• Title/Summary/Keyword: T1영상

Search Result 1,496, Processing Time 0.033 seconds

Geotechnical Characterization of Artificial Aggregate made from Recycled Resources of Gwangyang Bay Area as a Drainage Material (광양만권 순환자원으로 제조된 배수재용 인공골재의 지반공학적 특성)

  • Kim, Youngsang;Kim, Wonbong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.10
    • /
    • pp.49-57
    • /
    • 2013
  • Recently, recycling of the industrial by-products has been an important issue of the Yeosu bay, where large industrial complex is located. Major industrial by-products which are produced from Yeosu industrial complex area are phosphogypsum and flyash, which are about 82% and 10% of the 1.6 million tons industrial by-products. Moreover since the Yeosu industrial complex is located at seaside, phosphogypsum has been pointed as cause of serious environmental contaminant from the regional society. Therefore recycling study can't be delayed anymore. In this paper, artificial aggregate was manufactured by non-sintering process from industrial byproducts - e.g., phosphogypsum and slag - as a geotechnical drainage material. To show the feasibility of the artificial aggregate as a geotechnical drainage material, geotechnical experiments including particle size analysis, permeability test, and large scale direct shear test were carried out. Test results show that the permeability of the artificial aggregates range from $6.94{\times}10^{-1}cm/sec$ to $8.86{\times}10^{-1}cm/sec$, which is much larger value than those are required for the drainage material from the construction specification in Korea, and the friction angle of the artificial aggregate is as large as that of sand in water immersion conditions. From the test results, it was concluded that artificial aggregate made from industrial by-products can be used successfully as a geotechnical drainage material.

Quantitative MRI Assessment of Pancreatic Steatosis Using Proton Density Fat Fraction in Pediatric Obesity

  • Jisoo Kim;Salman S. Albakheet;Kyunghwa Han;Haesung Yoon;Mi-Jung Lee;Hong Koh;Seung Kim;Junghwan Suh;Seok Joo Han;Kyong Ihn;Hyun Joo Shin
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1886-1893
    • /
    • 2021
  • Objective: To assess the feasibility of quantitatively assessing pancreatic steatosis using magnetic resonance imaging (MRI) and its correlation with obesity and metabolic risk factors in pediatric patients. Materials and Methods: Pediatric patients (≤ 18 years) who underwent liver fat quantification MRI between January 2016 and June 2019 were retrospectively included and divided into the obesity and control groups. Pancreatic proton density fat fraction (P-PDFF) was measured as the average value for three circular regions of interest (ROIs) drawn in the pancreatic head, body, and tail. Age, weight, laboratory results, and mean liver MRI values including liver PDFF (L-PDFF), stiffness on MR elastography, and T2* values were assessed for their correlation with P-PDFF using linear regression analysis. The associations between P-PDFF and metabolic risk factors, including obesity, hypertension, diabetes mellitus (DM), and dyslipidemia, were assessed using logistic regression analysis. Results: A total of 172 patients (male:female = 125:47; mean ± standard deviation [SD], 13.2 ± 3.1 years) were included. The mean P-PDFF was significantly higher in the obesity group than in the control group (mean ± SD, 4.2 ± 2.5% vs. 3.4 ± 2.4%; p = 0.037). L-PDFF and liver stiffness values showed no significant correlation with P-PDFF (p = 0.235 and p = 0.567, respectively). P-PDFF was significantly associated with obesity (odds ratio 1.146, 95% confidence interval 1.006-1.307, p = 0.041), but there was no significant association with hypertension, DM, and dyslipidemia. Conclusion: MRI can be used to quantitatively measure pancreatic steatosis in children. P-PDFF is significantly associated with obesity in pediatric patients.

Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography (전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가)

  • Kim, Jeong Jin;Jang, Seong Won;Park, Jang Heum;Lee, Kwan Seob;Ha, Dong Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

Musculoskeletal Injuries by Weapons in Korean Soldiers: Four-Year Follow-Up (총기 및 폭발물에 의한 군인의 근골격계 손상: 최근 4년간 분석)

