역 송수신기 CE101 시험)

  • Seo, Jung-Won;Jung, Byoung-Koo;Yoon, Chang-Bae;Shin, Young-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.11
    • /
    • pp.992-998
    • /
    • 2015
  • In case of UHF Band Transceiver for Army Aircraft, it shall follow MIL-STD-461F Figure CE101-4 most key design points for this equipment were to minize the current consumption and frequency interference since it will be integrated on aircraft. However, after design, abnomal signal(over 100 dBuA) was occured from 30 Hz to 1 kHz on CE101 test. Occured abnomal signal was measured as 50 Hz signal which was tansceiver $T_{DD}$ signal with the output power of 10 W and 20 ms periods. To meet the specification, current variation needed to be minized. Thus, $I_{dq}$ and $I_d$ of power amplifier were modified almost equally through test result and finally, the equipment was designed and developed with no difference of current consumption and frequency interference from the previous design goal.

Magnetization characteristics of melt-textured Y-Ba-Cu-O with BaCe$O_{3}$ addition (용융공정으로 제조한 Y-Ba-Cu-O/BaCe$O_{3}$ 초전도체의 자화특성)

  • Kim, Chan-Jung;Park, Hae-Ung;Kim, Gi-Baek;Hong, Gye-Won
    • Korean Journal of Materials Research
    • /
    • v.5 no.4
    • /
    • pp.433-444
    • /
    • 1995
  • BaCe$O_{3}$를 첨가하여 용융공정으로 제조한 단결정형 Y$Ba_{2}$$Cu_{3}$$O_{x}$(1-2-3) 초전도체의 온도에 대한 자화특성을 연구하였다. 고상반응법과 용융공정으로 0에서 30wt% BaCe$O_{3}$를 1-2-3 결정내에 미세 분산시켰다. 초전도체의 자화특성은 VSM(vibrating sample magnetometer)을 사용하여 77K, 60K, 40K와 20K, 2 Tesla 자장범위에서 측정하였다. BaCe$O_{3}$를 첨가하지 않은 겨우나 5wt% BaCe$O_{3}$를 첨가한 1-2-3 결정의 경우, 77K, 외부자장이 증가시 자화율 차이가 증가하는 비정상 자화특성이 관찰된다. 측정온도가 60K에서는 제2차 최대점이 나타나는 자장값이 고자장쪽으로 이동한다. 20K와 40K의 저온에서는 비정상자화특성이 2 T의 자장범위까지 관찰되지 않았다. 15wt%와 20wt% BaCe$O_{3}$첨가한 시편에서는 자장이 증가하면 자화율차이가 단순히 감소한다. Y-Ba-Cu-O의 flux pinning 기구를 BaCe$O_{3}$첨가에 의한 미세조직변화로 설명하였다.

  • PDF

Microstructure and Electrical Properties of (YNdSm)-Ba-Cu-O High Tc Composite Superconductors by Zone Melting Process (존멜팅법으로 제조한 (YNdSm)-Ba-Cu-O계 고온복합초전도체의 미세구조 및 전기적 특성)

  • Kim, So-Jung;Lee, Sang-Heon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.2
    • /
    • pp.110-113
    • /
    • 2016
  • (YNdSm)-Ba-Cu-O system high Tc composite superconductors were directionally grown by zone melting process, having large temperature gradient, in air atmosphere. Cylindrical green rods of $(YNdSm)_{1.8}Ba_{2.4}Cu_{3.4}O_x$ [(YNS)1.8]composite oxides by CIP (cold isostatic pressing) method using rubber mold were fabricated. The microstructure and superconducting properties were investigated by XRD, TEM and SQUID magnetometer. The size of nonsuperconducting $(YNdSm)_2BaCuO_5$ inclusions of the melt-textured (YNS)1.8 sample with $CeO_2$ additive were remarkably reduced and uniformly distributed within the superconducting (YNS)1.8 matrix. (YNS)1.8 samples, with / without $CeO_2$ additive, showed an onset $T_c{\geq}90K$ and sharp superconducting transition. The critical current density $J_c$ value of the (YNdSm)1.8 superconductor with $CeO_2$ additive were 840 A, $1.2{\times}104A/cm^2$ in 77 K, 0 Tesla by direct current transport method.