• Title/Summary/Keyword: T1강조영상

Search Result 261, Processing Time 0.02 seconds

The increase of blood vessels using a signal during the image acquisition phase T1 shortening effect (위상영상 획득 시 T1 shortening effect를 이용한 혈관의 신호 증가에 관한 연구)

  • Lee, Ho-Beom;Choi, Kwan-Woo;Son, Soon-Yong;Min, Jung-Whan;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4704-4710
    • /
    • 2015
  • The purpose of this study is to obtain a useful diagnostic image by increasing the signal strength of the peripheral artery, was to use a T1 shortening effect of gadolinium contrast agents to improve the disadvantages of the phase image. From october to december 2014 thirty patients were underwent the MRI scanning, except for heart disease. Research method was evaluated comparing the image after gadolinium contrast MR image acquisition step before evaluating the difference between the signal intensity for T1 shortening effect. In frontal lobe 19.45%, temporal lobe 23.09%, occipital lobe 25.45%, parietal lobe 18.82%, cerebellum 20.93% after peripheral arterial signal strength results of gadolinium contrast agent injection was increased significantly after injection of gadolinium both statistically significant. After injecting a contrast agent gadolinium in SWI by increasing the signal strength of the T1 shortening effect can be obtained when using the phase image to give a useful image in diagnosis and treatment.

A case of congenital neurocutaneous melanosis (선천성 신경피부멜라닌증 1례)

  • Ha, Sang Kyun;Lee, Jae Myoung;Kim, Eun Ryoung;Hwang, Ho;Lee, Hong Tak
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.2
    • /
    • pp.212-216
    • /
    • 2006
  • Neurocutaneous melanosis is a rare congenital syndrome characterized by the presence of large or multiple congenital melanocytic nevi and benign pigment cell tumors of the leptomeninges. Neurocutaneous melanosis is thought to represent an error in the morphogenesis of embryonal neuroectoderm. We experienced a neonate who presented with giant, dark colored pigmented nevi covering chest, abdomen, neck and arms, with satellite lesions. Magnetic resonance image showed a nodular hyperintense lesion in the amygdala of the right temporal lobe, and T1-weighted images showed hyperintensities in the adjacent leptomeninges. We report a rare case of neurocutaneous melanosis with a brief review of related literature.

Superior Labral Dimension of the Glenohumeral Joint on Direct MR Arthrography (MRA): Relationship with Presence of SLAP (Superior Labrum Anterior to Posterior) Lesion (직접 자기공명 견관절 조영술 상에서 상부 관절순의 크기: 상부 관절순 전후방 파열과의 관계)

  • Im, Tae Seong;Choi, Jung-Ah;Oh, Joo Han
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.193-199
    • /
    • 2014
  • Purpose : To evaluate the relationship between superior labral dimension of the glenohumeral joint on direct MRA and presence of SLAP lesion. Materials and Methods: IRB approval was obtained and informed consent was waived for this retrospective study. Direct MRA studies of the shoulder in 296 patients (300 shoulders) with arthroscopic surgery were analyzed by two radiologists blinded to the arthroscopic results, which were used as gold standard. One of the radiologists reviewed the images twice (session 1 and 2) for the evaluation of intra-observer variability. Transverse and longitudinal dimensions of superior labrum on coronal T1-weighted images were measured as base and height of the inverted triangular-shaped superior labrum and compared between patients with SLAP lesions vs. non-SLAP patients. Presence of meniscoid labrum was noted. Statistical analysis was done using unpaired t-test. Results: Among 279 patients (283 shoulders), 122 patients (43.1%) had SLAP lesions. The mean base/height of superior labrum in SLAP and non-SLAP patients measured on T1-weighted MR image were 8.8 mm / 5.2 mm, 8.5 mm / 4.9 mm for reader 1; 8.2 mm / 4.9 mm, 8.1 mm / 4.5 mm for session 1 of reader 2; 8.0 mm / 4.8 mm, 7.6 mm / 4.3 mm for session 2 of reader 2. In SLAP group, the mean labral height was larger than non-SLAP group with statistically significant difference (p<0.05). Fifteen patients (5.3%) had meniscoid labrum according to operation records. Conclusion: In patients with SLAP lesion, the height of the superior glenoid labrum on oblique coronal image of MRA was slightly larger than non-SLAP patients. A larger height of superior glenoid labrum may be associated with SLAP lesions.