  • Yang, Hanbual;Hwang, Il-Ung;Song, Daeguen;Moon, Gi Ho;Lee, Na Rae;Kim, Kyoung-Nam
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.234-244
    • /
    • 2021
  • Purpose: To date, studies of firearm and explosive injuries in the Korean military have been limited compared to its importance. To overcome this, this study examined the characteristics of musculoskeletal damages in soldiers who have suffered firearm and explosive injuries over the past four years. Materials and Methods: From January 2015 to July 2019, military forces who had suffered musculoskeletal injuries from firearms or explosive substances were included. The medical records and radiographs were reviewed retrospectively, and telephone surveys about Short Musculoskeletal Functional Assessment (SMFA) for this group were conducted. To compare the functional outcomes, statistical analysis was performed using a t-test for the types of weapons, and ANOVA for others. Results: Of the 61 patients treated for firearms and explosives injuries, 30 patients (49.2%) were included after undergoing orthopedic treatment due to musculoskeletal injury. The average age at injury was 26.4 years old (21-52 years old). The number of officers and soldiers was similar. Eleven were injured by gunshot and 19 by an explosive device. Sixteen were treated in the Armed Forces Capital Hospital and 10 at private hospitals. More than half of the 16 patients (53.3%) with a fracture had multiple fractures. The most common injury site was the hand (33.3%), followed by the lower leg (30.0%). There were 14 patients (46.7%) with Gustilo-Anderson classification 3B or higher who required a soft tissue reconstruction. Fifteen patients agreed to join the SMFA survey for the functional outcomes. Between officers and soldiers, officers had better scores in the Bother Index compared to soldiers (p=0.0045). Patients treated in the Armed Forces Capital Hospital had better scores in both the Dysfunction and Bother Index compared to private hospitals (p=0.0008, p=0.0149). Conclusion: This is the first study to analyze of weapons injuries in the Korean military. As a result of the study, the orthopedic burden was high in the treating patients with military weapon injuries. In addition, it is necessary to build a military trauma registry, including firearm and explosive injuries, for trauma treatment evaluation and development of military trauma system.

Hybrid Two-Dimensional Proton Spectroscopic Imaging of Pediatric Brain: Clinical Application (소아 뇌에서의 혼성 이차원 양성자자기공명분광법의 임상적 응용)

  • Sung Won Youn;Sang Kwon Lee;Yongmin Chang;No Hyuck Park;Jong Min Lee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.64-72
    • /
    • 2002
  • Purpose : To introduce and demonstrate the advantages of the new hybrid two-dimensional (2D) proton spectroscopic imaging (SI) over the single voxel spectroscopy (SVS) and conventional 2D SI in the clinical application of spectroscopy for pediatric cerebral disease. Materials and Methods : Eighty-one hybrid 2D proton spectroscopic imaging was performed in 79 children (36 normal infants and children, 10 with hypoxic-ischemic injury, 20 with toxic-metabolic encephalopathy, seven with brain tumor, three with meningoencephalitis, one with neurofibromatosis, one with Sturge-Weber syndrome and one with lissencephaly) ranging in age from the third day of life to 15 years. In adult volunteers (n=5), all three techniques including hybrid 2D proton SI, SVS using PRESS sequence, and conventional 2D proton SI were performed. Both hybrid 2D proton SI and SVS using PRESS sequence were performed in clinical cases (n=). All measurements were performed with a 1.5-T scanner using standard head quadrature coil. The 16$\times$16 phase encoding steps were set on variable field of view (FOV) depending on the size of the brain. The hybrid volume of interest inside FOV was set as $75{\times}75{\times}15{\;}\textrm{mm}^3$ or smaller to get rid of unwanted fat signal. Point-resolved spectroscopy (TR/TE=1,500 msec/135 or 270msec) was employed with standard chemical shift selective saturation (CHESSI pulses for water suppression. The acquisition time and spectral quality of hybrid 2D proton SI were compared with those of SVS and conventional 2D proton SI. Results : The hybrid 2D proton SI was successfully conducted upon all patients.

  • PDF

Usefulness of MRCP in the Diagnosis of Common Bile Duct Dilatation caused by Non-stone or Non-tumorous Conditions (비결석, 비종양성 총담관 확장의 진단에 있어서 자기공명담췌관조영술(MRCP)의 유용성)

  • 정재준;양희철;김명진;김주희;이종태;유형식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.129-136
    • /
    • 2002
  • Purpose : To evaluate the usefulness of MRCP in the diagnosis of the variable causes of common bile duct(CBD) dilatation, except stone or tumor Materials and methods : Twenty-six patients(M:F=15:11, mean age; 62 years) with both MRCP and ERCP were included in this study. Dynamic MRCP(n=12) and contrast-enhanced MRI(n=10) of abdomen were also added. Dilatation of CBD, intrahepatic ducts and pancreatic duct was evaluated, including coexistence of intrahepatic ductal stone, pancreatic pseudocyst, and papillary or papillary edema. The criteria of CBD dilatation was over than 7mm(n= 21, without cholecystectomy) or 10 mm(n=5, with cholecystecto-my) in diameter on T2-weighted coronal image. Results : The mean diameter of CBD was 12.7mm without cholecystectomy(9-19 mm) and 13.0 mm with cholecystectomy(10-15mm), respectively(p 〉0.05). Cholangitis(n=11, 42.3%), chronic pancreatitis(n=8, 30.8%), stenosis of distal CBD(n= 6, 23.1%), periampullary diverticulum(n=3, 11.5%), stenosis of ampulla of Vater(n=2, 7.7%), dysfunction of sphincter of Oddi(n=2, 7.7%), acute focal pancreatitis in the pancreatic head(n=2, 7.7%), papillitis(n=1, 3.8%), pseudocyst in the pancre atic head(n = 1, 3.8%), and ascaris in CBD(n=1, 3.8%) were noted. Pancreatic duct dilatation(n=10, 38.5%) and duodenal diverticulum(n=3, 11.5%) were also seen on MRC P. On dynamic MRCP(12 patients), distal CBD was visualized in 2 patients(16.7%), which was not shown on routine MRCP. Only 1 patient(10.0%) showed papillitis with slightly enhancing papilla on contrast-enhanced MRI (10 patients). Conclusion : MRCP was thought to be helpful in the evaluation of the causes of CBD dilatation, not caused by stone or tumor, especially in the cases of stenosis of distal CBD and chronic pancreatitis, dysfunction of sphincter of Oddi on dynamic MRCP and cholangitis and pericholangitic abnormality on contrast-enhanced MRI.

  • PDF

Comparative Analysis of the Effects of Heat Island Reduction Techniques in Urban Heatwave Areas Using Drones (드론을 활용한 도시폭염지역의 열섬 저감기법 효과 비교 분석)

  • Cho, Young-Il;Yoon, Donghyeon;Shin, Jiyoung;Lee, Moung-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_3
    • /
    • pp.1985-1999
    • /
    • 2021
  • The purpose of this study is to apply urban heat island reduction techniques(green roof, cool roof, and cool pavements using heat insulation paint or blocks) recommended by the Environmental Protection Agency (EPA) to our study area and determine their actual effects through a comparative analysis between land cover objects. To this end, the area of Mugye-ri, Jangyu-myeon, Gimhae, Gyeongsangnam-do was selected as a study area, and measurements were taken using a drone DJI Matrice 300 RTK, which was equipped with a thermal infrared sensor FLIR Vue Pro R and a visible spectrum sensor H20T 1/2.3" CMOS, 12 MP. A total of nine heat maps, land cover objects (711) as a control group, and heat island reduction technique-applied land covering objects (180) were extracted every 1 hour and 30 minutes from 7:15 am to 7:15 pm on July 27. After calculating the effect values for each of the 180 objects extracted, the effects of each technique were integrated. Through the analysis based on daytime hours, the effect of reducing heat islands was found to be 4.71℃ for cool roof; 3.40℃ for green roof; and 0.43℃ and -0.85℃ for cool pavements using heat insulation paint and blocks, respectively. Comparing the effect by time period, it was found that the heat island reduction effect of the techniques was highest at 13:00, which is near the culmination hour, on the imaging date. Between 13:00 and 14:30, the efficiency of temperature reduction changed, with -8.19℃ for cool roof, -5.56℃ for green roof, and -1.78℃ and -1.57℃ for cool pavements using heat insulation paint and blocks, respectively. This study was a case study that verified the effects of urban heat island reduction techniques through the use of high-resolution images taken with drones. In the future, it is considered that it will be possible to present case studies that directly utilize micro-satellites with high-precision spatial resolution.

A Comparative Study on the CT Effective Dose by the Position of Patient's Arm (전신 PET/CT 검사에서 환자의 팔 위치에 따른 CT 유효선량의 비교 연구)