Comparison of In-Phase and Opposed-Phase FMPSPGR Images in Breath-hold T1-weighted MR IMaging of Liver (호흡정지 T1 강조 간 자기공명영상에서 동위상 역위상 FMPSPGR 영상의 비교)

  • 김명진;김만득;정재준;이종태;유형식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.142-147
    • /
    • 1997
  • Purpose: To compare the effectiveness of the in-phase (IP) sequence and the opposed-phase (Op) sequence in the detection of focal hepatic lesions in the single breath-hold hepatic MR imaging with fast gradient T1-weighted pulse sequences. Materials and Methods: IP and OP T1-weighted breath-hold imaging was performed using fast gradient echo sequences in 45 patients referred for known focal hepatic lesions, in which 78 lesions were detected. Three blind readers independently reviewed the images for lesion detectability. The signal-to-noise ratio (SNR) of the liver, the lesion-to-liver contrast-to-noise ratio (CNR) and the liver-to-spleen CNR were also compared. A consensus was reached by three readers to determine which sequence is better in image quality. Results: On OP images, 61(78%), 61(78%), and 63(89%) lesions were correctly identified for reader 1, 2 and 3, respectively. On IP images, 66(85%), 65(83%), and 65(93%) lesions were detected for each reader, respectively. When two image sets were combined, 71(91 %), 69(88 %), and 76(97%) lesions respectively were detected for each reader. In cases of hepatocellular carcinoma, liver-to-Iesion CNR was greater on the OP images(p (0.05), but in other lesions significant difference was not demonstrated. Liver-to-spleen CNR was higher on OP images(p ( 0.1), but the SNR of the liver was higher on the IP images. Conclusion: Use of both IP and OP imaging can be helpful to avoid erroneous missing of some focal hepatic lesions.

  • PDF

Low Frequency Fluctuation Component Analysis in Active Stimulation fMRI Paradigm (활성자극 파라다임 fMRI에서 저주파요동 성분분석)

  • Na, Sung-Min;Park, Hyun-Jung;Chang, Yong-Min
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.2
    • /
    • pp.115-120
    • /
    • 2010
  • Purpose : To separate and evaluate the low frequency spontaneous fluctuation BOLD signals from the functional magnetic resonance imaging data using sensorimotor active task. Materials and Methods : Twenty female archery players and twenty three control subjects were included in this study. Finger-tapping task consisted of three cycles of right finger tapping, with a subsequent 30 second rest. Blood oxygenation level-dependent (BOLD) data were collected using $T2^*$-weighted echo planar imaging at a 3.0 T scanner. A 3-D FSPGR T1-weighted images were used for structural reference. Image processing and statistical analyses were performed using SPM5 for active finger-tapping task and GIFT program was used for statistical analyses of low frequency spontaneous fluctuation BOLD signal. Results : Both groups showed the activation in the left primary motor cortex and supplemental motor area and in the right cerebellum for right finger-tapping task. ICA analysis using GIFT revealed independent components corresponding to contralateral and ipsilateral sensorimotor network and cognitive-related neural network. Conclusion : The current study demonstrated that the low frequency spontaneous fluctuation BOLD signals can be separated from the fMRI data using finger tapping paradigm. Also, it was found that these independent components correspond to spontaneous and coherent neural activity in the primary sensorimotor network and in the motor-cognitive network.

Magnetic Resonance Elastography (자기 공명 탄성법)

  • Kim, Dong-Hyun;Yang, Jae-Won;Kim, Myeong-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.10-19
    • /
    • 2007
  • Conventional MRI methods using T1-, T2-, diffusion-, perfusion-weighting, and functional imaging rely on characterizing the physical and functional properties of the tissue. In this review, we introduce an imaging modality based on measured the mechanical properties of soft tissue, namely magnetic resonance elastography (MRE). The use of palpation to identify the stiffness of tissue remains a fundamental diagnostic tool. MRE can quantify the stiffness of the tissue thereby providing a objective means to measure the mechanical properties. To accomplish a successful clinical setting using MRE, hardware and software techniques in the area of transducer, pulse sequence, and imaging processing algorithm need to be developed. Transducer, a mechanical vibrator, is the core of MRE application to make wave propagate invivo. For this reason, considerations of the frame of human body, pressure and friction of the interface, and high magnetic field of a MRI system needs to be taken into account when designing a transducer. Given that the wave propagates through human body effectively, developing an appropriate pulse sequence is another important issue in obtaining an optimal image. In this review paper, we introduce the technical aspects needed for MRE experiments and introduce several applications of this new field.