  • Seong, Ji-Hye;Park, Soon-Ki;Kim, Jung-Sun;Park, Seung-Yong;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.44-49
    • /
    • 2012
  • Purpose: In the whole body PET/CT scan, it is natural to lift the patient's arm for its quality improvement. However, when the lesion is located in head and neck, the arms should be located lower. This study was designed to compare the CT effective dose for each arm position applying Automatic Exposure Control (AEC). Materials and Methods: 45 patients who had $^{18}F$-FDG whole body PET/CT scan were studied with Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY), Discovery STe 8 (GE healthcare, USA). The CT effective dose of 15 patients for each equipment was measured and comparatively analyzed in both arm-lifted position and lower-arm position. ImPACT v1.0 program was used as the method of measurement for CT effective dose. For the statistics analysis, Paired t-test which paired with SPSS 18.0 statistic program was applied. Results: In the case of arm-lifted, it was measured as $6.33{\pm}0.93mSv$ for Biograph Sensation 16, $8.01{\pm}1.34mSv$ for Biograph Truepoint 40, and $9.69{\pm}2.32mSv$ for Discovery STe 8. When arms are located lower position, it was measure as $6.97{\pm}0.76mSv$, $8.95{\pm}1.85mSv$, $13.07{\pm}2.87mSv$ for each. CT effective dose according to the arm position was 9.2% for Biograph Truepoint 40, 10.5% for Biograph Sensation 16, and 25.9% for Discovery Ste 8. The statistics analysis showed the meaningful difference ($p$<0.05). Conclusion: For the whole body PET/CT case, CT effective dose applying AEC was decreased the radiation exposure of the patients when the arm was lifted for 15.2% of average value. The patient who has no lesion in head and neck would decrease the artifact occurrence in objective part and lower the CT effective dose. Also, for the patient who had lesion in head and neck, the artifact in objective part can be lower by putting the arms down, the fact that CT effective dose increases should be concerned in its whole body PET/CT scan.

  • PDF

A Kinematics Analysis of Uchi-mata(inner thigh reaping throw) by Kumi-kata types and Two different Opponent's Height in Judo[II] (유도 맞잡기 타입과 받기의 신장에 따른 허벅다리걸기의 Kinematic 분석[2])

  • Kwon, Moon-Seok;Kim, Eui-Hwan;Cho, Dong-Hee
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.143-157
    • /
    • 2002
  • This study was to analyze the kinematic variables when the subjects performing Uchi-mata(inner thigh reaping throw) by Kumi-kata types((How to grasp A or B?) and two different opponent's height in Judo. Kinematic variables were temporal, posture. Data analysis was collective comparison of two-way ANOVA, t-test by type A&B and two different opponent's height. There were significant difference of Kumi-kata types(p<.05) in the time elapsed on Kake phase(KP : throwing phase) and hip, knee, ankle-angle of the attacking foot in the 1st stage of KP and knee, ankle-angle of the attacking foot and hip, knee ankle-angle of the supporting foot in the 2nd stage of KP. There were significant difference of two opponent's(p<.05) in the time elapsed on KP and hip-angle of the supporting foot in 1st stage of KP. Therefore, the interaction effect(p<.05) were in the time elapsed on KP and hip-angle of the supporting foot in the 2nd stage of KP. So, It could be suggested that Judoka hold on the part-behind neck lapel(type A) at the sleeve with the other of Judogi jacked when opponent's height was short. Because the time elapsed on KP of type B was not so fast as type A(p<.05) during performed Uchi-mata, and also the bigger hip-angle of the supporting foot in the 2nd stage of KP grew, the faster the time elapsed on KP became.

Neuro-Anatomical Evaluation of Human Suitability for Rural and Urban Environment by Using fMRI (자연과 도시환경의 인체친화성에 대한 신경해부학적 평가: 기능적 자기공명영상법)

  • Kim, Gwang-Won;Song, Jin-Kyu;Jeong, Gwang-Woo
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.18-27
    • /
    • 2011
  • The purpose of this study was to identify different cerebral areas of the human brain associated with rural and urban picture stimulation using a 3.0 Tesla functional magnetic resonance imaging (fMRI) and further to investigate the human suitability for rural and urban environments. A total of 27 right-handed participants (mean age: $27.3{\pm}3.7$) underwent fMRI study on a 3.0T MR scanner. The brain activation patterns were induced by visual stimulation with each rural and urban sceneries. The participants were divided into two groups as 26 subjects favorable to rural scenery and 14 subjects unfavorable to urban scenery based on their filled-in questionnaire. The differences of the brain activation in response to two extreme types of pictures by the two sample t-test were characterized as follows: the activation areas observed in rural scenery over urban were the insula, middle frontal gyrus, precuneus, caudate nucleus, superior parietal gyrus, superior occipital gyrus, fusiform gyrus, and globus pallidus. In urban scenery over rural, the inferior frontal gyrus, parahippocampal gyrus, postcentral gyrus, superior temporal gyrus, amygdala, and posterior cingulate gyrus were activated. The fMRI patterns also clearly show that rural scenery elevated positive emotion such as happiness and comfort. On the contrary, urban scenery elevated negative emotion, resulting in activation of the amygdala which is the key region for the feelings of fear, anxiety and unpleasantness. This study evaluated differential cerebral areas of the human brain associated with rural and urban picture stimulation using a 3.0 Tesla fMRI. These findings will be useful as an objective evaluation guide to human suitability for ecological environments that are related to brain activation with joy, anger, sorrow and pleasure.