  • PDF

Pathophysiology and MRI Findings of Infectious Spondylitis and the Differential Diagnosis (감염성 척추염과 감별질환의 병태생리와 MRI 소견)

  • Sunjin Ryu;Yeo Ju Kim;Seunghun Lee;Jeongah Ryu;Sunghoon Park;Jung Ui Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1413-1440
    • /
    • 2021
  • On MRI, abnormal signals of the intervertebral disc, destruction of the upper and lower vertebral body endplate around the disc, and bone marrow edema around the endplate are considered typical findings of infectious spondylitis. These findings can also appear in various non-infectious spinal diseases, such as degenerative changes, acute Schmorl's node, spondyloarthropathy, synovitis, acne, pustulosis, hyperostosis, and osteitis (SAPHO), chronic recurrent multifocal osteomyelitis, and calcium pyrophosphate dihydrate crystal deposition disease. The imaging findings of infectious spondylitis that can be differentiated from these non-infectious spinal diseases on MRI are high signal intensity and abscess of the disc space, an abscess in the paraspinal soft tissue, and the loss of the linear low signal intensity on T1-weighted images of the bony endplate. However, these differentiation points do not always apply since there are many similarities in the imaging findings of infectious and non-infectious diseases. Therefore, for an accurate diagnosis, it is important to know the imaging characteristics related to the pathophysiology of not only infectious spondylitis but also non-infectious spinal diseases, which requires differentiation from infection.

Lumbar Angiomatous Meningioma in a Dog (개에서 발생한 요추 혈관종성수막종 증례)

  • Sohn, Jung-Min;Kim, Bo-Eun;Jung, Sun-Young;Ji, Seo-Yeoun;Yoon, Dae-Young;Kweon, Oh-Kyeong;Kim, Dae-Yong;Choi, Min-Cheol;Yoon, Junghee
    • Journal of Veterinary Clinics
    • /
    • v.31 no.2
    • /
    • pp.152-155
    • /
    • 2014
  • An 11-year-old castrated Schnauzer presented with paraplegia for the last two weeks, initially developed pelvic limb ataxia 6 months ago and left pelvic limb paresis 3 months ago. On neurological examination, paraplegia and postural reaction deficits were noted in the pelvic limbs with no deep pain sensation, and the dog showed exaggerated spinal reflexes and involuntary urination. Magnetic resonance (MR) images of thoracolumbar spinal cord were obtained with a 0.3 Tesla magnet. A mass with a broad base to the dorsal and left dural margins was identified at the level of L2, causing marked spinal cord compression. The mass showed isointensity to the spinal cord on T1-weighted (T1W) precontrast images, hyperintensity on T2-weighted images, marked homogeneous contrast enhancement with well-defined margins and the "dural tail" sign on T1W postcontrast images. An intradural-extramedullay tumor was considered, most likely, meningioma was highly suggestive. Left-sided hemilaminectomy and dorsal laminectomy were performed. An intradural mass partially adherent to dura mater was compressing the spinal cord, and the mass was completely removed with the attached dura mater. A histopathologic diagnosis of angiomatous subtype meningioma was made.

Syringe Reuse Issues in Automated Contrast Injection System in Dynamic Magnetic Resonance Imaging (조영제 자동주입기를 활용한 자기공명영상 동적검사 시 실린지 재사용의 문제)

  • Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.11
    • /
    • pp.445-450
    • /
    • 2019
  • This study proves that syringe reuse of automated injection system entails a risk of contrast media reflux and saline solution contamination which are pumped by a piston into the patients' venous cannula in the dynamic MR images, we will be aware of the serious problem. To quantify the contrast media contamination effect on the saline solution, identical volume of the saline solution was collected before and after the contrast injection to the patients' venous cannula following T1 weighted image scanning to verify whether signal intensities differences are observed. The signal intensity of saline solution after the contrast injection was significantly higher than that of saline before injection by 523.43%. This result is due to the backflow that contaminates the saline solution on the opposite side when the contrast agent is injected. In conclusion, the syringe used to inject contrast medium. causes cross-contamination due to contrast reflux. Therefore, even if the same patient's examination is used for quantitative analysis, the error should be avoided by changing the acquisition sequence or replacing the syringe.

Removal of Edge Artifact due to Pertial Volume Effect in the Adaptive Template Filtering (적응 템플릿 필터링에서 복셀의 부분 볼륨 효과로 인한 헤지 아티팩트의 제거)

  • 안창범;송영철
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.120-127
    • /
    • 2000
  • Adaptive template filtering has been proposed recently for enhancement of signal-to-noise ratio without loss of resolution. In the adaptive template filtering, an optimal template among multiple templates is selected, then linear least square error filtering based on the template is applied in vowel by vowel basis. In some magnetic resonance imaging, where the distribution of gray level has relatively small dynamic range, e.g., $T_1$ imaging, however, artificial stair-like artifact is observed at near edges. This is partially due to the edge enhancement effect in such yokels that contain multiple compounds at the boundaries of tissues. The gray levels of these yokels become similar gray levels of near dominant vowels that contain single compound by the adaptive filtering, which enlarges edge discontinuities. In this paper, we propose a technique to eliminate such artifact by identifying those yokels that contain multiple compounds and assigning the largest template for them. Filtered images with the proposed technique show substantial visual enhancement at the edges without degradation of peak signal-to-noise ratio compared to the original adaptive template filtering for both magnetic resonance images and phantom images.

  • PDF